885 resultados para Fiber reinforcement (E)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we proposed a relative humidity (RH) sensor based on a Bragg grating written in an optical fiber, associated with a coating of organo-silica hybrid material prepared by the sol-gel method. The organo-silica-based coating has a strong adhesion to the optical fiber and its expansion is reversibly affected by the change in the RH values (15.0-95.0%) of the surrounding environment, allowing an increased sensitivity (22.2 pm/%RH) and durability due to the presence of a siliceous-based inorganic component. The developed sensor was tested in a real structure health monitoring essay, in which the RH inside two concrete blocks with different porosity values was measured over 1 year. The results demonstrated the potential of the proposed optical sensor in the monitoring of civil engineering structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fluorometric technique based on a liquid drop excited from its interior by an optical fiber is described for the measurement of low concentrations of atmospheric hydrogen sulfide (H2S). A drop of alkaline fluorescein mercuric acetate (FMA) solution is suspended in a flowing air sample stream and serves as a renewable sensor. An optical fiber contained within the conduit that forms the drop, brings in the excitation beam; the fluorescence emission is measured by an inexpensive photodiode positioned close to the drop. As H2S in the sample is collected by the alkaline drop, it reacts rapidly with FMA resulting in a significant decrease in fluorescence intensity, proportional to the concentration of H2S sampled. The chemistry of this uniquely selective reaction has been well established for many years, the present technique permits a simple fast inexpensive near real-time measurement with very little reagent consumption. Even without prolonged sampling/preconcentration steps, limits of detection (LODs) in the double digit ppbv range is readily attainable. (C) 1997 Elsevier B.V. B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study addressed the effects of nandrolone decanoate (ND) on contractile properties and muscle fiber characteristics of rats submitted to swimming. Male Wistar rats were grouped in sedentary (S), swimming (Sw), sedentary+ND (SND), and swimming+ND (SwND), six animals per group. ND (3 mg/kg) was injected (subcutaneously) 5 days/week, for 4 weeks. Swimming consisted of 60-min sessions (load 2%), 5 days/week, for 4 weeks. After this period, the sciatic nerve extensor digitorum longus (EDL) muscle was isolated for myographic recordings. Fatigue resistance was assessed by the percent (%) decline of 180 direct tetanic contractions (30 Hz). Safety margin of synaptic transmission was determined from the resistance to the blockade of indirectly evoked twitches (0.5 Hz) induced by pancuronium (5 to 9 x 10(-7) M). EDL muscles were also submitted to histological and histochemical analysis (haematoxylin-eosin (HE); nicotinamide adenine dinucleotide-tetrazolium reductase (NADH-TR)). Significant differences were detected by two-way ANOVA (p<0.05). ND did not change body mass, fatigue resistance or kinetic properties of indirect twitches in either sedentary or swimming rats. In contrast, ND reduced the safety margin of synaptic transmission in sedentary animals (SND=53.3+/-4.7% vs. S=75.7+/-2.0%), but did not affect the safety margin in the swimming rats (SwND=75.81+/-3.1% vs. Sw=71.0+/-4.0%). No significant difference in fiber type proportions or diameters was observed in EDL muscle of any experimental group. These results indicate that ND does not act as an ergogenic reinforcement in rats submitted to 4 weeks of swimming. on the other hand, this study revealed an important toxic effect of ND, that it reduces the safety margin of synaptic transmission in sedentary animals. Such an effect is masked when associated with physical exercise. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As revealed by the NADH-diaphorase and myosine ATPase, the M. extensor carpi radialis longus of the rat possesses at least 3 main kinds of fibres, with different distribution on the superficial and deep portions of the muscle. The superficial portion revealed that 67.68 % are FG (fast-twitch-glycolytic) fibres, 14.72 % are FOG (fast-twitch-oxidative) fibres and 17.60 % are SO (slow-twitch-glycolytic) fibres. Already the deep portion revealed that 71.29 % are SO (slow-twitch-glycolytic) fibres, 17.46 % are FOG (fast-twitch-oxidative-glycolytic) fibres and 11.25 % are FG (fast-twitch-glycolytic) fibres. The miosine ATPase reaction was used to demonstrate contracting characteristics. These findings suggest that the movements of fast contraction of the M. extensor carpi radialis longus are predominant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of mechanical cycling on the bond strength of fiber posts bonded to root dentin. The hypotheses examined were that bond strength is not changed after fatigue testing and bond strength does not present vast variations according to the type of fiber post. Sixty crownless, single-rooted human teeth were endodontically treated, with the space prepared at 12 mm. Thirty specimens received a quartz fiber post (Q-FRC (DT Light-Post), and the remaining 30 specimens received a glass fiber post (G-FRC) (FRC Postec Plus). All the posts were resin luted (All Bond+Duolink), and each specimen was embedded in a cylinder with epoxy resin. The specimens were divided into six groups: G1-Q-FRC+no cycling, G2- Q-FRC+20,000 cycles (load: 50N, angle of 45 degrees; frequency: 8Hz); G3- Q-FRC+2,000,000 cycles; G4- G-FRC+no cycling; G5- G-FRC+20,000 cycles; G6- GFRC+2,000,000 cycles. The specimens were cut perpendicular to their long axis, forming 2-mm thick disc-samples, which were submitted to the push-out test. ANOVA (alpha=.05) revealed that: (a) QFRC (7.1 +/- 2.2MPa) and G-FRC (6.9 +/- 2.1MPa) were statistically similar (p=0.665); (b) the no cycling groups (7.0 +/- 2.4MPa), 20,000 cycles groups (7.0 +/- 2.1MPa) and 2,000,000 cycles groups (7.0 +/- 2.0MPa) were statistically similar (p=0.996). It concluded that mechanical cycling did not affect the bond strength of two fiber posts bonded to dentin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fiber types distribution in the diagastric muscle of tufted capuchin monkey was studied by means of NADH-TR, myosin-ATPase, after alkaline and acid preincubations and SDH histochemical reactions. Three different types of fibers were found presenting an equal distribution. The percentage and types of fibers were as follow: 18.2 % SO (Slow Oxydative), 38.4 % FOG (Fast Oxydative Glycolytic) and 43.4 % FG (Fast Glycolytic). FG fibers revealed the largest area. The relatively high concentration of fast twitch (81.2 %) seems to indicate this muscle is involved with the acceleration and fast speed of jaw movements. Aerobic metabolism represented by SO + FOG fibers (56.6 %) suggests that this muscle possesses an additional role than that related to the lowering of the jaw.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a combined stain for simultaneous demonstration of the preterminal axons and cholinesterase activity at myoneural junctions of mammalian muscles. This technique employs acetylthiocholine iodide as the substrate for cholinesterase activity and silver nitrate impregnation of preterminal axons. The procedure is rapid, simple and uses fresh muscles. Intramuscular nerves, preterminal axons and myoneural junctions are stained simultaneously brown or black with minimal background staining of connective tissue and muscle fibers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the influence of the cementation length of glass fiber-reinforced composite (FRC) on the fatigue resistance of bovine teeth restored with an adhesively cemented FRC. Thirty roots of single-rooted bovine teeth were allocated to 3 groups (n = 10), according to the ratio of crown length/root length (post cementation length): group 1 = 2/3, group 2 = 1/2, and group 3 = 1/1. The roots were prepared, the fiber posts (FRC Postec Plus) were cemented, and the specimens were submitted to 2 million mechanical cycles. After fatigue testing, a score was given based on the number of fatigue cycles until fracture, and data were submitted to statistical analysis. All specimens were resistant to fatigue. Taking into account the methodology and results of this study, the evaluated fiber posts can be cemented based on the ratio of crown/root at 1/1. Further clinical studies must be conducted to verify this ratio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, fibre-reinforced self-compacting concretes were developed for precast building components, incorporating either adherent metal fibres or polymeric synthetic slipping fibres or a combination of both. To achieve the warranted workability, compressive and splitting tensile strengths, compositions were determined by preliminary tests on self-compacting materials with various proportions of metal fibres. Bending tests in controlled deflection confirmed the positive contribution of fibres in the mechanical behaviour of self-compacting concrete. The comparison between vibrated and self-compacting concretes of similar mechanical characteristics indicated a possible better fibre-matrix bond in the case of self-compacting types. The results also showed that the properties of the hybrid fibre-reinforced self-compacting concrete could be inferred from the properties of the individual single-fibre reinforcements and their respective proportions through simple mix-rules.