976 resultados para Orthodontic mini-implants


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paresthesia of the lower lip is uncommon during orthodontic treatment. In the present case, paresthesia occurred during orthodontic leveling of an extruded mandibular left second molar. It was decided to remove this tooth from the appliance and allow it to relapse. A reanatomization was then performed by grinding. The causes and treatment options of this rare disorder are reviewed and discussed. The main cause of paresthesia during orthodontic treatment may be associated with contact between the dental roots and inferior alveolar nerve, which may be well observed on tomography scans. Treatment usually involves tooth movement in the opposite direction of the cause of the disorder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Craniofacial osseointegrated implants enabled producing implant-retained facial prosthesis, namely the orbital prosthesis. Aim: To evaluate the length and width of the bone structure of the peri-orbital region and to present the method validation. Methods: Computed tomography scans of 30 dry human skulls were obtained in order to register linear length and width measurements of the periorbital region. Two examiners made the measurements twice with intervals of at least 7 days between them. Data were analyzed by descriptive statistics and the paired Student's t-test was used as inferential technique (SAS, α =0.05). Results: In most cases, the intra- and inter-examiner variations were not significant (p>0.05). Therefore, the method proposed was considered as precise and valid for the measurement of the peri-orbital region. The measured points correspond to the hours of a clock. The major lengths were observed at 1 h (18.32 mm) for the left peri-orbital bone and at 11h (19.28 mm) for the right peri-orbital bone, followed by the points situated at 2h (13.05 mm) and 12h (11.37 mm) for the left side and at 10 h (12.34 mm) and 12 h (11.56 mm) for the right side. It was verified that the three points with lowest values followed the same anatomical sequence in the supraorbital rim for the right and left orbits, showing compatibility with the insertion of the intraoral osseointegrated implants. The medial wall of both orbits did not present sufficient length to allow the insertion of intraoral or craniofacial implants. Conclusions: The largest width points were observed in the supraorbital rim and in the infralateral region of both orbits and those of smallest width were found in the supralateral region of both orbits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The following is a clinical case report of a patient whose chief complaint was the presence of generalized spacing in the maxillary anterior segment following orthodontic treatment. After meticulous clinical analyses and discussions of the clinical procedures to be adopted, dental bleaching was performed in both arches with 10% hydrogen peroxide (Opalescence Trèswhite Supreme 10% Hydrogen Peroxide - Ultradent Products, Inc., South Jordan, USA) after the conclusion and stabilization of orthodontic treatment. Then, the orthodontic appliance was removed and the diastemas in the maxillary anterior teeth were closed with Amelogen Plus (Ultradent Products, Inc., South Jordan, USA) resin composite. It was observed that the association of orthodontic, bleaching, and restorative procedures was capable of restoring dental shape, function, and esthetics, allowing the patient to smile without hesitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Bioactive glass and bioactive glass-ceramic cone implants were placed in the rabbit eviscerated socket to assess their biocompatibility. Methods: Fifty-one Norfolk albino rabbits underwent evisceration of the right eye followed by implantation of cones made from Bioglass® 45S5 (control group) and two types of bioactive glass-ceramic (Biosilicate®), a single- and a two-phase bioactive glass-ceramic implants into the scleral cavity. Postoperative reactions, animal behavior and socket conditions were monitored daily. Clinical exam, biochemical evaluations, and orbit computed tomographic scan were done at 7, 90, and 180 days post-procedure. After that, the animals were euthanized, and the orbital content was removed and prepared to light microscopy with morphometric evaluation and scanning electron microscopy examination. Statistical analysis was done by parametric and non-parametric analysis of variance, complemented by Dunn's and Tukey's tests (p<0.05). Results: All animals did not develop systemic toxicity throughout the experimental period and also did not have orbit infection, implant migration or extrusion. Morphological analysis demonstrated pseudocapsule around all implants. Bioglass® and single-phase Biosilicate® implants induced less inflammation and pseudocapsule formation than two-phase Biosilicate® cones. Seven days post-procedure, the inflammatory reaction was intense and gradually decreased throughout the experiment. Tissue reaction was least intense in animals receiving Bioglass® implants. Conclusions: We observe discrete differences among the studied materials, with best responses obtained with use of Bioglass® 45S5 and single-phase Biosilicate®. The authors agree these implants might be useful in the management of the anophthalmic socket. © 2012 Informa Healthcare USA, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The planting of lettuce in greenhouses, as well as covering beds with a polyethylene sheet, is a viable technology, promoting improvements in microclimatic conditions of the environment. In view of the little information on mini-lettuce, the aim of this work was to evaluate the performance of three cultivars of crisp minilettuce ('Green Frizzly', 'Red Frizzly no. 1' and 'Red Frizzly no. 2') with and without ground cover, under different spacings (20 × 15 cm and 20 × 20 cm), in three planting times (1: November 16, 2004; 2: December 17, 2004; and 3: January 20, 2005). The study was conducted in a greenhouse at UNESP-FCAV, Jaboticabal-SP. The experiments were carried out using a randomized block design, following a 3 × 2 × 2 factorial scheme with 12 treatments and three repetitions. The characteristics evaluated were plant height (cm), head diameter (cm), fresh weight (g) and number of leaves per plant. Planting time 3 was shown to be favorable for all the characteristics analyzed. 'Red Frizzly no. 2' was found to be the most suited to planting time 1, and for planting times 2 and 3, this cultivar did not differ from 'Red Frizzly no. 1'. The factor ground cover was not found to affect the characteristics evaluated, and therefore, cultivation without ground cover is recommended. The spacing 20 × 15 cm was shown to be favorable, resulting in cultivation with the highest populations, thereby increasing productivity. Based on the results obtained and for the conditions in which the experiment was conducted, it can be concluded that: planting time 3 (January 20, 2005) was the most favorable; the cultivars 'Red Frizzly no. 2' and 'Red Frizzly no. 1' are adapted to all the planting times; and cultivation without ground cover using a spacing of 20 × 15 cm was the most suitable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Elastomeric materials are considered important sources of orthodontic forces. Objective: To assess force degradation over time of four commercially available orthodontic elastomeric chains (Morelli, Ormco, TP and Unitek). Methods: The synthetic elastics were submerged in 37 oC synthetic saliva and stretched by a force of 150 g (15 mm - Morelli and TP; 16mm - Unitek and Ormco). With a dynamometer, the delivered force was evaluated at different intervals: 30 minutes, 7 days, 14 days and 21 days. The results were subjected to ANOVA and Tukey's test. Results: There was a force decay between 19% to 26.67% after 30 minutes, and 36.67% to 57% after 21 days of activation. Conclusions: TP elastomeric chains exhibited the smallest percentage of force decay, with greater stability at all time intervals tested. Meanwhile, the Unitek chains displayed the highest percentage of force degradation, and no statically significant difference was found in force decay between Ormco and Morelli elastomeric chains during the study period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Incluye Bibliografía

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presenta la coordinación o unión de las expresiones de búsqueda.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tiene por objetivo facilitar al personal de las unidades de información de la Red IPALCA la realización de funciones utilizando el Mini-Micro CDS/ISIS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contiene el procedimiento de instalación del Microisis modificado y del Sistema de Información Bibliográfica de CEPAL para la Red IPALCA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Explica literales y comandos para espaciador horizontal y vertical y otros de los formatos de despliegue del mini-micro CDS/ISIS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contiene ayuda memoria para la exportación de una base, creación de archivo PAR, creación de subdirectorio y copia de archivos para lo cual se requiere tener instalado el Mini Micro ISIS versión 1.0 y 2.3 Red IPALCA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The placement of implants in fresh extraction sockets followed for provisionalization allows soft tissues preservation and alveolar ridge, however for this some requisites are necessary. This article describe the factors involved in immediate implants and the prosthetic approachs for this type of therapy. Addtionaly two clinicals case were presented showing diferents approachs for in prosthetic stage for maintenance the aesthetic aperance of soft tissues of the immediate implants.