740 resultados para INTEGRATED BACKSCATTER


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential of a fibre optic sensor, detecting light backscatter in a cheese vat during coagulation and syneresis, to predict curd moisture, fat loses and curd yield was examined. Temperature, cutting time and calcium levels were varied to assess the strength of the predictions over a range of processing conditions. Equations were developed using a combination of independent variables, milk compositional and light backscatter parameters. Fat losses, curd yield and curd moisture content were predicted with a standard error of prediction (SEP) of +/- 2.65 g 100 g(-1) (R-2 = 0.93), +/- 0.95% (R-2 = 0.90) and +/- 1.43% (R-2 = 0.94), respectively. These results were used to develop a model for predicting curd moisture as a function of time during syneresis (SEP = +/- 1.72%; R-2 = 0.95). By monitoring coagulation and syneresis, this sensor technology could be employed to control curd moisture content, thereby improving process control during cheese manufacture. (c) 2007 Elsevier Ltd. All rights reserved..

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An NIR reflectance sensor, with a large field of view and a fibre-optic connection to a spectrometer for measuring light backscatter at 980 nm, was used to monitor the syneresis process online during cheese-making with the goal of predicting syneresis indices (curd moisture content, yield of whey and fat losses to whey) over a range of curd cutting programmes and stirring speeds. A series of trials were carried out in an 11 L cheese vat using recombined whole milk. A factorial experimental design consisting of three curd stirring speeds and three cutting programmes, was undertaken. Milk was coagulated under constant conditions and the casein gel was cut when the elastic modulus reached 35 Pa. Among the syneresis indices investigated, the most accurate and most parsimonious multivariate model developed was for predicting yield of whey involving three terms, namely light backscatter, milk fat content and cutting intensity (R2 = 0.83, SEy = 6.13 g/100 g), while the best simple model also predicted this syneresis index using the light backscatter alone (R2 = 0.80, SEy = 6.53 g/100 g). In this model the main predictor was the light backscatter response from the NIR light back scatter sensor. The sensor also predicted curd moisture with a similar accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Integrated Arable Farming Systems (IAFS) projects utilise a range of novel and different farming techniques, often associated with optimising or reducing the use of inputs. Here, data is presented from the LINK-IFS project which suggests that, although input levels are being reduced, the overall profitability of the system can be maintained. The effect of thus reduction in inputs, however, in terms of impact on key environmental indicators is unclear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Integrated Arable Farming Systems (IAFS), which involve a reduction in the use of off-farm inputs, are attracting considerable research interest in the UK. The objectives of these systems experiments are to compare their financial performance with that from conventional or current farming practices. To date, this comparison has taken little account of any environmental benefits (or disbenefits) of the two systems. The objective of this paper is to review the assessment methodologies available for the analysis of environmental impacts. To illustrate the results of this exercise, the methodology and environmental indicators chosen are then applied to data from one of the LINK - Integrated Farming Systems experimental sites. Data from the Pathhead site in Southern Scotland are used to evaluate the use of invertebrates and nitrate loss as environmental indicators within IAFS. The results suggest that between 1992 and 1995 the biomass of earthworms fell by 28 kg per hectare on the integrated rotation and rose by 31 kg per hectare on the conventional system. This led to environmental costs ranging between £2.24 and £13.44 per hectare for the integrated system and gains of between £2.48 and £14.88 for the conventional system. In terms of nitrate, the integrated system had an estimated loss of £72.21 per hectare in comparison to £149.40 per hectare on the conventional system. Conclusions are drawn about the advantages and disadvantages of this type of analytical framework. Keywords: Farming systems; IAFS; Environmental valuation; Economics; Earthworms; Nitrates; Soil fauna

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Integrated Arable Farming Systems are examined from the perspective of the farmer considering the use of such techniques, and data are presented which suggest that the uptake of the approach may expose the manager to a greater degree of risk. Observations are made about the possible uptake of such systems in the UK and the implications this may have for agricultural and environmental policy in general.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Integrated Arable Farming Systems are examined from the perspective of the farmer considering the use of such techniques, and data are presented which suggest that the uptake of the approach may expose the manager to a greater degree of risk. Observations are made about the possible uptake of such systems in the UK and the implications this may have for agricultural and environmental policy in general.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Parasitic infections cause a myriad of responses in their mammalian hosts, on immune as well as on metabolic level. A multiplex panel of cytokines and metabolites derived from four parasite-rodent models, namely, Plasmodium berghei-mouse, Trypanosoma brucei brucei-mouse, Schistosoma mansoni-mouse, and Fasciola hepatica-rat were statistically coanalyzed. 1H NMR spectroscopy and multivariate statistical analysis were used to characterize the urine and plasma metabolite profiles in infected and noninfected animals. Each parasite generated a unique metabolic signature in the host. Plasma cytokine concentrations were obtained using the ‘Meso Scale Discovery’ multi cytokine assay platform. Multivariate data integration methods were subsequently used to elucidate the component of the metabolic signature which is associated with inflammation and to determine specific metabolic correlates with parasite-induced changes in plasma cytokine levels. For example, the relative levels of acetyl glycoproteins extracted from the plasma metabolite profile in the P. berghei-infected mice were statistically correlated with IFN-γ, whereas the same cytokine was anticorrelated with glucose levels. Both the metabolic and the cytokine data showed a similar spatial distribution in principal component analysis scores plots constructed for the combined murine data, with samples from all infected animals clustering according to the parasite species and whereby the protozoan infections (P. berghei and T. b. brucei) grouped separately from the helminth infection (S. mansoni). For S. mansoni, the main infection-responsive cytokines were IL-4 and IL-5, which covaried with lactate, choline, and D-3-hydroxybutyrate. This study demonstrates that the inherently differential immune response to single and multicellular parasites not only manifests in the cytokine expression, but also consequently imprints on the metabolic signature, and calls for in-depth analysis to further explore direct links between immune features and biochemical pathways.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A solution of the lidar equation is discussed, that permits combining backscatter and depolarization measurements to quantitatively distinguish two different aerosol types with different depolarization properties. The method has been successfully applied to simultaneous observations of volcanic ash and boundary layer aerosol obtained in Exeter, United Kingdom, on 16 and 18 April 2010, permitting the contribution of the two aerosols to be quantified separately. First a subset of the atmospheric profiles is used where the two aerosol types belong to clearly distinguished layers, for the purpose of characterizing the ash in terms of lidar ratio and depolarization. These quantities are then used in a three‐component atmosphere solution scheme of the lidar equation applied to the full data set, in order to compute the optical properties of both aerosol types separately. On 16 April a thin ash layer, 100–400 m deep, is observed (average and maximum estimated ash optical depth: 0.11 and 0.2); it descends from ∼2800 to ∼1400 m altitude over a 6‐hour period. On 18 April a double ash layer, ∼400 m deep, is observed just above the morning boundary layer (average and maximum estimated ash optical depth: 0.19 and 0.27). In the afternoon the ash is entrained into the boundary layer, and the latter reaches a depth of ∼1800 m (average and maximum estimated ash optical depth: 0.1 and 0.15). An additional ash layer, with a very small optical depth, was observed on 18 April at an altitude of 3500–4000 m. By converting the lidar optical measurements using estimates of volcanic ash specific extinction, derived from other works, the observations seem to suggest approximate peak ash concentrations of ∼1500 and ∼1000 mg/m3,respectively, on the two observations dates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Air distribution systems are one of the major electrical energy consumers in air-conditioned commercial buildings which maintain comfortable indoor thermal environment and air quality by supplying specified amounts of treated air into different zones. The sizes of air distribution lines affect energy efficiency of the distribution systems. Equal friction and static regain are two well-known approaches for sizing the air distribution lines. Concerns to life cycle cost of the air distribution systems, T and IPS methods have been developed. Hitherto, all these methods are based on static design conditions. Therefore, dynamic performance of the system has not been yet addressed; whereas, the air distribution systems are mostly performed in dynamic rather than static conditions. Besides, none of the existing methods consider any aspects of thermal comfort and environmental impacts. This study attempts to investigate the existing methods for sizing of the air distribution systems and proposes a dynamic approach for size optimisation of the air distribution lines by taking into account optimisation criteria such as economic aspects, environmental impacts and technical performance. These criteria have been respectively addressed through whole life costing analysis, life cycle assessment and deviation from set-point temperature of different zones. Integration of these criteria into the TRNSYS software produces a novel dynamic optimisation approach for duct sizing. Due to the integration of different criteria into a well- known performance evaluation software, this approach could be easily adopted by designers in busy nature of design. Comparison of this integrated approach with the existing methods reveals that under the defined criteria, system performance is improved up to 15% compared to the existing methods. This approach is interpreted as a significant step forward reaching to the net zero emission building in future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we briefly describe the results of a 3 year project examining the use of Health Information Technologies (e.g., electronic patient record systems) to deliver integrated care. In particular, we focus on one group of patient (the frail elderly) and efforts to design an e-health supported healthcare pathway (the frail elderly pathway – FEP). The aim of FEP is to bring together clinicians and staff from health and social care and allow them to share patient information. Our findings show that progress in delivering a fully-supported and working FEP has been slow, not least because of the difficulties experienced by healthcare staff in using current IT systems. In addition, there are many strategic and technical issues which remain unresolved (e.g., systems interoperability).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a new satellite mission to deliver high quality measurements of upper air water vapour. The concept centres around a LiDAR in limb sounding by occultation geometry, designed to operate as a very long path system for differential absorption measurements. We present a preliminary performance analysis with a system sized to send 75 mJ pulses at 25 Hz at four wavelengths close to 935 nm, to up to 5 microsatellites in a counter-rotating orbit, carrying retroreflectors characterized by a reflected beam divergence of roughly twice the emitted laser beam divergence of 15 µrad. This provides water vapour profiles with a vertical sampling of 110 m; preliminary calculations suggest that the system could detect concentrations of less than 5 ppm. A secondary payload of a fairly conventional medium resolution multispectral radiometer allows wide-swath cloud and aerosol imaging. The total weight and power of the system are estimated at 3 tons and 2,700 W respectively. This novel concept presents significant challenges, including the performance of the lasers in space, the tracking between the main spacecraft and the retroreflectors, the refractive effects of turbulence, and the design of the telescopes to achieve a high signal-to-noise ratio for the high precision measurements. The mission concept was conceived at the Alpbach Summer School 2010.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador: