947 resultados para Laser tuning
Resumo:
Objectives: A study was made to determine the temperature increment at the dental root surface following Er,Cr:YSGG laser irradiation of the root canal. Design. Human canines and incisors previously instrumented to K file number ISO 30 were used. Irradiation was carried out with glass fiber endodontic tips measuring 200 μm in diameter and especially designed for insertion in the root canal. The teeth were irradiated at 1 and 2 W for 30 seconds, without water spraying or air, and applying a continuous circular movement (approximately 2 mm/sec.) in the apico-coronal direction. Results: At the 1 W power setting, the mean temperature increment was 3.84ºC versus 5.01ºC at 2 W. In all cases the difference in mean value obtained after irradiation versus the mean baseline temperature proved statistically significant (p< 0.05). Conclusions: Application of the Er,Cr:YSGG laser gives rise to a statistically significant temperature increment at the external root surface, though this increment is probably clinically irrelevant, since it would appear to damage the tissues (periodontal ligament and alveolar bone) in proximity to the treated tooth
Resumo:
Tässä työssä raportoidaan hybridihitsauksesta otettujen suurnopeuskuvasarjojen automaattisen analyysijärjestelmän kehittäminen.Järjestelmän tarkoitus oli tuottaa tietoa, joka avustaisi analysoijaa arvioimaan kuvatun hitsausprosessin laatua. Tutkimus keskittyi valokaaren taajuuden säännöllisyyden ja lisäainepisaroiden lentosuuntien mittaamiseen. Valokaaria havaittiin kuvasarjoista sumean c-means-klusterointimenetelmän avullaja perättäisten valokaarien välistä aikaväliä käytettiin valokaaren taajuuden säännöllisyyden mittarina. Pisaroita paikannettiin menetelmällä, jossa yhdistyi pääkomponenttianalyysi ja tukivektoriluokitin. Kalman-suodinta käytettiin tuottamaan arvioita pisaroiden lentosuunnista ja nopeuksista. Lentosuunnanmääritysmenetelmä luokitteli pisarat niiden arvioitujen lentosuuntien perusteella. Järjestelmän kehittämiseen käytettävissä olleet kuvasarjat poikkesivat merkittävästi toisistaan kuvanlaadun ja pisaroiden ulkomuodon osalta, johtuen eroista kuvaus- ja hitsausprosesseissa. Analyysijärjestelmä kehitettiin toimimaan pienellä osajoukolla kuvasarjoja, joissa oli tietynlainen kuvaus- ja hitsausprosessi ja joiden kuvanlaatu ja pisaroiden ulkomuoto olivat samankaltaisia, mutta järjestelmää testattiin myös osajoukon ulkopuolisilla kuvasarjoilla. Testitulokset osoittivat, että lentosuunnanmääritystarkkuus oli kohtuullisen suuri osajoukonsisällä ja pieni muissa kuvasarjoissa. Valokaaren taajuuden säännöllisyyden määritys oli tarkka useammassa kuvasarjassa.
Resumo:
Fiber laser for materials processing have undergone a rapid development in the pastseveral years. As fiber laser provides a combination of high beam quality and awavelength that is easily absorbed by metal surfaces, the named future laser isexpected to challenge the CO2 and Nd:YAG lasers in the area of metal cutting. This thesis studied the performance of fiber laser cutting mild steel. In the literature review part, it introduced the laser cutting principle and the principle of fiber laser including the newest development of fiber laser cuttingtechnology. Because the fiber laser cutting mild steel is a very young technology, a preliminary test was made in order to investigate effect of the cutting parameters on cut quality. Then the formal fiber laser cutting experiment was madeby using 3 mm thickness S355 steel with oxygen as assistant gas. The experimentwas focused on the cut quality with maximum cutting speed and minimum oxygen gas pressure. And the cut quality is mainly decided by the kerf width, perpendicularity tolerance, surface roughness and striation patterns. After analysis the cutting result, several conclusions were made. Although the best result got in the experiment is not perfect as predicted, the whole result of the test can be accepted. Compared with CO2 laser, a higher cutting speed was achieved by fiber laser with very low oxygen gas pressure. A further improvement about the cutting quality might be possible by proper selection of process parameters. And in order to investigate the cutting performance more clearly, a future study about cutting different thickness mild steel and different shape was recommended.
Resumo:
This paper describes a mesurement system designed to register the displacement of the legs using a two-dimensional laser range sensor with a scanning plane parallel to the ground and extract gait parameters. In the proposed methodology, the position of the legs is estimated by fitting two circles with the laser points that define their contour and the gait parameters are extracted applying a step-line model to the estimated displacement of the legs to reduce uncertainty in the determination of the stand and swing phase of the gait. Results obtained in a range up to 8 m shows that the systematic error in the location of one static leg is lower than 10 mm with and standard deviation lower than 8 mm; this deviation increases to 11 mm in the case of a moving leg. The proposed measurement system has been applied to estimate the gait parameters of six volunteers in a preliminary walking experiment.
Resumo:
The optimization of most pesticide and fertilizer applications is based on overall grove conditions. In this work we measurements. Recently, Wei [9, 10] used a terrestrial propose a measurement system based on a ground laser scanner to LIDAR to measure tree height, width and volume developing estimate the volume of the trees and then extrapolate their foliage a set of experiments to evaluate the repeatability and surface in real-time. Tests with pear trees demonstrated that the accuracy of the measurements, obtaining a coefficient of relation between the volume and the foliage can be interpreted as variation of 5.4% and a relative error of 4.4% in the linear with a coefficient of correlation (R) of 0.81 and the foliar estimation of the volume but without real-time capabilities. surface can be estimated with an average error less than 5 %.
Resumo:
The geometric characterisation of tree orchards is a high-precision activity comprising the accurate measurement and knowledge of the geometry and structure of the trees. Different types of sensors can be used to perform this characterisation. In this work a terrestrial LIDAR sensor (SICK LMS200) whose emission source was a 905-nm pulsed laser diode was used. Given the known dimensions of the laser beam cross-section (with diameters ranging from 12 mm at the point of emission to 47.2 mm at a distance of 8 m), and the known dimensions of the elements that make up the crops under study (flowers, leaves, fruits, branches, trunks), it was anticipated that, for much of the time, the laser beam would only partially hit a foreground target/object, with the consequent problem of mixed pixels or edge effects. Understanding what happens in such situations was the principal objective of this work. With this in mind, a series of tests were set up to determine the geometry of the emitted beam and to determine the response of the sensor to different beam blockage scenarios. The main conclusions that were drawn from the results obtained were: (i) in a partial beam blockage scenario, the distance value given by the sensor depends more on the blocked radiant power than on the blocked surface area; (ii) there is an area that influences the measurements obtained that is dependent on the percentage of blockage and which ranges from 1.5 to 2.5 m with respect to the foreground target/object. If the laser beam impacts on a second target/object located within this range, this will affect the measurement given by the sensor. To interpret the information obtained from the point clouds provided by the LIDAR sensors, such as the volume occupied and the enclosing area, it is necessary to know the resolution and the process for obtaining this mesh of points and also to be aware of the problem associated with mixed pixels.
Resumo:
Background: Proliferative retinopathy is an important cause of vision loss in diabetic patients. Incomplete panretinal photocoagulation (PRP) can lead to recurrent proliferation of new vessels. Patients and Methods: We retrospectively analysed the outcome of patients with high risk proliferative diabetic retinopathy (PDR) previously treated with slit lamp PRP who underwent indirect fill in argon laser treatment with scleral indentation under anesthesia for persistent neovascular proliferation. Results: Seventeen eyes of ten patients were included. The mean age at diabetes onset was 17.3 years SD 16.2 (range 2-44). All patients reported long standing poor glycemic control (mean HbA1c: 8.5 % SD 1.3 range 5.9-10.2). The area of retinal ischemia decreased significantly from 15 ± 7.5 disk areas (DA) before fill-in laser to 3.2 ± 4.2 DA after fill-in laser (p = 0.001). The new vessels also regressed significantly after laser treatment 8.6 ± 6.1 DA before treatment versus 6.5 ± 6.4 DA after laser treatment, (p = 0.044). Quiescent PDR was reached in 10 eyes (58.8 %) at the last visit. Conclusions: Fill-in indirect argon laser under general anesthesia should be considered to achieve further new vessels regression in high risk PDR patients. Scleral indentation and absence of pain may allow for more extensive laser application.
Resumo:
Raaka-aineen hiukkaskoko on lääkekehityksessä keskeinen materiaaliparametri. Lääkeaineen partikkelikoko vaikuttaa moneen lääketuotteen tärkeään ominaisuuteen, esimerkiksi lääkkeen biologiseen hyväksikäytettävyyteen. Tässä diplomityössä keskityttiin jauhemaisten lääkeaineiden hiukkaskoon määrittämiseen laserdiffraktiomenetelmällä. Menetelmä perustuu siihen, että partikkeleista sironneen valon intensiteetin sirontakulmajakauma on riippuvainen partikkelien kokojakaumasta. Työn kirjallisuusosassa esiteltiin laserdiffraktiomenetelmän teoriaa. PIDS (Polarization Intensity Differential Scattering) tekniikka, jota voidaan käyttää laserdiffraktion yhteydessä, on myös kuvattu kirjallisuusosassa. Muihin menetelmiin perustuvista analyysimenetelmistä tutustuttiin mikroskopiaan sekä aerodynaamisen lentoajan määrittämiseen perustuvaan menetelmään. Kirjallisuusosassa esiteltiin myös partikkelikoon yleisimpiä esitystapoja. Työn kokeellisen osan tarkoituksena oli kehittää ja validoida laserdiffraktioon perustuva partikkelikoon määritysmenetelmä tietylle lääkeaineelle. Menetelmäkehitys tehtiin käyttäen Beckman Coulter LS 13 320 laserdiffraktoria. Laite mahdollistaa PIDS-tekniikan käytön laserdiffraktiotekniikan ohella. Menetelmäkehitys aloitettiin arvioimalla, että kyseinen lääkeaine soveltuu parhaiten määritettäväksi nesteeseen dispergoituna. Liukoisuuden perusteella väliaineeksi valittiin tällä lääkeaineella kyllästetty vesiliuos. Dispergointiaineen sekä ultraäänihauteen käyttö havaittiin tarpeelliseksi dispergoidessa kyseistä lääkeainetta kylläiseen vesiliuokseen. Lopuksi sekoitusnopeus näytteensyöttöyksikössä säädettiin sopivaksi. Validointivaiheessa kehitetyn menetelmän todettiin soveltuvan hyvin kyseiselle lääkeaineelle ja tulosten todettiin olevan oikeellisia sekä toistettavia. Menetelmä ei myöskään ollut herkkä pienille häiriöille.
Resumo:
Diplomityö tarkastelee säikeistettyä ohjelmointia rinnakkaisohjelmoinnin ylemmällä hierarkiatasolla tarkastellen erityisesti hypersäikeistysteknologiaa. Työssä tarkastellaan hypersäikeistyksen hyviä ja huonoja puolia sekä sen vaikutuksia rinnakkaisalgoritmeihin. Työn tavoitteena oli ymmärtää Intel Pentium 4 prosessorin hypersäikeistyksen toteutus ja mahdollistaa sen hyödyntäminen, missä se tuo suorituskyvyllistä etua. Työssä kerättiin ja analysoitiin suorituskykytietoa ajamalla suuri joukko suorituskykytestejä eri olosuhteissa (muistin käsittely, kääntäjän asetukset, ympäristömuuttujat...). Työssä tarkasteltiin kahdentyyppisiä algoritmeja: matriisioperaatioita ja lajittelua. Näissä sovelluksissa on säännöllinen muistinkäyttökuvio, mikä on kaksiteräinen miekka. Se on etu aritmeettis-loogisissa prosessoinnissa, mutta toisaalta huonontaa muistin suorituskykyä. Syynä siihen on nykyaikaisten prosessorien erittäin hyvä raaka suorituskyky säännöllistä dataa käsiteltäessä, mutta muistiarkkitehtuuria rajoittaa välimuistien koko ja useat puskurit. Kun ongelman koko ylittää tietyn rajan, todellinen suorituskyky voi pudota murto-osaan huippusuorituskyvystä.
Resumo:
Työn tavoitteena oli selvittää Stora Enso Oyj:llä käytössä olevan Fenix myynnin- ja logistiikanhallintajärjestelmän logistiikkapalveluiden suorituskyky, tuottaa asiakasohjelmisto suorituskykymittauksista muodostuneen tiedon hallintaan sekä tuottaa toteuttamissuunnitelma suorituskyvyn parantamiseksi. Suorituskyky mitattiin käyttämällä TUXEDOn tarjoamia ominaisuuksia. Suorituskykymittausten tuloksien arviointia varten rakennettiin asiakasohjelmisto, jolla pystyttiin tuottamaan tarvittavat yhteenvetotiedot palveluiden kestoista ja rakenteista. Valmiita ratkaisuja ei ollut tarjolla, joten kaikki tarvittavat ohjelmistot on rakennettu osana tätä työtä. Kaikki komponenttiliittymät toteutettiin siten, että myös muitakin kuin logistiikkaan liittyviä palveluita voidaan tarvittaessa mitata. Mittausten tuloksena saatuja keskimääräisiä suoritusaikoja käytettiin hyväksi toteuttamissuunnitelmaa tehdessä. Toteutussuunnitelma sisältää useiden logistiikka-alueiden kehittämisideoita, joilla Fenixin logistiikkapalveluiden suorituskykyä voidaan tehostaa., ja nykyinen järjestelmän toimintanopeus pystytään säilyttämään tulevaisuudessa. Toteuttamissuunnitelmassa esitettyjä toimenpiteitä tullaan toteuttamaan TietoEnator Oyj:ssä vuoden 2003 aikana.
Resumo:
Quartz tuning forks are extremely good resonators and their use is growing in scanning probe microscopy. Nevertheless, only a few studies on soft biological samples have been reported using these probes. In this work, we present the methodology to develop and use these nanosensors to properly work with biological samples. The working principles, fabrication and experimental setup are presented. The results in the nanocharacterization of different samples in different ambients are presented by using different working modes: amplitude modulation with and without the use of a Phase-Locked Loop (PLL) and frequency modulation. Pseudomonas aeruginosa bacteria are imaged in nitrogen using amplitude modulation. Microcontact printed antibodies are imaged in buffer using amplitude modulation with a PLL. Finally, metastatic cells are imaged in air using frequency modulation.