925 resultados para OPTICAL PERFORMANCE MONITORING


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Translucent WDM optical networks use sparse placement of regenerators to overcome the impairments and wavelength contention introduced by fully transparent networks, and achieve a performance close to fully opaque networks with much less cost. Our previous study proved the feasibility of translucent networks using sparse regeneration technique. We addressed the placement of regenerators based on static schemes allowing only fixed number of regenerators at fixed locations. This paper furthers the study by proposing a suite of dynamical routing schemes. Dynamic allocation, advertisement and discovery of regeneration resources are proposed to support sharing transmitters and receivers between regeneration and access functions. This study follows the current trend in optical networking industry by utilizing extension of IP control protocols. Dynamic routing algorithms, aware of current regeneration resources and link states, are designed to smartly route the connection requests under quality constraints. A hierarchical network model, supported by the MPLS-based control plane, is also proposed to provide scalability. Experiments show that network performance is improved without placement of extra regenerators.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sparse traffic grooming is a practical problem to be addressed in heterogeneous multi-vendor optical WDM networks where only some of the optical cross-connects (OXCs) have grooming capabilities. Such a network is called as a sparse grooming network. The sparse grooming problem under dynamic traffic in optical WDM mesh networks is a relatively unexplored problem. In this work, we propose the maximize-lightpath-sharing multi-hop (MLS-MH) grooming algorithm to support dynamic traffic grooming in sparse grooming networks. We also present an analytical model to evaluate the blocking performance of the MLS-MH algorithm. Simulation results show that MLSMH outperforms an existing grooming algorithm, the shortest path single-hop (SPSH) algorithm. The numerical results from analysis show that it matches closely with the simulation. The effect of the number of grooming nodes in the network on the blocking performance is also analyzed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we consider the problem of topology design for optical networks. We investigate the problem of selecting switching sites to minimize total cost of the optical network. The cost of an optical network can be expressed as a sum of three main factors: the site cost, the link cost, and the switch cost. To the best of our knowledge, this problem has not been studied in its general form as investigated in this paper. We present a mixed integer quadratic programming (MIQP) formulation of the problem to find the optimal value of the total network cost. We also present an efficient heuristic to approximate the solution in polynomial time. The experimental results show good performance of the heuristic. The value of the total network cost computed by the heuristic varies within 2% to 21% of its optimal value in the experiments with 10 nodes. The total network cost computed by the heuristic for 51% of the experiments with 10 node network topologies varies within 8% of its optimal value. We also discuss the insight gained from our experiments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two recently developed instruments, the Laser Optical Plankton Counter (LOPC) and the Zooscan, have been applied to study zooplankton biomass size spectra in tropical and subtropical marine ecosystems off Brazil. Both technologies rely on optical measurements of particles and may potentially be used in zooplankton monitoring programs. Vertical profiles of the LOPC installed in a 200 mu m ring net have been obtained from diverse environmental settings ranging from turbid and nearshore waters to oligotrophic open ocean conditions. Net samples were analyzed on the Zooscan and counted under a microscope. Particle biovolume in the study area estimated with the LOPC correlated with plankton displacement volume from the net samples, but there was no significant relationship between total areal zooplankton biomass determined with LOPC and the Zooscan. Apparently, normalized biomass size spectra (NBSS) of LOPC and Zooscan overlapped for particles in the size range of 500 to 1500 mu m in equivalent spherical diameter (ESD), especially at open ocean stations. However, the distribution of particles into five size classes was statistically different between both instruments at 24 of 28 stations. The disparities arise from unequal flow estimates, from different sampling efficiencies of LOPC tunnel and net for large and small particles, and possibly from the interference of non-zooplankton material in the LOPC signal. Ecosystem properties and technical differences therefore limit the direct comparability of the NBSS slopes obtained with both instruments during this study, and their results should be regarded as complementary.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Obstructive sleep apnea (OSA) is common among patients with coronary artery disease. However, OSA remains largely under recognized. The lack of clinical suspicion and difficulties to access full polysomnography (PSG) are limiting factors. The aim of this study was to evaluate, among patients referred to coronary artery bypass grafting (CABG): (i) the prevalence of OSA, (ii) the association of OSA with clinical symptoms, (iii) the performance of overnight unattended portable monitoring (PM) as an alternative method for the diagnosis of OSA. Methods Consecutive patients referred for CABG were evaluated by standard physical evaluation and validated questionnaires (Berlin questionnaire and Epworth Sleepiness Scale) and underwent full PSG and PM (Stardust II). Results We studied 70 consecutive patients (76% men), age 58 +/- 7 years (mean +/- SD), BMI [median (interquartile range)] 27.6 kg/m(2) (25.8-31.1). The prevalence of OSA (full PSG) using an apnea-hypopnea index of at least 5 events/h was 87%. Commonly used clinical traits for the screening of OSA such as the Epworth Sleepiness Scale and neck circumference had low sensitivities to detect OSA. In contrast, the Berlin questionnaire showed a good sensitivity (72%) to detect OSA. PM showed good sensitivity (92%) and specificity (67%) for the diagnosis of OSA. Conclusion OSA is strikingly common among patients referred for CABG. The Berlin questionnaire, but not symptom of excessive daytime sleepiness is a useful tool to screen OSA. PM is useful for the diagnosis of OSA and therefore is an attractive tool for widespread use among patients with coronary artery disease. Coron Artery Dis 23:31-38 (C) 2011 Wolters Kluwer Health | Lippincott Williams & Wilkins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Moreira, A, McGuigan, MR, Arruda, AFS, Freitas, CG, and Aoki, MS. Monitoring internal load parameters during simulated and official basketball matches. J Strength Cond Res 26(3): 861-866, 2012-The purpose of this study was to compare the internal load responses (session rating of perceived exertion [RPE] and salivary cortisol) between simulated and official matches (SM and OM). Ten professional basketball players participated in 2 OMs and 2 SMs during the competition season. Subjects provided saliva samples 30 minutes before the prematch warm-up (PRE) and 10 minutes after the end of the match. Session RPE (CR-10 scale) was assessed 30 minutes after each match. The results from the 2-way analysis of variance showed significant differences for post-OM salivary cortisol as compared with pre-OM values (p < 0.05). No changes were observed for cortisol during the SM. Before the OM, a significant difference in salivary cortisol was observed as compared with pre-SM values (p < 0.05). Moreover, the OM session RPE was significantly greater than that of SM. There was a significant correlation between session RPE and cortisol changes (r = 0.75). In summary, the results of this study showed a greater magnitude of cortisol and session RPE responses after OM as compared with that after SM confirming the hypothesis that a real competition generates a greater stress response than a simulated condition does. The anticipatory effect was also observed in the OM. In addition, the results indicate that session RPE seems to be a viable tool in monitoring internal loads, and the results are useful in providing a better understanding of internal loads imposed by basketball training and competitions. The precise monitoring of these responses might help the coaches to plan appropriate loads maximizing recovery and performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To determine whether the improvement in intermediate vision after bilateral implantation of an aspheric multifocal intraocular lens (IOL) with a +3.00 diopter (D) addition (add) occurs at the expense of optical quality compared with the previous model with a +4.00 D add. SETTING: Department of Ophthalmology, University of Sao Paulo, Sao Paulo, Brazil. DESIGN: Prospective randomized double-masked comparative clinical trial. METHODS: One year after bilateral implantation of Acrysof Restor SN6AD1 +3.00 D IOLs or Acrysof Restor SN6AD3 +4.00 D IOLs, optical quality was evaluated by analyzing the in vivo modulation transfer function (MTF) and point-spread function (expressed as Strehl ratio). The Strehl ratio and MTF curve with a 4.0 pupil and a 6.0 mm pupil were measured by dynamic retinoscopy aberrometry. The uncorrected and corrected distance visual acuities at 4 m, uncorrected and distance-corrected near visual acuities at 40 cm, and uncorrected and distance-corrected intermediate visual acuities at 50 cm, 60 cm, and 70 cm were measured. RESULTS: Both IOL groups comprised 40 eyes of 20 patients. One year postoperatively, there were no statistically significant between-group differences in the MTF or Strehl ratio with either pupil size. There were no statistically significant between-group differences in distance or near visual acuity. Intermediate visual acuity was significantly better in the +3.00 D IOL group. CONCLUSION: Results indicate that the improvement in intermediate vision in eyes with the aspheric multifocal +3.00 D add IOL occurred without decreasing optical quality over that with the previous version IOL with a +4.00 D add.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The leaf area index (LAI) is a key characteristic of forest ecosystems. Estimations of LAI from satellite images generally rely on spectral vegetation indices (SVIs) or radiative transfer model (RTM) inversions. We have developed a new and precise method suitable for practical application, consisting of building a species-specific SVI that is best-suited to both sensor and vegetation characteristics. Such an SVI requires calibration on a large number of representative vegetation conditions. We developed a two-step approach: (1) estimation of LAI on a subset of satellite data through RTM inversion; and (2) the calibration of a vegetation index on these estimated LAI. We applied this methodology to Eucalyptus plantations which have highly variable LAI in time and space. Previous results showed that an RTM inversion of Moderate Resolution Imaging Spectroradiometer (MODIS) near-infrared and red reflectance allowed good retrieval performance (R-2 = 0.80, RMSE = 0.41), but was computationally difficult. Here, the RTM results were used to calibrate a dedicated vegetation index (called "EucVI") which gave similar LAI retrieval results but in a simpler way. The R-2 of the regression between measured and EucVI-simulated LAI values on a validation dataset was 0.68, and the RMSE was 0.49. The additional use of stand age and day of year in the SVI equation slightly increased the performance of the index (R-2 = 0.77 and RMSE = 0.41). This simple index opens the way to an easily applicable retrieval of Eucalyptus LAI from MODIS data, which could be used in an operational way.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

USE OF THE LINEAR LIGHT SENSOR ILX554 IN OPTICAL SPECTROSCOPY. This technical note describes the construction of a low-cost optical detector. This device is composed by a high-sensitive linear light sensor (model ILX554) and a microcontroller. The performance or the detector was demonstrated by the detection of emission and Raman spectra of the several atomic systems and the results reproduce those found in the literature.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Pierre Auger Observatory is a facility built to detect air showers produced by cosmic rays above 10(17) eV. During clear nights with a low illuminated moon fraction, the UV fluorescence light produced by air showers is recorded by optical telescopes at the Observatory. To correct the observations for variations in atmospheric conditions, atmospheric monitoring is performed at regular intervals ranging from several minutes (for cloud identification) to several hours (for aerosol conditions) to several days (for vertical profiles of temperature, pressure, and humidity). In 2009, the monitoring program was upgraded to allow for additional targeted measurements of atmospheric conditions shortly after the detection of air showers of special interest, e. g., showers produced by very high-energy cosmic rays or showers with atypical longitudinal profiles. The former events are of particular importance for the determination of the energy scale of the Observatory, and the latter are characteristic of unusual air shower physics or exotic primary particle types. The purpose of targeted (or "rapid") monitoring is to improve the resolution of the atmospheric measurements for such events. In this paper, we report on the implementation of the rapid monitoring program and its current status. The rapid monitoring data have been analyzed and applied to the reconstruction of air showers of high interest, and indicate that the air fluorescence measurements affected by clouds and aerosols are effectively corrected using measurements from the regular atmospheric monitoring program. We find that the rapid monitoring program has potential for supporting dedicated physics analyses beyond the standard event reconstruction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to assess the effect of training load regulation, using the CMJ at the beginning of the session, on the total plyometric training load and the vertical jump performance. 44 males were divided into 4 groups: No Regulation Group (nRG), Regulation Group (RG), Yoked Group (YG) and Control Group (CG). The nRG received 6 weeks of plyometric training, with no adjustment in training load. The RG underwent the same training; however, the training load was adjusted according to the CMJ performance at the beginning of each session. The adjustment made in RG was replicated for the volunteers from the corresponding quartile in the YG, with no consideration given to the YG participant's condition at the beginning of its session. At the end of the training, the CMJ and SJ performance of all of the participants was reassessed. The total training load was significantly lower (p=0.036; ES=0.82) in the RG and the YG (1905 +/- 37 jumps) compared to the nRG (1926 +/- 0 jumps). The enhancement in vertical jump performance was significant for the groups that underwent the training (p<0.001). Vertical jump performance, performed at the beginning of the session, as a tool to regulate the training load resulted in a decrease of the total training load, without decreasing the long-term effects on vertical jump performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this article, we present a new control chart for monitoring the covariance matrix in a bivariate process. In this method, n observations of the two variables were considered as if they came from a single variable (as a sample of 2n observations), and a sample variance was calculated. This statistic was used to build a new control chart specifically as a VMIX chart. The performance of the new control chart was compared with its main competitors: the generalized sampled variance chart, the likelihood ratio test, Nagao's test, probability integral transformation (v(t)), and the recently proposed VMAX chart. Among these statistics, only the VMAX chart was competitive with the VMIX chart. For shifts in both variances, the VMIX chart outperformed VMAX; however, VMAX showed better performance for large shifts (higher than 10%) in one variance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work aimed to evaluate the influence of specific operational conditions on the performance of a spiral-wound ultrafiltration pilot plant for direct drinking water treatment, installed at the Guarapiranga's reservoir, in the Sao Paulo Metropolitan Region. Results from operational tests showed that the volume of permeate produced in the combination of periodic relaxation with flushing and chlorine dosage procedures was 49% higher than the volume obtained when these procedures were not used. Two years of continuous operation demonstrated that the ultrafiltration pilot plant performed better during fall and winter seasons, higher permeate flow production and reduced chemical cleanings frequency. Observed behavior seems to be associated with the algae bloom events in the reservoir, which are more frequent during spring and summer seasons, confirmed by chlorophyll-a analysis results. Concentrate clarification using ferric chloride was quite effective in removing NOM and turbidity, allowing its recirculation to the ultrafiltration feed tank. This procedure made it possible to reach almost 99% water recovery considering a single 54-hour recirculation cycle. Water quality monitoring demonstrated that the ultrafiltration pilot plant was quite efficient, and that potential pathogenic organisms, Escherichia coil and total coliforms, turbidity and apparent color removals were 100%, 95.1%, and 91.5%, respectively. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Brazil nut (Bertholletia excelsa) is an important commodity from the Brazilian Amazon, and approximately 37,000 tons (3.36 × 10⁷ kg) of Brazil nuts are harvested each year. However, substantial nut contamination by Aspergillus section Flavi occurs, with subsequent production of mycotoxins. In this context, the objective of the present investigation was to evaluate the presence of fungi and mycotoxins (aflatoxins and cyclopiazonic acid) in 110 stored samples of cultivated Brazil nut (55 samples of nuts and 55 samples of shells) collected monthly for 11 months in Itacoatiara, State of Amazonas, Brazil. The samples were inoculated in duplicate onto Aspergillus flavus and Aspergillus parasiticus agar and potato dextrose agar for the detection of fungi, and the presence of mycotoxins was determined by high-performance liquid chromatography. The most prevalent fungi in nuts and shells were Aspergillus spp., Fusarium spp., and Penicillium spp. A polyphasic approach was used for identification of Aspergillus species. Aflatoxins and cyclopiazonic acid were not detected in any of the samples analyzed. The low water activity of the substrate was a determinant factor for the presence of fungi and the absence of aflatoxin in Brazil nut samples. The high frequency of isolation of aflatoxigenic Aspergillus section Flavi strains, mainly A. flavus, and their persistence during storage increase the chances of aflatoxin production on these substrates and indicates the need for good management practices to prevent mycotoxin contamination in Brazil nuts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

[EN] The accuracy and performance of current variational optical ow methods have considerably increased during the last years. The complexity of these techniques is high and enough care has to be taken for the implementation. The aim of this work is to present a comprehensible implementation of recent variational optical flow methods. We start with an energy model that relies on brightness and gradient constancy terms and a ow-based smoothness term. We minimize this energy model and derive an e cient implicit numerical scheme. In the experimental results, we evaluate the accuracy and performance of this implementation with the Middlebury benchmark database. We show that it is a competitive solution with respect to current methods in the literature. In order to increase the performance, we use a simple strategy to parallelize the execution on multi-core processors.