795 resultados para Microstructure parameters


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: To compare the prognostic value of different anatomical and functional metabolic parameters determined using [(18)F]FDG-PET/CT with other clinical and pathological prognostic parameters in cervical cancer (CC). METHODS: Thirty-eight patients treated with standard curative doses of chemo-radiotherapy (CRT) underwent pre- and post-therapy [(18)F]FDG-PET/CT. [(18)F]FDG-PET/CT parameters including mean tumor standardized uptake values (SUV), metabolic tumor volume (MTV) and tumor glycolytic volume (TGV) were measured before the start of CRT. The post-treatment tumor metabolic response was evaluated. These parameters were compared to other clinical prognostic factors. Survival curves were estimated by using the Kaplan-Meier method. Cox regression analysis was performed to determine the independent contribution of each prognostic factor. RESULTS: After 37 months of median follow-up (range, 12-106), overall survival (OS) was 71 % [95 % confidence interval (CI), 54-88], disease-free survival (DFS) 61 % [95 % CI, 44-78] and loco-regional control (LRC) 76 % [95 % CI, 62-90]. In univariate analyses the [(18)F]FDG-PET/CT parameters unfavorably influencing OS, DFS and LRC were pre-treatment TGV-cutoff ≥562 (37 vs. 76 %, p = 0.01; 33 vs. 70 %, p = 0.002; and 55 vs. 83 %, p = 0.005, respectively), mean pre-treatment tumor SUV cutoff ≥5 (57 vs. 86 %, p = 0.03; 36 vs. 88 %, p = 0.004; 65 vs. 88 %, p = 0.04, respectively) and a partial tumor metabolic response after treatment (9 vs. 29 %, p = 0.0008; 0 vs. 83 %, p < 0.0001; 22 vs. 96 %, p < 0.0001, respectively). After multivariate analyses a partial tumor metabolic response after treatment remained as an independent prognostic factor unfavorably influencing DFS and LRC (RR 1:7.7, p < 0.0001, and RR 1:22.6, p = 0.0003, respectively) while the pre-treatment TGV-cutoff ≥562 negatively influenced OS and DFS (RR 1:2, p = 0.03, and RR 1:2.75, p = 0.05). CONCLUSIONS: Parameters capturing the pre-treatment glycolytic volume and metabolic activity of [(18)F]FDG-positive disease provide important prognostic information in patients with CC treated with CRT. The post-therapy [(18)F]FDG-PET/CT uptake (partial tumor metabolic response) is predictive of disease outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractObjective:The present study is aimed at contributing to identify the most appropriate OSEM parameters to generate myocardial perfusion imaging reconstructions with the best diagnostic quality, correlating them with patients' body mass index.Materials and Methods:The present study included 28 adult patients submitted to myocardial perfusion imaging in a public hospital. The OSEM method was utilized in the images reconstruction with six different combinations of iterations and subsets numbers. The images were analyzed by nuclear cardiology specialists taking their diagnostic value into consideration and indicating the most appropriate images in terms of diagnostic quality.Results:An overall scoring analysis demonstrated that the combination of four iterations and four subsets has generated the most appropriate images in terms of diagnostic quality for all the classes of body mass index; however, the role played by the combination of six iterations and four subsets is highlighted in relation to the higher body mass index classes.Conclusion:The use of optimized parameters seems to play a relevant role in the generation of images with better diagnostic quality, ensuring the diagnosis and consequential appropriate and effective treatment for the patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nombreux sont les groupes de recherche qui se sont intéressés, ces dernières années, à la manière de monitorer l'entraînement des sportifs de haut niveau afin d'optimaliser le rendement de ce dernier tout en préservant la santé des athlètes. Un des problèmes cardinaux d'un entraînement sportif mal conduit est le syndrome du surentraînement. La définition du syndrome susmentionné proposée par Kreider et al. est celle qui est actuellement acceptée par le « European College of Sport Science » ainsi que par le « American College of Sports Medicine», à savoir : « An accumulation of training and/or non-training stress resulting in long-term decrement in performance capacity with or without related physiological and psychological signs and symptoms of maladaptation in which restoration of performance capacity may take several weeks or months. » « Une accumulation de stress lié, ou non, à l'entraînement, résultant en une diminution à long terme de la capacité de performance. Cette dernière est associée ou non avec des signes et des symptômes physiologiques et psychologiques d'inadaptation de l'athlète à l'entraînement. La restauration de ladite capacité de performance peut prendre plusieurs semaines ou mois. » Les recommandations actuelles, concernant le monitoring de l'entraînement et la détection précoce du syndrome du surentrainement, préconisent, entre autre, un suivi psychologique à l'aide de questionnaires (tel que le Profile of Mood State (POMS)), un suivi de la charge d'entraînement perçue par l'athlète (p.ex. avec la session rating of perceived exertion (RPE) method selon C. Foster), un suivi des performances des athlètes et des charges d'entraînement effectuées ainsi qu'un suivi des problèmes de santé (blessures et maladies). Le suivi de paramètres sanguins et hormonaux n'est pas recommandé d'une part pour des questions de coût et de faisabilité, d'autre part car la littérature scientifique n'a, jusqu'ici, pas été en mesure de dégager des évidences à ce sujet. A ce jour, peu d'études ont suivi ces paramètres de manière rigoureuse, sur une longue période et chez un nombre d'athlète important. Ceci est précisément le but de notre étude.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We sometimes vividly remember things that did not happen, a phenomenon with general relevance, not only in the courtroom. It is unclear to what extent individual differences in false memories are driven by anatomical differences in memory-relevant brain regions. Here we show in humans that microstructural properties of different white matter tracts as quantified using diffusion tensor imaging are strongly correlated with true and false memory retrieval. To investigate these hypotheses, we tested a large group of participants in a version of the Deese-Roediger-McDermott paradigm (recall and recognition) and subsequently obtained diffusion tensor images. A voxel-based whole-brain level linear regression analysis was performedto relatefractional anisotropyto indices oftrue andfalse memory recall and recognition. True memory was correlated to diffusion anisotropy in the inferior longitudinal fascicle, the major connective pathway of the medial temporal lobe, whereas a greater proneness to retrieve false items was related to the superior longitudinal fascicle connecting frontoparietal structures. Our results show that individual differences in white matter microstructure underlie true and false memory performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main purpose of this thesis is to measure and evaluate how accurately the current energy saving calculation in ABB’s new variable speed drive ACS850 works. The main topic of this thesis is energy-efficiency parameters. At the beginning of this thesis centrifugal pump, squirrel cage motor and variable speed drive, including some equations related to them, are being introduced. Also methods of throttling control and variable speed drive control of centrifugal pumps are being introduced. These subjects are introduced because the energy saving calculation in ACS850 is related to the centrifugal pumps usually driven by squirrel cage motors. The theory also includes short section about specific energy of pumping. Before measurements the current energy saving calculation of ACS850 is being introduced and analyzed. The measurements part includes introduction of measuring equipment, measurement results, summary and analysis of the measurements. At the end of this thesis a proposal for an improvement to the current energy saving calculation is being introduced and few proposals are made for new energy-efficiency parameters, which could be added to variable speed drives. At the end are also thoughts

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The possibility and the usefulness of applying plasma keyhole welding to structural steels with different compositions and material thicknesses, and in various welding positions has been examinated. Single pass butt welding with I groove in flat, horizontal vertical and vertical positions and root welding with V , Y and U grooves of thick plate material in flat position have been studied and the welds with high quality has been obtained. The technological conditions for successful welding are presented. The single and interactive effects of welding parameters on weld quality, especially on surface weld defects, geometrical form errors, internal defects and mechanical properties (strength, ductility, impact toughness, hardness and bendability) of weld joint, are presented. Welding parameter combinations providing the best quality welds are also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current technology trends in medical device industry calls for fabrication of massive arrays of microfeatures such as microchannels on to nonsilicon material substrates with high accuracy, superior precision, and high throughput. Microchannels are typical features used in medical devices for medication dosing into the human body, analyzing DNA arrays or cell cultures. In this study, the capabilities of machining systems for micro-end milling have been evaluated by conducting experiments, regression modeling, and response surface methodology. In machining experiments by using micromilling, arrays of microchannels are fabricated on aluminium and titanium plates, and the feature size and accuracy (width and depth) and surface roughness are measured. Multicriteria decision making for material and process parameters selection for desired accuracy is investigated by using particle swarm optimization (PSO) method, which is an evolutionary computation method inspired by genetic algorithms (GA). Appropriate regression models are utilized within the PSO and optimum selection of micromilling parameters; microchannel feature accuracy and surface roughness are performed. An analysis for optimal micromachining parameters in decision variable space is also conducted. This study demonstrates the advantages of evolutionary computing algorithms in micromilling decision making and process optimization investigations and can be expanded to other applications

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Joints intended for welding frequently show variations in geometry and position, for which it is unfortunately not possible to apply a single set of operating parameters to ensure constant quality. The cause of this difficulty lies in a number of factors, including inaccurate joint preparation and joint fit up, tack welds, as well as thermal distortion of the workpiece. In plasma arc keyhole welding of butt joints, deviations in the gap width may cause weld defects such as an incomplete weld bead, excessive penetration and burn through. Manual adjustment of welding parameters to compensate for variations in the gap width is very difficult, and unsatisfactory weld quality is often obtained. In this study a control system for plasma arc keyhole welding has been developed and used to study the effects of the real time control of welding parameters on gap tolerance during welding of austenitic stainless steel AISI 304L. The welding tests demonstrated the beneficial effect of real time control on weld quality. Compared with welding using constant parameters, the maximum tolerable gap width with an acceptable weld quality was 47% higher when using the real time controlled parameters for a plate thickness of 5 mm. In addition, burn through occurred with significantly larger gap widths when parameters were controlled in real time. Increased gap tolerance enables joints to be prepared and fit up less accurately, saving time and preparation costs for welding. In addition to the control system, a novel technique for back face monitoring is described in this study. The test results showed that the technique could be successfully applied for penetration monitoring when welding non magnetic materials. The results also imply that it is possible to measure the dimensions of the plasma efflux or weld root, and use this information in a feedback control system and, thus, maintain the required weld quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stingless bees produce a honey that is different from the Apis honey in terms of composition. There aren't enough data to establish quality control parameters for this product, mainly due to lack of research results. The aim of this work is to evaluate some physicochemical parameters that can be used for the characterization and for the quality control of the Meliponinae honey. Four different samples were collected in the Amazon region of Brazil in 2004 (Melipona compressipes manaoense bee and Melipona seminigra merribae bee). Honey analyses were performed as described by the official methods. The mean results were: moisture (30.13%), pH (3.65), acidity (24.57 mEq/kg), water activity (0.75), fructose (31.91%), glucose (29.30%) and sucrose (0.19%). These results reinforce the need for a specific regulation for stingless bee honey. This will only be feasible when enough data is available to establish upper and lower limits for the physicochemical parameters used for quality control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työn teoriaosassa käsitellään ruostumattomia teräksiä ja terästen metallurgiaan vaikuttavia tekijöitä yleisesti, sekä terästen hitsattavuutta. Hitsauksesta teoriassa käydään läpi laser- ja kaasukaarihitsausta ja hitsin metallurgiaan vaikuttavia tekijöitä. Kokeellisessa osassa paneudutaan kahdeksan eri ruostumattoman teräksen hitsien metallurgiaan ja metallurgiassa tapahtuviin muutoksiin hitsausparametrien mukaan. Koemateriaaleina on neljä austeniittista ruostumatonta terästä, 201, 301LN, 316L ja 254 SMO, kaksi austeniittis-ferriittistä ruostumatonta terästä, 2101 LDX ja 2205, sekä kaksi ferriittistä ruostumatonta terästä, 430 ja 1.4003. Hitsien mikrorakenteen tutkimisessa käytettiin sekä valomikroskooppia sekä joissain tapauksissa pyyhkäisyelektronimikroskooppia. Lisäksi työn kokeellisessa osassa paneuduttiin hitsien metallografisiin syövytystekniikoihin. Kokeiden perusteella voidaan sanoa, että hitsin metallurgia riippuu hitsauksen aikaisesta lämpösyklistä ja hitsausparametreilla voidaan vaikuttaa tämän lämpösyklin muotoon. Austeniittis-ferriittisillä teräksillä hitsauksen aikaisesta lämpösyklistä riippuu pitkälti hitsin austeniitti-ferriitti-suhde. Ferriittisillä teräksillä lämpösyklin muoto vaikuttaa hitsiin muodostuvan martensiitin kovuuteen ja määrään sekä rakenteen hienojakoisuuteen. Austeniittisilla teräksillä lämpösyklinmuodon vaikutus riippuu pitkälti teräksen seostusasteesta ja seosaineista. Austeniittisilla teräksillä kokeissa havaittuja muutoksia, parametrien muutosten mukaan oli muun muassa suotautumisen voimakkuuden

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some aspects of the application of electrochemical impedance spectroscopy to studies of solid electrode / solution interface, in the absence of faradaic processes, are analysed. In order to perform this analysis, gold electrodes with (111) and (210) crystallographic orientations in an aqueous solution containing 10 mmol dm-3 KF, as supporting electrolyte, and a pyridine concentration varying from 0.01 to 4.6 mmol dm-3, were used. The experimental data was analysed by using EQUIVCRT software, which utilises non-linear least squares routines, attributing to the solid electrode / solution interface behaviour described by an equivalent circuit with a resistance in series with a constant phase element. The results of this fitting procedure were analysed by the dependence on the electrode potential on two parameters: the pre-exponential factor, Y0, and the exponent n f, related with the phase angle shift. By this analysis it was possible to observe that the pyridine adsorption is strongly affected by the crystallographic orientation of the electrode surface and that the extent of deviation from ideal capacitive behaviour is mainly of interfacial origin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stability constant (log beta) and thermodynamic parameters of Cd2+ complexes with sulfonamide and cephapirin were determined by Polarographic technique at pH = 7.30 ± 0.01 and µ = 1.0 M KNO3 at 250°C. The sulfonamides were sulfadiazine, sulfisoxazole, sulfamethaxazole, sulfamethazine, sulfathiazole, sulfacetamide and sulfanilamide used as primary ligands and cephapirin as secondary ligand. Cd2+ formed 1:1:1, 1:2:1 and 1:1:2 complexes. The nature of electrode processes were reversible and diffusion controlled. The stability constants and thermodynamic parameters (deltaG, deltaH and deltaS) were determined. The formation of the metal complexes has been found to be spontaneous, exothermic in nature, and entropically unfavourable at higher temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A quantitative analysis is made on the correlation ship of thermodynamic property, i.e., standard enthalpy of formation (ΔH fº) with Kier's molecular connectivity index(¹Xv),vander waal's volume (Vw) electrotopological state index (E) and refractotopological state index (R) in gaseous state of alkanes. The regression analysis reveals a significant linear correlation of standard enthalpy of formation (ΔH fº) with ¹Xv, Vw, E and R. The equations obtained by regression analysis may be used to estimate standard enthalpy of formation (ΔH fº) of alkanes in gaseous state.