995 resultados para Grupo Light
Resumo:
In work of this nature it is advisable to state definitely the problem attempted in order that the reader may have a clear understanding of the object of the work undertaken. The problem involved is to determine the efficiency and inefficiency in the operation of the Bureau of Power and Light of Los Angeles, California, as it exists at the present time. This will be more on the order of a government investigation than a purely engineering thesis. An engineering thesis consists or reports based on experiments and tests, etc., while the present undertaking will consist of investigation of the facts concerning the organization, operation and conduct of the business of the Bureau of Power and Light. The facts presented were obtained from several sources: (1) the writer's knowledge of the business; (2) books written on municipal ownership; (3) reports published by the Bureau, and (4) personal interviews with men connected with the organization. I have endeavored to draw conclusions from the facts thus obtained, as to the present status of the Bureau of Power and Light.
Resumo:
A nonvolatile recording scheme is proposed using LiNbO3:Ce:Cu crystals and modulated UV light to record gratings simultaneously in two centres and using red light to bleach the grating in the shallow centre to realize persistent photorefractive holographic storage. Compared with the normal UV-sensitized nonvolatile holographic system, the amplitude of refractive-index changes is greatly increased and the recording sensitivity is significantly enhanced by recording with UV light in the LiNbO3:Ce:Cu crystals. Based on jointly solving the two-centre material equations and the coupled-wave equations, temporal evolutions of the photorefractive grating and the diffraction effciency are effectively described and numerically analysed. Roles of doping levels and recording-beam intensity are discussed in detail. Theoretical results confirm and predict experimental results.
Resumo:
Modulated UV light is used to increase the sensitivity of the two-centre holographic recording. Inherent mechanisms of nonvolatile holographic recording in oxidized and reduced crystals are numerically analysed based on solving the two-centre material equations modilied for UV-Iight recording. Experiments verification is performed with an oxidized crystal and a reduced crystal, and the role of UV intensity on the sensitivity is presented.
Resumo:
Nonvolatile holographic recording is performed with green light in LiNbO3:Ce:Cu crystals. The refractive-index change and the recording sensitivity are times better than those obtained by recording with red light, and higher optical fixing efficiency is obtained. Correspondingly, theoretical investigations are given.
Resumo:
I. PREAMBLE AND SCOPE
Brief introductory remarks, together with a definition of the scope of the material discussed in the thesis, are given.
II. A STUDY OF THE DYNAMICS OF TRIPLET EXCITONS IN MOLECULAR CRYSTALS
Phosphorescence spectra of pure crystalline naphthalene at room temperature and at 77˚ K are presented. The lifetime of the lowest triplet 3B1u state of the crystal is determined from measurements of the time-dependence of the phosphorescence decay after termination of the excitation light. The fact that this lifetime is considerably shorter in the pure crystal at room temperature than in isotopic mixed crystals at 4.2˚ K is discussed, with special importance being attached to the mobility of triplet excitons in the pure crystal.
Excitation spectra of the delayed fluorescence and phosphorescence from crystalline naphthalene and anthracene are also presented. The equation governing the time- and spatial-dependence of the triplet exciton concentration in the crystal is discussed, along with several approximate equations obtained from the general equation under certain simplifying assumptions. The influence of triplet exciton diffusion on the observed excitation spectra and the possibility of using the latter to investigate the former is also considered. Calculations of the delayed fluorescence and phosphorescence excitation spectra of crystalline naphthalene are described.
A search for absorption of additional light quanta by triplet excitons in naphthalene and anthracene crystals failed to produce any evidence for the phenomenon. This apparent absence of triplet-triplet absorption in pure crystals is attributed to a low steady-state triplet concentration, due to processes like triplet-triplet annihilation, resulting in an absorption too weak to be detected with the apparatus used in the experiments. A comparison of triplet-triplet absorption by naphthalene in a glass at 77˚ K with that by naphthalene-h8 in naphthalene-d8 at 4.2˚ K is given. A broad absorption in the isotopic mixed crystal triplet-triplet spectrum has been tentatively interpreted in terms of coupling between the guest 3B1u state and the conduction band and charge-transfer states of the host crystal.
III. AN INVESTIGATION OF DELAYED LIGHT EMISSION FROM Chlorella Pyrenoidosa
An apparatus capable of measuring emission lifetimes in the range 5 X 10-9 sec to 6 X 10-3 sec is described in detail. A cw argon ion laser beam, interrupted periodically by means of an electro-optic shutter, serves as the excitation source. Rapid sampling techniques coupled with signal averaging and digital data acquisition comprise the sensitive detection and readout portion of the apparatus. The capabilities of the equipment are adequately demonstrated by the results of a determination of the fluorescence lifetime of 5, 6, 11, 12-tetraphenyl-naphthacene in benzene solution at room temperature. Details of numerical methods used in the final data reduction are also described.
The results of preliminary measurements of delayed light emission from Chlorella Pyrenoidosa in the range 10-3 sec to 1 sec are presented. Effects on the emission of an inhibitor and of variations in the excitation light intensity have been investigated. Kinetic analysis of the emission decay curves obtained under these various experimental conditions indicate that in the millisecond-to-second time interval the decay is adequately described by the sum of two first-order decay processes. The values of the time constants of these processes appear to be sensitive both to added inhibitor and to excitation light intensity.
Resumo:
A odontologia moderna utiliza métodos e técnicas ultraconservadores no intuito de corrigir os diversos tipos de alterações cromáticas observadas clinicamente. Os meios empregados baseiam-se na utilização de substâncias químicas à base de peróxidos presentes em diversas concentrações. O presente estudo objetivou avaliar a microestrutura de três resinas compostas fotossensíveis submetidas à aplicação de um agente clareador a base de peróxido de hidrogênio a 35% (Whiteness HP Maxx - fabricante: FGM), ativado por uma fonte híbrida de energia luminosa (Aparelho de Laser-Led Whitening Lase, fabricante: DMC). Para isso, foram confeccionados 30 corpos de prova (CDP) 10 para cada grupo, no formato de discos, com 13 mm de diâmetro e 2,0 mm de espessura em uma matriz de teflon e aço inox, fotoativados por um aparelho de luz halógena convencional (Optilux 401 - Demetron/UR) por 40 segundos com densidade de potência média igual a 450 mW/cm2. Os grupos foram dispostos da seguinte forma: Grupo 1 - resina microparticulada (Durafill VS - fabricante: Heraeus Kulzer); Grupo 2 - resina micro-híbrida (Esthet-X - fabricante: Dentsply); e Grupo 3 resina nanoparticulada (Filtek Supreme XT fabricante: 3M ESPE). Todos os materiais restauradores utilizados eram da cor A2. Após serem submetidos à sequência de acabamento e polimento os CDP foram armazenados por sete dias em saliva artificial, limpos em ultra-som, envelhecidos artificialmente de acordo com a norma ASTM G 154. Os CDP dos três grupos foram aleatoriamente divididos em 2 subgrupos (ST sem tratamento e CT com tratamento) e finalmente submetidos aos experimentos. Os CDP dos subgrupos 1-ST, 2- ST e 3-ST foram triturados (SPEX SamplePrep 8000-series, marca: Mixer/Mills) seguido pela verificação dos materiais por meio de um espectrômetro (marca/modelo: Shimadzu EDX 720) para certificação da ausência de elementos pertencentes ao meio de moagem e por fim foram levados a um difrator de raios-X (marca / modelo: Philips -PW 3040 -X'Celerator- 40kV; 30mA; (λ): CuKα; 0,6; 0,2mm; 0,05 (2θ); 2s; 10-90 (2θ). Em seguida os CDP dos subgrupos 1-CT, 2- CT e 3-CT foram tratados com o peróxido de hidrogênio de acordo com o protocolo do fabricante para a fonte híbrida luminosa de energia selecionada, totalizando 9 aplicações de 10 minutos, onde eram respeitados os tempos de 3 minutos de ativação por 20 segundos de descanso, finalizando 10 minutos em cada aplicação. Mediante a este tratamento, os CDP dos subgrupos CT eram verificados e avaliados pelo mesmo método descrito anteriormente. Após interpretação gráfica, análise comparativa por meio do processamento digital das imagens no programa KS400 3.0 (Carl Zeiss Vision) e análise de concordância por cinco avaliadores calibrados utilizando um escore, pôde-se concluir que houve degradação estrutural e que as estruturas cristalinas das resinas estudadas foram afetadas de forma distinta quando tratadas pelo peróxido de hidrogênio; onde observou-se que: Grupo 1 > Grupo 3 > Grupo 2. Foi sugerido a realização de novos estudos, relacionados à interação do peróxido de hidrogênio às resinas compostas.
Resumo:
By sensitizing with 514 nm green light, 488 nm blue light and 390 nm ultraviolet light, respectively, recording with 633 nm red light, effect of wavelength of sensitizing light on holographic storage properties in LiNbO3:Fe:Ni crystal is investigated in detail. It is shown that by shortening the wavelength of sensitizing light gradually, nonvolatile holographic recording properties of oxidized LiNbO3:Fe:Ni crystal is optimized gradually, 390 nm ultraviolet light is the best as the sensitizing light. Considering the absorption of sensitizing light, to obtain the best performance in two-center holographic recording we must choose a sensitizing wavelength that is long enough to prevent unwanted absorptions (band-to-band, etc.) and short enough to result in efficient sensitization from the deep traps. So in practice a trade-off is always needed. Explanation is presented theoretically. (c) 2005 Elsevier GmbH. All rights reserved.
Resumo:
The electro-optic effect in uniaxial crystals for light propagating near the optic axis with any polarization has been analyzed. The passive and the electrically induced birefringences and the rotation of polarization direction in crystals have been calculated, and the conoscopic interference figures under orthogonal polariscopes for different polarizer directions have been plotted. The extinction areas caused by the rotation of polarization direction in crystals change with the polarizer direction, but the two heads of the induced optical axes do not vary, which are always on the induced principal axis with bigger refractive index. The directions of polariscopes are always extinction, and the +/- 45 degrees directions with polarizer are always complete transmission. The conoscopic interference figures for LiNbO3 crystals have been demonstrated experimentally by rotating polariscopes directions, which accord with the theoretically calculating plots. (c) 2006 Elsevier GmbH. All rights reserved.
Resumo:
Experimental measurements of rate of energy loss were made for protons of energy .5 to 1.6 MeV channeling through 1 μm thick silicon targets along the <110>, <111>, and <211> axial directions, and the {100}, {110}, {111}, and {211} planar directions. A .05% resolution automatically controlled magnetic spectrometer was used. The data are presented graphically along with an extensive summary of data in the literature. The data taken cover a wider range of channels than has previously been examined, and are in agreement with the data of F. Eisen, et al., Radd. Eff. 13, 93 (1972).
The theory in the literature for channeling energy loss due to interaction with local electrons, core electrons, and distant valence electrons of the crystal atoms is summarized. Straggling is analyzed, and a computer program which calculates energy loss and straggling using this theory and the Moliere approximation to the Thomas Fermi potential, VTF, and the detailed silicon crystal structure is described. Values for the local electron density Zloc in each of the channels listed above are extracted from the data by graphical matching of the experimental and computer results.
Zeroth and second order contributions to Zloc as a function of distance from the center of the channel were computed from ∇2VTF = 4πρ for various channels in silicon. For data taken in this work and data of F. Eisen, et al., Rad. Eff. 13, 93 (1972), the calculated zeroth order contribution to Zloc lies between the experimentally extracted Zloc values obtained by using the peak and the leading edge of the transmission spectra, suggesting that the observed straggling is due both to statistical fluctuations and to path variation.
Resumo:
The (He3, n) reactions on B11, N15, O16, and O18 targets have been studied using a pulsed-beam time-of-flight spectrometer. Special emphasis was placed upon the determination of the excitation energies and properties of states with T = 1 (in Ne18), T = 3/2 (in N13 and F17) and T = 2 (in Ne20). The identification of the T = 3/2 and T = 2 levels is based on the structure of these states as revealed by intensities and shapes of angular distributions. The reactions are interpreted in terms of double stripping theory. Angular distributions have been compared with plane and distorted wave stripping theories. Results for the four reactions are summarized below:
1) O16 (He3, n). The reaction has been studied at incident energies up to 13.5 MeV and two previously unreported levels in Ne18 were observed at Ex = 4.55 ± .015 MeV (Γ = 70 ± 30 keV) and Ex = 5.14 ± .018 MeV (Γ = 100 ± 40 keV).
2) B11 (He3, n). The reaction has been studied at incident energies up to 13.5 MeV. Three T = 3/2 levels in N13 have been identified at Ex = 15.068 ± .008 MeV (Γ ˂ 15 keV), Ex = 18.44 ± .04, and Ex 18.98 ± .02 MeV (Γ = 40 ± 20 keV).
3) N15 (He3, n). The reaction has been studied at incident energies up to 11.88 MeV. T = 3/2 levels in F17 have been identified at Ex = 11.195 ± .007 MeV (Γ ˂ 20 keV), Ex = 12.540 ± .010 MeV (Γ ˂ 25 keV), and Ex = 13.095 ± .009 MeV (Γ ˂ 25 keV).
4) O18 (He3, n). The reaction has been studied at incident energies up to 9.0 MeV. The excitation energy of the lowest T = 2 level in Ne20 has been found to be 16.730 ± .006 MeV (Γ ˂ 20 keV).
Angular distributions of the transitions leading to the above higher isospin states are well described by double stripping theory. Analog correspondences are established by comparing the present results with recent studies (t, p) and (He3, p) reactions on the same targets.
Resumo:
Este estudo teve por objetivo avaliar, in vitro, a influência do material de confecção das matrizes, traçando um perfil da conversão monomérica de um compósito micro-híbrido, além de avaliar qual dos materiais testados mais se assemelha a uma matriz de dentina. A avaliação foi feita através da análise do grau de conversão (GC). Foram confeccionadas 3 matrizes bipartidas, sendo estas de teflon negro, tefon branco e aço inoxidável, ambas com 10mm de diâmetro e 2 mm de profundidade. Para o grupo controle foi utilizado um incisivo central bovino, o qual teve sua face vestibular aplainada em uma lixadeira sob refrigeração constante, com o auxílio de uma lixa de carbeto de silício, número 800. Após, este dente foi preparado com uma broca diamantada número 2294 (KG Sorensen) em alta rotação, própria para a preparação de cavidades padronizadas para ensaios de laboratório, apresentando um limitador de penetração. Em seguida, com um motor de baixa rotação foi realizado o acabamento das paredes, obtendo-se uma cavidade de 2,0 mm de profundidade por 9,0 mm de diâmetro. Pela palatina desse dente, com uma broca carbide cilíndrica de numeração 2056 (KG Sorensen), fez-se uma penetração até se obter uma parede de dentina extremamente fina, porém sem que esta fosse rompida. Assim, com uma agulha, fez-se uma pequena perfuração no centro dessa dentina para que este instrumental servisse como um pino para remoção do corpo de prova de dentro da matriz de dente. Os corpos de prova (CP) foram obtidos a partir da inserção do compósito no interior da perfuração das matrizes em um único incremento e cobertos na superfície externa com uma matriz de poliéster mais uma lamínula de vidro. Os CP foram fotopolimerizados por 40 s pela fonte de luz halógena Optilux 501 (Demetron), com 500 mW/cm. Imediatamente após a polimerização, os corpos de prova eram submetidos no topo e na base para a análise de espectrometria no infravermelho para a determinação da profundidade de polimerização, pela técnica do filme vazado para o compósito não polimerizado e pela técnica da pastilha de brometo de potássio (KBr) para o compósito polimerizado. Foram confeccionados 5 CP de cada grupo. Em cada grupo, o compósito da base e do topo das amostras foi moído até se obter de 1,5 a 2,0 mg de pó e misturado com 70 mg de KBr, para obtenção da pastilha de KBr. Foi feita a análise de espectrofotometria no infravermelho por Transformada de Fourier (FTIR). As absorções selecionadas para o cálculo foram 1610 cm-1 e 1637 cm-1, os picos dos espectros das ligações dos carbonos aromáticos e alifáticos, respectivamente. Os dados obtidos foram tratados estatisticamente. Os grupos Gr1B, Gr2B, Gr3B e Gr4B representam, respectivamente, as bases dos CP confeccionados pelas matrizes de DB, TN, TB e AI. Já os Gr1T, Gr2T, Gr3T e Gr4T representam os topos. Médias (%) e DP: Gr1T (46,461,99), Gr2T (39,864,51), Gr3T (44,053,44) e Gr4T (38,045,08). Gr1B (40,441,49), Gr2B (36,153,81), Gr3B (40,093,18) e Gr4B (35,593,35). Em posse dos resultados, pôde-se concluir que os grupos do teflon negro, teflon branco e aço inoxidável não apresentaram diferenças entre o grau de conversão do topo e da base, enquanto que o grupo da dentina apresentou maior conversão do topo. Comparando as matrizes entre elas, pôde-se perceber que no topo, o GC do dente bovino é maior que o GC do aço inoxidável e do que o de teflon negro, o GC do teflon branco é maior que o GC do aço inoxidável e do que o de teflon negro. Já o topo dos grupos de dente bovino e teflon banco foram semelhantes. Nas bases dos CPs, não houve diferença significativa entre os grupos testados. De acordo com os resultados obtidos no experimento, pôde-se concluir que nos grupos do teflon negro, teflon branco e aço inoxidável não houve diferença entre 0 e 2 mm, ou seja, topo e base, o que mostra que o material de confecção da matriz não influênciou o grau de conversão do compósito. Já para o grupo da matriz de dentina, o topo apresentou valor de conversão monomérica maior, mostrando que, neste caso, o material da matriz interferiu no grau de conversão. Pode-se perceber também que existe uma tendência da matriz de teflon branco se assemelhar mais a matriz de dentina, pois foi o único grupo que apresentou semelhança nos valores de conversão monomérica no topo das amostras. Porém analisando a base das amostras, percebe-se que todos os grupos se comportaram de forma semelhante, obtendo valores do grau de conversão sem diferença significante.
Resumo:
A new method for measuring the birefringence dispersion in polarization-maintaining fibers (PMFs) with high sensitivity and accuracy is presented. The method employs white-light interferences between two orthogonally polarized modes of PMFs. The group birefringence of the fiber is calibrated first. Then the birefringence dispersion and its variation along different fiber sections are acquired by analyzing the broadening of interferograms at different fiber lengths. The main sources of error are investigated. Bireffingence dispersions of two PANDA fibers at their operation wavelength are measured to be 0.011 ps/(km nm) and 0.018 ps/(km nm). A measurement repeatability of 0.001 ps/(km nm) is achieved. (C) 2007 Optical Society of America.
Resumo:
Within the wavelength range from 351 to 799 nm, the different reductions of nucleation field induced by the focused continuous laser irradiation are achieved in the 5 mol % MgO-doped congruent LiNbO3 crystals. The reduction proportion increases exponentially with decreasing irradiation wavelength and decreases exponentially with increasing irradiation wavelength. At one given wavelength, the reduction proportion increases exponentially with increasing irradiation intensity. An assumption is proposed that the reduction of nucleation field is directly related to the defect structure of crystal lattice generated by the complex coaction of incident irradiation field and external electric field. (c) 2007 American Institute of Physics.