967 resultados para Peak Detector,
Resumo:
We present a search for the standard model (SM) Higgs boson produced in association with a Z boson in 9.7fb -1 of pp̄ collisions collected with the D0 detector at the Fermilab Tevatron Collider at √s=1.96TeV. Selected events contain one reconstructed Z→e +e - or Z→μ +μ - candidate and at least two jets, including at least one jet identified as likely to contain a b quark. To validate the search procedure, we also measure the cross section for ZZ production in the same final state. It is found to be consistent with its SM prediction. We set upper limits on the ZH production cross section times branching ratio for H→bb̄ at the 95% C.L. for Higgs boson masses 90≤M H≤150GeV. The observed (expected) limit for M H=125GeV is 7.1 (5.1) times the SM cross section. © 2012 American Physical Society.
Resumo:
We present a search for the standard model Higgs boson in final states with a charged lepton (electron or muon), missing transverse energy, and two or three jets, at least one of which is identified as a b-quark jet. The search is primarily sensitive to WH→ νbb̄ production and uses data corresponding to 9.7fb -1 of integrated luminosity collected with the D0 detector at the Fermilab Tevatron pp̄ Collider at √s=1.96TeV. We observe agreement between the data and the expected background. For a Higgs boson mass of 125 GeV, we set a 95% C.L. upper limit on the production of a standard model Higgs boson of 5.2×σ SM, where σ SM is the standard model Higgs boson production cross section, while the expected limit is 4.7×σ SM. © 2012 American Physical Society.
Resumo:
Introduction. In this study we aimed to evaluate the peak cough flow (PCF) in healthy Brazilian subjects. Methods. We evaluated 484 healthy subjects between 18 and 40 years old. Subjects were seated and oriented were asked to perform a maximal inspiration followed by a quick, short and explosive expiration on the peak flow meter. Three measures were carried out and recorded the average of the three results for each individual. Results: The PCF values ranged between 240 and 500 L/min. The PCF values were lower in females than in males. The PCF was inversely proportional to age. Conclusion: The values for Brazilian adult healthy subjects regarding PCF were between 240 and 500 L/min. © 2012 Cardoso et al.; licensee BioMed Central Ltd.
Resumo:
We present a measurement of the semileptonic mixing asymmetry for B0 mesons, asld, using two independent decay channels: B0→μ +D -X, with D -→K +π -π -; and B0→μ +D *-X, with D * -→D ̄0π -, D ̄0→ K +π - (and charge conjugate processes). We use a data sample corresponding to 10.4fb -1 of pp̄ collisions at √s=1.96TeV, collected with the D0 experiment at the Fermilab Tevatron collider. We extract the charge asymmetries in these two channels as a function of the visible proper decay length of the B0 meson, correct for detector-related asymmetries using data-driven methods, and account for dilution from charge-symmetric processes using Monte Carlo simulation. The final measurement combines four signal visible proper decay length regions for each channel, yielding asld=[0.68±0.45(stat)±0.14(syst)]%. This is the single most precise measurement of this parameter, with uncertainties smaller than the current world average of B factory measurements. © 2012 American Physical Society.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Characterization by micro-Raman spectroscopy of polymeric materials used as nuclear track detectors reveals physico-chemical and morphological information on the material's molecular structure. In this work, the nuclear track detector poly(allyl diglycol carbonate), or Columbia Resin 39 (CR-39), was characterized according to the fluence of alpha particles produced by a 226Ra source and chemical etching time. Therefore, damage of the CR-39 chemical structure due to the alpha-particle interaction with the detector was analyzed at the molecular level. It was observed that the ionization and molecular excitation of the CR-39 after the irradiation process entail cleavage of chemical bonds and formation of latent track. In addition, after the chemical etching, there is also loss of polymer structure, leading to the decrease of the group density C-O-C (∼888 cm-1), CH=CH (∼960 cm -1), C-O (∼1110 cm-1), C-O-C (∼1240 cm -1), C-O (∼1290 cm-1), C-O (∼1741 cm -1), -CH2- (∼2910 cm-1), and the main band -CH2- (∼2950 cm-1). The analyses performed after irradiation and chemical etching led to a better understanding of the CR-39 molecular structure and better comprehension of the process of the formation of the track, which is related to chemical etching kinetics. Copyright © 2013 Society for Applied Spectroscopy.
Resumo:
Measurements of inclusive jet and dijet production cross sections are presented. Data from LHC proton-proton collisions at √s=7 TeV, corresponding to 5.0 fb-1 of integrated luminosity, have been collected with the CMS detector. Jets are reconstructed up to rapidity 2.5, transverse momentum 2 TeV, and dijet invariant mass 5 TeV, using the anti-k T clustering algorithm with distance parameter R=0.7. The measured cross sections are corrected for detector effects and compared to perturbative QCD predictions at next-to-leading order, using five sets of parton distribution functions. © 2013 CERN.
Resumo:
It is presented a software developed with Delphi programming language to compute the reservoir's annual regulated active storage, based on the sequent-peak algorithm. Mathematical models used for that purpose generally require extended hydrological series. Usually, the analysis of those series is performed with spreadsheets or graphical representations. Based on that, it was developed a software for calculation of reservoir active capacity. An example calculation is shown by 30-years (from 1977 to 2009) monthly mean flow historical data, from Corrente River, located at São Francisco River Basin, Brazil. As an additional tool, an interface was developed to manage water resources, helping to manipulate data and to point out information that it would be of interest to the user. Moreover, with that interface irrigation districts where water consumption is higher can be analyzed as a function of specific seasonal water demands situations. From a practical application, it is possible to conclude that the program provides the calculation originally proposed. It was designed to keep information organized and retrievable at any time, and to show simulation on seasonal water demands throughout the year, contributing with the elements of study concerning reservoir projects. This program, with its functionality, is an important tool for decision making in the water resources management.
Resumo:
The results of searches for new resonances decaying to a pair of massive vector bosons (WW, WZ, ZZ) are presented. All searches are performed using 5.0 fb-1 of proton-proton collisions, at TeV of center of mass energy, collected by the Compact Muon Solenoid detector at the Large Hadron Collider. No significant excess compared to the standard model background expectation is observed, and upper limits at 95% confidence level are set on the production cross section times the branching fraction of hypothetical particles decaying to a pair of vector bosons. The results are interpreted in the context of several benchmark models, such as the Randall-Sundrum gravitons, the Sequential Standard Model W′, and Technicolor. Graviton resonances in the Randall-Sundrum model with masses smaller than 940 GeV/c2, for coupling parameter k/MPl = 0.05 are excluded. Bulk (ADPS) Randall-Sundrum gravitons with masses smaller than 610 GeV/c2 are excluded, for k/MPl = 0.05. Sequential Standard Model W′ with masses smaller than 1143 GeV/c2 are excluded, as well as ρTC in the 167-687 GeV/c2 mass range, in Low Scale Technicolor models with M(πTC) = 3/4 M(ρTC) - 25 GeV/c2. © 2013 IOP Publishing Ltd.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A determinação das concentrações sanguíneas de antimaláricos empregando métodos rápidos, simples e sensíveis, representa importante ferramenta para otimização dos esquemas terapêuticos adotados atualmente no Brasil. Neste sentido, este trabalho objetivou a validação de uma metodologia analítica por cromatografia líquida de alta eficiência com detecção no ultravioleta para determinação de cloroquina em amostras de sangue total adsorvidas em papel de filtro, oriundas de pacientes com malária vivax. Foram avaliados: precisão intra e inter ensaio, recuperação, limites de detecção e de quantificação, robustez, estabilidade, linearidade e seletividade. Os resultados demonstraram que os coeficientes de variação intra ensaio em concentrações de 100 a 1000 ng/mL variou de 6 a 10% tanto para cloroquina, quanto para desetilcloroquina. Os coeficientes de variação inter ensaio em concentrações de 100 a 1000 ng/mL variaram de 5 a 10% e 4 a 10% para cloroquina e desetilcloroquina, respectivamente. Os limites de detecção foram 62.5ng/mL para cloroquina e 50.0ng/mL para desetilcloroquina e os limites de quantificação foram 100ng/mL para ambos os analitos. A recuperação em concentração de 100 a 1000 ng/mL variou de 90 a 105% e 95 a 105%, para cloroquina e desetilcloroquina, respectivamente. O método foi linear em intervalo de concentração de 100 ng/mL a 2000 para cloroquina e de 100 a 800 ng/mL para desetilcloroquina. O método foi robusto para pequenas variações de fluxo, pH da fase móvel e composição da fase orgânica. Não foram observados interferentes no procedimento validado dentre aqueles fármacos utilizados no tratamento da malária. A determinação de cloroquina e desetilcloroquina em pacientes com malária vivax cujos valores médios foram de 1266±455 ng/mL e 357±165ng/mL, caracterizaram a aplicabilidade do procedimento validado para a determinação deste antimalárico nestes pacientes.
Resumo:
Compreendida por um dispositivo para determinação do espectro de substâncias sólidas e líquidas, com possibilidades de medições in vivo, e exibindo diversas vantagens sobre os dispositivos precedentes, que apresenta uma relação sinalruído excelente e comparável a uma câmara fotoacústica com microfone convencional com a grande vantagem de ser aberta. O dispositivo é composto por um detector transparente de radiação de Tantalato de Lítio, ao qual é acoplada, por contato físico, a amostra a ser analisada. Os eletrodos do detector são em formato de anel, sendo recobertos por uma camada de óxido de índio-estanho (ITO). Ao detector deve ser acoplado um amplificador eletrónico com elevada impedância de entrada.
Resumo:
Pós-graduação em Química - IQ