965 resultados para Inspeção sanitária
Resumo:
A technological alternative for the correct disposal of tires is the use in the construction of embankment with soil and shredded tires. The use of waste tires in tropical soils requires prior knowledge of the properties and limitations of these materials. In this work, the results of an experimental program was devised to characterize the behavior of mixtures of waste tires and a lateritic soil. The residue used in this study is classified as tire buffings with an average size of 1.4 mm. The laboratory program included testing of particle size analysis, Atterberg limits, compaction, direct shear tests, permeability and confined compression tests with pure soil, pure tire and the mixtures. Proportions of 0% (pure soil), 10%, 20%, 40%, 50 % and 100% (pure tire) by weight were used. For the confining stress levels used in the study, the presence of tire residue provided a considerable increase in shear strength of the mixture. The maximum shear strength was obtained for a residue content of 40% by weight. Permeability tests on samples of waste under a confining stress of 100 kPa showed that the permeability increases significantly with increasing residue content until a residue content of 20%. The increase in permeability after that value showed to be negligible. Confined compression tests showed that the soil mixed with tire residue becomes more compressible than the pure soil. The secant constrained modulus (Msec) for the same vertical stress decreases with increasing percentage of residue.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Resumo:
The state of Rio Grande do Norte, possessor of an extremely irregular regime of rains, has the necessity of enlarge and specify the researches about its own hydro-climatic conditions, to achieve trustworthy results that are able to minimize the adversities imposed by these conditions and make possible the implementation of a better planning in the economic activities and of subsistence that somehow utilize of the multiple uses of hydro resources of the State. This way, the daily values observed from the pluviometric series of 166 posts, with 45 years uninterrupted of historic data, were adjusted to the incomplete gamma function to the determination of the probability of rain in the 36 period of ten days in which the year was divided. To the attainment of the α and β parameters of this function it was applied the method of the maximum verisimilitude allowing, in the end, to analyze the temporal and spatial distribution of the rain in the level of 75% of probability. The values of potential evapo-transpiration were calculated by the Linacre method that, through the SURFER software, were confronted with the dependant rain, obtaining, in this way, the spatialization of the potential hydro availability, which the values can be known to any period of ten days of the year, city and/or region of the state of Rio Grande do Norte. With the identification of the main meteorological systems that act in the State, we sought to better comprehend how this systems interfere, in the irregular regime of rain, in the situations of several clime in the major part of Rio Grande do Norte and in the hydro regional balance. And, finally, with these data in hand and with the generated maps, we verified that space-temporal distribution of the rain and of the potential hydro availability were heterogeneous in the whole State, mainly in the West and Central regions, inserted in potiguar s semi-arid, which, after the period of the rains station, suffers with dry season and length drought during the rest of the year
Resumo:
Dengue fever is an infectious disease that causes thousands of deaths each year in Brazil and other tropical countries. This work demonstrates that the irregularity in the supply of water by public water supply systems is a major factor that contributes to the proliferation of breeding sites of the mosquito that transmits dengue, due to the impossibility of removing water storage tanks. 31 points in the water supply network in thirteen districts of Natal, Brazil, were monitored by the installation of pressure gauges type Datalogger. The data about pressure showed deficiency in water supplies in many neighborhoods, forcing residents to accumulate water in tanks at ground level. In addition, It was observed that in neighborhoods with regular water supply, Infestation Index per type of container (ITR) of type A2 (Deposit ground level) was 0.00% and where there were failures in the supply of water , the ITR was high (above 50%). We believe that policies to combat dengue in Brazil should be reassessed so that more resources can be directed to the improvement of water supply systems and supply companies should be blamed for the problem too
Resumo:
In semiarid region of northeast Brazil, the majority of reservoirs used for public supply has suffered degradation of water quality affected by diffuse pollution from agricultural and livestock areas of the watershed and by hydrologic regime peculiar to the region, characterized by a rainy season with higher volumes stored in reservoirs and a dry season with a reduction in water level due to high evaporation and increase of eutrophication. The Dourado reservoir, located in Currais Novos city, semiarid region of Rio Grande do Norte state, is one example of a water supply reservoir that can have degradation of water quality and impracticability of their use, due to the high external input of nutrients from non-point sources of watershed during the rainy season and increasing of eutrophication due to decrease the stored volume during the dry period. This study aimed to investigate and quantify diffuse pollution and the hydrologic regime of semiarid region in order to establish standards regarding the water quality of Dourado reservoir. The study period was between the months of May 2011 to March 2012. The diffuse pollution was quantified in terms of watershed from the mass balance of phosphorus in the reservoir, as in relation to areas under different types of land use within the riparian zone of the reservoir from the assessment of soil chemical properties and losses of phosphorus in each area. The influence of hydrological regime on water quality of the reservoir was evaluated from the monthly monitoring of the morphometric, meteorological and limnological features throughout the study period. The results showed that the reservoir has received a high load of phosphorus coming from the drainage basin and presents itself as a system able to retain some of that load tributary, giving an upward trend of the eutrophication process. Diffuse pollution by nutrients from areas under different types of land use within the riparian zone of the reservoir was higher in areas under the influence of livestock, being this area considered a potential diffuse source of nutrients to the reservoir. Regarding the water regime during the rainy season the reservoir was characterized by high concentrations of nutrients and small algal biomass, while in the dry season the reduction of volume and increase of the water retention time of the reservoir, contributing to the excessive growth algal biomass, favoring an increase in eutrophication and deterioration of water quality. In synthesis the water quality of Dourado reservoir is directed by diffuse pollution coming from the drainage basin and the hydrological regime of the peculiar semiarid region, where the rainy season is characterized by high input of allochthonous compounds from the tributaries and erosion of the soil in the reservoir riparian zone, and the dry season characterized by reducing the storage volume due to high evaporation, high residence time of water and consequent degradation of water quality due to the increase of eutrophication process
Resumo:
The semiarid potiguar presents a quite discrepant. It is a region with one of the highest rates of artificial lake the world, but the policy of building dams to mitigate the problem of water scarcity does not solve, given that they have not demonstrated the ability to ensure supply human priority during periods of great drought and fail to solve the widespread demand existent in the semiarid. This work aims to present the optimal allocation of water, according to multiple uses and limited availability of water resources in the reservoir, from the simulation of the operation of the same, with the application of techniques to support decision making and performance evaluation alternatives for water use. The reservoir of Santa Cruz, the second largest reservoir of RN with storage capacity of approximately 600 million cubic meters, located about 20 km from the town of Apodi in RN, was conceived as a way to promote economic development in the region as well as the water supply of nearby towns. The techniques used are the simulation model of network flow ACQUANET and also the set of performance indicators. The results showed that the container has the capacity to serve up to 3,83m3/s flow required by existing uses, without any compromising the same. However, it was also observed that all anticipated future demands are implemented it will generate failures in meeting some uses
Resumo:
The interaction between land and water, resulting from dynamic agents, such as wind, waves and tides, characterizes the coastal zone as a dynamic environment that is constantly disturbed and that may alter the balance of natural and man-made environment. Such modifications may be intensified when considering the climate change. This environment is highly attractive for the development of economic activities and urbanization, current scenario of the city of Natal. Weighing the economic importance for the state and the physical environment in which the capital of Rio Grande do Norte is inserted, this study aims to identify and analyze vulnerabilities and impacts caused by the rising sea level in the municipality. To that end, we defined a coastline, delimited areas susceptible to flooding and presented some flood scenarios. This way we could identify and analyze the impacts of each flood scenario in its respective section. Finally, it appears that the coastal zone in which Natal is inserted is a fragile area that requires actions aimed at mitigating vulnerabilities and facing the problem that caused the rise in the mean sea level (MSL), and mitigating the presented vulnerability framework; it is necessary to implement actions that effectively contribute to the protection and adaptation of the most fragile areas
Resumo:
This study investigated the influence of the molar ratio, the phosphorus initial concentration, the mixture gradient, mixing time, pH and the secondary nucleation on struvite s crystallization in synthetic water in batch reactors. The study was divided into two stages. The first investigated struvite s crystallization at different Mg:N:P molar ratios and at different initial concentrations of magnesium, nitrogen and phosphorus. It was also evaluated the importance of secondary nucleation on the struvite s crystallization. In the second, five parameters were tested to evaluate their influence on the struvite s crystallization, which were: Mg:N:P molar ratio, initial concentration of phosphate, mixing time, mixture gradient and pH. The best conditions for struvite s crystallization were: Mg:N:P = 1,3:1:1 molar ratio; mixture gradient = 60 rpm, pH = 10.0, mixing time = 5 minutes and high initial concentrations of the constituent ions of struvite. Furthermore, the use of struvite crystals as seed influenced positively on the struvite s crystallization
Resumo:
With the need to deploy management and monitoring systems of natural resources in areas susceptible to environmental degradation, as is the case of semiarid regions, several works have been developed in order to find effective models and technically and economically viable. Therefore, this study aimed to estimate the daily actual evapotranspiration (ETr) through the application of the Surface Energy Balance Algorithm for Land (SEBAL), from remote sensing products, in a semiarid region, Seridó of the Rio Grande do Norte, and do the validation of these estimates using ETr values obtained by the Penman-Monteith (standard method of the Food and Agriculture Organization-FAO). The SEBAL is based on energy balance method, which allows obtaining the vertical latent heat flux (LE) with orbital images and, consequently, of the evapotranspiration through the difference of flows, also vertical, of heat in the soil (G), sensitive heat (H) and radiation balance (Rn). The study area includes the surrounding areas of the Dourado reservoir, located in the Currais Novos/RN city. For the implementation of the algorithm were used five images TM/Landsat-5. The work was divided in three chapters in order to facilitate a better discussion of each part of the SEBAL processing, distributed as follows: first chapter addressing the spatio-temporal variability of the biophysical variables; second chapter dealing with spatio-temporal distribution of instant and daily radiation balance; and the third chapter discussing the heart of the work, the daily actual evapotranspiration estimation and the validation than to the study area
Resumo:
The simulation of SES-Natal Ponta Negra: mitigation of environmental risks and predictive maintenance strategy was developed in the context of several operational irregularities in the pumping stations and sewage systems in the system Ponta Negra. Thus, the environmental risks and complaints against the company due to overflows of sewage into the public thoroughfare became common. This neighborhood has shown in recent years an increase of resident higher than the initial expectation of growth. In this sense presumed the large population growth and generation of sewers higher than expected, associated to the use of corrective maintenance and misuse of the system may be the main causes of operational failures occurring in the SES. This study aimed at analyzing the hydraulic behavior of SES Ponta Negrathrough numerical simulation of its operation associated to future scenarios of occupation. The SES Ponta Negra has a long lengthof collection networks and 6 pumping stations interconnected, being EE 1, 2, 4 coastal way, and beach Shopping interconnected EE3 to receives all sewers pumped from the rest pumping station and pumped to the sewage treatment station of neighborhood which consists of a facultative pond followed by three maturation ponds with disposal of treated effluent into infiltration ditches. Oncethey are connected with each other, the study was conducted considering the days and times of higher inflow for all lifts. Furthermore, with the aim of measuring the gatherer network failures were conducted data survey of on the networks. Thephysical and operational survey data was conducted between January/2011 and janeiro/2012. The simulation of the SES was developed with the aim ofdemonstrating its functioning, eithercurrently and in the coming years, based in population estimates and sewage flow. The collected data represents the current framework of the pumping stations of the SES Ponta Negra and served as input to the model developed in MS Excel ® spreadsheet which allowed simulating the behavior of SES in future scenarios. The results of this study show thatBeach Shopping Pumping Station is actually undersized and presents serious functioning problemsthatmay compromise the environmental quality of surrounding area. The other pumping stations of the system will reach itsmaximum capacity between 2013 and 2015, although the EE1 and EE3 demonstrateoperation capacity, even precariously, until 2017. Moreover, it was observed that the misuse of the network system, due to the input of both garbage and stormwater, are major factors of failures that occur in the SES. Finally, it was found that the corrective maintenance appliance, rather than predictive,has proven to beinefficient because of the serious failuresin the system, causing damage to the environment and health risks to users
Resumo:
Urban centers in Pitimbu Watershed use significant groundwater sources for public supply. Therefore, studies in Dunas Barreiras aquifer are relevant to expand knowledge about it and help manage water resources in the region. An essential tool for this management is the numerical modeling of groundwater flow. In this work, we developed a groundwater flow model for Pitimbu Watershed, using the Visual Modflow, version 2.7.1., which uses finite difference method for solving the govern equation of the dynamics of groundwater flow. We carried out the numerical simulation of steady-state model for the entire region of the basin. The model was built in the geographical, geomorphological and hydrogeological study of the area, which defined the boundary conditions and the parameters required for the numerical calculation. Owing to unavailability of current data based on monitoring of the aquifer it was not possible to calibrate the model. However, the simulation results showed that the overall water balance approached zero, therefore satisfying the equation for the three-dimensional behavior of the head water in steady state. Variations in aquifer recharge data were made to verify the impact of this contribution on the water balance of the system, especially in the scenario in which recharge due to drains and sinks was removed. According to the results generated by Visual Modflow occurred significantly hydraulic head lowering, ranging from 16,4 to 82 feet of drawdown. With the results obtained, it can be said that modeling is performed as a valid tool for the management of water resources in Pitimbu River Basin, and to support new studies
Resumo:
The potentially toxic cyanobacterial blooms in water bodies are spread across the globe, resulting in the loss of water quality and adverse effects on human health. In arid and semiarid regions, the hydrologic regime characterized by an annual cycle of drought and rain, change the volume and the retention time of the reservoir. Such changes affect the limnological characteristics and causing changes in composition and biomass community of cyanobacteria. The reservoir Cruzeta (Zmax = 8.7 m) is a eutrophic water supply source located in the semiarid tropical (Northeast Brazil). Raised the hypothesis that the hydrological regime of semi-arid tropical is a determining factor in the availability of resources in eutrophic water sources, which influences the composition of dominant species of cyanobacteria. The aim of this study was to analyze the changes in biomass and species composition of cyanobacteria for two annual hydrological cycles and evaluate factors drivers. The study was divided into five distinct periods (dry 2010, rain 2011, dry 2011, rain 2012, dry 2012). The dominant group found in all periods was Cyanobacteria (99% of total biomass), which contributed to the low diversity. The filamentous species Cylindrospermopsis raciborskii was present at both points in almost every study. The colonial species Microcystis panniformis and Sphaerocavum brasiliensis dominated only in periods with lower volumes of water. The diatoms contribute more to the biomass during the period of severe drought. The point near the dam (P1) had phytoplankton biomass larger than the point near the tributary (P2). The dominant species of colonial cyanobacteria lasted until the overflow in P1, and P2 this dominance was until the first rains. The redundancy analysis indicated that physical factors such as light availability and water level were the main factors driving the seasonal succession of phytoplankton. The composition of phytoplankton in spring was alternated by species of filamentous cyanobacteria in conditions of poor stability of the water column, such as Cylindrospermopsis raciborskii, and colonial species under conditions of high stability of the water column, such as Microcystis panniformis and Sphaerocavum brasiliensis. The extremes of torrential rains and severe droughts, governed by the hydrological regime of the semi-arid region led to the availability of resources in the watershed, directing the spatial and temporal dynamics of phytoplankton in the reservoir Cruzeta
Resumo:
The accelerated growth of urban regions have produced relevant effects on water resources. Urban regions need an adequate institutional structure that can be able to face environmental demands and the adverse effects of land use on water resources. This study aims at analysing land use effects on heavy metals concentration in sediments and water, as well as making a comparative analysis involving water physical-chemical parameters. Applied methodology included both in loco water parameters measurement and water and bed sediment sampling at 8 sections along the fluvial system. Sample analysis was performed in laboratory in order to measure heavy metal concentrations. It was measured metal concentrations of Al, Cu, Pb, Cd, Fe, Ni and Zn. Once the samples were subjected to acid digestion (method 3050B), concentration values were measured by using atomic absorption spectrometry by flame (ICP-FLAA). The analysis results were compared with normative reference, these standards is intended to assess the risks of toxic substances in sediment and water management programs. The normative reference used in this work were: a) Ontario Ministry of the Environment and Energy (OMEE, 1993) b) Normative Netherlands (VROM, 2000); c) Normative Canadian (CCME, 1999); d) United States Environmental Protection Agency (USEPA, 1977), e) CONAMA Resolution No. 344/2004; f) CONAMA Resolution No. 357/2005. The high concentrations of iron (38,750 mg.g-1), Lead (1100 mg.g-1), Nickel (100 μg.g-1) and zinc (180 μg.g-1) detected sediments confirm the state of degradation of the aquatic system. Iron concentrations (1.08 mg.L-1), Aluminum (0.6 mg.L-1) and phosphorus (0.05 mg.L-1) present in the water are outside the established standards for human consumption
Resumo:
The struvite precipitation in wastewater treatments plants offer advantages to obtaining a economically viable product, containing phosphorus, nitrogen and magnesium, in a bioavailable conditions to plants. The precipitation process requires ideal conditions, but all of these aspects are difficult to obtain and may result in resistance to collect crystals during the sedimentation process. Therefore, instead find the best conditions for precipitation, we propose the dissolved air flotation as another method to retrieve the crystals. The application of dissolved air flotation method to promote separation of struvite crystals from sewage supernatant, was evaluated in a precipitation-flotation reactor (flotatest) and were compared with the precipitation-sedimentation assays (jar test). Finally, were observed that the dissolved air flotation process was as feasible as sedimentation to promote struvite crystals separation, and the pH are the most influencer factor for an efficient separation
Resumo:
Experience in the use of stabilization ponds shows that this is a system with low cost, easy operation and maintenance and suitable for tropical countries. One of its disadvantages is due to high concentrations of suspended solids, mainly due to algal biomass in the effluents. Accordingly, the dissolved air flotation has been shown to be an efficient post-treatment technology. However, the efficiency of this process is related to coagulation and flocculation steps, as well as the adjustment of the involved variables in the process. The objective of this work was to evaluate the algae removal efficiency from wastewater stabilization ponds and the influence of the factors involved in the process using dissolved air flotation. For this, we used primary facultative and maturation effluents of ETE Ponta Negra in Natal. We did tests of coagulation, flocculation and flotation with the samples, using the equipment flotatest. In this process were tested coagulants aluminum sulfate and ferric chloride, and varied the factors pH, coagulant concentration, polymer concentration and rate of recirculation. At the end of the experiments were analyzed turbidity, suspended solids, color, COD and chlorophyll "a". These results were submitted to descriptive statistics to verify the efficiency of the process in general, and regression analysis to identify models that describe the process and demonstrate the factors that have greater influence on flotation. After step methodology, high values were found removal efficiency of suspended solids, reaching values greater than 90% in the best cases. It was concluded that flotation is more efficient in the facultative pond effluent using ferric chloride, and the variability of algae may negatively influence the process. Regression analyzes showed that pH is the most influential variable in the coagulation-flocculation-flotation, and its optimal value among the tested is 5.5 for both coagulants