896 resultados para Machine diagnostics
Resumo:
Two years ago, CE certified interferon-gamma release assays (IGRA) were launched on the German market (QuantiFERON-TB Gold In-Tube and T-SPOT-TB). Since this time, a multitude of studies have analysed these assays. Guidelines have been elaborated by national expert committees of England, the USA and Switzerland. However, standards of tuberculosis diagnostics and management may vary from country to country. This statement provides practice relevant recommendations for indications, pre-analytics and the interpretation of IGRA test results under different clinical conditions. The IGRA are integrated into existing guidelines for the management of tuberculosis.
Resumo:
BACKGROUND: Digital imaging methods are a centrepiece for diagnosis and management of macular disease. A recently developed imaging device is composed of simultaneous confocal scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT). By means of clinical samples the benefit of this technique concerning diagnostic and therapeutic follow-up will be assessed. METHODS: The combined OCT-SLO-System (Ophthalmic Technologies Inc., Toronto, Canada) allows for confocal en-face fundus imaging and high resolution OCT scanning at the same time. OCT images are obtained from transversal line scans. One light source and the identical scanning rate yield a pixel-to-pixel correspondence of images. Three-dimensional thickness maps are derived from C-scan stacking. RESULTS: We followed-up patients with cystoid macular edema, pigment epithelium detachment, macular hole, venous branch occlusion, and vitreoretinal tractions during their course of therapy. The new imaging method illustrates the reduction of cystoid volume, e.g. after intravitreal injections of either angiostatic drugs or steroids. C-scans are used for appreciation of lesion diameters, visualisation of pathologies involving the vitreoretinal interface, and quantification of retinal thickness change. CONCLUSION: The combined OCT-SLO system creates both topographic and tomographic images of the retina. New therapeutic options can be followed-up closely by observing changes in lesion thickness and cyst volumes. For clinical use further studies are needed.
Resumo:
Complete correction of Tetralogy of Fallot, the most common cyanotic congenital heart defect, has now become routine. However, late residual lesions, primarily chronic pulmonary valve insufficiency, may have a negative impact on right-ventricular function, leading to the need for reoperation to insert a competent valve at the right-ventricular outflow. The diagnostic modalities pertaining to the failing right ventricle, the timing for eventual reintervention and the various surgical reconstruction possibilities of the right-ventricular outflow tract are still controversial and evolving, and are reviewed with a brief overview on current trends and future outlooks.
Resumo:
Objective. The purpose of this study was to determine the dose profile of the Cranex Tome radiography unit and compare it with that of the Scanora machine.Study design. The radiation dose delivered by the Cranex Tome radiography unit during the cross-sectional mode was determined. Single tooth gaps in regions 3 (16) and 30 (46) were simulated. Dosimetry was carried out with 2 phantoms, a head and neck phantom and a full-body phantom loaded with 142 thermoluminescent dosimeters (TLD) and 280 TLD, respectively; all locations corresponded to radiosensitive organs or tissues. The recorded local mean organ doses were compared with those measured in another study evaluating the Scanora machine.Results. Generally, dose values from the Cranex Tome radiography unit reached only 50% to 60% of the values measured for the Scanora machine. The effective dose was calculated as 0.061 mSv and 0.04 mSv for tooth regions 3 (16) and 30 (46), respectively. Corresponding values for the Scanora machine were 0.117 mSv and 0.084 mSv.Conclusion. Cross-sectional imaging in the molar region of the upper and the lower jaw can be performed with the Cranex Tome unit, which delivers only approximately half of the dose that the Scanora machine delivers.
Resumo:
OBJECTIVE: The purpose of this study was to adapt and improve a minimally invasive two-step postmortem angiographic technique for use on human cadavers. Detailed mapping of the entire vascular system is almost impossible with conventional autopsy tools. The technique described should be valuable in the diagnosis of vascular abnormalities. MATERIALS AND METHODS: Postmortem perfusion with an oily liquid is established with a circulation machine. An oily contrast agent is introduced as a bolus injection, and radiographic imaging is performed. In this pilot study, the upper or lower extremities of four human cadavers were perfused. In two cases, the vascular system of a lower extremity was visualized with anterograde perfusion of the arteries. In the other two cases, in which the suspected cause of death was drug intoxication, the veins of an upper extremity were visualized with retrograde perfusion of the venous system. RESULTS: In each case, the vascular system was visualized up to the level of the small supplying and draining vessels. In three of the four cases, vascular abnormalities were found. In one instance, a venous injection mark engendered by the self-administration of drugs was rendered visible by exudation of the contrast agent. In the other two cases, occlusion of the arteries and veins was apparent. CONCLUSION: The method described is readily applicable to human cadavers. After establishment of postmortem perfusion with paraffin oil and injection of the oily contrast agent, the vascular system can be investigated in detail and vascular abnormalities rendered visible.
Resumo:
Eosinophils and gastrointestinal tract interact in an intimate and enigmatic relationship. Under inflammatory conditions, eosinophil infiltration in the gastrointestinal tract is a common feature of numerous eosinophilic gastrointestinal disorders (EGIDs). EGIDs are disorders, for which the diagnosis is relatively difficult. Nevertheless, some common laboratory techniques are currently used for their diagnosis and disease monitoring. Besides eosinophils, mast cells and T cells have also been suggested to play a role in the pathogenesis of these disorders. Here, we review the pathogenesis and common laboratory approaches applied for their diagnosis, in particular eosinophil and mast cell markers.
Resumo:
With energy demands and costs growing every day, the need for improving energy efficiency in electrical devices has become very important. Research into various methods of improving efficiency for all electrical components will be a key to meet future energy needs. This report documents the design, construction, and testing of a research quality electric machine dynamometer and test bed. This test cell system can be used for research in several areas including: electric drives systems, electric vehicle propulsion systems, power electronic converters, load/source element in an AC Microgrid, as well as many others. The test cell design criteria, and decisions, will be discussed in reference to user functionality and flexibility. The individual power components will be discussed in detail to how they relate to the project, highlighting any feature used in operation of the test cell. A project timeline will be discussed, clearly stating the work done by the different individuals involved in the project. In addition, the system will be parameterized and benchmark data will be used to provide the functional operation of the system. With energy demands and costs growing every day, the need for improving energy efficiency in electrical devices has become very important. Research into various methods of improving efficiency for all electrical components will be a key to meet future energy needs. This report documents the design, construction, and testing of a research quality electric machine dynamometer and test bed. This test cell system can be used for research in several areas including: electric drives systems, electric vehicle propulsion systems, power electronic converters, load/source element in an AC Microgrid, as well as many others. The test cell design criteria, and decisions, will be discussed in reference to user functionality and flexibility. The individual power components will be discussed in detail to how they relate to the project, highlighting any feature used in operation of the test cell. A project timeline will be discussed, clearly stating the work done by the different individuals involved in the project. In addition, the system will be parameterized and benchmark data will be used to provide the functional operation of the system.
Resumo:
Autoantibodies play a key role in diagnostic laboratories as markers of autoimmune diseases. In addition to their role as markers they mediate diverse effects in vivo. Autoantibodies with protective effect have been described. Natural protective IgM autoantibodies against tumour-antigens of malignant cells or their precursors may contribute to increased survival rates of carcinoma patients. In a mouse model of systemic lupus erythematosus it has been shown that anti-dsDNA IgM autoantibodies protect from glomerular damage. In contrast, a direct pathogenic role of autoantibodies has been well established e.g. in myasthenia gravis or in Goodpasture syndrome. Similarly autoantibodies against SSA Ro52 are detrimental in neonatal lupus erythematosus with congenital heart block. Moreover, putatively protective autoantibodies may become pathogenic during the course of the disease such as the onconeuronal autoantibodies whose pathogenicity depends on their compartmentalisation. In patients with paraneoplastic syndromes tumour cells express proteins that are also naturally present in the brain. Anti-tumour autoantibodies which temporarily suppress tumour growth can provoke an autoimmune attack on neurons once having crossed the blood-brain barrier and cause specific neurological symptoms. Only a restricted number of autoantibodies are useful follow-up markers for the effectiveness of treatment in autoimmune diseases. Certain autoantibodies hold prognostic value and appear years or even decades before the diagnosis of disease such as the antimitochondrial antibodies in primary biliary cirrhosis or anti-citrullinated protein (CCP)-antibodies in rheumatoid arthritis. It is crucial to know whether the autoantibodies in question recognise linear or conformational epitopes in order to choose the appropriate detection methods. Indirect immunofluorescence microscopy remains a very useful tool for confirmation of results of commercially available immunoassays and for detection of special and rare autoantibodies that otherwise often remain undetected. Standardisation of autoimmune diagnostics is still underway and requires joint efforts by laboratories, clinicians and industry.
Resumo:
The problem in this investigation was to determine if mineral specimens mounted in bakelite, or lucite, could be polished for microscopic examination by the use of an optical polishing machine, and if this method would cut down the length of time required to polish specimens by the methods now in use.
Resumo:
Abstract Radiation metabolomics employing mass spectral technologies represents a plausible means of high-throughput minimally invasive radiation biodosimetry. A simplified metabolomics protocol is described that employs ubiquitous gas chromatography-mass spectrometry and open source software including random forests machine learning algorithm to uncover latent biomarkers of 3 Gy gamma radiation in rats. Urine was collected from six male Wistar rats and six sham-irradiated controls for 7 days, 4 prior to irradiation and 3 after irradiation. Water and food consumption, urine volume, body weight, and sodium, potassium, calcium, chloride, phosphate and urea excretion showed major effects from exposure to gamma radiation. The metabolomics protocol uncovered several urinary metabolites that were significantly up-regulated (glyoxylate, threonate, thymine, uracil, p-cresol) and down-regulated (citrate, 2-oxoglutarate, adipate, pimelate, suberate, azelaate) as a result of radiation exposure. Thymine and uracil were shown to derive largely from thymidine and 2'-deoxyuridine, which are known radiation biomarkers in the mouse. The radiation metabolomic phenotype in rats appeared to derive from oxidative stress and effects on kidney function. Gas chromatography-mass spectrometry is a promising platform on which to develop the field of radiation metabolomics further and to assist in the design of instrumentation for use in detecting biological consequences of environmental radiation release.
Resumo:
PURPOSE: We assessed the efficacy of extracorporeal shock wave lithotripsy (ESWL, Dornier Medical Systems, Inc., Marietta, Georgia) for distal ureteral calculi with the HM3 (Dornier Medical Systems, Inc.) lithotriptor. MATERIALS AND METHODS: A total of 585 consecutive patients with distal ureteral calculi were treated with ESWL using an unmodified HM3 lithotriptor. Of these patients 67 referred for treatment only for whom no followup was available were excluded from further analysis. The remaining 518 cases were followed until they were radiologically documented to be stone-free or considered treatment failures. Before ESWL additional procedures were performed in 144 patients, including stone push back, ureteral catheter or Double-J (Medical Engineering Corp., New York, New York) stent placement, percutaneous nephrostomy, ureteral endoscopic maneuvers or stone basket manipulation. A total of 374 patients needed no preliminary treatment before ESWL. RESULTS: Of the 518 patients 469 (91%) were successfully treated with 1 ESWL session, while 49 (9%) needed 2 or 3. Manipulation after ESWL was performed in 22 cases, including stent placement, percutaneous nephrostomy, ureteral endoscopic stone removal and a stone basket procedure. On day 1 after ESWL 327 patients (63%) were stone-free, 158 (30%) had less than 5 mm. fragments and 33 (7%) had more than 5 mm. fragments. At 3 months the stone-free rate increased to 97%. CONCLUSIONS: These data show that ESWL for distal ureteral calculi with the powerful unmodified HM3 lithotriptor has a high success rate with a low rate of minimally traumatic manipulations before and after intervention. Results in terms of the re-treatment and stone-free rates are superior to those of any other second or third generation lithotriptor and comparable to the results of the best ureteroscopic series.