939 resultados para QUALITY study


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertation elaborated for the partial fulfilment of the requirements of the Master Degree in Civil Engineering in the Speciality Area of Hydarulics

Relevância:

30.00% 30.00%

Publicador:

Resumo:

X-ray fluoroscopy is essential in both diagnosis and medical intervention, although it may contribute to significant radiation doses to patients that have to be optimised and justified. Therefore, it is crucial to the patient to be exposed to the lowest achievable dose without compromising the image quality. The purpose of this study was to perform an analysis of the quality control measurements, particularly dose rates, contrast and spatial resolution of Portuguese fluoroscopy equipment and also to provide a contribution to the establishment of reference levels for the equipment performance parameters. Measurements carried out between 2007 and 2013 on 143 fluoroscopy equipment distributed by 34 nationwide health units were analysed. The measurements suggest that image quality and dose rates of Portuguese equipment are congruent with other studies, and in general, they are as per the Portuguese law. However, there is still a possibility of improvements intending optimisation at a national level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Particulate matter (PM) can have a significant impact on human health and on artifacts stored and kept inside museums and archives. To the author's knowledge, its immediate and/or longterm concentrations and distribution on Portuguese archives has never been determined. Four Portuguese archives (with and without HVAC/air filtration systems) were selected and the immediate concentration of airborne particulate matter was measured by active sampling. Indoor-outdoor ratios were also determined. International and national guidelines were used to ascertain the environment’s quality, both for the readers and staff and for the documents preserved in these institutions. Inside, PM2.5 ranged between 0.37μg/m3 and 27.61μg/m3, while PM10 ranged between 4.43μg/m3 and 285.52μg/m3. The lowest values were determined in storage rooms and the highest in reading rooms. In terms of human health, Portuguese guidelines for immediate PM10 concentration were not met in several locations. For conservation purposes, storage rooms were classified according to an original air quality grid. Air filtration systems proved valuable in maintaining a safe environment for our written heritage and the staff and readers that deal with it and care for it every day. This study constitutes the first snapshot of the particulate matter concentrations and distribution in Portuguese Archives.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação apresentada à Escola Superior de Educação de Lisboa para obtenção de grau de mestre em Educação Especial, domínio Cognição e Multideficiência

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Stringent cost and energy constraints impose the use of low-cost and low-power radio transceivers in large-scale wireless sensor networks (WSNs). This fact, together with the harsh characteristics of the physical environment, requires a rigorous WSN design. Mechanisms for WSN deployment and topology control, MAC and routing, resource and mobility management, greatly depend on reliable link quality estimators (LQEs). This paper describes the RadiaLE framework, which enables the experimental assessment, design and optimization of LQEs. RadiaLE comprises (i) the hardware components of the WSN testbed and (ii) a software tool for setting-up and controlling the experiments, automating link measurements gathering through packets-statistics collection, and analyzing the collected data, allowing for LQEs evaluation. We also propose a methodology that allows (i) to properly set different types of links and different types of traffic, (ii) to collect rich link measurements, and (iii) to validate LQEs using a holistic and unified approach. To demonstrate the validity and usefulness of RadiaLE, we present two case studies: the characterization of low-power links and a comparison between six representative LQEs. We also extend the second study for evaluating the accuracy of the TOSSIM 2 channel model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

SERVQUAL is the most popular instrument to ascertain service quality. However, some debate exists about its ability to characterize different service environments. Furthermore, there is not a consensus about the inclusion of customer expectations in the model. The research presented in this paper intends to discuss the applicability of SERVQUAL to restaurant services and to analyze the inclusion of customer expectations in such environment. The research was developed in a Portuguese resort and more than 300 customers, from two different restaurants, were invited to participate in the study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: In Angola, malaria is an endemic disease having a major impact on the economy. The WHO recommends testing for all suspected malaria cases, to avoid the presumptive treatment of this disease. In malaria endemic regions laboratory technicians must be very comfortable with microscopy, the golden standard for malaria diagnosis, to avoid the incorrect diagnosis. The improper use of medication promotes drug resistance and undesirable side effects. The present study aims to assess the impact of a three-day refresher course on the knowledge of technicians, quality of blood smears preparation and accuracy of microscopy malaria diagnosis, using qPCR as reference method. Methods: This study was implemented in laboratories from three hospitals in different provinces of Angola: Bengo, Benguela and Luanda. In each laboratory samples were collected before and after the training course (slide with thin and thick blood smears, a dried blood spot and a form). The impact of the intervention was evaluated through a written test, the quality of slide preparation and the performance of microscopy. Results: It was found a significant increase on the written test median score, from 52.5% to 65.0%. A total of 973 slides were analysed to evaluate the quality of thick and thin blood smears. Considering all laboratories there was a significant increase in quality of thick and thin blood smears. To determine the performance of microscopy using qPCR as the reference method we used 1,028 samples. Benguela presented the highest values for specificity, 92.9% and 98.8% pre and post-course, respectively and for sensitivity the best pre-course was Benguela (75.9%) and post-course Luanda (75.0%). However, no significant increase in sensitivity and specificity after the training course was registered in any laboratory analysed. Discussion: The findings of this study support the need of continuous refresher training for microscopists and other laboratory staff. The laboratories should have a quality control programme to supervise the diagnosis and also to assess the periodicity of new training. However, other variables needed to be considered to have a correct malaria diagnosis, such as adequate equipment and reagents for staining and visualization, good working conditions, motivated and qualified personnel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The discovery of X-rays was undoubtedly one of the greatest stimulus for improving the efficiency in the provision of healthcare services. The ability to view, non-invasively, inside the human body has greatly facilitated the work of professionals in diagnosis of diseases. The exclusive focus on image quality (IQ), without understanding how they are obtained, affect negatively the efficiency in diagnostic radiology. The equilibrium between the benefits and the risks are often forgotten. It is necessary to adopt optimization strategies to maximize the benefits (image quality) and minimize risk (dose to the patient) in radiological facilities. In radiology, the implementation of optimization strategies involves an understanding of images acquisition process. When a radiographer adopts a certain value of a parameter (tube potential [kVp], tube current-exposure time product [mAs] or additional filtration), it is essential to know its meaning and impact of their variation in dose and image quality. Without this, any optimization strategy will be a failure. Worldwide, data show that use of x-rays has been increasingly frequent. In Cabo Verde, we note an effort by healthcare institutions (e.g. Ministry of Health) in equipping radiological facilities and the recent installation of a telemedicine system requires purchase of new radiological equipment. In addition, the transition from screen-films to digital systems is characterized by a raise in patient exposure. Given that this transition is slower in less developed countries, as is the case of Cabo Verde, the need to adopt optimization strategies becomes increasingly necessary. This study was conducted as an attempt to answer that need. Although this work is about objective evaluation of image quality, and in medical practice the evaluation is usually subjective (visual evaluation of images by radiographer / radiologist), studies reported a correlation between these two types of evaluation (objective and subjective) [5-7] which accredits for conducting such studies. The purpose of this study is to evaluate the effect of exposure parameters (kVp and mAs) when using additional Cooper (Cu) filtration in dose and image quality in a Computed Radiography system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Alzheimer Disease (AD) is characterized by progressive cognitive decline and dementia. Earlier diagnosis and classification of different stages of the disease are currently the main challenges and can be assessed by neuroimaging. With this work we aim to evaluate the quality of brain regions and neuroimaging metrics as biomarkers of AD. Multimodal Imaging Brain Connectivity Analysis (MIBCA) toolbox functionalities were used to study AD by T1weighted, Diffusion Tensor Imaging and 18FAV45 PET, with data obtained from the AD Neuroimaging Initiative database, specifically 12 healthy controls (CTRL) and 33 patients with early mild cognitive impairment (EMCI), late MCI (LMCI) and AD (11 patients/group). The metrics evaluated were gray-matter volume (GMV), cortical thickness (CThk), mean diffusivity (MD), fractional anisotropy (FA), fiber count (FiberConn), node degree (Deg), cluster coefficient (ClusC) and relative standard-uptake-values (rSUV). Receiver Operating Characteristic (ROC) curves were used to evaluate and compare the diagnostic accuracy of the most significant metrics and brain regions and expressed as area under the curve (AUC). Comparisons were performed between groups. The RH-Accumbens/Deg demonstrated the highest AUC when differentiating between CTRLEMCI (82%), whether rSUV presented it in several brain regions when distinguishing CTRL-LMCI (99%). Regarding CTRL-AD, highest AUC were found with LH-STG/FiberConn and RH-FP/FiberConn (~100%). A larger number of neuroimaging metrics related with cortical atrophy with AUC>70% was found in CTRL-AD in both hemispheres, while in earlier stages, cortical metrics showed in more confined areas of the temporal region and mainly in LH, indicating an increasing of the spread of cortical atrophy that is characteristic of disease progression. In CTRL-EMCI several brain regions and neuroimaging metrics presented AUC>70% with a worst result in later stages suggesting these indicators as biomarkers for an earlier stage of MCI, although further research is necessary.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Multiple Sclerosis (MS) is a chronic disease of the central nervous system that affects more often young adults in the prime of his career and personal development, with no cure and unknown causes. The most common signs and symptoms are fatigue, muscle weakness, changes in sensation, ataxia, changes in balance, gait difficulties, memory difficulties, cognitive impairment and difficulties in problem solving MS is a relatively common neurological disorder in which various impairments and disabilities impact strongly on function and daily life activities. Purpose: The aim of this study is to examine the implications of an Intervention Program of Physical Activity (IPPA) in quality of life in MS patients, six months after the intervention.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To propose a cut-off for the World Health Organization Quality of Life-Bref (WHOQOL-bref) as a predictor of quality of life in older adults. METHODS Cross-sectional study with 391 older adults registered in the Northwest Health District in Belo Horizonte, MG, Southeastern Brazil, between October 8, 2010 and May 23, 2011. The older adults’ quality of life was measured using the WHOQOL-bref. The analysis was rationalized by outlining two extreme and simultaneous groups according to perceived quality of life and satisfaction with health (quality of life good/satisfactory – good or very good self-reported quality of life and being satisfied or very satisfied with health – G5; and poor/very poor quality of life – poor or very poor self-reported quality of life and feeling dissatisfied or very dissatisfied with health – G6). A Receiver-Operating Characteristic curve (ROC) was created to assess the diagnostic ability of different cut-off points of the WHOQOL-bref. RESULTS ROC curve analysis indicated a critical value 60 as the optimal cut-off point for assessing perceived quality of life and satisfaction with health. The area under the curve was 0.758, with a sensitivity of 76.8% and specificity of 63.8% for a cut-off of ≥ 60 for overall quality of life (G5) and sensitivity 95.0% and specificity of 54.4% for a cut-off of < 60 for overall quality of life (G6). CONCLUSIONS Diagnostic interpretation of the ROC curve revealed that cut-off < 60 for overall quality of life obtained excellent sensitivity and negative predictive value for tracking older adults with probable worse quality of life and dissatisfied with health.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To analyze evidence of the validity and reliability of a Brazilian Portuguese version of the Quality of Care Scale from the perspective of people with physical and intellectual disabilities.METHODS There were 162 people with physical disabilities and 156 with intellectual disabilities from Porto Alegre and metropolitan region, who participated in the study in 2008. Classical psychometrics was used to independently analyze the two samples. Hypotheses for evidence of criterion validity (concurrent type) were tested with the Mann-Whitney test for non-normal distributions. Principal components analysis was used to explore factorial models. Evidence of reliability was calculated with Cronbach alpha for the scales and subscales. Test-retest reliability was analyzed for individuals with intellectual disabilities through intra-class correlation coefficient and the Willcoxon test.RESULTS The principal components in the group with physical disabilities replicated the original model presented as a solution to the international project data. Evidence of discriminant validity and test-retest reliability was found.CONCLUSIONS The transcultural factor model found within the international sample project seems appropriate for the samples investigated in this study, especially the physical disabilities group. Depression, pain, satisfaction with life and disability may play a mediating role in the evaluation of quality of care. Additional research is needed to add to evidence of the validity of the instruments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To analyze the association between sleep quality and quality of life of nursing professionals according to their work schedules.METHODS A prospective, cross-sectional, observational study was conducted between January and December 2010, with 264 nursing professionals, drawn from 989 subjects at Botucatu General Hospital and stratified by professional category. The Pittsburg Sleep Quality Index and the WHOQOL-bref were administered to evaluate sleep quality and quality of life, respectively. Self-reported demographic data were collected with a standard form. Continuous variables were reported as means and standard deviations, and categorical variables were expressed as proportions. Associations were evaluated using Spearman’s correlation coefficient. The association of night-shift work and gender with sleep disturbance was evaluated by logistic regression analysis using a model adjusted for age and considering sleep disturbance the dependent variable. The level of significance was p < 0.05.RESULTS Night-shift work was associated with severe worsening of at least one component of sleep quality in the model adjusted for age (OR = 1.91; 95%CI 1.04;3.50; p = 0.036). Female gender was associated with sleep disturbance (OR = 3.40; 95%CI 1.37;8.40; p = 0.008). Quality of life and quality of sleep were closely correlated (R = -0.56; p < 0.001).CONCLUSIONS Characteristics of the nursing profession affect sleep quality and quality of life, and these two variables are associated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE Develop an index to evaluate the maternal and neonatal hospital care of the Brazilian Unified Health System.METHODS This descriptive cross-sectional study of national scope was based on the structure-process-outcome framework proposed by Donabedian and on comprehensive health care. Data from the Hospital Information System and the National Registry of Health Establishments were used. The maternal and neonatal network of Brazilian Unified Health System consisted of 3,400 hospitals that performed at least 12 deliveries in 2009 or whose number of deliveries represented 10.0% or more of the total admissions in 2009. Relevance and reliability were defined as criteria for the selection of variables. Simple and composite indicators and the index of completeness were constructed and evaluated, and the distribution of maternal and neonatal hospital care was assessed in different regions of the country.RESULTS A total of 40 variables were selected, from which 27 single indicators, five composite indicators, and the index of completeness of care were built. Composite indicators were constructed by grouping simple indicators and included the following variables: hospital size, level of complexity, delivery care practice, recommended hospital practice, and epidemiological practice. The index of completeness of care grouped the five variables and classified them in ascending order, thereby yielding five levels of completeness of maternal and neonatal hospital care: very low, low, intermediate, high, and very high. The hospital network was predominantly of small size and low complexity, with inadequate child delivery care and poor development of recommended and epidemiological practices. The index showed that more than 80.0% hospitals had a low index of completeness of care and that most qualified heath care services were concentrated in the more developed regions of the country.CONCLUSIONS The index of completeness proved to be of great value for monitoring the maternal and neonatal hospital care of Brazilian Unified Health System and indicated that the quality of health care was unsatisfactory. However, its application does not replace specific evaluations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To assess the prevalence of anemia and associated factors in older adults. METHODS The prevalence and factors associated with anemia in older adults were studied on the basis of the results of the Saúde, Bem-Estar e Envelhecimento (SABE – Health, Welfare and Aging) study. A group of 1,256 individuals were interviewed during the third wave of the SABE study performed in Sao Paulo, SP, in 2010. The study included 60.4% females; the mean age of the participants was 70.4 years, and their average education was 5.3 years. The dependent variable was the presence of anemia (hemoglobin levels: 12 g/dL in women and 13 g/dL in men). Descriptive analysis and hierarchical logistic regression were performed. The independent variables were as follows: a) demographics: gender, age, and education and b) clinical characteristics: self-reported chronic diseases, presence of cognitive decline and depression symptoms, and body mass index. RESULTS The prevalence of anemia was 7.7% and was found to be higher in oldest adults. There was no difference between genders, although the hemoglobin distribution curve in women showed a displacement toward lower values in comparison with the distribution curve in men. Advanced age (OR = 1.07; 95%CI 0.57;1.64; p < 0.001), presence of diabetes (OR = 2.30; 95%CI 1.33;4.00; p = 0.003), cancer (OR = 2.72; 95%CI 1.2;6.11; p = 0.016), and presence of depression symptoms (OR = 1.75; 95%CI 1.06;2.88; p = 0.028) remained significant even after multiple analyses. CONCLUSIONS The prevalence of anemia in older adults was 7.7% and was mainly associated with advanced age and presence of chronic diseases. Thus, anemia can be an important marker in the investigation of health in older adults because it can be easily diagnosed and markedly affects the quality of life of older adults.