688 resultados para Fretting corrosion
Resumo:
PhD thesis in Biomedical Engineering
Resumo:
Tese de Doutoramento em Engenharia Civil
Resumo:
Tese de Doutoramento - Leaders for Technical Industries (LTI) - MIT Portugal
Resumo:
In spite of all innovations in stent design, commonly used metallic stents present several problems such as corrosion, infection and restenosis, leading to health complications or even death of patients. In this context, the present paper reports a systematic investigation on designing and development of 100% fiber based stents, which can eliminate or minimize the problems with existing metallic stents. For this purpose, braided stents were produced by varying different materials, structural and process parameters such as mono-filament type and diameter, braiding angle and mandrel diameter. The influence of these design parameters on mechanical behavior as well as stent's porosity was thoroughly investigated, and suitable parameters were selected for developing a stentwith mechanical characteristics and porosity matching with the commercial stents. According to the experimental results, the best performance was achieved with a polyester stent designed with 0.27 mm monofilament diameter, braiding angle of 35° and mandrel diameter of 6 mm, providing similar properties to commercial Nitinol stents.
Resumo:
Concrete is the primary construction material for civil infrastructures and generally consists of cement, coarse aggregates, sand, admixtures and water. Cementitious materials are characterized by quasi-brittle behaviour and susceptible to cracking [1]. The cracking process within concrete begins with isolated nano-cracks, which then conjoin to form micro-cracks and in turn macro-cracks. Formation and growth of cracks lead to loss of mechanical performance with time and also make concrete accessible to water and other degrading agents such as CO2, chlorides, sulfates, etc. leading to strength loss and corrosion of steel rebars. To improve brittleness of concrete, reinforcements such as polymeric as well as glass and carbon fibers have been used and microfibers improved the mechanical properties significantly by delaying (but could not stop) the transformation of micro-cracks into macro forms [2]. This fact encouraged the use of nano-sized fillers in concrete to prevent the growth of nano-cracks transforming in to micro and macro forms. Nanoparticles like SiO2, Fe2O3, and TiO2 led to considerable improvement in mechanical performance and moreover, nano-TiO2 helped to remove organic pollutants from concrete surfaces [3].
Resumo:
Stents are rigid and perforated tubular structures, which are inserted into blood vessels in order to prevent or inhibit the constriction of blood flow, restoring the normal blood flow, when blood vessels are clogged, being used in 70% of angioplasties. These medical devices assume great importance in the treatment of cardiovascular diseases (CVD) which are the leading cause of death worldwide. In the European Union CVD account for 40% of deaths and assume an estimated annual cost of 196 billion euros[1]. Stents must possess certain requirements, in order to, adequately, perform its function, such as biocompatibility (so that its use does not c ause damage on the health of its user), mechanical strength, radiopacity (so that it is easy to view), longitudinal flexibility, ease of handling, corrosion resistance and having high strength and high radial expansion ability to recover. Stents can be made of different materials, but metals, particularly stainless steel, are the most common. However, metallic stents present several dRawbacks such as corrosion and restenosis, leading to health complications for the patient, or even death. In order to minimize these disadvantages, new materials, like fibrous materials, have been used [2]. Monofilaments present high potential for stents development because, in addition to its biocompatibility, these materials allow the application of various surface treatments, such as antibacterial coatings. Furthermore, monofilament exhibit excellent mechanical properties, like greater stiffness and good results when subjected to compression, tensile and bending forces, since these forces will be directly supported by the monofilament [3]. To minimize the reaction of the human body and Limit the adhesion of microorganisms to the stent surface, some coatings have been developed, including the use of novel metals with antimicrobial properties, like silver. The main objective of this study was the development of fibrous stents, incorporation of silver oxide nanocoating. For the development of the stent, polyester monofilaments with 0.27mm of diameter were used in braiding technology, with a mandrel diameter of 6mm and a braiding angle of 35⁰. The mechanical behaviour of the stent were evaluated by mechanical testing under longitudinal and radial compression, bending. The results of compressive strength tests are according with value from literature: 1.13 to 2.9 N for radial compression and 0. 16-5.28N to longitudinal compression. From literature is also possible to verify that stents must present 75% of unchanged diameter during the bending test and must possess a porosity between 70% and 80% [4]. The produced polyester stent presents values of 1.29N for radial compression, 0.23N for longitudinal compression, 80% of porosity and 85.5% of unchanged diameter, during bending tests. For the antibacterial functionalization, silver oxide nanocoatings were prepared, through reactive magnetron g, with an Ag target in an Ar +O2 atmosphere. In order to evaluate the nanostructure and morphology of the coatings, d ifferent technique s like X-ray diffraction (XRD), scanning electron microscopy (SEM) and and X- ray photoelectron spectroscopy (XPS were used. From the analyses of XRD it is possible to verify that the peaks corresponds to planes of Ag2 O and MATERIAIS 2015 Porto, 21-23 June, 2015 characterize a cubic phase. The presence of Ag2 O is corroborated by XPS spectrum, where it is possible to observe silver, not only, in oxide state, but a lso in mettalic state, and it is possible to verify the presence of silver clusters, confirmed by SEM analysis. Films’ roughness and topography, parameters influencing the wettability of the surface and microorganism adhesion, were measured by Atomic Force Microscopy (AFM), and it was observed that the roughness is very low (under 10 nm). Coatings’ hydrophobicity and surface tension parameters were determined by contact angle measurement, and it was verified the hydrophobic behavior of the coatings. For antibacterial tests were used Staphylococcus epidermidis strain (IE186) and Staphylococcus aureus(ATCC 6538), and halo inhibition zone tests were realized. Ag+release rates were studied by means of inductively coupled plasma mass spectrometry (ICP -MS). The obtained results suggest that silver oxide coatings do not modify significantly surface properties of the substrate, like hydrophobicity and roughness, and present antimicrobial properties for both bacteria used.
Resumo:
Dissertação de mestrado integrado em Engenharia Biomédica
Resumo:
Dissertação de mestrado integrado em Engenharia de Materiais
Resumo:
Dissertação de mestrado integrado em Engenharia de Materiais
Resumo:
Dissertação de mestrado integrado em Engenharia de Materiais
Resumo:
Dissertação de mestrado integrado em Engenharia Civil
Resumo:
Tese de Doutoramento (Programa doutoral em Engenharia de Materiais)
Resumo:
PURPOSE: Milk fat globule-epidermal growth factor-factor VIII (MFGE8) is necessary for diurnal outer segment phagocytosis and promotes VEGF-dependent neovascularization. The prevalence of two single nucleotide polymorphisms (SNP) in MFGE8 was studied in two exsudative or "wet" Age-related Macular Degeneration (AMD) groups and two corresponding control groups. We studied the effect of MFGE8 deficiency on retinal homeostasis with age and on choroidal neovascularization (CNV) in mice. METHODS: The distribution of the SNP (rs4945 and rs1878326) of MFGE8 was analyzed in two groups of patients with "wet" AMD and their age-matched controls from Germany and France. MFGE8-expressing cells were identified in Mfge8(+/-) mice expressing ß-galactosidase. Aged Mfge8(+/-) and Mfge8(-/-) mice were studied by funduscopy, histology, electron microscopy, scanning electron microscopy of vascular corrosion casts of the choroid, and after laser-induced CNV. RESULTS: rs1878326 was associated with AMD in the French and German group. The Mfge8 promoter is highly active in photoreceptors but not in retinal pigment epithelium cells. Mfge8(-/-) mice did not differ from controls in terms of fundus appearance, photoreceptor cell layers, choroidal architecture or laser-induced CNV. In contrast, the Bruch's membrane (BM) was slightly but significantly thicker in Mfge8(-/-) mice as compared to controls. CONCLUSIONS: Despite a reproducible minor increase of rs1878326 in AMD patients and a very modest increase in BM in Mfge8(-/-) mice, our data suggests that MFGE8 dysfunction does not play a critical role in the pathogenesis of AMD.
Resumo:
Les évidences s'accumulent concernant des problèmes de corrosion touchant les prothèses à col modulaires. Plusieurs études récentes révèlent des taux d'ions métalliques élevés. Le but de cette étude était de comparer les taux d'ions métalliques (Co, Cr, Mo, Ti), dans le sérum, chez des porteurs de prothèses à col modulaire, à tige monobloc, ainsi que sans implant. Méthodes Nous avons recruté 60 patients, dont 50 porteurs d'une PTH, unilatérale, sans aucun autre implant, non-cimentée, avec tête en céramique, à minimum 1 année postopératoire. Quarante avaient une tige SPS (Symbios) (Ti6Al4 V) modulaire (col en CoCr) et 10 une SPS monobloc (non-modulaire). Les cupules étaient toutes en alliage de Ti (Ti6Al4 V) avec insert céramique ou PE. Nous avons constitué un groupe témoin sans aucun implant. Dans le groupe o modulaires O, le col a été choisi en préopératoire sur la base d'une planification 3D et assemblé à sec avant implantation. Nous avons prélevé un échantillon sérique, un autre sanguin, qui ont été analysés par spectrométrie de masse, permettant une détermination atomique quantitative. Le résultat clinique a été estimé à l'aide du o Oxford Hip Score O. Résultats Nous avons trouvé un Co sérique moyen à 1,54 Ig L dans le groupe O modulaires O et à 0,32 Ig L dans le groupe o monobloc O avec un p < 0,001. Pour le Cr, on a 1,12 Ig L (modulaires) vs 0,60 Ig L (monoblocs) avec un p < 0,001, pour le Ti 31 Ig L (modulaires) vs 22 Ig L (monoblocs) avec p < 0,001 et pour le Mo, 0,96 Ig L (modulaires) vs 0,74 (monoblocs) avec p = 0,254. Deux patients avaient des valeurs de Co supérieures à 7 Ig L et 11 étaient au-dessus de 1 Ig L, valeur considérée comme limite. Les valeurs dans le sang complet étaient similaires. Nous n'avons pas trouvé de différence significative selon les types de col modulaires (longs vs courts et rétro vs normaux). Curieusement, le taux de Cr était significativement plus élevé chez les patients sans aucun implant que chez les porteurs de SPS monobloc, par contre les différences n'étaient pas significatives pour les autres éléments. Conclusion Les taux sériques et sanguins de ions Co, Cr et Ti étaient significativement plus élevés dans le groupe des patients avec col modulaire, avec 2 valeurs 40 extrêmement hautes et plus de la moitié (11 40) anormalement hautes. Bien que ces valeurs soient inférieures à celles d'autres études, nous avons arrêter d'utiliser de tiges à cols modulaires, et avons initié un suivi annuel des patients porteurs, similaire à celui instauré pour les grosses têtes métal-métal.
Resumo:
Different formulations of trivalent oral poliomyelitis vaccine were tested, in order to obtain better thermostability, reduce corrosion of machinery and improve production costs. Magnesium chloride, sucrose, arginine and 199-Hank's medium were used in the formulations. The most appropriate formulation was a mixture of MgCl2 and arginine, which was highly thermostable, and had low production costs. The low corrosive formulation was rejected, due to low thermostability on storage.