947 resultados para Non-Newtonian fluid
Resumo:
STUDY QUESTION Is the steroid hormone profile in follicular fluid (FF) at the time of oocyte retrieval different in naturally matured follicles, as in natural cycle IVF (NC-IVF), compared with follicles stimulated with conventional gonadotrophin stimulated IVF (cIVF)? SUMMARY ANSWER Anti-Mullerian hormone (AMH), testosterone (T) and estradiol (E2) concentrations are ∼3-fold higher, androstenedione (A2) is ∼1.5-fold higher and luteinizing hormone (LH) is ∼14-fold higher in NC-IVF than in cIVF follicles, suggesting an alteration of the follicular metabolism in conventional gonadotrophin stimulated IVF. WHAT IS KNOWN ALREADY In conventional IVF, the implantation rate of unselected embryos appears to be lower than in NC-IVF, which is possibly due to negative effects of the stimulation regimen on follicular metabolism. In NC-IVF, the intrafollicular concentration of AMH has been shown to be positively correlated with the oocyte fertilization and implantation rates. Furthermore, androgen treatment seems to improve the ovarian response in low responders. STUDY DESIGN, SIZE, DURATION This cross-sectional study involving 36 NC-IVF and 40 cIVF cycles was performed from 2011 to 2013. Within this population, 13 women each underwent 1 NC-IVF and 1 cIVF cycle. cIVF was performed by controlled ovarian stimulation with HMG and GnRH antagonists. PARTICIPANTS/MATERIALS, SETTING, METHODS Follicular fluid was collected from the leading follicles. AMH, T, A2, dehydroepiandrosterone (DHEA), E2, FSH, LH and progesterone (P) were determined by immunoassays in 76 women. Aromatase activity in follicular fluid cells was analysed by a tritiated water release assay in 33 different women. For statistical analysis, the non-parametric Mann-Whitney U or Wilcoxon tests were used. MAIN RESULTS AND ROLE OF CHANCE In follicular fluid from NC-IVF and from cIVF, median levels were 32.8 and 10.7 pmol/l for AMH (P < 0.0001), 47.2 and 18.8 µmol/l for T (P < 0.0001), 290 and 206 nmol/l for A2 (P = 0.0035), 6.7 and 5.6 pg/ml for DHEA (n.s.), 3292 and 1225 nmol/l for E2 (P < 0.0001), 4.9 and 7.2 mU/ml for FSH (P < 0.05), 14.4 and 0.9 mU/ml for LH (P < 0.0001) and 62 940 and 54 710 nmol/l for P (n.s.), respectively. Significant differences in follicular fluid concentrations for AMH, E2 and LH were also found in the 13 patients who underwent both NC-IVF and cIVF when they were analysed separately in pairs. Hormone analysis in serum excluded any relevant impact of AMH, T, A2, and E2 serum concentration on the follicular fluid hormone concentrations. Median serum concentrations were 29.4 and 0.9 mU/ml for LH (P < 0.0001) and 2.7 and 23.5 nmol/l for P (P < 0.0001) after NC-IVF and c-IVF, respectively. Positive correlations were seen for FF-AMH with FF-T (r = 0.35, P = 0.0002), FF-T with FF-LH (r = 0.48, P < 0.0001) and FF-E2 with FF-T (r = 0.75, P < 0.0001). The analysis of aromatase activity was not different in NC-IVF and cIVF follicular cells. LIMITATION, REASONS FOR CAUTION Any association between the hormone concentrations and the implantation potential of the oocytes could not be investigated as the oocytes in cIVF were not treated individually in the IVF laboratory. Since both c-IVF and NC-IVF follicles were stimulated by hCG before retrieval, the endocrine milieu in the natural cycle does not represent the pure physiological situation. WIDER IMPLICATIONS OF THE FINDINGS The endocrine follicular milieu and the concentration of putative markers of oocyte quality, such as AMH, are significantly different in gonadotrophin-stimulated conventional IVF compared with natural cycle IVF. This could be a cause for the suggested lower oocyte quality in cIVF compared with naturally matured oocytes. The reasons for the reduced AMH concentration might be low serum and follicular fluid LH concentrations due to LH suppression, leading initially to low follicular androgen concentrations and then to low follicular AMH production. STUDY FUNDING/COMPETING INTERESTS Funding for this study was obtained from public universities (for salaries) and private industry (for consumables). Additionally, the study was supported by an unrestricted grant from MSD Merck Sharp & Dohme GmbH and IBSA Institut Biochimique SA. The authors are clinically involved in low-dose monofollicular stimulation and IVF therapies, using gonadotrophins from all gonadotrophin distributors on the Swiss market, including Institut Biochimique SA and MSD Merck Sharp & Dohme GmbH. Otherwise, the authors have no competing interests. TRIAL REGISTRATION NUMBER Not applicable.
Resumo:
We postulated that neuromuscular disuse results in deleteriously affected tissue-vascular fluid exchange processes and subsequently damages the important oxidative bioenergetic process of intramuscular lipid metabolism. The in-depth research reported in the literature is somewhat limited by the ex vivo nature and sporadic time-course characterization of disuse atrophy and recovery. Thus, an in vivo controlled, localized animal model of disuse atrophy was developed in one of the hindlimbs of laboratory rabbits (employing surgically implanted tetrodotoxin (TTX)-filled mini-osmotic pump-sciatic nerve superfusion system) and tested repeatedly with magnetic resonance (MR) throughout the 2-week period of temporarily induced disuse and during the recovery period (following explantation of the TTX-filled pump) for a period of 3 weeks. Controls consisted of saline/"sham"-implanted rabbit hindlimbs. The validity of this model was established with repeated electrophysiologic nerve conduction testing using a clinically appropriate protocol and percutaneously inserted small needle stimulating and recording electrodes. Evoked responses recorded from proximal (P) and distal (D) sites to the sciatic nerve cuff in the TTX-implanted group revealed significantly decreased (p $<$ 0.001) proximal-to-distal (P/D) amplitude ratios (as much as 50-70% below Baseline/pre-implanted and sham-implanted group values) and significantly increased (p $<$ 0.01) differential latency (PL-DL) values (as much as 1.5 times the pre- and sham-implanted groups). By Day 21 of recovery, observed P/D and PL-DL levels matched Baseline/sham-implemented levels. MRI-determined cross-sectional area (CSA) values of Baseline/pre-implanted, sham- or TTX-implanted, and recovering/explanted and the corresponding contralateral hindlimb tibialis anterior (TA) muscles normalized to tibial bone (TB) CSA (in TA/TB ratios) revealed that there was a significant decline (indicative of atrophic response) from pre- and sham-implanted controls by as much as 20% (p $<$ 0.01) at Day 7 and 50-55% (p $<$ 0.001) at Day 13 of TTX-implantation. In the non-implanted contralaterals, a significant increase (indicative of hypertrophic response) by as much as 10% (p $<$ 0.025) at Day 7 and 27% (p $<$ 0.001) at Day 13 + TTX was found. The induced atrophic/hypertrophic TA muscles were observed to be fully recovered by Day 21 post-explantation as evidenced by image TA/TB ratios. End-point biopsy results from a small group of rabbits revealed comprehensive atrophy of both Type I and Type II fibers, although the heterogeneity of the response supports the use of image-guided, volume-localized proton magnetic resonance spectroscopy (MRS) to noninvasively assess tissue-level metabolic changes. MRS-determined results of a 0.25cc volume of tissue within implanted limb TA muscles under resting/pre-ischemic, ischemic-stressed, and post-ischemic conditions at timepoints during and following disuse atrophy/recovery revealed significantly increased intramuscular spectral lipid levels, as much as 2-3 times (p $<$ 0.01) the Baseline/pre-implanted values at Day 7 and 6-7 times (p $<$ 0.001) at Day 13 + TTX, which approached normal levels (compared to pre- and sham-implanted groups) by Day 21 of post-explanation recovery. (Abstract shortened by UMI.) ^
Resumo:
Diagnosis of osteoarthritis (OA) is based upon the clinical orthopaedic examination and the radiographic assessment, both of which can be non-specific and insensitive in early joint disease. The aim of our study was to investigate if there is an increase in serum levels of C-reactive protein (CRP) in degenerative joint disease (DJD) and if CRP could be used to help diagnose OA. We also wished to investigate whether it was possible to distinguish a joint with clinically and radiographically confirmed OA from a healthy joint by comparing lactate dehydrogenase (LDH) levels within the synovial fluid and the serum. We have shown a difference in synovial LDH levels between diseased and healthy joints (P<0.0001). There was also a significant difference between LDH in arthritic synovial fluid and serum, with no correlation between the values. Despite the fact that the values of our clinical patients tended to be higher than the values of our control group (P=0.05) all measured values were within the normal limits of previous publications. From these data, we conclude that single measurements of serum CRP do not permit detection of OA in clinical patients and that serum LDH is not a reliable marker for osteoarthritis. LDH levels in the synovial fluid could be of diagnostic value for identifying osteoarthritis.
Resumo:
We construct the theory of dissipative hydrodynamics of uncharged fluids living on embedded space-time surfaces to first order in a derivative expansion in the case of codimension-1 surfaces (including fluid membranes) and the theory of non-dissipative hydrodynamics to second order in a derivative expansion in the case of codimension higher than one under the assumption of no angular momenta in transverse directions to the surface. This construction includes the elastic degrees of freedom, and hence the corresponding transport coefficients, that take into account transverse fluctuations of the geometry where the fluid lives. Requiring the second law of thermodynamics to be satisfied leads us to conclude that in the case of codimension-1 surfaces the stress-energy tensor is characterized by 2 hydrodynamic and 1 elastic independent transport coefficient to first order in the expansion while for codimension higher than one, and for non-dissipative flows, the stress-energy tensor is characterized by 7 hydrodynamic and 3 elastic independent transport coefficients to second order in the expansion. Furthermore, the constraints imposed between the stress-energy tensor, the bending moment and the entropy current of the fluid by these extra non-dissipative contributions are fully captured by equilibrium partition functions. This analysis constrains the Young modulus which can be measured from gravity by elastically perturbing black branes.
Resumo:
BACKGROUND Bolt-kit systems are increasingly used as an alternative to conventional external cerebrospinal fluid (CSF) drainage systems. Since 2009 we regularly utilize bolt-kit external ventricular drainage (EVD) systems with silver-bearing catheters inserted manually with a hand drill and skull screws for emergency ventriculostomy. For non-emergency situations, we use conventional ventriculostomy with subcutaneous tunneled silver-bearing catheters, performed in the operating room with a pneumatic drill. This retrospective analysis compared the two techniques in terms of infection rates. METHODS 152 patients (aged 17-85 years, mean=55.4 years) were included in the final analysis; 95 received bolt-kit silver-bearing catheters and 57 received conventionally implanted silver-bearing catheters. The primary endpoint combined infection parameters: occurrence of positive CSF culture, colonization of catheter tips, or elevated CSF white blood cell counts (>4/μl). Secondary outcome parameters were presence of microorganisms in CSF or on catheter tips. Incidence of increased CSF cell counts and number of patients with catheter malposition were also compared. RESULTS The primary outcome, defined as analysis of combined infection parameters (occurrence of either positive CSF culture, colonization of the catheter tips or raised CSF white blood cell counts >4/μl)was not significantly different between the groups (58.9% bolt-kit group vs. 63.2% conventionally implanted group, p=0.61, chi-square-test). The bolt-kit group was non-inferior and not superior to the conventional group (relative risk reduction of 6.7%; 90% confidence interval: -19.9% to 25.6%). Secondary outcomes showed no statistically significant difference in the incidence of microorganisms in CSF (2.1% bolt-kit vs. 5.3% conventionally implanted; p=0.30; chi-square-test). CONCLUSIONS This analysis indicates that silver-bearing EVD catheters implanted with a bolt-kit system outside the operating room do not significantly elevate the risk of CSF infection as compared to conventional implant methods.
Resumo:
Cathodoluminescence (CL) studies have previously shown that some secondary fluid inclusions in luminescent quartz are surrounded by dark, non-luminescent patches, resulting from fracture-sealing by late, trace-element-poor quartz. This finding has led to the tacit generalization that all dark CL patches indicate influx of low temperature, late-stage fluids. In this study we have examined natural and synthetic hydrothermal quartz crystals using CL imaging supplemented by in-situ elemental analysis. The results lead us to propose that all natural, liquid-water-bearing inclusions in quartz, whether trapped on former crystal growth surfaces (i.e., of primary origin) or in healed fractures (i.e., of pseudosecondary or secondary origin), are surrounded by three-dimensional, non-luminescent patches. Cross-cutting relations show that the patches form after entrapment of the fluid inclusions and therefore they are not diagnostic of the timing of fluid entrapment. Instead, the dark patches reveal the mechanism by which fluid inclusions spontaneously approach morphological equilibrium and purify their host quartz over geological time. Fluid inclusions that contain solvent water perpetually dissolve and reprecipitate their walls, gradually adopting low-energy euhedral and equant shapes. Defects in the host quartz constitute solubility gradients that drive physical migration of the inclusions over distances of tens of μm (commonly) up to several mm (rarely). Inclusions thus sequester from their walls any trace elements (e.g., Li, Al, Na, Ti) present in excess of equilibrium concentrations, thereby chemically purifying their host crystals in a process analogous to industrial zone refining. Non-luminescent patches of quartz are left in their wake. Fluid inclusions that contain no liquid water as solvent (e.g., inclusions of low-density H2O vapor or other non-aqueous volatiles) do not undergo this process and therefore do not migrate, do not modify their shapes with time, and are not associated with dark-CL zone-refined patches. This new understanding has implications for the interpretation of solids within fluid inclusions (e.g., Ti- and Al-minerals) and for the elemental analysis of hydrothermal and metamorphic quartz and its fluid inclusions by microbeam methods such as LA-ICPMS and SIMS. As Ti is a common trace element in quartz, its sequestration by fluid inclusions and its depletion in zone-refined patches impacts on applications of the Ti-in-quartz geothermometer.
Linear global instability of non-orthogonal incompressible swept attachment-line boundary layer flow
Resumo:
Instability of the orthogonal swept attachment line boundary layer has received attention by local1, 2 and global3–5 analysis methods over several decades, owing to the significance of this model to transition to turbulence on the surface of swept wings. However, substantially less attention has been paid to the problem of laminar flow instability in the non-orthogonal swept attachment-line boundary layer; only a local analysis framework has been employed to-date.6 The present contribution addresses this issue from a linear global (BiGlobal) instability analysis point of view in the incompressible regime. Direct numerical simulations have also been performed in order to verify the analysis results and unravel the limits of validity of the Dorrepaal basic flow7 model analyzed. Cross-validated results document the effect of the angle _ on the critical conditions identified by Hall et al.1 and show linear destabilization of the flow with decreasing AoA, up to a limit at which the assumptions of the Dorrepaal model become questionable. Finally, a simple extension of the extended G¨ortler-H¨ammerlin ODE-based polynomial model proposed by Theofilis et al.4 is presented for the non-orthogonal flow. In this model, the symmetries of the three-dimensional disturbances are broken by the non-orthogonal flow conditions. Temporal and spatial one-dimensional linear eigenvalue codes were developed, obtaining consistent results with BiGlobal stability analysis and DNS. Beyond the computational advantages presented by the ODE-based model, it allows us to understand the functional dependence of the three-dimensional disturbances in the non-orthogonal case as well as their connections with the disturbances of the orthogonal stability problem.
Resumo:
An elliptic computational fluid dynamics wake model based on the actuator disk concept is used to simulate a wind turbine, approximated by a disk upon which a distribution of forces, defined as axial momentum sources, is applied on an incoming non-uniform shear flow. The rotor is supposed to be uniformly loaded with the exerted forces estimated as a function of the incident wind speed, thrust coefficient and rotor diameter. The model is assessed in terms of wind speed deficit and added turbulence intensity for different turbulence models and is validated from experimental measurements of the Sexbierum wind turbine experiment.
Resumo:
Assessing wind conditions on complex terrain has become a hard task as terrain complexity increases. That is why there is a need to extrapolate in a reliable manner some wind parameters that determine wind farms viability such as annual average wind speed at all hub heights as well as turbulence intensities. The development of these tasks began in the early 90´s with the widely used linear model WAsP and WAsP Engineering especially designed for simple terrain with remarkable results on them but not so good on complex orographies. Simultaneously non-linearized Navier Stokes solvers have been rapidly developed in the last decade through CFD (Computational Fluid Dynamics) codes allowing simulating atmospheric boundary layer flows over steep complex terrain more accurately reducing uncertainties. This paper describes the features of these models by validating them through meteorological masts installed in a highly complex terrain. The study compares the results of the mentioned models in terms of wind speed and turbulence intensity.
Resumo:
We review recent computational results for hexagon patterns in non- Boussinesq convection. For sufficiently strong dependence of the fluid parameters on the temperature we find reentrance of steady hexagons, i.e. while near onset the hexagon patterns become unstable to rolls as usually, they become again stable in the strongly nonlinear regime. If the convection apparatus is rotated about a vertical axis the transition from hexagons to rolls is replaced by a Hopf bifurcation to whirling hexagons. For weak non-Boussinesq effects they display defect chaos of the type described by the two-dimensional (2D) complex Ginzburg-andau equation. For stronger non-Boussinesq effects the Hopf bifurcation becomes subcritical and localized bursting of the whirling amplitude is found. In this regime the cou- pling of the whirling amplitude to (small) deformations of the hexagon lattice becomes important. For yet stronger non-Boussinesq effects this coupling breaks up the hexagon lattice and strongly disordered states characterized by whirling and lattice defects are obtained.
Resumo:
While non-Boussinesq hexagonal convection patterns are known to be stable close to threshold (i.e. for Rayleigh numbers R ? Rc ), it has often been assumed that they are always unstable to rolls for slightly higher Rayleigh numbers. Using the incompressible Navier?Stokes equations for parameters corresponding to water as the working fluid, we perform full numerical stability analyses of hexagons in the strongly nonlinear regime ( ? (R ? Rc )/Rc = O(1)). We find ?re-entrant? behaviour of the hexagons, i.e. as is increased they can lose and regain stability. This can occur for values of as low as = 0.2. We identify two factors contributing to the re-entrance: (i) far above threshold there exists a hexagon attractor even in Boussinesq convection as has been shown recently and (ii) the non-Boussinesq effects increase with . Using direct simulations for circular containers we show that the re-entrant hexagons can prevail even for sidewall conditions that favour convection in the form of competing stable rolls. For sufficiently strong non-Boussinesq effects hexagons even become stable over the whole -range considered, 0 6 6 1.5.
Resumo:
Un caloducto en bucle cerrado o Loop Heat Pipe (LHP) es un dispositivo de transferencia de calor cuyo principio de operación se basa en la evaporación/condensación de un fluido de trabajo, que es bombeado a través de un circuito cerrado gracias a fuerzas de capilaridad. Gracias a su flexibilidad, su baja masa y su mínimo (incluso nulo) consumo de potencia, su principal aplicación ha sido identificada como parte del subsistema de control térmico de vehículos espaciales. En el presente trabajo se ha desarrollado un LHP capaz de funcionar eficientemente a temperaturas de hasta 125 oC, siguiendo la actual tendencia de los equipos a bordo de satélites de incrementar su temperatura de operación. En la selección del diseño optimo para dicho LHP, la compatibilidad entre materiales y fluido de trabajo se identificó como uno de los puntos clave. Para seleccionar la mejor combinación, se llevó a cabo una exhaustiva revisión del estado del arte, además de un estudio especifico que incluía el desarrollo de un banco de ensayos de compatibilidad. Como conclusión, la combinación seleccionada como la candidata idónea para ser integrada en el LHP capaz de operar hasta 125 oC fue un evaporador de acero inoxidable, líneas de titanio y amoniaco como fluido de trabajo. En esa línea se diseñó y fabricó un prototipo para ensayos y se desarrolló un modelo de simulación con EcosimPro para evaluar sus prestaciones. Se concluyó que el diseño era adecuado para el rango de operación definido. La incompatibilidad entre el fluido de trabajo y los materiales del LHP está ligada a la generación de gases no condensables. Para un estudio más detallado de los efectos de dichos gases en el funcionamiento del LHP se analizó su comportamiento con diferentes cantidades de nitrógeno inyectadas en su cámara de compensación, simulando un gas no condensable formado en el interior del dispositivo. El estudio se basó en el análisis de las temperaturas medidas experimentalmente a distintos niveles de potencia y temperatura de sumidero o fuente fría. Adicionalmente, dichos resultados se compararon con las predicciones obtenidas por medio del modelo en EcosimPro. Las principales conclusiones obtenidas fueron dos. La primera indica que una cantidad de gas no condensable más de dos veces mayor que la cantidad generada al final de la vida de un satélite típico de telecomunicaciones (15 años) tiene efectos casi despreciables en el funcionamiento del LHP. La segunda es que el principal efecto del gas no condensable es una disminución de la conductancia térmica, especialmente a bajas potencias y temperaturas de sumidero. El efecto es más significativo cuanto mayor es la cantidad de gas añadida. Asimismo, durante la campaña de ensayos se observó un fenómeno no esperado para grandes cantidades de gas no condensable. Dicho fenómeno consiste en un comportamiento oscilatorio, detectado tanto en los ensayos como en la simulación. Este efecto es susceptible de una investigación más profunda y los resultados obtenidos pueden constituir la base para dicha tarea. ABSTRACT Loop Heat Pipes (LHPs) are heat transfer devices whose operating principle is based on the evaporation/condensation of a working fluid, and which use capillary pumping forces to ensure the fluid circulation. Thanks to their flexibility, low mass and minimum (even null) power consumption, their main application has been identified as part of the thermal control subsystem in spacecraft. In the present work, an LHP able to operate efficiently up to 125 oC has been developed, which is in line with the current tendency of satellite on-board equipment to increase their operating temperatures. In selecting the optimal LHP design for the elevated temperature application, the compatibility between the materials and working fluid has been identified as one of the main drivers. An extensive literature review and a dedicated trade-off were performed, in order to select the optimal combination of fluids and materials for the LHP. The trade-off included the development of a dedicated compatibility test stand. In conclusion, the combination of stainless steel evaporator, titanium piping and ammonia as working fluid was selected as the best candidate to operate up to 125 oC. An LHP prototype was designed and manufactured and a simulation model in EcosimPro was developed to evaluate its performance. The first conclusion was that the defined LHP was suitable for the defined operational range. Incompatibility between the working fluid and LHP materials is linked to Non Condensable Gas (NCG) generation. Therefore, the behaviour of the LHP developed with different amounts of nitrogen injected in its compensation chamber to simulate NCG generation, was analyzed. The LHP performance was studied by analysis of the test results at different temperatures and power levels. The test results were also compared to simulations in EcosimPro. Two additional conclusions can be drawn: (i) the effects of an amount of more than two times the expected NCG at the end of life of a typical telecommunications satellite (15 years) is almost negligible on the LHP operation, and (ii) the main effect of the NCG is a decrease in the LHP thermal conductance, especially at low temperatures and low power levels. This decrease is more significant with the progressive addition of NCG. An unexpected phenomenon was observed in the LHP operation with large NCG amounts. Namely, an oscillatory behaviour, which was observed both in the tests and the simulation. This effect provides the basis for further studies concerning oscillations in LHPs.
Resumo:
In this dissertation a new numerical method for solving Fluid-Structure Interaction (FSI) problems in a Lagrangian framework is developed, where solids of different constitutive laws can suffer very large deformations and fluids are considered to be newtonian and incompressible. For that, we first introduce a meshless discretization based on local maximum-entropy interpolants. This allows to discretize a spatial domain with no need of tessellation, avoiding the mesh limitations. Later, the Stokes flow problem is studied. The Galerkin meshless method based on a max-ent scheme for this problem suffers from instabilities, and therefore stabilization techniques are discussed and analyzed. An unconditionally stable method is finally formulated based on a Douglas-Wang stabilization. Then, a Langrangian expression for fluid mechanics is derived. This allows us to establish a common framework for fluid and solid domains, such that interaction can be naturally accounted. The resulting equations are also in the need of stabilization, what is corrected with an analogous technique as for the Stokes problem. The fully Lagrangian framework for fluid/solid interaction is completed with simple point-to-point and point-to-surface contact algorithms. The method is finally validated, and some numerical examples show the potential scope of applications.