960 resultados para Multi-User Detention


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Given the limitations of different types of remote sensing images, automated land-cover classifications of the Amazon várzea may yield poor accuracy indexes. One way to improve accuracy is through the combination of images from different sensors, by either image fusion or multi-sensor classifications. Therefore, the objective of this study was to determine which classification method is more efficient in improving land cover classification accuracies for the Amazon várzea and similar wetland environments - (a) synthetically fused optical and SAR images or (b) multi-sensor classification of paired SAR and optical images. Land cover classifications based on images from a single sensor (Landsat TM or Radarsat-2) are compared with multi-sensor and image fusion classifications. Object-based image analyses (OBIA) and the J.48 data-mining algorithm were used for automated classification, and classification accuracies were assessed using the kappa index of agreement and the recently proposed allocation and quantity disagreement measures. Overall, optical-based classifications had better accuracy than SAR-based classifications. Once both datasets were combined using the multi-sensor approach, there was a 2% decrease in allocation disagreement, as the method was able to overcome part of the limitations present in both images. Accuracy decreased when image fusion methods were used, however. We therefore concluded that the multi-sensor classification method is more appropriate for classifying land cover in the Amazon várzea.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High transverse momentum jets produced in pp collisions at a centre of mass energy of 7 TeV are used to measure the transverse energy--energy correlation function and its associated azimuthal asymmetry. The data were recorded with the ATLAS detector at the LHC in the year 2011 and correspond to an integrated luminosity of 158 pb−1. The selection criteria demand the average transverse momentum of the two leading jets in an event to be larger than 250 GeV. The data at detector level are well described by Monte Carlo event generators. They are unfolded to the particle level and compared with theoretical calculations at next-to-leading-order accuracy. The agreement between data and theory is good and provides a precision test of perturbative Quantum Chromodynamics at large momentum transfers. From this comparison, the strong coupling constant given at the Z boson mass is determined to be αs(mZ)=0.1173±0.0010 (exp.) +0.0065−0.0026 (theo.).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Eletrónica Industrial e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este texto reflexiona sobre una nueva forma de concebir la televisión como servicio público, resaltando las dificultades y problemas que plantea analizar el concepto de la calidad de la televisión, si no se tiene en cuenta la dimensión emotiva y de entretenimiento del medio. Posteriormente, el autor pretende ubicar la televisión en el contexto de la multiplicidad de otras pantallas y tecnologías, subrayando las cuestiones del sentido y de la calidad de vida, desde un modelo ecológico. Finalmente, se apuntan algunas contribuciones para profundizar el concepto y las experiencias de alfabetización digital.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Kinetic models have a great potential for metabolic engineering applications. They can be used for testing which genetic and regulatory modifications can increase the production of metabolites of interest, while simultaneously monitoring other key functions of the host organism. This work presents a methodology for increasing productivity in biotechnological processes exploiting dynamic models. It uses multi-objective dynamic optimization to identify the combination of targets (enzymatic modifications) and the degree of up- or down-regulation that must be performed in order to optimize a set of pre-defined performance metrics subject to process constraints. The capabilities of the approach are demonstrated on a realistic and computationally challenging application: a large-scale metabolic model of Chinese Hamster Ovary cells (CHO), which are used for antibody production in a fed-batch process. The proposed methodology manages to provide a sustained and robust growth in CHO cells, increasing productivity while simultaneously increasing biomass production, product titer, and keeping the concentrations of lactate and ammonia at low values. The approach presented here can be used for optimizing metabolic models by finding the best combination of targets and their optimal level of up/down-regulation. Furthermore, it can accommodate additional trade-offs and constraints with great flexibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

NIPE WP 04/ 2016

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Doctoral Dissertation for PhD degree in Chemical and Biological Engineering

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El objetivo general de este proyecto es desarrollar nuevos modelos multi-dominio de máquinas eléctricas para aplicaciones al control y al diagnóstico de fallas. Se propone comenzar con el modelo electromagnético del motor de inducción en base a circuitos magnéticos equivalentes (MEC) validándolo por medio de simulación y de resultados experimentales. Como segundo paso se pretende desarrollas modelos térmicos y mecánicos con el objetivo que puedan ser acoplados al modelo electromagnético y de esta estudiar la interacción de los dominios y se validará mediante resultados de simulación y experimentales el modelo completo. Finalmente se pretende utilizar el modelo multi-dominio como una herramienta para la prueba de nuevas estrategias de control y diagnóstico de fallas. The main objective of this project is the development of new multi-domain models of electric machines for control and fault diagnosis applications. The electromagnetic modeling of the induction motor (IM) will be done using the magnetic equivalent circuits approach. This model will be validated by simulation and by experimental results. As a second step of this project, new mechanical and thermal models for the IM will be developed, with the objective of coupling these models with the electromagnetic one. With this multi-domain model it will be possible to study the interaction between each others. After that, the complete model will be validated by simulation and experimental results. Finally, the model will be used as a tool for testing new control and fault diagnosis strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundamento: A doença cardiovascular subclínica é prevalente em pacientes com síndrome metabólica (SM). O strain circunferencial (εCC) e o strain longitudinal (εLL) do ventriculo esquerdo (VE), avaliados pelo ecocardiograma com speckle tracking (STE), são índices de função sistólica: o encurtamento das fibras circunferenciais e longitudinais do VE é indicado por um valor negativo do strain. Portanto, quanto mais negativo o strain, melhor a função sistólica do VE. O εCC e o εLL têm sido usados para demonstrar disfunção ventricular subclínica em vários distúrbios clínicos. Objetivo: Levantamos a hipótese de que a SM está associada com comprometimento da função miocárdica, quando avaliada pelo STE. Métodos: Este estudo analisou participantes do Multi-Ethnic Study of Atherosclerosis (MESA) que realizaram o STE e foram avaliados para todos os componentes da SM. Resultados: Entre os 133 participantes incluídos (mulheres: 63%; idade: 65 ± 9 anos), a prevalência de SM foi de 31% (41/133). Indivíduos com SM apresentaram valores menores do εCC e do εLL que aqueles sem SM (-16,3% ± 3,5% vs. -18,4% ± 3,7%, p < 0,01; e -12,1% ± 2,5% vs. -13,9% ± 2,3%, p < 0,01, respectivamente). A fração de ejeção do VE (FEVE) foi semelhante nos dois grupos (p = 0,09). Na análise multivariada, a SM associou-se a um valor mais baixo do strain circunferencial (B = 2,1%, IC 95%: 0,6-3,5; p < 0,01), mesmo após ajuste para idade, etnia, massa VE e FEVE. De maneira semelhante, a presença de SM (B = 1,3%, IC 95%: 0,3-2,2; p < 0,01) e a massa do VE (B = 0,02%, IC 95%: 0,01 0,03; p = 0,02) associaram-se a um valor menor do strain longitudinal após ajuste para etnia, FEVE e creatinina. Conclusão: O εCC e o εLL do VE, marcadores de doença cardiovascular subclínica, estão comprometidos em indivíduos assintomáticos com SM e sem história prévia de infarto miocárdico, insuficiência cardíaca e/ou de FEVE < 50%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zugl.: Magdeburg, Univ., Fak. für Informatik, Diss., 2011

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Wirtschaftswiss., Diss., 2013

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Elektrotechnik und Informationstechnik, Diss., 2013

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multi-core processors is a design philosophy that has become mainstream in scientific and engineering applications. Increasing performance and gate capacity of recent FPGA devices has permitted complex logic systems to be implemented on a single programmable device. By using VHDL here we present an implementation of one multi-core processor by using the PLASMA IP core based on the (most) MIPS I ISA and give an overview of the processor architecture and share theexecution results.