528 resultados para PLM-järjestelmä


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the biomechanical behavior of different implant connection types, by means of three-dimensional finite element analysis. 3 Three-dimensional models were created with a graphic modeling software: SolidWorks 2006 and Rhinoceros 4.0, and InVesalius (CTI, São Paulo, Brasil), the bone was obtained by computerized tomography of a sagittal section of the molar region. The model was composed by bone block with an implant (4 x 10 mm) (Conexão Sistemas de Prótese, São Paulo), with different implant connections: external hex, internal hex and Morse-taper with the corresponding prosthetic component Ucla or Morse-taper abutment. The Three-dimensional models were transferred to finite element software Femap 10.0 (Siemens PLM Software Inc., CA, USA), to generate a mesh, boundary conditions and loading. An axial (200N) and oblique load (100N) was applied on the occlusal surface of the crowns. Analyses were performed using the finite element software NEiNastran 9.0 (Noran Engineering, Inc., USA) and transferred to the Femap 10.0 to obtain the results; after the results were visualized using von Mises stress maps and Maximum stress principal. The results showed the stress distribution was similar between models, with a little superiority of Morse-taper connection. It was concluded that: the three connection types were biomechanical viable; The Morse-taper connection presented the better internal stress distribution; there was not significant biomechanical differences on the bone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Topical corticosteroids, e.g., dexamethasone acetate (DMA), are extensively used to treat cutaneous inflammatory disorders even though their use is correlated with potential local and systemic side effects. The objective of this study was to develop and test the topical delivery of DMA-loaded surfactant based systems in vitro; these studies could guarantee a suitable delivery and therapeutic efficacy, as well as minimize DMA's side effects. A phase diagram was constructed using polyoxypropylene (5) polyoxyethylene (20) cetyl alcohol as the surfactant (S), isopropyl myristate as the oil phase (O) and water (W). The systems were characterized using polarization light microscopy (PLM), as well as rheological and small angle X-ray scattering (SAXS) measurements. Depending on the concentration of the constituents, it was possible to obtain microemulsions (MEs) and liquid crystalline mesophases (lamellar and hexagonal). These types of arrangement were verified using PLM measurements. The SAXS results revealed that increasing the W/S ratio led to ME, as well as lamellar (LAM) and hexagonal (HEX) arrangements. The MEs displayed typical Newtonian behavior while the LAM and HEX phases exhibited pseudoplasticity and plasticity, respectively. The MEs displayed excellent drug solubilization that was approximately 10-fold higher than was observed with the individual components. The in vitro cutaneous permeation studies using pig ear skin and analysis of the mechanical parameters (hardness, compressibility, cohesiveness and adhesiveness) were carried out with a HEX phase and O/W emulsion. The HEX phase achieved better drug permeation and retention in the skin while its mechanical properties were suitable for skin administration. PPG-5-CETETH-20-based systems may be a promising platform delivering DMA and other topical corticosteroids through the skin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)