964 resultados para Raman amplifiers


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Loss of coherence with increasing excitation amplitudes and spatial size modulation is a fundamental problem in designing Raman fiber lasers. While it is known that ramping up laser pump power increases the amplitude of stochastic excitations, such higher energy inputs can also lead to a transition from a linearly stable coherent laminar regime to a non-desirable disordered turbulent state. This report presents a new statistical methodology, based on first passage statistics, that classifies lasing regimes in Raman fiber lasers, thereby leading to a fast and highly accurate identification of a strong instability leading to a laminar-turbulent phase transition through a self-consistently defined order parameter. The results have been consistent across a wide range of pump power values, heralding a breakthrough in the non-invasive analysis of fiber laser dynamics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We experimentally investigate three Raman fibre laser based amplification techniques with second-order bidirectional pumping. Relatively intensity noise (RIN) being transferred to the signal can be significantly suppressed by reducing first-order reflection near the input end. © 2015 OSA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We numerically optimise in-span signal power asymmetry in advanced Raman amplification schemes, reaching 3% over 62 km SMF, and evaluate its impact on the performance of systems using mid-link OPC using 7 × 15 16QAM Nyquist-spaced WDM-PDM. © 2015 OSA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present here experimental observation of different spatio-temporal generation regimes in quasi-CW Raman fiber laser in the most simple experimental configuration. The generation regimes depend on pump power and range from partial mode-locking to turbulent, and a generation of short-lived pulses. While in temporal domain transitions could be described in quantitative way, in spatio-temporal domain they represent qualitative change in observed dynamics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We numerically optimise in-span signal power asymmetry in different advanced Raman amplification schemes, achieving a 3% asymmetry over 62 km SMF using random DFB Raman laser amplifier. We then evaluate the impact of such asymmetry on the performance of systems using mid-link OPC by simulating transmission of 7 x 15 Gbaud 16QAM Nyquist-spaced WDM-PDM signals. (C) 2015 Optical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The modulation instability (MI) in optical fiber amplifiers and lasers with anomalous dispersion leads to cw radiation breakup. This can be both a detrimental effect limiting the performance of amplifiers and an underlying physical mechanism in the operation of MI-based devices. Here we revisit the analytical theory of MI in fiber optical amplifiers. The results of the exact theory are compared with the previously used adiabatic approximation model, and the range of applicability of the latter is determined. © 2010 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose and experimentally demonstrate a new method to extend the range of Brillouin optical time domain analysis (BOTDA) systems. It exploits the virtual transparency created by second-order Raman pumping in optical fibers. The idea is theoretically analyzed and experimentally demonstrated in a 50 km fiber. By working close to transparency, we also show that the measurement length of the BOTDA can be increased up to 100 km with 2 meter resolution. We envisage extensions of this technique to measurement lengths well beyond this value, as long as the issue of relative intensity noise (RIN) of the primary Raman pump can be avoided. © 2010 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate lasing based on a random distributed feedback due to the Raman amplified Rayleigh backscattering in different types of cavities with and without conventional point-action reflectors. Quasistationary generation of a narrowband spectrum is achieved despite the random nature of the feedback. The generated spectrum is localized at the reflection or gain spectral maxima in schemes with and without point reflectors, respectively. The length limit for a conventional cavity and the minimal pump power required for the lasing based purely on a random distributed feedback are determined. © 2010 The American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate a Q-switched Raman fiber laser using molybdenum disulfide (MoS2) as a saturable absorber (SA). The SA is assembled by depositing a mechanically exfoliated MoS2 onto a fiber ferrule facet before it is matched with another clean ferrule via a connector. It is inserted in a Raman fiber laser cavity with a total cavity length of about 8km to generate a Q-switching pulse train operating at 1560.2 nm. A 7.7-km-long dispersion compensating fiber with 584 ps·nm?1km?1 of dispersion is used as a nonlinear gain medium. As the pump power is increased from 395mW to 422mW, the repetition rate of the Q-switching pulses can be increased from 132.7 to 137.4 kHz while the pulse width is concurrently decreased from 3.35μs to 3.03 μs. The maximum pulse energy of 54.3 nJ is obtained at the maximum pump power of 422mW. These results show that the mechanically exfoliated MoS2 SA has a great potential to be used for pulse generation in Raman fiber laser systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Temporal dynamics of Raman fibre lasers tend to have very complex nature, owing to great cavity lengths and high nonlinearity, being stochastic on short time scales and quasi-continuous on longer time scales. Generally fibre laser intensity dynamics is represented by one-dimensional time-series, which in case of quasi-continuous wave generation in Raman fibre lasers gives little insight into the processes underlying the operation of a laser. New methods of analysis and data representation could help to uncover the underlying physical processes, understand the dynamics or improve the performance of the system. Using intrinsic periodicity of laser radiation, one dimensional intensity time series of a Raman fibre laser was analysed over fast and slow variation time. This allowed to experimentally observe various spatio-temporal regimes of generation, such as laminar, turbulent, partial mode-lock, as well as transitions between them and identify the mechanisms responsible for the transitions. Great cavity length and high nonlinearity also make it difficult to achieve stable high repetition rate mode-locking in Raman fibre lasers. Using Faraday parametric instability in extremely simple linear cavity experimental configuration, a very high order harmonic mode-locking was achieved in ò.ò kmlong Raman fibre laser. The maximum achieved pulse repetition rate was 12 GHz, with 7.3 ps long Gaussian shaped pulses. There is a new type of random lasers – random distributed feedback Raman fibre laser, which temporal properties cannot be controlled by conventionalmode-locking or Q-switch techniques and mechanisms. By adjusting the pump configuration, a very stable pulsed operation of random distributed feedback Raman fibre laser was achieved. Pulse duration varied in the range from 50 to 200 μs depending on the pump power and the cavity length. Pulse repetition rate scaling on the parameters of the system was experimentally identified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Benzodiazepines are among the most prescribed compounds for anti-anxiety and are present in many toxicological screens. These drugs are also prominent in the commission of drug facilitated sexual assaults due their effects on the central nervous system. Due to their potency, a low dose of these compounds is often administered to victims; therefore, the target detection limit for these compounds in biological samples is 10 ng/mL. Currently these compounds are predominantly analyzed using immunoassay techniques; however more specific screening methods are needed. ^ The goal of this dissertation was to develop a rapid, specific screening technique for benzodiazepines in urine samples utilizing surface-enhanced Raman spectroscopy (SERS), which has previously been shown be capable of to detect trace quantities of pharmaceutical compounds in aqueous solutions. Surface enhanced Raman spectroscopy has the advantage of overcoming the low sensitivity and fluorescence effects seen with conventional Raman spectroscopy. The spectra are obtained by applying an analyte onto a SERS-active metal substrate such as colloidal metal particles. SERS signals can be further increased with the addition of aggregate solutions. These agents cause the nanoparticles to amass and form hot-spots which increase the signal intensity. ^ In this work, the colloidal particles are spherical gold nanoparticles in aqueous solution with an average size of approximately 30 nm. The optimum aggregating agent for the detection of benzodiazepines was determined to be 16.7 mM MgCl2, providing the highest signal intensities at the lowest drug concentrations with limits of detection between 0.5 and 127 ng/mL. A supported liquid extraction technique was utilized as a rapid clean extraction for benzodiazepines from urine at a pH of 5.0, allowing for clean extraction with limits of detection between 6 and 640 ng/mL. It was shown that at this pH other drugs that are prevalent in urine samples can be removed providing the selective detection of the benzodiazepine of interest. ^ This technique has been shown to provide rapid (less than twenty minutes), sensitive, and specific detection of benzodiazepines at low concentrations in urine. It provides the forensic community with a sensitive and specific screening technique for the detection of benzodiazepines in drug facilitated assault cases.^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lo studio del polimorfismo gioca un ruolo fondamentale in diversi ambiti di ricerca, con applicazioni importanti nel campo dei semi conduttori organici e dei farmaci, dovuto al fatto che i diversi polimorfi di una sostanza presentano proprietà chimico-fisiche distinte. Questo lavoro di tesi si è focalizzato sullo studio del polimorfismo del paracetamolo, principio attivo (API) di diversi farmaci molto utilizzati, attraverso l’utilizzo della microscopia Raman. La microscopia Raman è una tecnica efficace per l’indagine del polimorfismo di materiali organici ed inorganici, in quanto permette di monitorare la presenza di diverse fasi solide e le loro trasformazioni su scala micrometrica. Le differenze di struttura cristallina che caratterizzano i polimorfi vengono analizzate attraverso gli spettri Raman nella regione dei modi reticolari (10-150 cm^{-1}), le cui frequenze sondano le interazioni inter-molecolari, molto sensibili anche a lievi differenze di impaccamento molecolare. Con questa tecnica abbiamo caratterizzato le forme I, II, III (quella elusiva) e diverse miscele di fase di paracetamolo su campioni ottenuti con numerose tecniche di crescita dei cristalli. Per questa tesi è stato svolto anche uno studio computazionale, attraverso metodi Density Functional Theory (DFT) per la molecola isolata e metodi di minimizzazione dell’energia e di dinamica reticolare per i sistemi cristallini. Abbiamo inoltre verificato se il modello di potenziale di letteratura scelto (Dreiding [Mayo1990]) fosse adatto per descrivere la molecola di paracetamolo, le strutture dei suoi polimorfi e i relativi spettri vibrazionali.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Preprint

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a new bidirectional pumping scheme with dual order forward pumps is proposed. Performance is compared numerically with conventional bidirectional and backward only pumping schemes for a 70 nm bandwidth, 61.5 km distributed Raman amplifier. We demonstrate that it is possible to design a flat gain spectrum with improved noise figure and OSNR, as well as a low gain ripple (<1 dB).