962 resultados para RESONANCE EFFECT
Resumo:
Summary This systematic review demonstrates that vitamin D supplementation does not have a significant effect on muscle strength in vitamin D replete adults. However, a limited number of studies demonstrate an increase in proximal muscle strength in adults with vitamin D deficiency. Introduction The purpose of this study is to systematically review the evidence on the effect of vitamin D supplementation on muscle strength in adults. Methods A comprehensive systematic database search was performed. Inclusion criteria included randomised controlled trials (RCTs) involving adult human participants. All forms and doses of vitamin D supplementation with or without calcium supplementation were included compared with placebo or standard care. Outcome measures included evaluation of strength. Outcomes were compared by calculating standardised mean difference (SMD) and 95% confidence intervals. Results Of 52 identified studies, 17 RCTs involving 5,072 participants met the inclusion criteria. Meta-analysis showed no significant effect of vitamin D supplementation on grip strength (SMD −0.02, 95%CI −0.15,0.11) or proximal lower limb strength (SMD 0.1, 95%CI −0.01,0.22) in adults with 25(OH)D levels >25 nmol/L. Pooled data from two studies in vitamin D deficient participants (25(OH)D <25 nmol/L) demonstrated a large effect of vitamin D supplementation on hip muscle strength (SMD 3.52, 95%CI 2.18, 4.85). Conclusion Based on studies included in this systematic review, vitamin D supplementation does not have a significant effect on muscle strength in adults with baseline 25(OH)D >25 nmol/L. However, a limited number of studies demonstrate an increase in proximal muscle strength in adults with vitamin D deficiency. Keywords Muscle – Muscle fibre – Strength – Vitamin D
Resumo:
Background Total hip arthroplasty carried out using cemented modular-neck implants provides the surgeon with greater intra-operative flexibility and allows more controlled stem positioning. Methods In this study, finite element models of a whole femur implanted with either the Exeter or with a new cemented modular-neck total hip arthroplasty (separate, neck and stem components) were developed. The changes in bone and cement mantle stress/strain were assessed for varying amounts of neck offset and version angle for the modular-neck device for two simulated physiological load cases: walking and stair climbing. Since the Exeter is the gold standard for polished cemented total hip arthroplasty stem design, bone and cement mantle stresses/strains in the modular-neck finite element models were compared with finite element results for the Exeter. Findings For the two physiological load cases, stresses and strains in the bone and cement mantle were similar for all modular-neck geometries. These results were comparable to the bone and cement mechanics surrounding the Exeter. These findings suggest that the Exeter and the modular neck device distribute stress to the surrounding bone and cement in a similar manner. Interpretation It is anticipated that the modular-neck device will have a similar short-term clinical performance to that of the Exeter, with the additional advantages of increased modularity.
Resumo:
Some of my most powerful spiritual experiences have come from the splendorous and sublime sounding hymns performed by a choir and church organ at the traditional Anglican church I’ve attended since I was very young. In the later stage of my life, my pursuit of education in the field of engineering caused me to move to Australia where I regularly attended a contemporary evangelical church and subsequently became a music director in the faith community. This environmental and cultural shift altered my perception and musical experiences of Christian music and led me to enquire about the relationship between Christian liturgy and church music. Throughout history church musicians and composers have synthesised the theological, congregational, cultural and musical aspects of church liturgy. Many great composers have taken into account the conditions surrounding the process of sacred composition and arrangement of music to enhance the experience of religious ecstasy – they sought resonances with Christian values and beliefs to draw congregational participation into the light of praising and glorifying God. As a music director in an evangelical church this aspiration has become one I share. I hope to identify and define the qualities of these resonances that have been successful and apply them to my own practice. Introduction and Structure of the Thesis In this study I will examine four purposively selected excerpts of Christian church vocal music combining theomusicological and semiotic analysis to help identify guidelines that might be useful in my practice as a church music director. The four musical excerpts have been selected based upon their sustained musical and theological impact over time, and their ability to affect ecstatic responses from congregations. This thesis documents a personal journey through analysis of music and uses a context that draws upon ethno-musicological, theological and semiotic tools that lead to a preliminary framework and principles which can then be applied to the identified qualities of resonance in church music today. The thesis is comprised of four parts. Part 1 presents a literature study on the relationship between sacred music, the effects of religious ecstasy and the Christian church. Multiple lenses on this phenomenon are drawn from the viewpoints of prominent western church historians, Biblical theologians, and philosophers. The literature study continues in Part 2, where the role of embodiment is examined from the current perspective of cognitive learning environments. This study offers a platform for a critical reflection on two distinctive musical liturgical systems that have treated differently the notion of embodied understanding amidst a shifting church paradigm. This allows an in-depth theological and philosophical understanding of the liturgical conditions around sacred music-making that relates to the monistic and dualistic body/mind. Part 3 involves undertaking a theomusicological methodology that utilises creative case studies of four purposively selected spiritual pieces. A semiotic study focuses on specific sections of sacred vocal works that express the notions of ‘praise’ and ‘glorification’, particularly in relation to these effects,which combine an analysis of theological perspectives around religious ecstasy and particular spiritual themes. Part 4 presents the critiques and findings gathered from the study that incorporate theoretical and technological means to analyse the purposive selected musical artefact, particularly with the sonic narratives expressing notions of ‘Praise' and 'Glory’. The musical findings are further discussed in relation to the notion of resonance, and then a conceptual framework for the role of contemporary musicdirector is proposed. The musical and Christian terminologies used in the thesis are explained in the glossary, and the appendices includes tables illustrating the musical findings, conducted surveys, written musical analyses and audio examples of selected sacred pieces available on the enclosed compact disc.
Resumo:
This study investigated the Kinaesthetic Fusion Effect (KFE) first described by Craske and Kenny in 1981. The current study did not replicate these findings. Participants did not perceive any reduction in the sagittal separation of a button pressed by the index finger of one arm and a probe touching the other, following repeated exposure to the tactile stimuli present on both unseen arms. This study’s failure to replicate the widely-cited KFE as described by Craske et al. (1984) suggests that it may be contingent on several aspects of visual information, especially the availability of a specific visual reference, the role of instructions regarding gaze direction, and the potential use of a line of sight strategy when referring felt positions to an interposed surface. In addition, a foreshortening effect was found; this may result from a line-of-sight judgment and represent a feature of the reporting method used. The transformed line of sight data were regressed against the participant reported values, resulting in a slope of 1.14 (right arm) and 1.11 (left arm), and r > 0.997 for each. The study also provides additional evidence that mis-perceptions of the mediolateral position of the limbs specifically their separation and consistent with notions of Gestalt grouping, is somewhat labile and can be influenced by active motions causing touch of one limb by the other. Finally, this research will benefit future studies that require participants to report the perceived locations of the unseen limbs.
Resumo:
Raman microprobe spectra of the clay mineral Wyoming SWy-2-sodium montmorillonite intercalated with the surfactants, methyltrioctadecylammonium bromide (TOMA) dimethyldiotadecylammonium bromide (DODMA) and octadecyl-trimethylammonium bromide (ODTMA), have been measured in the CH2 stretching region at external pressures up to ~40 kbar with the aid of a diamond-anvil cell. In the case of the intercalated clays containing TOMA and DODMA, the Raman data afford evidence for gauche to trans conformational changes in the orientation of the CH2 chains in the surfactants with increasing pressure. These conformational changes are reversed completely upon the release of pressure.
Resumo:
The effect of thermal radiation on a steady two-dimensional natural convection laminar flow of viscous incompressible optically thick fluid along a vertical flat plate with streamwise sinusoidal surface temperature has been investigated in this study. Using the appropriate variables; the basic governing equations are transformed to convenient form and then solved numerically employing two efficient methods, namely, Implicit finite difference method (IFD) together with Keller box scheme and Straight forward finite difference (SFFD) method. Effects of the variation of the physical parameters, for example, conduction-radiation parameter (Planck number), surface temperature parameter, and the amplitude of the surface temperature, are shown on the skin friction and heat transfer rate quantitatively are shown numerically. Velocity and temperature profiles as well as streamlines and isotherms are also presented and discussed for the variation of conduction-radiation parameter. It is found that both skin-friction and rate of heat transfer are enhanced considerably by increasing the values of conduction radiation parameter, Rd.
Resumo:
Laminar magnetohydrodynamic (MHD) natural convection flow from an isothermal sphere immersed in a fluid with viscosity proportional to linear function of temperature has been studied. The governing boundary layer equations are transformed into a non-dimensional form and the resulting nonlinear system of partial differential equations are reduced to convenient form which are solved numerically by two very efficient methods, namely, (i) Implicit finite difference method together with Keller box scheme and (ii) Direct numerical scheme. Numerical results are presented by velocity and temperature distribution, streamlines and isotherms of the fluid as well as heat transfer characteristics, namely the local skin-friction coefficients and the local heat transfer rate for a wide range of magnetohydrodynamic paramagnet and viscosity-variation parameter.