859 resultados para Power quality improvement
Resumo:
Freshwater is extremely precious; but even more precious than freshwater is clean freshwater. From the time that 2/3 of our planet is covered in water, we have contaminated our globe with chemicals that have been used by industrial activities over the last century in a unprecedented way causing harm to humans and wildlife. We have to adopt a new scientific mindset in order to face this problem so to protect this important resource. The Water Framework Directive (European Parliament and the Council, 2000) is a milestone legislative document that transformed the way that water quality monitoring is undertaken across all Member States by introducing the Ecological and Chemical Status. A “good or higher” Ecological Status is expected to be achieved for all waterbodies in Europe by 2015. Yet, most of the European waterbodies, which are determined to be at risk, or of moderate to bad quality, further information will be required so that adequate remediation strategies can be implemented. To date, water quality evaluation is based on five biological components (phytoplankton, macrophytes and benthic algae, macroinvertebrates and fishes) and various hydromorphological and physicochemical elements. The evaluation of the chemical status is principally based on 33 priority substances and on 12 xenobiotics, considered as dangerous for the environment. This approach takes into account only a part of the numerous xenobiotics that can be present in surface waters and could not evidence all the possible causes of ecotoxicological stress that can act in a water section. The mixtures of toxic chemicals may constitute an ecological risk not predictable on the basis of the single component concentration. To improve water quality, sources of contamination and causes of ecological alterations need to be identified. On the other hand, the analysis of the community structure, which is the result of multiple processes, including hydrological constrains and physico-chemical stress, give back only a “photograph” of the actual status of a site without revealing causes and sources of the perturbation. A multidisciplinary approach, able to integrate the information obtained by different methods, such as community structure analysis and eco-genotoxicological studies, could help overcome some of the difficulties in properly identifying the different causes of stress in risk assessment. In synthesis, the river ecological status is the result of a combination of multiple pressures that, for management purposes and quality improvement, have to be disentangled from each other. To reduce actual uncertainty in risk assessment, methods that establish quantitative links between levels of contamination and community alterations are needed. The analysis of macrobenthic invertebrate community structure has been widely used to identify sites subjected to perturbation. Trait-based descriptors of community structure constitute a useful method in ecological risk assessment. The diagnostic capacity of freshwater biomonitoring could be improved by chronic sublethal toxicity testing of water and sediment samples. Requiring an exposure time that covers most of the species’ life cycle, chronic toxicity tests are able to reveal negative effects on life-history traits at contaminant concentrations well below the acute toxicity level. Furthermore, the responses of high-level endpoints (growth, fecundity, mortality) can be integrated in order to evaluate the impact on population’s dynamics, a highly relevant endpoint from the ecological point of view. To gain more accurate information about potential causes and consequences of environmental contamination, the evaluation of adverse effects at physiological, biochemical and genetic level is also needed. The use of different biomarkers and toxicity tests can give information about the sub-lethal and toxic load of environmental compartments. Biomarkers give essential information about the exposure to toxicants, such as endocrine disruptor compounds and genotoxic substances whose negative effects cannot be evidenced by using only high-level toxicological endpoints. The increasing presence of genotoxic pollutants in the environment has caused concern regarding the potential harmful effects of xenobiotics on human health, and interest on the development of new and more sensitive methods for the assessment of mutagenic and cancerogenic risk. Within the WFD, biomarkers and bioassays are regarded as important tools to gain lines of evidence for cause-effect relationship in ecological quality assessment. Despite the scientific community clearly addresses the advantages and necessity of an ecotoxicological approach within the ecological quality assessment, a recent review reports that, more than one decade after the publication of the WFD, only few studies have attempted to integrate ecological water status assessment and biological methods (namely biomarkers or bioassays). None of the fifteen reviewed studies included both biomarkers and bioassays. The integrated approach developed in this PhD Thesis comprises a set of laboratory bioassays (Daphnia magna acute and chronic toxicity tests, Comet Assay and FPG-Comet) newly-developed, modified tacking a cue from standardized existing protocols or applied for freshwater quality testing (ecotoxicological, genotoxicological and toxicogenomic assays), coupled with field investigations on macrobenthic community structures (SPEAR and EBI indexes). Together with the development of new bioassays with Daphnia magna, the feasibility of eco-genotoxicological testing of freshwater and sediment quality with Heterocypris incongruens was evaluated (Comet Assay and a protocol for chronic toxicity). However, the Comet Assay, although standardized, was not applied to freshwater samples due to the lack of sensitivity of this species observed after 24h of exposure to relatively high (and not environmentally relevant) concentrations of reference genotoxicants. Furthermore, this species demonstrated to be unsuitable also for chronic toxicity testing due to the difficult evaluation of fecundity as sub-lethal endpoint of exposure and complications due to its biology and behaviour. The study was applied to a pilot hydrographic sub-Basin, by selecting section subjected to different levels of anthropogenic pressure: this allowed us to establish the reference conditions, to select the most significant endpoints and to evaluate the coherence of the responses of the different lines of evidence (alteration of community structure, eco-genotoxicological responses, alteration of gene expression profiles) and, finally, the diagnostic capacity of the monitoring strategy. Significant correlations were found between the genotoxicological parameter Tail Intensity % (TI%) and macrobenthic community descriptors SPEAR (p<0.001) and EBI (p<0.05), between the genotoxicological parameter describing DNA oxidative stress (ΔTI%) and mean levels of nitrates (p<0.01) and between reproductive impairment (Failed Development % from D. magna chronic bioassays) and TI% (p<0.001) as well as EBI (p<0.001). While correlation among parameters demonstrates a general coherence in the response to increasing impacts, the concomitant ability of each single endpoint to be responsive to specific sources of stress is at the basis of the diagnostic capacity of the integrated approach as demonstrated by stations presenting a mismatch among the different lines of evidence. The chosen set of bioassays, as well as the selected endpoints, are not providing redundant indications on the water quality status but, on the contrary, are contributing with complementary pieces of information about the several stressors that insist simultaneously on a waterbody section providing this monitoring strategy with a solid diagnostic capacity. Our approach should provide opportunities for the integration of biological effects into monitoring programmes for surface water, especially in investigative monitoring. Moreover, it should provide a more realistic assessment of impact and exposure of aquatic organisms to contaminants. Finally this approach should provide an evaluation of drivers of change in biodiversity and its causalities on ecosystem function/services provision, that is the direct and indirect contributions to human well-being.
Resumo:
Innovation is part and parcel of any service in today's environment, so as to remain competitive. Quality improvement in healthcare services is a complex, multi-dimensional task. This study proposes innovation management in healthcare services using a logical framework. A problem tree and an objective tree are developed to identify and mitigate issues and concerns. A logical framework is formulated to develop a plan for implementation and monitoring strategies, potentially creating an environment for continuous quality improvement in a specific unit. We recommend logical framework as a valuable model for innovation management in healthcare services. Copyright © 2006 Inderscience Enterprises Ltd.
Resumo:
There is an increasing need of a model for the process-based performance measurement of multispecialty tertiary care hospitals for quality improvement. Analytic hierarchy process (AHP) is utilized in this study to evolve such a model. Each step in the model was derived by group-discussions and brainstorming sessions among experienced clinicians and managers. This tool was applied to two tertiary care teaching hospitals in Barbados and India. The model enabled identification of specific areas where neither hospital performed very well, and helped to suggest recommendations to improve those areas. AHP is recommended as a valuable tool to measure the process-based performance of multispecialty tertiary care hospitals. © Emerald Group Publishing Limited.
Resumo:
Purpose: To develop a model for the global performance measurement of intensive care units (ICUs) and to apply that model to compare the services for quality improvement. Materials and Methods: Analytic hierarchy process, a multiple-attribute decision-making technique, is used in this study to evolve such a model. The steps consisted of identifying the critical success factors for the best performance of an ICU, identifying subfactors that influence the critical factors, comparing them pairwise, deriving their relative importance and ratings, and calculating the cumulative performance according to the attributes of a given ICU. Every step in the model was derived by group discussions, brainstorming, and consensus among intensivists. Results: The model was applied to 3 ICUs, 1 each in Barbados, Trinidad, and India in tertiary care teaching hospitals of similar setting. The cumulative performance rating of the Barbados ICU was 1.17 when compared with that of Trinidad and Indian ICU, which were 0.82 and 0.75, respectively, showing that the Trinidad and Indian ICUs performed 70% and 64% with respect to Barbados ICU. The model also enabled identifying specific areas where the ICUs did not perform well, which helped to improvise those areas. Conclusions: Analytic hierarchy process is a very useful model to measure the global performance of an ICU. © 2005 Elsevier Inc. All rights reserved.
Resumo:
The simulation of a power system such as the More Electric Aircraft is a complex problem. There are conflicting requirements of the simulation, for example in order to reduce simulation run-times, power ratings that need to be established over long periods of the flight can be calculated using a fairly coarse model, whereas power quality is established over relatively short periods with a detailed model. An important issue is to establish the requirements of the simulation work at an early stage. This paper describes the modelling and simulation strategy adopted for the UK TIMES project, which is looking into the optimisation of the More Electric Aircraft from a system level. Essentially four main requirements of the simulation work have been identified, resulting in four different types of simulation. Each of the simulations is described along with preliminary models and results.
Resumo:
A microcap SPICE circuit-level model of a 12-pulse autotransformer based rectifier for an aircraft fuel-pump motor drive is described. The importance of including the nonlinear magnetising inductance of the interphase transformers is illustrated. Small supply voltage distortions are seen to result in current imbalance in the interphase transformers, degrading the rectifier input current, and may lead to infringement of the power quality specification. The model has been validated for various operating supply voltages, frequencies and output powers, against measurements from a 3.75 kW unit.
Resumo:
The modern grid system or the smart grid is likely to be populated with multiple distributed energy sources, e.g. wind power, PV power, Plug-in Electric Vehicle (PEV). It will also include a variety of linear and nonlinear loads. The intermittent nature of renewable energies like PV, wind turbine and increased penetration of Electric Vehicle (EV) makes the stable operation of utility grid system challenging. In order to ensure a stable operation of the utility grid system and to support smart grid functionalities such as, fault ride-through, frequency response, reactive power support, and mitigation of power quality issues, an energy storage system (ESS) could play an important role. A fast acting bidirectional energy storage system which can rapidly provide and absorb power and/or VARs for a sufficient time is a potentially valuable tool to support this functionality. Battery energy storage systems (BESS) are one of a range suitable energy storage system because it can provide and absorb power for sufficient time as well as able to respond reasonably fast. Conventional BESS already exist on the grid system are made up primarily of new batteries. The cost of these batteries can be high which makes most BESS an expensive solution. In order to assist moving towards a low carbon economy and to reduce battery cost this work aims to research the opportunities for the re-use of batteries after their primary use in low and ultra-low carbon vehicles (EV/HEV) on the electricity grid system. This research aims to develop a new generation of second life battery energy storage systems (SLBESS) which could interface to the low/medium voltage network to provide necessary grid support in a reliable and in cost-effective manner. The reliability/performance of these batteries is not clear, but is almost certainly worse than a new battery. Manufacturers indicate that a mixture of gradual degradation and sudden failure are both possible and failure mechanisms are likely to be related to how hard the batteries were driven inside the vehicle. There are several figures from a number of sources including the DECC (Department of Energy and Climate Control) and Arup and Cenex reports indicate anything from 70,000 to 2.6 million electric and hybrid vehicles on the road by 2020. Once the vehicle battery has degraded to around 70-80% of its capacity it is considered to be at the end of its first life application. This leaves capacity available for a second life at a much cheaper cost than a new BESS Assuming a battery capability of around 5-18kWhr (MHEV 5kWh - BEV 18kWh battery) and approximate 10 year life span, this equates to a projection of battery storage capability available for second life of >1GWhrs by 2025. Moreover, each vehicle manufacturer has different specifications for battery chemistry, number and arrangement of battery cells, capacity, voltage, size etc. To enable research and investment in this area and to maximize the remaining life of these batteries, one of the design challenges is to combine these hybrid batteries into a grid-tie converter where their different performance characteristics, and parameter variation can be catered for and a hot swapping mechanism is available so that as a battery ends it second life, it can be replaced without affecting the overall system operation. This integration of either single types of batteries with vastly different performance capability or a hybrid battery system to a grid-tie 3 energy storage system is different to currently existing work on battery energy storage systems (BESS) which deals with a single type of battery with common characteristics. This thesis addresses and solves the power electronic design challenges in integrating second life hybrid batteries into a grid-tie energy storage unit for the first time. This study details a suitable multi-modular power electronic converter and its various switching strategies which can integrate widely different batteries to a grid-tie inverter irrespective of their characteristics, voltage levels and reliability. The proposed converter provides a high efficiency, enhanced control flexibility and has the capability to operate in different operational modes from the input to output. Designing an appropriate control system for this kind of hybrid battery storage system is also important because of the variation of battery types, differences in characteristics and different levels of degradations. This thesis proposes a generalised distributed power sharing strategy based on weighting function aims to optimally use a set of hybrid batteries according to their relative characteristics while providing the necessary grid support by distributing the power between the batteries. The strategy is adaptive in nature and varies as the individual battery characteristics change in real time as a result of degradation for example. A suitable bidirectional distributed control strategy or a module independent control technique has been developed corresponding to each mode of operation of the proposed modular converter. Stability is an important consideration in control of all power converters and as such this thesis investigates the control stability of the multi-modular converter in detailed. Many controllers use PI/PID based techniques with fixed control parameters. However, this is not found to be suitable from a stability point-of-view. Issues of control stability using this controller type under one of the operating modes has led to the development of an alternative adaptive and nonlinear Lyapunov based control for the modular power converter. Finally, a detailed simulation and experimental validation of the proposed power converter operation, power sharing strategy, proposed control structures and control stability issue have been undertaken using a grid connected laboratory based multi-modular hybrid battery energy storage system prototype. The experimental validation has demonstrated the feasibility of this new energy storage system operation for use in future grid applications.
Resumo:
The involvement of parents in their child’s hospital care has been strongly advocated in paediatric healthcare policy and practice. However, incorporating parental worries about their child’s condition into clinical care can be difficult for both parents and healthcare professionals. Through our “Listening To You” quality improvement project we developed and piloted an innovative approach to listening, incorporating and responding to parental concerns regarding their child’s condition when in hospital. Here we describe the phases of work undertaken to develop our “Listening To You” communications bundle, including a survey, literature review and consultation with parents and staff, before findings from the project evaluation are presented and discussed.
Resumo:
High-volume capacitance is required to buffer the power difference between the input and output ports in single-phase grid-connected photovoltaic inverters, which become an obstacle to high system efficiency and long device lifetime. Furthermore, total harmonic distortion becomes serious when the system runs into low power level. In this study, a comprehensive analysis is introduced for two-stage topology with the consideration of active power, DC-link (DCL) voltage, ripple and capacitance. This study proposed a comprehensive DCL voltage control strategy to minimise the DCL capacitance while maintaining a normal system operation. Furthermore, the proposed control strategy is flexible to be integrated with the pulse-skipping control that significantly improves the power quality at light power conditions. Since the proposed control strategy needs to vary DCL voltage, an active protection scheme is also introduced to prevent any voltage violation across the DCL. The proposed control strategy is evaluated by both simulation and experiments, whose results confirm the system effectiveness.
Resumo:
Previous work has shown that human vision performs spatial integration of luminance contrast energy, where signals are squared and summed (with internal noise) over area at detection threshold. We tested that model here in an experiment using arrays of micro-pattern textures that varied in overall stimulus area and sparseness of their target elements, where the contrast of each element was normalised for sensitivity across the visual field. We found a power-law improvement in performance with stimulus area, and a decrease in sensitivity with sparseness. While the contrast integrator model performed well when target elements constituted 50–100% of the target area (replicating previous results), observers outperformed the model when texture elements were sparser than this. This result required the inclusion of further templates in our model, selective for grids of various regular texture densities. By assuming a MAX operation across these noisy mechanisms the model also accounted for the increase in the slope of the psychometric function that occurred as texture density decreased. Thus, for the first time, mechanisms that are selective for texture density have been revealed at contrast detection threshold. We suggest that these mechanisms have a role to play in the perception of visual textures.
Resumo:
The links between operational practices and performance are well studied in the literature, both theoretically and empirically. However, mostly internal factors are inspected more closely as the basis of operational performance, even if the impact of external, environmental factors is often emphasized. Our research fills a part of this existing gap in the literature. We examine how two environmental factors, market dynamism and competition impact the use of some operational practices (such as quality improvement, product development, automation, etc.) and the resulting operations and business performance. The method of path analysis is used. Data were acquired through an international survey (IMSS – International Manufacturing Strategy Survey), which was executed in 2005, in 23 participating countries in so called "innovative" industries (ISIC 28-35) with a sample of 711 firms. Results show that both market dynamism and competition have large impact on business performance, but the indirect effects, through operations practices are rather weak compared to direct ones. The most influential practices are from the area of process and control, and quality management.
Resumo:
The Mara River in East Africa is currently experiencing poor water quality and increased fluctuations in seasonal flow. This study investigated technically effective and economically viable Best Management Practices for adoption in the Mara River Basin of Kenya that can stop further water resources degradation. A survey of 155 farmers was conducted in the upper catchment of the Kenyan side of the river basin. Farmers provided their assessment of BMPs that would best suit their farm in terms of water quality improvement, economic feasibility, and technicalsuitability. Cost data on different practices from farmers and published literature was collected. The results indicated that erosion control structures and runoff management practices were most suitable for adoption. The study estimated the total area that would be improved to restore water quality and reduce further water resources degradation. Farmers were found to incur losses from adopting new practices and would therefore require monetary support.
Resumo:
The purpose of this research is to explore on a deeper level the healthcare system of the United States, its background, and other factors that could provide possible solutions to simplify the fragmented healthcare system. The ultimate goal is the formation of concise ideas that could make the system, which prevents millions of Americans from obtaining adequate medical attention, substantially better. The paper will offer a better insight into the four different models of healthcare insurance found around the world in other developed countries with the purpose of establishing a comparison with that of the United States. The changes implemented by the Patient Protection and Affordable Care Act of 2010 are also analyzed to arrive at the conclusion of whether it has helped more American citizens get access to medical attention. Quality Improvement tools and thorough analysis of different methods from a financial, managerial, legal, and administrative perspective are used to provide valuable information that could aid in the implementation of modifications to the healthcare system of the United States in the near future.
Resumo:
The goal of the power monitoring in electrical power systems is to promote the reliablility as well as the quality of electrical power.Therefore, this dissertation proposes a new theory of power based on wavelet transform for real-time estimation of RMS voltages and currents, and some power amounts, such as active power, reactive power, apparent power, and power factor. The appropriate estimation the of RMS and power values is important for many applications, such as: design and analysis of power systems, compensation devices for improving power quality, and instruments for energy measuring. Simulation and experimental results obtained through the proposed MaximalOverlap Discrete Wavelet Transform-based method were compared with the IEEE Standard 1459-2010 and the commercial oscilloscope, respectively, presenting equivalent results. The proposed method presented good performance for compact mother wavelet, which is in accordance with real-time applications.
Resumo:
Generation systems, using renewable sources, are becoming increasingly popular due to the need for increased use of electricity. Currently, renewables sources have a role to cooperate with conventional generation, due to the system limitation in delivering the required power, the need for reduction of unwanted effects from sources that use fossil fuels (pollution) and the difficulty of building new transmission and/or distribution lines. This cooperation takes place through distributed generation. Therefore, this work proposes a control strategy for the interconnection of a PV (Photovoltaic) system generation distributed with a three-phase power grid through a connection filter the type LCL. The compensation of power quality at point of common coupling (PCC) is performed ensuring that the mains supply or consume only active power and that his currents have low distorcion. Unlike traditional techniques which require schemes for harmonic detection, the technique performs the harmonic compensation without the use of this schemes, controlling the output currents of the system in an indirect way. So that there is effective control of the DC (Direct Current) bus voltage is used the robust controller mode dual DSMPI (Dual-Sliding Mode-Proportional Integral), that behaves as a sliding mode controller SM-PI (Sliding Mode-Proportional Integral) during the transition and like a conventional PI (Proportional Integral) in the steady-state. For control of current is used to repetitive control strategy, which are used double sequence controllers (DSC) tuned to the fundamental component, the fifth and seventh harmonic. The output phase current are aligned with the phase angle of the utility voltage vector obtained from the use of a SRF-PLL (Synchronous Reference Frame Phase-Locked-Loop). In order to obtain the maximum power from the PV array is used a MPPT (Maximum Power Point Tracking) algorithm without the need for adding sensors. Experimental results are presented to demonstrate the effectiveness of the proposed control system.