904 resultados para Power system stabilization
Resumo:
The consumption of energy on the planet is currently based on fossil fuels. They are responsible for adverse effects on the environment. Renewables propose solutions for this scenario, but must face issues related to the capacity of the power supply. Wind energy offshore emerging as a promising alternative. The speed and stability are greater winds over oceans, but the variability of these may cause inconvenience to the generation of electric power fluctuations. To reduce this, a combination of wind farms geographically distributed was proposed. The greater the distance between them, the lower the correlation between the wind velocity, increasing the likelihood that together achieve more stable power system with less fluctuations in power generation. The efficient use of production capacity of the wind park however, depends on their distribution in marine environments. The objective of this research was to analyze the optimal allocation of wind farms offshore on the east coast of the U.S. by Modern Portfolio Theory. The Modern Portfolio Theory was used so that the process of building portfolios of wind energy offshore contemplate the particularity of intermittency of wind, through calculations of return and risk of the production of wind farms. The research was conducted with 25.934 observations of energy produced by wind farms 11 hypothetical offshore, from the installation of 01 simulated ocean turbine with a capacity of 5 MW. The data show hourly time resolution and covers the period between January 1, 1998 until December 31, 2002. Through the Matlab R software, six were calculated minimum variance portfolios, each for a period of time distinct. Given the inequality of the variability of wind over time, set up four strategies rebalancing to evaluate the performance of the related portfolios, which enabled us to identify the most beneficial to the stability of the wind energy production offshore. The results showed that the production of wind energy for 1998, 1999, 2000 and 2001 should be considered by the portfolio weights calculated for the same periods, respectively. Energy data for 2002 should use the weights derived from the portfolio calculated in the previous time period. Finally, the production of wind energy in the period 1998-2002 should also be weighted by 1/11. It follows therefore that the portfolios found failed to show reduced levels of variability when compared to the individual production of wind farms hypothetical offshore
Resumo:
El sector eléctrico está experimentando cambios importantes tanto a nivel de gestión como a nivel de mercado. Una de las claves que están acelerando este cambio es la penetración cada vez mayor de los Sistemas de Generación Distribuida (DER), que están dando un mayor protagonismo al usuario a la hora de plantear la gestión del sistema eléctrico. La complejidad del escenario que se prevé en un futuro próximo, exige que los equipos de la red tenga la capacidad de interactuar en un sistema mucho más dinámico que en el presente, donde la interfaz de conexión deberá estar dotada de la inteligencia necesaria y capacidad de comunicación para que todo el sistema pueda ser gestionado en su conjunto de manera eficaz. En la actualidad estamos siendo testigos de la transición desde el modelo de sistema eléctrico tradicional hacia un nuevo sistema, activo e inteligente, que se conoce como Smart Grid. En esta tesis se presenta el estudio de un Dispositivo Electrónico Inteligente (IED) orientado a aportar soluciones para las necesidades que la evolución del sistema eléctrico requiere, que sea capaz de integrase en el equipamiento actual y futuro de la red, aportando funcionalidades y por tanto valor añadido a estos sistemas. Para situar las necesidades de estos IED se ha llevado a cabo un amplio estudio de antecedentes, comenzando por analizar la evolución histórica de estos sistemas, las características de la interconexión eléctrica que han de controlar, las diversas funciones y soluciones que deben aportar, llegando finalmente a una revisión del estado del arte actual. Dentro de estos antecedentes, también se lleva a cabo una revisión normativa, a nivel internacional y nacional, necesaria para situarse desde el punto de vista de los distintos requerimientos que deben cumplir estos dispositivos. A continuación se exponen las especificaciones y consideraciones necesarias para su diseño, así como su arquitectura multifuncional. En este punto del trabajo, se proponen algunos enfoques originales en el diseño, relacionados con la arquitectura del IED y cómo deben sincronizarse los datos, dependiendo de la naturaleza de los eventos y las distintas funcionalidades. El desarrollo del sistema continua con el diseño de los diferentes subsistemas que lo componen, donde se presentan algunos algoritmos novedosos, como el enfoque del sistema anti-islanding con detección múltiple ponderada. Diseñada la arquitectura y funciones del IED, se expone el desarrollo de un prototipo basado en una plataforma hardware. Para ello se analizan los requisitos necesarios que debe tener, y se justifica la elección de una plataforma embebida de altas prestaciones que incluye un procesador y una FPGA. El prototipo desarrollado se somete a un protocolo de pruebas de Clase A, según las normas IEC 61000-4-30 e IEC 62586-2, para comprobar la monitorización de parámetros. También se presentan diversas pruebas en las que se han estimado los retardos implicados en los algoritmos relacionados con las protecciones. Finalmente se comenta un escenario de prueba real, dentro del contexto de un proyecto del Plan Nacional de Investigación, donde este prototipo ha sido integrado en un inversor dotándole de la inteligencia necesaria para un futuro contexto Smart Grid.
Resumo:
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2015.
Resumo:
Protective relaying comprehends several procedures and techniques focused on maintaining the power system working safely during and after undesired and abnormal network conditions, mostly caused by faulty events. Overcurrent relay is one of the oldest protective relays, its operation principle is straightforward: when the measured current is greater than a specified magnitude the protection trips; less variables are required from the system in comparison with other protections, causing the overcurrent relay to be the simplest and also the most difficult protection to coordinate; its simplicity is reflected in low implementation, operation, and maintenance cost. The counterpart consists in the increased tripping times offered by this kind of relays mostly before faults located far from their location; this problem can be particularly accentuated when standardized inverse-time curves are used or when only maximum faults are considered to carry out relay coordination. These limitations have caused overcurrent relay to be slowly relegated and replaced by more sophisticated protection principles, it is still widely applied in subtransmission, distribution, and industrial systems. In this work, the use of non standardized inverse-time curves, the model and implementation of optimization algorithms capable to carry out the coordination process, the use of different levels of short circuit currents, and the inclusion of distance relays to replace insensitive overcurrent ones are proposed methodologies focused on the overcurrent relay performance improvement. These techniques may transform the typical overcurrent relay into a more sophisticated one without changing its fundamental principles and advantages. Consequently a more secure and still economical alternative can be obtained, increasing its implementation area
Resumo:
This thesis presents a load sharing method applied in a distributed micro grid system. The goal of this method is to balance the state-of-charge (SoC) of each parallel connected battery and make it possible to detect the average SoC of the system by measuring bus voltage for all connected modules. In this method the reference voltage for each battery converter is adjusted by adding a proportional SoC factor. Under such setting the battery with a higher SoC will output more power, whereas the one with lower SoC gives out less. Therefore the higher SoC battery will use its energy faster than the lower ones, and eventually the SoC and output power of each battery will converge. And because the reference voltage is related to SoC status, the information of the average SoC in this system could be shared for all modules by measuring bus voltage. The SoC balancing speed is related to the SoC droop factors. This SoC-based load sharing control system is analyzed in feasibility and stability. Simulations in MATLAB/Simulink are presented, which indicate that this control scheme could balance the battery SoCs as predicted. The observation of SoC sharing through bus voltage was validated in both software simulation and hardware experiments. It could be of use to non-communicated distributed power system in load shedding and power planning.
Resumo:
Combinatorial optimization is a complex engineering subject. Although formulation often depends on the nature of problems that differs from their setup, design, constraints, and implications, establishing a unifying framework is essential. This dissertation investigates the unique features of three important optimization problems that can span from small-scale design automation to large-scale power system planning: (1) Feeder remote terminal unit (FRTU) planning strategy by considering the cybersecurity of secondary distribution network in electrical distribution grid, (2) physical-level synthesis for microfluidic lab-on-a-chip, and (3) discrete gate sizing in very-large-scale integration (VLSI) circuit. First, an optimization technique by cross entropy is proposed to handle FRTU deployment in primary network considering cybersecurity of secondary distribution network. While it is constrained by monetary budget on the number of deployed FRTUs, the proposed algorithm identi?es pivotal locations of a distribution feeder to install the FRTUs in different time horizons. Then, multi-scale optimization techniques are proposed for digital micro?uidic lab-on-a-chip physical level synthesis. The proposed techniques handle the variation-aware lab-on-a-chip placement and routing co-design while satisfying all constraints, and considering contamination and defect. Last, the first fully polynomial time approximation scheme (FPTAS) is proposed for the delay driven discrete gate sizing problem, which explores the theoretical view since the existing works are heuristics with no performance guarantee. The intellectual contribution of the proposed methods establishes a novel paradigm bridging the gaps between professional communities.
Resumo:
This thesis presents four essays in energy economics. The first essay investigates one of the workhorse models of resource economics, the Hotelling model of an inter-temporally optimizing resource extracting firm. The Hotelling model provides a convincing theory of fundamental concepts like resource scarcity, but very few empirical validations of the model have been conducted. This essay attempts to empirically validate the Hotelling model by first expanding it to include exploration activity and market power and then using a newly constructed data set for the uranium mining industry to test whether a major resource extracting mining firm in the industry is following the theory’s predictions. The results show that the theory is rejected in all considered settings. The second and third essays investigate the difference in market outcomes under spot-market based trade as compared to long-term contract based trade in oligopolistic markets with investments. The second essay investigates analytically the difference in market outcomes in an electricity market setting, showing that investments and consumer welfare may be higher under spot-market based trade than under long-term contracts. The third essay proposes techniques to solve large-scale models of this kind, empirically, by exploring the practicability of this approach in an application to the international metallurgical coal market. The final essay investigates the influence of policy uncertainty on investment decisions. With France debating the role of nuclear technology, this essay analyses how policy uncertainty regarding nuclear power in France may feature in the French and European power sector. Applying a stochastic model for the European power system, the analysis shows that the costs of uncertainty in this particular application are rather low compared to the overall costs of a nuclear phase-out.
Resumo:
Esta tesis pretende demostrar y describir las diferentes características de los montacargas que existen en el mercado, teniendo en cuenta sus ventajas y desventajas, logrando como objetivo analizar la viabilidad de la implementación de los montacargas eléctricos en la industria colombiana a partir de la información brindada sobre las características esenciales de los montacargas eléctricos que hay en el mercado. Así mismo, se quiere mostrar que los montacargas eléctricos generan un ahorro sustancial en comparación con los montacargas convencionales que hay hoy en día en el mercado, logrando así que la industria colombiana reduzca sus gastos en un porcentaje mediante la implementación de las nuevas referencias de montacargas eléctricos los cuales serian una alternativa para las compañías colombianas. Mediante una detallada revisión conceptual, se mostrara la viabilidad de los montacargas eléctricos frente a los otros tipos de montacargas, teniendo como premisa el conocimiento de lo que hoy en día requieren las industrias colombianas, y cumpliendo así con una detallada comparación en donde se enfatice la diferenciación de los montacargas eléctricos con otros tipos que existen y se logre brindar una clara percepción de estos junto con las ventajas de estos vehículos para lograr así brindar mayor información a la industria colombiana sobre las ventajas de la implementación de los montacargas eléctricos en la industria colombiana.
Resumo:
The variability in non-dispatchable power generation raises important challenges to the integration of renewable energy sources into the electricity power grid. This paper provides the coordinated trading of wind and photovoltaic energy to mitigate risks due to the wind and solar power variability, electricity prices, and financial penalties arising out the generation shortfall and surplus. The problem of wind-photovoltaic coordinated trading is formulated as a linear programming problem. The goal is to obtain the optimal bidding strategy that maximizes the total profit. The wind-photovoltaic coordinated operation is modeled and compared with the uncoordinated operation. A comparison of the models and relevant conclusions are drawn from an illustrative case study of the Iberian day-ahead electricity market.
Resumo:
The variability in non-dispatchable power generation raises important challenges to the integration of renewable energy sources into the electricity power grid. This paper provides the coordinated trading of wind and photovoltaic energy assisted by a cyber-physical system for supporting management decisions to mitigate risks due to the wind and solar power variability, electricity prices, and financial penalties arising out the generation shortfall and surplus. The problem of wind-photovoltaic coordinated trading is formulated as a stochastic linear programming problem. The goal is to obtain the optimal bidding strategy that maximizes the total profit. The wind-photovoltaic coordinated operation is modelled and compared with the uncoordinated operation. A comparison of the models and relevant conclusions are drawn from an illustrative case study of the Iberian day-ahead electricity market.
Resumo:
This paper presents a computer application for wind energy bidding in a day-ahead electricity market to better accommodate the variability of the energy source. The computer application is based in a stochastic linear mathematical programming problem. The goal is to obtain the optimal bidding strategy in order to maximize the revenue. Electricity prices and financial penalties for shortfall or surplus energy deliver are modeled. Finally, conclusions are drawn from an illustrative case study, using data from the day-ahead electricity market of the Iberian Peninsula.
Resumo:
Evolution of the traditional consumer in a power system to a prosumer has posed many problems in the traditional uni-directional grid. This evolution in the grid model has made it important to study the behaviour of microgrids. This thesis deals with the laboratory microgrid setup at the Munich School of Engineering, built to assist researchers in studying microgrids. The model is built in Dymola which is a tool for the OpenModelica language. Models for the different components were derived, suiting the purpose of this study. The equivalent parameters were derived from data sheets and other simulation programs such as PSCAD. The parameters were entered into the model grid and tested at steady state, firstly. This yielded satisfactory results that were similar to the reference results from MATPOWER power flow. Furthermore, fault conditions at several buses were simulated to observe the behaviour of the grid under these conditions. Recommendations for further developing this model to include more detailed models for components, such as power electronic converters, were made at the end of the thesis.
Resumo:
The Smart Grid needs a large amount of information to be operated and day by day new information is required to improve the operation performance. It is also fundamental that the available information is reliable and accurate. Therefore, the role of metrology is crucial, especially if applied to the distribution grid monitoring and the electrical assets diagnostics. This dissertation aims at better understanding the sensors and the instrumentation employed by the power system operators in the above-mentioned applications and studying new solutions. Concerning the research on the measurement applied to the electrical asset diagnostics: an innovative drone-based measurement system is proposed for monitoring medium voltage surge arresters. This system is described, and its metrological characterization is presented. On the other hand, the research regarding the measurements applied to the grid monitoring consists of three parts. The first part concerns the metrological characterization of the electronic energy meters’ operation under off-nominal power conditions. Original test procedures have been designed for both frequency and harmonic distortion as influence quantities, aiming at defining realistic scenarios. The second part deals with medium voltage inductive current transformers. An in-depth investigation on their accuracy behavior in presence of harmonic distortion is carried out by applying realistic current waveforms. The accuracy has been evaluated by means of the composite error index and its approximated version. Based on the same test setup, a closed-form expression for the measured current total harmonic distortion uncertainty estimation has been experimentally validated. The metrological characterization of a virtual phasor measurement unit is the subject of the third and last part: first, a calibrator has been designed and the uncertainty associated with its steady-state reference phasor has been evaluated; then this calibrator acted as a reference, and it has been used to characterize the phasor measurement unit implemented within a real-time simulator.
Resumo:
Neueste Entwicklungen in Technologien für dezentrale Energieversorgungsstrukturen, erneuerbare Energien, Großhandelsenergiemarkt, Mini- und Mikronetze, verteilte Intelligenz, sowie Informations- und Datenübertragungstechnologien werden die zukünftige Energiewelt maßgeblich bestimmen. Die derzeitigen Forschungsbemühungen zur Vernutzung aller dieser Technologien bilden die Voraussetzungen für ein zukünftiges, intelligentes Stromnetz. Dieses neue Konzept gründet sich auf die folgenden Säulen: Die Versorgung erfolgt durch dezentrale Erzeugungsanlagen und nicht mehr durch große zentrale Erzeuger; die Steuerung beeinflusst nicht mehr allein die Versorgung sondern ermöglich eine auch aktive Führung des Bedarf; die Eingabeparameter des Systems sind nicht mehr nur mechanische oder elektrische Kenngrößen sondern auch Preissignale; die erneuerbaren Energieträger sind nicht mehr nur angeschlossen, sondern voll ins Energienetz integriert. Die vorgelegte Arbeit fügt sich in dieses neue Konzept des intelligenten Stromnetz ein. Da das zukünftige Stromnetz dezentral konfiguriert sein wird, ist eine Übergangsphase notwendig. Dieser Übergang benötigt Technologien, die alle diese neue Konzepte in die derzeitigen Stromnetze integrieren können. Diese Arbeit beweist, dass ein Mininetz in einem Netzabschnitt mittlerer Größe als netzschützende Element wirken kann. Hierfür wurde ein neues Energiemanagementsystem für Mininetze – das CMS (englisch: Cluster Management System) – entwickelt. Diese CMS funktioniert als eine von ökonomischorientierte Betriebsoptimierung und wirkt wie eine intelligente Last auf das System ein, reagierend auf Preissignale. Sobald wird durch eine Frequenzsenkung eine Überlastung des Systems bemerkt, ändert das Mininetz sein Verhalten und regelt seine Belastung, um die Stabilisierung des Hauptnetzes zu unterstützen. Die Wirksamkeit und die Realisierbarkeit des einwickelten Konzept wurde mit Hilfe von Simulationen und erfolgreichen Laborversuchen bewiesen.
Resumo:
Two different fuzzy approaches to voltage control in electric power distribution systems are introduced in this paper. The real-time controller in each case would act on power transformers equipped with under-load tap changers. Learning systems are employed to turn the voltage-control relays into adaptive devices. The scope of this study has been limited to the power distribution substation, and the voltage measurements and control actions are carried out on the secondary bus. The capacity of fuzzy systems to handle approximate data, together with their unique ability to interpret qualitative information, make it possible to design voltage-control strategies that satisfy the requirements of the Brazilian regulatory bodies and the real concerns of the electric power distribution companies. Fuzzy control systems based on these two strategies have been implemented and the test results were highly satisfactory.