957 resultados para Nerve Conduction
Resumo:
Purpose: The objective of this study was to evaluate the position of the mandibular lingula (ML) to provide data for inferior alveolar nerve block techniques in children. Methods: One hundred fifty-four panoramic radiographs of 7- to 10-year-old boys and girls were analyzed. Measurements were taken from the ML to the occlusal plane, and the percentile distances of the ML to ramal borders were determined. Results: The distance between the ML and the occlusal plane showed a gradual increase, but only in the male group was it statistically significant. MLs ratio position on the ramus remained constant in all analyzed groups. In the 7-year-old group, the ML was observed above the occlusal plane in 70% of girls and 55% of boys. That percentage reached 85% of all children by age 10. Conclusions: The mandibular lingula's ratio position remained constant. Inferior alveolar anesthesia should be administered at least 6 mm above the occlusal plane in 7- to 8-year-old children, while 10 mm could be indicated for 9- to 10-year-old children. The mandibular lingula should be considered a reliable reference for further studies of inferior alveolar nerve block techniques.
Resumo:
The effect of Microcurrent Electrical Nerve Stimulation (MENS) was evaluated and compared with occlusal splint therapy in temporomandibular disorders (TMD) patients with muscle pain. Twenty TMD patients were divided into four groups. One received occlusal splint therapy and MENS (I); other received splints and placebo MENS (II); the third, only MENS (III) and the last group, placebo MENS (IV). Sensitivity derived from muscle palpation was evaluated using a visual analogue scale. Results were submitted to analysis of variance (p<0.05). There was reduction of pain level in all groups: group I (occlusal splint and MENS) had a 47.7% reduction rate; group II (occlusal splint and placebo MENS), 66.7%; group III (MENS), 49.7% and group IV (placebo MENS), 16.5%. In spite of that, there was no statistical difference (analysis of variance / p<0.05) between MENS and occlusal splint therapy regarding muscle pain reduction in TMD patients after four weeks.
Resumo:
Purpose: We evaluated the somatic and autonomic innervation of the pelvic floor and rhabdosphincter before and after nerve sparing radical retropubic prostatectomy using neurophysiological tests and correlated findings with clinical parameters and urinary continence. Materials and Methods: From February 2003 to October 2005, 46 patients with prostate cancer were enrolled in a controlled, prospective study. Patients were evaluated before and 6 months after nerve sparing radical retropubic prostatectomy using the UCLA-PCI urinary function domain and neurophysiological tests, including somatosensory evoked potential, and the pudendo-urethral, pudendo-anal and urethro-anal reflexes. Clinical parameters and urinary continence were correlated with afferent and efferent innervation of the membranous urethra and pelvic floor. We used strict criteria to define urinary continence as complete dryness with no leakage at all, not requiring any pads or diapers and with a UCLA-PCI score of 500. Patients with a sporadic drop of leakage, requiring up to 1 pad daily, were defined as having occasional urinary leakage. Results: Two patients were excluded from study due to urethral stricture postoperatively. We evaluated 44 patients within 6 months after surgery. The pudendo-anal and pudendo-urethral reflexes were unchanged postoperatively (p = 0.93 and 0.09, respectively), demonstrating that afferent and efferent pudendal innervation to this pelvic region was not affected by the surgery. Autonomic afferent denervation of the membranous urethral mucosa was found in 34 patients (77.3%), as demonstrated by a postoperative increase in the urethro-anal reflex sensory threshold and urethro-anal reflex latency (p <0.001 and 0.0007, respectively). Six of the 44 patients used pads. One patient with more severe leakage required 3 pads daily and 23 showed urinary leakage, including 5 who needed 1 pad per day and 18 who did not wear pads. Afferent autonomic denervation at the membranous urethral mucosa was found in 91.7% of patients with urinary leakage. Of 10 patients with preserved urethro-anal reflex latency 80% were continent. Conclusions: Sensory and motor pudendal innervation to this specific pelvic region did not change after nerve sparing radical retropubic prostatectomy. Significant autonomic afferent denervation of the membranous urethral mucosa was present in most patients postoperatively. Impaired membranous urethral sensitivity seemed to be associated with urinary incontinence, particularly in patients with occasional urinary leakage. Damage to the afferent autonomic innervation may have a role in the continence mechanism after nerve sparing radical retropubic prostatectomy.
Resumo:
This paper deals with results of a research and development (R&D) project in cooperation with Electric Power Distribution Company in São Paulo (Brazil) regarding the development and experimental analysis of a new concept of power drive system suitable for application in traction systems of electrical vehicles pulled by electrical motors, which can be powered by urban DC or AC distribution networks. The proposed front-end structure is composed by five boost power cells in interleaving connection, operating in discontinuous conduction mode as AC-DC converter, or as DC-DC converter, in order to provide the proper DC output voltage range required by DC or AC adjustable speed drivers. Therefore, when supplied by single-phase AC distribution networks, and operating as AC-DC converter, it is capable to provide high power factor, reduced harmonic distortion in the input current, complying with the restrictions imposed by the IEC 61000-3-4 standards resulting in significant improvements for the trolleybuses systems efficiency and for the urban distribution network costs. Considering the compliance with input current restrictions imposed by IEC 61000-3-4 standards, two digital control strategies were evaluated. The digital controller has been implemented using a low cost FPGA (XC3S200) and developed totally using a hardware description language VHDL and fixed point arithmetic. Experimental results from a 15 kW low power scale prototype operating in DC and AC conditions are presented, in order to verify the feasibility and performance of the proposed system. © 2009 IEEE.
Resumo:
Introduction: Impacted knife injuries in the maxillofacial region are rare and infrequently reported. In cases of injury involving orbit or eye, these reports are even rarer. Discussion: Damage to the orbital contents may result in a rupture of the globe, extraocular muscle injury, lacrimal gland damage, and others. Orbital foreign bodies are not only difficult to detect, and clinical features vary according to its size, characteristics, shape, penetrating method, and site. In this report, a case of abducens nerve palsy after orbitoethmoidal knife injury is presented. © 2010 Springer-Verlag.
Resumo:
The association of unilateral trochlear nerve palsy with Claude Bernard-Horner syndrome represents a rare clinical condition. We present the case of a patient with this unusual presentation. The investigation performed implicated cerebrovascular disease as the underlying cause of the condition in this patient. © 2011 S. Karger AG, Basel.
Resumo:
Understanding the biological activity profile of the snake venom components is fundamental for improving the treatment of snakebite envenomings and may also contribute for the development of new potential therapeutic agents. In this work, we tested the effects of BthTX-I, a Lys49 PLA2 homologue from the Bothrops jararacussu snake venom. While this toxin induces conspicuous myonecrosis by a catalytically independent mechanism, a series of in vitro studies support the hypothesis that BthTX-I might also exert a neuromuscular blocking activity due to its ability to alter the integrity of muscle cell membranes. To gain insight into the mechanisms of this inhibitory neuromuscular effect, for the first time, the influence of BthTX-I on nerve-evoked ACh release was directly quantified by radiochemical and real-time video-microscopy methods. Our results show that the neuromuscular blockade produced by in vitro exposure to BthTX-I (1 μM) results from the summation of both pre- and postsynaptic effects. Modifications affecting the presynaptic apparatus were revealed by the significant reduction of nerve-evoked [3H]-ACh release; real-time measurements of transmitter exocytosis using the FM4-64 fluorescent dye fully supported radiochemical data. The postsynaptic effect of BthTX-I was characterized by typical histological alterations in the architecture of skeletal muscle fibers, increase in the outflow of the intracellular lactate dehydrogenase enzyme and progressive depolarization of the muscle resting membrane potential. In conclusion, these findings suggest that the neuromuscular blockade produced by BthTX-I results from transient depolarization of skeletal muscle fibers, consequent to its general membrane-destabilizing effect, and subsequent decrease of evoked ACh release from motor nerve terminals. © 2012 Elsevier Ltd.
Resumo:
PURPOSE: The present case describes an inferior alveolar nerve lateralization for implant placement that caused mandible fracture a few days after surgery. CLINICAL REPORT: In this case, a 56-year-old female patient who had a severely atrophied jaw and showing bone height less than 7 mm from the bone crest and the mandibular canal was submitted to surgery lateralization of the inferior alveolar conducted with piezzo. Even with all postoperative care, the patient suffered an incomplete fracture of the mandible a few days after lateralization of the inferior alveolar nerve for implant placement. The patient was treated with soft diet and medications for pain and antibiotics, besides removing the implant associated with the fracture. CONCLUSION: It is suggested that this procedure may be conducted in 2 operative periods: firstly, the lateralization of the inferior alveolar; and secondly, after a period of 3 months, the implant placement in a situation of more bone stability. Copyright © 2013 by Mutaz B. Habal, MD.
Resumo:
Purpose: The aim of this prospective study was to objectively evaluate inferior alveolar nerve (IAN) sensory disturbances in patients who underwent sagittal split ramus osteotomy (SSRO) by comparing 1 side treated with a reciprocating saw with the other side treated with a piezosurgery device.Materials and Methods: Clinical evaluation of IAN sensory disturbance was undertaken preoperatively and at 1 week, 4 weeks, 2 months, and 6 months postoperatively in 20 patients who underwent SSROat the Division of Oral and Maxillofacial Surgery, Araraquara Dental School, Sao Paulo State University. The 20 patients were examined at all periods for IAN functionality by Semmes-Weinstein testing; neither the patients nor the examiner knew which side was treated using piezosurgery or a reciprocating saw.Results: The mean age of the patients was 28.4 years (range, 20 to 48 yr). Before surgery, no patient had impaired function of the IAN in any of the 8 zones in the mental and inferior lip areas. All patients reported feeling the first monofilament at the time of the preoperative test. Seven days postoperatively, all patients reported some kind of altered sensitivity in at least 1 zone evaluated.Conclusions: The results of this study suggest there was no statistically significant difference in the sensitivity of the labiomental area regarding the instrument used to perform the osteotomy. Future studies will focus on enlarging the sample and evaluating the results. (C) 2014 American Association of Oral and Maxillofacial Surgeons
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Individuals with facial paralysis of 6 months or more without evidence of clinical or electromyographic improvement have been successfully reanimated utilizing an orthodromic temporalis transfer in conjunction with end-to-side cross-face nerve grafts. The temporalis muscle insertion is released from the coronoid process of the mandible and sutured to a fascia lata graft that is secured distally to the commissure and paralyzed hemilip. The orthodromic transfer of the temporalis muscle overcomes the concave temporal deformity and zygomatic fullness produced by the turning down of the central third of the muscle (Gillies procedure) while yielding stronger muscle contraction and a more symmetric smile. The muscle flap is combined with cross-face sural nerve grafts utilizing end-to-side neurorrhaphies to import myelinated motor fibers to the paralyzed muscles of facial expression in the midface and perioral region. Cross-face nerve grafting provides the potential for true spontaneous facial motion. We feel that the synergy created by the combination of techniques can perhaps produce a more symmetrical and synchronized smile than either procedure in isolation.Nineteen patients underwent an orthodromic temporalis muscle flap in conjunction with cross-face (buccal-buccal with end-to-side neurorrhaphy) nerve grafts. To evaluate the symmetry of the smile, we measured the length of the two hemilips (normal and affected) using the CorelDRAW X3 software. Measurements were obtained in the pre- and postoperative period and compared for symmetry.There was significant improvement in smile symmetry in 89.5 % of patients.Orthodromic temporalis muscle transfer in conjunction with cross face nerve grafts creates a synergistic effect frequently producing an aesthetic, symmetric smile.This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors at www.spinger.com/00266.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Objective: The use of Er:YAG laser operating in the 3 μm range with adjustable power and pulses has become popular for dental and medical practice due to its high photoablative capacity, surgical precision and antimicrobial action. Background data: The existing fiberoptic tips irradiate lasers parallel to the long axes of the tooth limiting its efficiency in the root canal. Methods: We evaluated hollow fiberoptic tips obtained from silicate glass as a means of Er:YAG laser conduction in dental procedures. The fiber tips were molded from capillary tubes with different profiles so that their ends would have cylindric, conical or spherical shapes. The performance of the three fibers as a means of propagation of Er:YAG (λ = 2.94 μm) laser radiation was compared to that of a solid sapphire fiber at 10 Hz and 200 mJ and of 20 Hz and 500 mJ. The profiles of frontal and lateral burning were visualized on thermal paper. Results: Analysis of these profiles demonstrated that the sapphire tip and the hollow fiber of cylindric section did not differ significantly in the profiles of frontal burning, and no lateral burning was detected. The fibers of the conical and spherical sections, although presenting attenuation in the frontal output power, showed a larger burning area in the frontal profile, in addition to producing lateral burning. Conclusions: The results indicate that commercial hollow fiberoptics have advantages such as easy manufacture of the different tip shapes, great adaptability, low cost, and a low loss of transmission. © Mary Ann Liebert, Inc.