913 resultados para Power-generation
Resumo:
This paper deals with heat transfer on a moving plate by mean of an impinging jet. Three different turbulence models are used and it turns out that Lam-Bremhorst model is in good agreement with measurements when Re is lower that 5000. In case of moving strip (ratio m=V strip/V jet lower than 1/3), there is almost no effect of m on Nusselt distribution in the stagnation region.
Resumo:
In the casting of metals, tundish flow, welding, converters, and other metal processing applications, the behaviour of the fluid surface is important. In aluminium alloys, for example, oxides formed on the surface may be drawn into the body of the melt where they act as faults in the solidified product affecting cast quality. For this reason, accurate description of wave behaviour, air entrapment, and other effects need to be modelled, in the presence of heat transfer and possibly phase change. The authors have developed a single-phase algorithm for modelling this problem. The Scalar Equation Algorithm (SEA) (see Refs. 1 and 2), enables the transport of the property discontinuity representing the free surface through a fixed grid. An extension of this method to unstructured mesh codes is presented here, together with validation. The new method employs a TVD flux limiter in conjunction with a ray-tracing algorithm, to ensure a sharp bound interface. Applications of the method are in the filling and emptying of mould cavities, with heat transfer and phase change.
Resumo:
Metal casting is a process governed by the interaction of a range of physical phenomena. Most computational models of this process address only what are conventionally regarded as the primary phenomena – heat conduction and solidification. However, to predict other phenomena, such as porosity formation, requires modelling the interaction of the fluid flow, heat transfer, solidification and the development of stressdeformation in the solidified part of the casting. This paper will describe a modelling framework called PHYSICA[1] which has the capability to stimulate such multiphysical phenomena.
Resumo:
The consumption of energy on the planet is currently based on fossil fuels. They are responsible for adverse effects on the environment. Renewables propose solutions for this scenario, but must face issues related to the capacity of the power supply. Wind energy offshore emerging as a promising alternative. The speed and stability are greater winds over oceans, but the variability of these may cause inconvenience to the generation of electric power fluctuations. To reduce this, a combination of wind farms geographically distributed was proposed. The greater the distance between them, the lower the correlation between the wind velocity, increasing the likelihood that together achieve more stable power system with less fluctuations in power generation. The efficient use of production capacity of the wind park however, depends on their distribution in marine environments. The objective of this research was to analyze the optimal allocation of wind farms offshore on the east coast of the U.S. by Modern Portfolio Theory. The Modern Portfolio Theory was used so that the process of building portfolios of wind energy offshore contemplate the particularity of intermittency of wind, through calculations of return and risk of the production of wind farms. The research was conducted with 25.934 observations of energy produced by wind farms 11 hypothetical offshore, from the installation of 01 simulated ocean turbine with a capacity of 5 MW. The data show hourly time resolution and covers the period between January 1, 1998 until December 31, 2002. Through the Matlab R software, six were calculated minimum variance portfolios, each for a period of time distinct. Given the inequality of the variability of wind over time, set up four strategies rebalancing to evaluate the performance of the related portfolios, which enabled us to identify the most beneficial to the stability of the wind energy production offshore. The results showed that the production of wind energy for 1998, 1999, 2000 and 2001 should be considered by the portfolio weights calculated for the same periods, respectively. Energy data for 2002 should use the weights derived from the portfolio calculated in the previous time period. Finally, the production of wind energy in the period 1998-2002 should also be weighted by 1/11. It follows therefore that the portfolios found failed to show reduced levels of variability when compared to the individual production of wind farms hypothetical offshore
Resumo:
La hidroeléctrica Ituango es el proyecto de generación de energía más grande de Colombia y que tiene una importancia enorme para los pueblos que están ubicados en el área de influencia de esta obra. Ituango es un municipio ubicado en el norte lejano del departamento de Antioquia, que posee unas características especiales y que ha cambiado considerablemente su forma de vivir por la llegada del proyecto hidroeléctrico, considerando la magnitud de la obra, la llegada de más personas a la zona y el cambio socioeconómico que surge a raíz de esta situación.
Resumo:
Una alternativa para la producción de biocombustibles consiste en la transformación de residuos lignocelulósicos, entre los que se encuentran biomasas maderables y no maderables. Colombia al ser un país rico en recursos agrícolas genera grandes cantidades de residuos provenientes de monocultivos como es el café, la caña de azúcar, el banano entre otros. Los residuos de banano se producen en zonas en donde el acceso a la energía es escaso y el tratamiento actual dado a estos residuos se centra en los biológicos buscando un producto que ayude a disminuir la aplicación de fertilizantes a la tierra. Con este proyecto se busca estudiar el potencial aprovechamiento de estos residuos para su implementación como biocombustible para la combustión y obtener energía a partir de los mismos. En este trabajo se realizó una caracterización de los residuos de la planta del banano (pseudotallo y hoja) mediante análisis termogravimétrico con una termobalanza TA Instrument TGA Q500IF, con el fin de definir el contenido de los tres componentes principales (hemicelulosa, celulosa y lignina). Los experimentos fueron realizados bajo condiciones de pirólisis y por medio de un algoritmo implementado con la herramienta Scilab. Además, el objetivo fue desarrollar una herramienta para determinar los contenidos de cenizas, contenido de humedad, contenido de residuo carbonoso y contenidos de hemicelulosa, celulosa y lignina para un reactor de combustión desde un análisis termogravimétrico. Los valores encontrados permiten concluir que tanto el pseudotallo como la hoja de la planta de banano son residuos potenciales de aprovechamiento en el proceso de combustión con fines de generación de energía.
Resumo:
Compared to the use of traditional fossil fuels (coal, oil, natural gas), combustion of biomass and waste fuels has several environmental and economic advantages for heat and power generation. However, biomass and waste fuels might contain halogens (Cl, Br, F), alkali metals (Na, K) and heavy metals (Zn, Pb), which may cause harmful emissions and corrosion problems. Hightemperature corrosion occurs typically on furnace waterwalls and superheaters. The corrosion of the boiler tube materials limits the increase of thermal efficiency of steam boilers and leads to costly shutdowns and repairs. In recent years, some concerns have been raised about halogen (Cl, Br, and F)-related hightemperature corrosion in biomass- and waste-fired boilers. Chlorine-related high-temperature corrosion has been studied extensively. The presence of alkali chlorides in the deposits is believed to play a major role in the corrosion observed in biomass and waste fired boilers. However, there is much less information found in literature on the corrosion effect of bromine and fluorine. According to the literature, bromine is only assumed to play a role similar to chlorine; the role of fluorine is even less understood. In this work, a series of bubbling fluidized bed (BFB) bench-scale tests were carried out to characterize the formation and sulfation behaviors of KCl and KBr in BFB combustion conditions. Furthermore, a series of laboratory tests were carried out to investigate the hightemperature corrosion behaviors of three different superheater steels (10CrMo9-10, AISI 347 and Sanicro 28) exposed to potassium halides in ambient air and wet air (containing 30% H2O). The influence of H2O and O2 on the high-temperature corrosion of steels both with and without a salt (KCl) in three gas atmospheres (2% H2O-30% O2-N2, 2% H2O-2% O2-N2 and 30% H2O-2% O2-N2) was also studied. From the bench-scale BFB combustion tests, it was found that HBr has a clearly higher affinity for the available K forming KBr than HCl forming KCl. The tests also indicated that KCl has a higher tendency for sulfation than KBr. From the laboratory corrosion tests in ambient air (also called “dry air” in Paper III and Paper IV), it was found that at relatively low temperatures (≤ 550 °C) the corrosivity of KBr and KF are similar to KCl. At 600 °C, KF showed much stronger corrosivity than KBr and KCl, especially for 10CrMo9-10 and AISI 347. When exposed to KBr or KF, 10CrMo9-10 was durable at least up to 450 °C, while AISI 347 and Sanicro 28 were durable at least up to 550 °C. From the laboratory corrosion tests in wet air (30% H2O), no obvious effect of water vapor was detected at 450 °C. At 550 °C, the influence of water vapor became significant in some cases, but the trend was not consistent. At 550 °C, after exposure with KBr, 10CrMo9-10 suffered from extreme corrosion; after exposure with KF and KCl, the corrosion was less severe, but still high. At 550 °C, local deep pitting corrosion occurred on AISI 347 and Sanicro 28 after exposure with KF. Some formation of K2CrO4 was observed in the oxide layer. At 550 °C, AISI 347 and Sanicro 28 suffered from low corrosion (oxide layer thickness of < 10 μm) after exposure with KBr and KCl. No formation of K2CrO4 was observed. Internal oxidation occurred in the cases of AISI 347 with KBr and KCl. From the laboratory corrosion tests in three different gas atmospheres (2% H2O-30% O2-N2, 2% H2O-2% O2-N2 and 30% H2O-2% O2-N2), it was found that in tests with no salt, no corrosion occurred on AISI 347 and Sanicro 28 up to 600 °C in both the “O2-rich” (2% H2O-30% O2-N2) and “H2O-rich” (30% H2O-2% O2-N2) gas atmospheres; only 10CrMo9-10 showed increased corrosion with increasing temperature. For 10CrMo9-10 in the “O2-rich” atmosphere, the presence of KCl significantly increased the corrosion compared to the “no salt” cases. For 10CrMo9-10 in the “H2O-rich” atmosphere, the presence or absence of KCl did not show any big influence on corrosion. The formation of K2CrO4 was observed only in the case with the “O2-rich” atmosphere. Considering both the results from the BFB tests and the laboratory corrosion tests, if fuels containing Br were to be combusted, the corrosion damage of superheaters would be expected to be higher than if the fuels contain only Cl. Information generated from these studies can be used to help the boiler manufacturers in selecting materials for the most demanding combustion systems.
Resumo:
Los anuncios de impacto por cambio climático han llevado a los países a crear estrategias de mitigación y adaptación, dentro de las cuales se considera la promoción de generación de electricidad a través de fuentes renovables no convencionales -- El avance logrado ha incentivado a los usuarios del servicio de energía eléctrica a invertir en plantas de generación, eliminando la necesidad parcial de utilizar las redes de transmisión y distribución del sistema eléctrico, de tal forma que las redes eléctricas presentan una holgura gradual en cuanto a la energía que se transporta a través de ellas -- Este artículo presenta un análisis del impacto sobre los ingresos operacionales de una empresa distribuidora de energía por efecto de la entrada de soluciones de energía solar fotovoltaica en el segmento residencial de su área de influencia, encontrando que se generarían diferentes escalas de afectación, con valores de hasta el 3%
Resumo:
Physical control of water hyacinth consists of removing the plants from the water by hand or machines. It is considered over effetive because it involves removing the whole plants from water. The first attempt on physical control was in 1992 when weed infestation was causing serious problems to the fishing communities in Lake Kyoga. The fishermen had problems of accessing the lake as huge masses of mobile weed blocked landing sites. Furthermore, the fishers lost their nets, which were swept away by mobile water hyacinth. As a result, an integrated control strategy involving physical control (manual and mechanical removal) was put in place. Through this method, the fishers were able to open up access routes to fishing grounds even though weed mats often reblocked the access routes. In the infested lakes, manual removal offered remedial relief to fish Iandings and other access sites. Sites of strategic importance such as hydro-electric power generation dam, water intake points and docking points which had large masses of water hyacinth required heavy machinery and mechanical harvesters were used at these sites.
Resumo:
During the last decade, wind power generation has seen rapid development. According to the U.S. Department of Energy, achieving 20\% wind power penetration in the U.S. by 2030 will require: (i) enhancement of the transmission infrastructure, (ii) improvement of reliability and operability of wind systems and (iii) increased U.S. manufacturing capacity of wind generation equipment. This research will concentrate on improvement of reliability and operability of wind energy conversion systems (WECSs). The increased penetration of wind energy into the grid imposes new operating conditions on power systems. This change requires development of an adequate reliability framework. This thesis proposes a framework for assessing WECS reliability in the face of external disturbances, e.g., grid faults and internal component faults. The framework is illustrated using a detailed model of type C WECS - doubly fed induction generator with corresponding deterministic and random variables in a simplified grid model. Fault parameters and performance requirements essential to reliability measurements are included in the simulation. The proposed framework allows a quantitative analysis of WECS designs; analysis of WECS control schemes, e.g., fault ride-through mechanisms; discovery of key parameters that influence overall WECS reliability; and computation of WECS reliability with respect to different grid codes/performance requirements.
Resumo:
O contínuo crescimento da população mundial aumenta a demanda e a competição por energia, colocando grande esforço sobre as fontes de energia não renováveis existentes. Devido a isso, políticas globais para geração de energias renováveis e menos poluentes estão sendo fortalecidas, além de promoverem o desenvolvimento de novas tecnologias. Várias formas de conversão de energia foram desenvolvidas no decorrer dos anos, com destaque para os conversores de energia das correntes a base de turbinas, que demonstram alta capacidade de conversão energética e já se encontram em funcionamento. O modelo tridimensional TELEMAC3D foi utilizado para a investigação dos processos hidrodinâmicos. Este modelo foi acoplado ao módulo de conversão de energia para as análises nos locais de maior viabilidade e conversão energética na Plataforma Continental do Sul do Brasil. A região de estudo demonstrou possuir duas regiões com alto potencial para a exploração da energias das correntes marinhas, entretanto a região mais viável para a instalação de conversores de corrente é a região norte delimitada entre o Farol da Conceição e o Farol da Solidão, podendo atingir potência média de 10kW=Dia, e alcançando valores integrados de 3:5MW=Ano. Através de uma análise da sazonalidade foram observados, durante a primavera os períodos mais energéticos em ambas as regiões estudadas. As maiores intensidades de conversão de energia foram estimadas com variabilidade temporal de 16 dias, demonstrando alta correlação com eventos associados à passagem de frentes meteorológicas na região. O sítio da região norte, com a presença de barreiras que representam a forma dos conversores, se destaca mantendo boa conversão durante os eventos de ótimo potencial energético. Esta melhora se deve ao efeito de intensificação do campo de correntes associado à presença da estrutura física que otimiza a eficiência do sítio. Não foram observadas diferenças significativas no padrão de variabilidade temporal das simulações estudadas, indicando que a presença das barreiras não induz grandes alterações no padrão temporal da conversão de energia nas escalas temporais analisadas neste trabalho. Os eventos de alta geração de energia foram relacionados a incidência de fortes ventos de quadrante sul e norte, indicando que pelo formato e disposição dos conversores, ventos de sudoeste e norte podem favorecer ótimos eventos de conversão de energia. As simulações dos sítios de conversão demonstraram alta capacidade de geração energética, com quatro eventos de extrema geração de energia. Entretanto, o sítio da região norte demonstrou eficiência superior a 59,39 GWh ao ano, equivalendo a 0.22% do consumo energético do estado do Rio Grande do Sul no ano de 2010.
Resumo:
La tendencia mundial de administrar y operar a distancia las centrales hidroeléctricas está obligando a los expertos a replantear los estrategias de monitoreo y diagnóstico de sus máquinas -- Esto ha conducido también, a reducir el personal experto que reside in-situ y que se encarga de operar y mantener los sistemas técnicos, y además de atender cualquier eventualidad que pueda ocurrir -- Por eso, desde hace ya varios años se han venido desarrollando sistemas expertos que puedan suplir las deficiencias del recurso humano -- Pero aunque tales sistemas han alcanzado niveles interesantes de independencia, aún requieren del acompañamiento de un experto que pueda interpretar las evidencias, emitir un diagnóstico y tomar una decisión -- Un ejemplo de los aspectos que aún se deben perfeccionar, es el se las falsas alarmas que llegan a producir el efecto “cry wolf” y que terminan por inactivar el sistema -- Otra forma de enfrentar esta nueva dinámica de operación es la de subcontratar el servicio de diagnóstico técnico, que puede dar resultados aceptables, pero no siempre en el caso de centrales hidroeléctricas -- Las centrales por lo general se encuentran en sitios remotos y en ocasiones blindadas por condiciones geográficas y climatológicas por lo que no es posible reaccionar rápidamente para atender una eventualidad cuando el experto y sus instrumentos no están cerca -- Una solución que resulta conveniente es de hecho, la centralización de la experticia para los servicios de monitoreo y diagnóstico técnico, soportados por una plataforma portátil e idealmente no-invasiva, que permanezca siempre junto a las máquinas y que pueda ser consultada on-line -- De este modo una cantidad reducida de expertos tendrán acceso permanente a las variables o síntomas que definen el estado técnico de la maquinaria; ellos se encargarán de analizar las señales sintomáticas, evaluar los resultados, emitir juicios y elaborar reportes ejecutivos que finalmente llegarán a manos del administrador o persona encargada de la operación -- Esta alternativa aliviará molestias relacionadas con los procesos de monitoreo y diagnóstico: instrumentación/sensórica, cableado, acondicionamiento de señales, adquisición digital de datos, procesamiento de señales, administración y gestión de equipos, reporte de resultados, recomendaciones, etc. -- Este proyecto propone en dos etapas, el diseño de una plataforma tecnológica que pueda soportar la alternativa mencionada -- En detalle, el diseño de un sistema integrado de adquisición de datos que además de ser portátil, modular y escalable, adecuado para monitoreo de las principales variables de diagnóstico de una central hidroeléctrica; que aunque no incorpore un sistema experto, si ofrece las herramientas de análisis, diagnóstico y toma de decisiones del estado del arte
Resumo:
The mobile water hyacinth, which was produced in growth zones, especially Murchison bay, was mainly exported to three sheltered storage bays (Thruston, Hannington and Waiya). Between 1996 and May 1998, the mobile form of water hyacinth occupied about 800 ha in Thruston bay, 750 ha in Hannington bay and 140 ha in Waiya bay). Biological control weevils and other factors, including localised nutrient depletion, weakened the weed that was confined to the bays and it sunk around October 1998. The settling to the bottom of such huge quantities of organic matter its subsequent decomposition and the debris from this mass was likely to have environmental impacts on biotic communities (e.g. fish and invertebrate), physico-chemical conditions (water quality), and on socio-economic activities (e.g. at fish landings, water abstraction, and hydro-power generation points). Sunken water hyacinth debris could also affect nutrient levels in the water column and lead to reduction in the content of dissolved oxygen. The changes in nutrient dynamics and oxygen levels could affect algal productivity, invertebrate composition and fish communities. Socio-economic impacts of dead sunken weed were expected from debris deposited along the shoreline especially at fish landings, water abstraction and hydropower generation points. Therefore, environmental impact assessment studies were carried out between 1998 and 2002 in selected representative zones of Lake Victoria to identify the effects of the sunken water hyacinth biomass.
Resumo:
Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de energia
Resumo:
The steam turbines play a significant role in global power generation. Especially, research on low pressure (LP) steam turbine stages is of special importance for steam turbine man- ufactures, vendors, power plant owners and the scientific community due to their lower efficiency than the high pressure steam turbine stages. Because of condensation, the last stages of LP turbine experience irreversible thermodynamic losses, aerodynamic losses and erosion in turbine blades. Additionally, an LP steam turbine requires maintenance due to moisture generation, and therefore, it is also affecting on the turbine reliability. Therefore, the design of energy efficient LP steam turbines requires a comprehensive analysis of condensation phenomena and corresponding losses occurring in the steam tur- bine either by experiments or with numerical simulations. The aim of the present work is to apply computational fluid dynamics (CFD) to enhance the existing knowledge and understanding of condensing steam flows and loss mechanisms that occur due to the irre- versible heat and mass transfer during the condensation process in an LP steam turbine. Throughout this work, two commercial CFD codes were used to model non-equilibrium condensing steam flows. The Eulerian-Eulerian approach was utilised in which the mix- ture of vapour and liquid phases was solved by Reynolds-averaged Navier-Stokes equa- tions. The nucleation process was modelled with the classical nucleation theory, and two different droplet growth models were used to predict the droplet growth rate. The flow turbulence was solved by employing the standard k-ε and the shear stress transport k-ω turbulence models. Further, both models were modified and implemented in the CFD codes. The thermodynamic properties of vapour and liquid phases were evaluated with real gas models. In this thesis, various topics, namely the influence of real gas properties, turbulence mod- elling, unsteadiness and the blade trailing edge shape on wet-steam flows, are studied with different convergent-divergent nozzles, turbine stator cascade and 3D turbine stator-rotor stage. The simulated results of this study were evaluated and discussed together with the available experimental data in the literature. The grid independence study revealed that an adequate grid size is required to capture correct trends of condensation phenomena in LP turbine flows. The study shows that accurate real gas properties are important for the precise modelling of non-equilibrium condensing steam flows. The turbulence modelling revealed that the flow expansion and subsequently the rate of formation of liquid droplet nuclei and its growth process were affected by the turbulence modelling. The losses were rather sensitive to turbulence modelling as well. Based on the presented results, it could be observed that the correct computational prediction of wet-steam flows in the LP turbine requires the turbulence to be modelled accurately. The trailing edge shape of the LP turbine blades influenced the liquid droplet formulation, distribution and sizes, and loss generation. The study shows that the semicircular trailing edge shape predicted the smallest droplet sizes. The square trailing edge shape estimated greater losses. The analysis of steady and unsteady calculations of wet-steam flow exhibited that in unsteady simulations, the interaction of wakes in the rotor blade row affected the flow field. The flow unsteadiness influenced the nucleation and droplet growth processes due to the fluctuation in the Wilson point.