934 resultados para Lead recycling
Resumo:
The processing of ferroelectric BaBi4Ti4O15 (BBT) ceramics from powders prepared by conventional solid state reaction (SSR) and mechanochemical activation (MA) has been investigated. It was shown that MA synthesis reduces the synthesis temperature of BBT powders, leading to smaller particles with reduced anisotropy and consequently to smaller grain size of ceramics. Dielectric properties were investigated in a wide range of temperatures (20-800 degrees C) and frequencies (1.21 kHz to 1 MHz). The relative dielectric permittivity at Curie temperature was higher for solid state obtained ceramics than for the mechanically treated ones. The conductivity of sintered samples was studied, suggesting decreasing of conductivity of BBT-MA in comparison with BBT-SS ceramics. The influence of the grain and the grain boundaries contribution to the dielectric behavior in both ceramics was analyzed through impedance spectroscopy. A well-defined ferroelectric hysteresis loop was obtained for both samples. (C) 2014 Elsevier Ltd and Techna Group S.r.l. All rights reserved.
Resumo:
The expansion and maintenance of electricity distribution networks generates large amounts of waste, much of it in the form of discarded insulators that are not reused or recycled. This paper describes the results of tests on used and new ceramic and polymeric insulators to verify if their exposure to weathering justifies their replacement. In new and used ceramic insulators, properties such as contact angle, relative density, porosimetry, dilatometry and X-ray diffraction patterns showed no differences or the differences that were found could not be related to their use. The discarded ceramic material showed high thermal stability, an interesting characteristic for application as chamotte. It can also be reused to replace gravel used in substations. In polymeric insulators, thermogravimetry, differential scanning calorimetry and relative density test results suggest degradation of used material compared to new. This would justify their replacement and discard as waste, but they show little recycling potential.
Resumo:
When exhausted, the batteries are classified as hazardous waste because it has potentially toxic heavy metals and bio-accumulators, such as mercury, cadmium and lead in their internal composition functional. Due to the high level of danger, such waste should be properly designed to not allow theses chemical components to cause significant impacts on the environment. Thus, the recycling of waste in question is the best destination. In this context, was wanted to know, through a questionnaire in interview format, how the graduates of the Universidade Estadual Paulista Julio de Mesquita Filho of Rio Claro / SP are involved with this environmental issue. Since then, has been developed and implemented an environmental management for internal batteries
Resumo:
The constant search for improvement and survival of the companies makes essential the utilization of cost reduction strategies and resources optimization. This study had as its objective the utilization of Lean Manufacturing tools for the repair process lead time reduction, in a car audio manufacturer. Performing an action research, the major problems were studied, such as the potential causes and the possible improvement activities, using the DMAIC methodology. An action plan was developed for all involved processes and, as a result, the objective was reached by making a direct impact on the customers’ satisfaction and adding a competitive differential for the company
Resumo:
Facing the competitive current market, increases the growing managerial commitment to minimize the frequent occurrence of service failures that characterized the past. Given the fact that the supply of a product in the correct location and on time, undamaged and correctly billed market requirement becomes framed the present work. Based on a case study, supported in parallel bibliographical references in the literature in a company of sugar and alcohol sector, the survey aims to measure and evaluate the real-time delivery from suppliers in order to ensure the best level of service to the company in question by suppliers, by reducing idle time of delivery, since the control system does not supply the pre-established and / or observed above, thus obtaining a better management and supply of replacement material. To assist the work, developed a project in the company in question in order to analyze and identify applications of concepts of lead time along the supply chain through an exploratory study in order to provide a beneficial outcome to the company through monitoring and performance of its suppliers, which will enable an aid to future decision-making
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Throughout the world, biomonitoring has become the standard for assessing exposure of individuals to toxic elements as well as for responding to serious environmental public health problems. However, extensive biomonitoring surveys require rapid and simple analytical methods. Thus, a simple and high-throughput method is proposed for the determination of arsenic (As), cadmium (Cd), copper (Cu), manganese (Mn), nickel (Ni), lead (Pb), and selenium (Se) in blood samples by using inductively coupled plasma–mass spectrometry (ICPMS). Prior to analysis, 200 ml of blood samples was mixed with 500 ml of 10% v/v tetramethylammonium hydroxide (TMAH) solution, incubated for 10 min, and subsequently diluted to 10 ml with a solution containing 0.05% w/v ethylenediamine tetraacetic acid (EDTA) + 0.005% v/v Triton X-100. After that, samples were directly analyzed by ICP-MS (ELAN DRC II). Rhodium was selected as an internal standard with matrix-matching calibration. Method detection limits were 0.08, 0.04, 0.5, 0.09, 0.12, 0.04, and 0.1 mg//L for As, Cd, Cu, Mn, Ni, Pb, and Se, respectively. Validation data are provided based on the analysis of blood samples from the trace elements inter-\comparison program operated by the Institut National de Santé Publique du Quebec, Canada. Additional validation was provided by the analysis of human blood samples by the proposed method and by using electrothermal atomic absorption spectrometry (ETAAS). The method was subsequently applied for the estimation of background metal blood values in the Brazilian population. In general, the mean concentrations of As, Cd, Cu, Mn, Ni, Pb, and Se in blood were 1.1, 0.4, 890, 9.6, 2.1, 65.4, and 89.3 mg/L, respectively, and are in agreement with other global populations. Influences of age, gender, smoking habits, alcohol consumption, and geographical variation on the values were also considered. Smoking habits influenced the levels of Cd in blood. The levels of Cu, Mn, and Pb were significantly correlated with gender, whereas Cu and Pb were significantly correlated with age. There were also interesting differences in Mn and Se levels in the population living in the north of Brazil compared to the south.
Resumo:
Pós-graduação em Química - IQ
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The Advanced LIGO gravitational wave detectors are second-generation instruments designed and built for the two LIGO observatories in Hanford, WA and Livingston, LA, USA. The two instruments are identical in design, and are specialized versions of a Michelson interferometer with 4 km long arms. As in Initial LIGO, Fabry-Perot cavities are used in the arms to increase the interaction time with a gravitational wave, and power recycling is used to increase the effective laser power. Signal recycling has been added in Advanced LIGO to improve the frequency response. In the most sensitive frequency region around 100 Hz, the design strain sensitivity is a factor of 10 better than Initial LIGO. In addition, the low frequency end of the sensitivity band is moved from 40 Hz down to 10 Hz. All interferometer components have been replaced with improved technologies to achieve this sensitivity gain. Much better seismic isolation and test mass suspensions are responsible for the gains at lower frequencies. Higher laser power, larger test masses and improved mirror coatings lead to the improved sensitivity at mid and high frequencies. Data collecting runs with these new instruments are planned to begin in mid-2015.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This article describes a new approach of recycling the leather waste (shavings) using it as filler in natural rubber foams composites. The foams were prepared using different amounts of leather waste (0-60 parts per hundred of rubber) and submitted to morphological (SEM microscopy) and mechanical analyses (cyclic stress-strain compression). The increase of leather shavings on the composite causes an increase of viscosity in the mixture, which reflects in the foaming process. This results in smaller and fairly uniform cells. Furthermore, expanded rubber has the biggest cell size, with more than 70% of cell with 1000 mu m, while the composite with the higher concentration of leather has around 80% of total number of cells with 100-400 mu m. The mechanical parameters were found to depend on the leather dust concentration. Moreover, the stiffness rises with the increase of leather shavings; consequently, the compression force for expanded rubber was 0.126 MPa as well as the composite with higher concentration of leather was 7.55 MPa. (c) 2014 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2015, 132, 41636.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Processing and structural properties of random oriented lead lanthanum zirconate titanate thin films
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)