775 resultados para Observers
Resumo:
The purpose of the study was to evaluate observer performance in the detection of pneumothorax with cesium iodide and amorphous silicon flat-panel detector radiography (CsI/a-Si FDR) presented as 1K and 3K soft-copy images. Forty patients with and 40 patients without pneumothorax diagnosed on previous and subsequent digital storage phosphor radiography (SPR, gold standard) had follow-up chest radiographs with CsI/a-Si FDR. Four observers confirmed or excluded the diagnosis of pneumothorax according to a five-point scale first on the 1K soft-copy image and then with help of 3K zoom function (1K monitor). Receiver operating characteristic (ROC) analysis was performed for each modality (1K and 3K). The area under the curve (AUC) values for each observer were 0.7815, 0.7779, 0.7946 and 0.7066 with 1K-matrix soft copies and 0.8123, 0.7997, 0.8078 and 0.7522 with 3K zoom. Overall detection of pneumothorax was better with 3K zoom. Differences between the two display methods were not statistically significant in 3 of 4 observers (p-values between 0.13 and 0.44; observer 4: p = 0.02). The detection of pneumothorax with 3K zoom is better than with 1K soft copy but not at a statistically significant level. Differences between both display methods may be subtle. Still, our results indicate that 3K zoom should be employed in clinical practice.
Resumo:
The aim of this study was to compare the effect of an anaesthetic combination given either intramuscularly (IM) or intranasally (IN) for castration of piglets. Forty piglets aged 4 to 7 days were randomly assigned to receive a mixture of ketamine 15 mg kg-1, climazolam 1.5 mg kg-1 and azaperone 1.0 mg kg-1, IN or IM, 10 minutes prior to castration. Physiological parameters were measured. Castration was videotaped for evaluation by 3 independent observers using a scoring system. Reaction and vocalization to the skin incision and cutting of spermatic cord was evaluated and scored (0 = no reaction, 16 = strong reaction). The IN group had a significantly higher (P < 0.01) castration score, compared to the IM group. There was an association between castration score and room temperature in the IN group (with temperatures below 18 "C associated with a higher castration scores (P < 0.001). Heart rate was significantly higher 10 minutes after castration in the IN group (P < 0.05). Respiratory rate was significantly higher in the IM group at time points -5, -1, 10, 20 and 30 (P < 0.05).The IN group was walking significantly (P < 0.0001) faster than the IM group. In conclusion, this combination provides effective anaesthesia for routine castration of newborn piglets when administered IM. IN administration provided shorter recovery times but had significantly higher castration scores.
Resumo:
PURPOSE: To determine sensitivity, specificity and inter-observer variability of different whole-body MRI (WB-MRI) sequences in patients with multiple myeloma (MM). METHODS AND MATERIALS: WB-MRI using a 1.5T MRI scanner was performed in 23 consecutive patients (13 males, 10 females; mean age 63+/-12 years) with histologically proven MM. All patients were clinically classified according to infiltration (low-grade, n=7; intermediate-grade, n=7; high-grade, n=9) and to the staging system of Durie and Salmon PLUS (stage I, n=12; stage II, n=4; stage III, n=7). The control group consisted of 36 individuals without malignancy (25 males, 11 females; mean age 57+/-13 years). Two observers independently evaluated the following WB-MRI sequences: T1w-TSE (T1), T2w-TIRM (T2), and the combination of both sequences, including a contrast-enhanced T1w-TSE with fat-saturation (T1+/-CE/T2). They had to determine growth patterns (focal and/or diffuse) and the MRI sequence that provided the highest confidence level in depicting the MM lesions. Results were calculated on a per-patient basis. RESULTS: Visual detection of MM was as follows: T1, 65% (sensitivity)/85% (specificity); T2, 76%/81%; T1+/-CE/T2, 67%/88%. Inter-observer variability was as follows: T1, 0.3; T2, 0.55; T1+/-CE/T2, 0.55. Sensitivity improved depending on infiltration grade (T1: 1=60%; 2=36%; 3=83%; T2: 1=70%; 2=71%; 3=89%; T1+/-CE/T2: 1=50%; 2=50%; 3=89%) and clinical stage (T1: 1=58%; 2=63%; 3=79%; T2: 1=58%; 2=88%; 3=100%; T1+/-CE/T2: 1=50%; 2=63%; 3=100%). T2w-TIRM sequences achieved the best reliability in depicting the MM lesions (65% in the mean of both readers). CONCLUSIONS: T2w-TIRM sequences achieved the highest level of sensitivity and best reliability, and thus might be valuable for initial assessment of MM. For an exact staging and grading the examination protocol should encompass unenhanced and enhanced T1w-MRI sequences, in addition to T2w-TIRM.
Resumo:
We investigated the effect of image size on saccade amplitudes. First, in a meta-analysis, relevant results from previous scene perception studies are summarised, suggesting the possibility of a linear relationship between mean saccade amplitude and image size. Forty-eight observers viewed 96 colour scene images scaled to four different sizes, while their eye movements were recorded. Mean and median saccade amplitudes were found to be directly proportional to image size, while the mode of the distribution lay in the range of very short saccades. However, saccade amplitudes expressed as percentages of image size were not constant over the different image sizes; on smaller stimulus images, the relative saccades were found to be larger, and vice versa. In sum, and as far as mean and median saccade amplitudes are concerned, the size of stimulus images is the dominant factor. Other factors, such as image properties, viewing task, or measurement equipment, are only of subordinate importance. Thus, the role of stimulus size has to be reconsidered, in theoretical as well as methodological terms.
Resumo:
OBJECTIVE: The aim of this study was to compare the results of tendency-oriented perimetry (TOP) and a dynamic strategy in octopus perimetry as screening methods in clinical practice. DESIGN: A prospective single centre observational case series was performed. PARTICIPANTS AND METHODS: In a newly opened general ophthalmologic practice 89 consecutive patients (171 eyes) with a clinical indication for octopus static perimetry testing (ocular hypertension or suspicious optic nerve cupping) were examined prospectively with TOP and a dynamic strategy. The visual fields were graded by 3 masked observers as normal, borderline or abnormal without any further clinical information. RESULTS: 83% eyes showed the same result for both strategies. In 14% there was a small difference (with one visual field being abnormal or normal, the other being borderline). In only 2.9% of the eyes (5 cases) was there a contradictory result. In 4 out of 5 cases the dynamic visual field was abnormal and TOP was normal. 4 of these cases came back for a second examination. In all 4 the follow-up examination showed a normal second dynamic visual field. CONCLUSIONS: Octopus static perimetry using a TOP strategy is a fast, patient-friendly and very reliable screening tool for the general ophthalmological practice. We found no false-negative results in our series.
Resumo:
Dose reduction in digital panoramic radiography was studied. Intentional underexposure was performed with the Orthophos DS while six different human mandibles were radiographed. Exposure settings were 69 kV/15 mA (standard), 64 kV/16 mA, and 60 kV/16 mA. Standardized spherical defects, each either 1 or 1.25 mm in diameter, were simulated in 288 of 432 images, and seven observers decided whether defects were present or not. Areas under the receiver operating characteristics curves were calculated. They showed no significant differences in the detectability of the 1-mm defect at 69, 64, or 60 kV. For the 1.25-mm defect, no difference was found between the 69 and 60 kV images, but a statistically significant different detectability was found for 64 kV images in comparison with both 69 and 60 kV images. A dose reduction of up to 43% was ascertained with a Pedo-RT-Humanoid phantom when panoramic radiography was performed at 60 kV/16 mA. The conclusion is that with the Orthophos DS, it seems possible to reduce the dose rate of x-rays without loss of diagnostic quality in the case of radiolucent changes.
Resumo:
This article presents a feasibility study with the objective of investigating the potential of multi-detector computed tomography (MDCT) to estimate the bone age and sex of deceased persons. To obtain virtual skeletons, the bodies of 22 deceased persons with known age at death were scanned by MDCT using a special protocol that consisted of high-resolution imaging of the skull, shoulder girdle (including the upper half of the humeri), the symphysis pubis and the upper halves of the femora. Bone and soft-tissue reconstructions were performed in two and three dimensions. The resulting data were investigated by three anthropologists with different professional experience. Sex was determined by investigating three-dimensional models of the skull and pelvis. As a basic orientation for the age estimation, the complex method according to Nemeskéri and co-workers was applied. The final estimation was effected using additional parameters like the state of dentition, degeneration of the spine, etc., which where chosen individually by the three observers according to their experience. The results of the study show that the estimation of sex and age is possible by the use of MDCT. Virtual skeletons present an ideal collection for anthropological studies, because they are obtained in a non-invasive way and can be investigated ad infinitum.
Resumo:
BACKGROUND: Vascular healing of intracoronary stents has been shown to be delayed in drug-eluting stents (DES) due to the cytotoxic compounds on the stent surface that prevent stent ingrowth and endothelialization. The lack of endothelialization explains the occurrence of late and very late stent thrombosis in DES. MATERIALS AND METHODS: In 11 house swines (body weight 38-45 kg), 3 stents were implanted randomly into the 3 large epicardial coronary arteries, namely a bare-metal stent (BMS), a sirolimus-eluting stent with slow-release (SES) and a SES with extended-release (SESXR). Stent length was 18 mm, and stent diameter 3 mm. All stents were of identical design. Animals were followed for 3 (n = 3), 7 (n = 4) and 14 (n = 4) days, respectively. One animal died before implantation due to hyperthermia. On the day of explantation, the animals were euthanized and endothelialization was tested by scanning electron microscopy after drying and sputtering the samples. Endothelial coverage was determined semiquantitatively by 2 observers. RESULTS: Endothelialization was more rapid with BMS and SESXR than SES at 3 and 14 days. At 7 days there were no significant differences between the 2 SES. CONCLUSIONS: Endothelialization of intracoronary stents is faster with BMS and SESXR at 3 days than with SES. These differences persist at 14 days, suggesting delayed vascular healing with the slow-release SES.
Resumo:
OBJECTIVE: The objective of this study was to evaluate the feasibility and reproducibility of high-resolution magnetic resonance imaging (MRI) and quantitative T2 mapping of the talocrural cartilage within a clinically applicable scan time using a new dedicated ankle coil and high-field MRI. MATERIALS AND METHODS: Ten healthy volunteers (mean age 32.4 years) underwent MRI of the ankle. As morphological sequences, proton density fat-suppressed turbo spin echo (PD-FS-TSE), as a reference, was compared with 3D true fast imaging with steady-state precession (TrueFISP). Furthermore, biochemical quantitative T2 imaging was prepared using a multi-echo spin-echo T2 approach. Data analysis was performed three times each by three different observers on sagittal slices, planned on the isotropic 3D-TrueFISP; as a morphological parameter, cartilage thickness was assessed and for T2 relaxation times, region-of-interest (ROI) evaluation was done. Reproducibility was determined as a coefficient of variation (CV) for each volunteer; averaged as root mean square (RMSA) given as a percentage; statistical evaluation was done using analysis of variance. RESULTS: Cartilage thickness of the talocrural joint showed significantly higher values for the 3D-TrueFISP (ranging from 1.07 to 1.14 mm) compared with the PD-FS-TSE (ranging from 0.74 to 0.99 mm); however, both morphological sequences showed comparable good results with RMSA of 7.1 to 8.5%. Regarding quantitative T2 mapping, measurements showed T2 relaxation times of about 54 ms with an excellent reproducibility (RMSA) ranging from 3.2 to 4.7%. CONCLUSION: In our study the assessment of cartilage thickness and T2 relaxation times could be performed with high reproducibility in a clinically realizable scan time, demonstrating new possibilities for further investigations into patient groups.
Resumo:
ntense liver regeneration and almost 100% survival follows partial hepatectomy of up to 70% of liver mass in rodents. More extensive resections of 70 to 80% have an increased mortality and partial hepatectomies of >80% constantly lead to acute hepatic failure and death in mice. The aim of the study was to determine the effect of systemically administered granulocyte colony stimulating factor (G-CSF) on animal survival and liver regeneration in a small for size liver remnant mouse model after 83% partial hepatectomy (liver weight <0.8% of mouse body weight). Methods: Male Balb C mice (n=80, 20-24g) were preconditioned daily for five days with 5μg G-CSF subcutaneously or sham injected (aqua ad inj). Subsequently 83% hepatic resection was performed and daily sham or G-CSF injection continued. Survival was determined in both groups (G-CSF n=35; Sham: n=33). In a second series BrdU was injected (50mg/kg Body weight) two hours prior to tissue harvest and animals euthanized 36 and 48 hours after 83% liver resection (n=3 each group). To measure hepatic regeneration the BrdU labeling index and Ki67 expression were determined by immunohistochemistry by two independent observers. Harvested liver tissue was dried to constant weight at 65 deg C for 48 hours. Results: Survival was 0% in the sham group on day 3 postoperatively and significantly better (26.2% on day 7 and thereafter) in the G-CSF group (Log rank test: p<0.0001). Dry liver weight was increased in the G-CSF group (T-test: p<0.05) 36 hours after 83% partial hepatectomy. Ki67 expression was elevated in the G-CSF group at 36 hours (2.8±2.6% (Standard deviation) vs 0.03±0.2%; Rank sum test: p<0.0001) and at 48 hours (45.1±34.6% vs 0.7±1.0%; Rank sum test: p<0.0001) after 83% liver resection. BrdU labeling at 48 hours was 0.1±0.3% in the sham and 35.2±34.2% in the G-CSF group (Rank sum test: p<0.0001) Conclusions: The surgical 83% resection mouse model is suitable to test hepatic supportive regimens in the setting of small for size liver remnants. Administration of G-CSF supports hepatic regeneration after microsurgical 83% partial hepatectomy and leads to improved long-term survival in the mouse. G-CSF might prove to be a clinically valuable supportive substance in small for size liver remnants in humans after major hepatic resections due to primary or secondary liver tumors or in the setting of living related liver donation.
Resumo:
This study compares MRI and MDCT for endoleak detection after endovascular repair of abdominal aortic aneurysms (EVAR). Forty-three patients with previous EVAR underwent both MRI (2D T1-FFE unenhanced and contrast-enhanced; 3D triphasic contrast-enhanced) and 16-slice MDCT (unenhanced and biphasic contrast-enhanced) within 1 week of each other for endoleak detection. MRI was performed by using a high-relaxivity contrast medium (gadobenate dimeglumine, MultiHance). Two blinded, independent observers evaluated MRI and MDCT separately. Consensus reading of MRI and MDCT studies was defined as reference standard. Sensitivity, specificity, and accuracy were calculated and Cohen's k statistics were used to estimate agreement between readers. Twenty endoleaks were detected in 18 patients at consensus reading (12 type II and 8 indeterminate endoleaks). Sensitivity, specificity, and accuracy for endoleak detection were 100%, 92%, and 96%, respectively, for reader 1 (95%, 81%, 87% for reader 2) for MRI and 55%, 100%, and 80% for reader 1 (60%, 100%, 82% for reader 2) for MDCT. Interobserver agreement was excellent for MDCT (k = 0.96) and good for MRI (k = 0.81). MRI with the use of a high-relaxivity contrast agent is significantly superior in the detection of endoleaks after EVAR compared with MDCT. MRI may therefore become the preferred technique for patient follow-up after EVAR.
Resumo:
BACKGROUND/AIM: To compare the ability of confocal scanning laser tomography (CSLT), scanning laser polarimetry (SLP) and optical coherence tomography (OCT) in recognising localised retinal nerve fibre layer (RNFL) defects. METHODS: 51 eyes from 43 patients with glaucoma were identified by two observers as having RNFL defects visible on optic disc photographs. 51 eyes of 32 normal subjects were used as controls. Three masked observers evaluated CSLT, SLP and OCT images to determine subjectively the presence of localised RNFL defects. RESULTS: Interobserver agreement was highest with OCT, followed by SLP and CSLT (mean kappa: 0.83, 0.69 and 0.64, respectively). RNFL defects were identified in 58.8% of CSLT, 66.7% of SLP and 54.9% of OCT (p = 0.02 between SLP and OCT) by at least two observers. In the controls, 94.1% of CSLT, 84.3% of SLP and 94.1% of OCT scans, respectively, were rated as normal (p = 0.02 between CSLT and SLP, and SLP and OCT). CONCLUSION: Approximately 20-40% of localised RNFL defects identified by colour optic disc photographs are not detected by CSLT, SPL or OCT. SLP showed a higher number of false-positive results than the other techniques, but also had a higher proportion of correctly identified RNFL defects in the glaucoma population.
Resumo:
This dissertation presents a detailed study in exploring quantum correlations of lights in macroscopic environments. We have explored quantum correlations of single photons, weak coherent states, and polarization-correlated/polarization-entangled photons in macroscopic environments. These included macroscopic mirrors, macroscopic photon number, spatially separated observers, noisy photons source and propagation medium with loss or disturbances. We proposed a measurement scheme for observing quantum correlations and entanglement in the spatial properties of two macroscopic mirrors using single photons spatial compass state. We explored the phase space distribution features of spatial compass states, such as chessboard pattern by using the Wigner function. The displacement and tilt correlations of the two mirrors were manifested through the propensities of the compass states. This technique can be used to extract Einstein-Podolsky-Rosen correlations (EPR) of the two mirrors. We then formulated the discrete-like property of the propensity Pb(m,n), which can be used to explore environmental perturbed quantum jumps of the EPR correlations in phase space. With single photons spatial compass state, the variances in position and momentum are much smaller than standard quantum limit when using a Gaussian TEM00 beam. We observed intrinsic quantum correlations of weak coherent states between two parties through balanced homodyne detection. Our scheme can be used as a supplement to decoy-state BB84 protocol and differential phase-shift QKD protocol. We prepared four types of bipartite correlations ±cos2(θ12) that shared between two parties. We also demonstrated bits correlations between two parties separated by 10 km optical fiber. The bits information will be protected by the large quantum phase fluctuation of weak coherent states, adding another physical layer of security to these protocols for quantum key distribution. Using 10 m of highly nonlinear fiber (HNLF) at 77 K, we observed coincidence to accidental-coincidence ratio of 130±5 for correlated photon-pair and Two-Photon Interference visibility >98% entangled photon-pair. We also verified the non-local behavior of polarization-entangled photon pair by violating Clauser-Horne-Shimony-Holt Bell’s inequality by more than 12 standard deviations. With the HNLF at 300 K (77 K), photon-pair production rate about factor 3(2) higher than a 300 m dispersion-shifted fiber is observed. Then, we studied quantum correlation and interference of photon-pairs; with one photon of the photon-air experiencing multiple scattering in a random medium. We observed that depolarization noise photon in multiple scattering degrading the purity of photon-pair, and the existence of Raman noise photon in a photon-pair source will contribute to the depolarization affect. We found that quantum correlation of polarization-entangled photon-pair is better preserved than polarization-correlated photon-pair as one photon of the photon-pair scattered through a random medium. Our findings showed that high purity polarization-entangled photon-pair is better candidate for long distance quantum key distribution.
Resumo:
OBJECTIVE: To study the inter-observer variation related to extraction of continuous and numerical rating scale data from trial reports for use in meta-analyses. DESIGN: Observer agreement study. DATA SOURCES: A random sample of 10 Cochrane reviews that presented a result as a standardised mean difference (SMD), the protocols for the reviews and the trial reports (n=45) were retrieved. DATA EXTRACTION: Five experienced methodologists and five PhD students independently extracted data from the trial reports for calculation of the first SMD result in each review. The observers did not have access to the reviews but to the protocols, where the relevant outcome was highlighted. The agreement was analysed at both trial and meta-analysis level, pairing the observers in all possible ways (45 pairs, yielding 2025 pairs of trials and 450 pairs of meta-analyses). Agreement was defined as SMDs that differed less than 0.1 in their point estimates or confidence intervals. RESULTS: The agreement was 53% at trial level and 31% at meta-analysis level. Including all pairs, the median disagreement was SMD=0.22 (interquartile range 0.07-0.61). The experts agreed somewhat more than the PhD students at trial level (61% v 46%), but not at meta-analysis level. Important reasons for disagreement were differences in selection of time points, scales, control groups, and type of calculations; whether to include a trial in the meta-analysis; and data extraction errors made by the observers. In 14 out of the 100 SMDs calculated at the meta-analysis level, individual observers reached different conclusions than the originally published review. CONCLUSIONS: Disagreements were common and often larger than the effect of commonly used treatments. Meta-analyses using SMDs are prone to observer variation and should be interpreted with caution. The reliability of meta-analyses might be improved by having more detailed review protocols, more than one observer, and statistical expertise.
Resumo:
A popular method for nasolabial rating in unilateral cleft lip and palate (UCLP) is the Asher-McDade system consisting of a 5-point ordinal scale assessing nasal form, nasal symmetry, nasal profile, and vermilion border. The aim of the current study was to identify reference photographs illustrating this scale to facilitate its use.Four observers assessed nasolabial appearance on frontal and profile photographs of the nasolabial area of 42 children of Caucasian origin with a repaired UCLP at age 9 years. Cronbachs alpha, based on the individual scores of the 4 observers, ranged from 0.73 to 0.82 for the 4 nasolabial ratings, indicating a good reliability. The reliability of the overall score (mean of the 4 component scores) was also high (Cronbachs alpha, 0.83). Both for the nasolabial component ratings and for the overall score, duplicate measurement errors were small. The reliability for the mean of the 4 observers' scores was good, Spearman rank correlation coefficients ranging from 0.56 to 0.96.Subsequently, photographs were selected that showed the highest agreement among observers. For each of the 4 components (eg, nasal form, nasal deviation, nasal profile, and shape of the vermilion border), 5 photographs were selected to illustrate the whole range of the scale (score, 1-5), resulting in the selection of 20 pictures.It was concluded that nasolabial appearance rating can be performed reliably using a panel of judges and averaging the scores of all observers. Reference photographs, as developed from this study, may facilitate the rating task.