975 resultados para Faecal Occult Blood test (FOBt)
Resumo:
"X48896"--Colophon.
Resumo:
The purpose of this investigation was to evaluate the impact of undertaking peripheral blood stem cell transplantation (PBST) on quality of life (QoL), and to determine the effect of participating in a mixed-type, moderate-intensity exercise program on QoL. It was also an objective to determine the relationship between peak aerobic capacity and QoL in PBST patients. QoL was assessed via the CARES questionnaire and peak aerobic capacity by a maximal graded treadmill test, pretransplant (PI), post transplant (PII) and following a 12-week intervention period (PIII). At PII, 12 patients were divided equally into a control or exercise intervention group. Undergoing a PBST was associated with a statistically but not clinically significant decline in QoL (P < 0.05). Following the intervention, exercising patients demonstrated an improved QoL when compared with pretransplant ratings (P < 0.01) and nonexercising transplant patients (P < 0.05). Moreover, peak aerobic capacity and QoL were correlated (P < 0.05). The findings demonstrated that exercise participation following oncology treatment is associated with a reduction in the number and severity of endorsed problems, which in turn leads to improvements in global, physical and psychosocial QoL. Furthermore, a relationship between fitness and QoL exists, with those experiencing higher levels of fitness also demonstrating higher QoL.
Resumo:
The aim of this study was to assess the sensitivity and specificity of catheter-drawn and peripheral blood cultures. Paired blood culture samples collected over a 44-month period from a 280 bed Brisbane metropolitan hospital were analysed, using standard clinical and microbiological criteria, to determine whether blood culture isolates represented true bacteraemias or contamination. Catheter-collected cultures had a specificity of 85% compared with 97% for peripheral cultures. In only two instances (0.2%) was the diagnosis of clinically significant bacteraemia made on the basis of catheter culture alone. This study concluded that catheter-collected samples are not a good test for true bacteraemia, and that peripheral. cultures are more reliable when the results of the paired cultures are discordant. (c) 2004 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.
Resumo:
We investigated the capacity of two reptiles, an agamid lizard Pogona barbata and a chelid turtle Emydura signata, to compensate for the effects of temperature by making changes in their whole blood respiratory properties. This was accomplished by measuring the P-50 (at 10, 20 and 30 degrees C), hematocrit (Hct), haemoglobin concentration ([Hb]) and mean cell haemoglobin concentration (MCHC) in field acclimatised and laboratory acclimated individuals. The acute effect of temperature on P50 in P barbata, expressed as heat of oxygenation (Delta H), ranged from -16.8 +/- 1.84 to -28.5 +/- 2.73 kJ/mole. P-50 of field acclimatised P barbata increased significantly from early spring to summer at the test temperatures of 20 degrees C (43.1 +/- 1.2 to 48.8 +/- 2.1 mmHg) and 30 degrees C (54.7 +/- 1.2 to 65.2 +/- 2.3 mmHg), but showed no acclimation under laboratory conditions. For E. signata, Delta H ranged from -31.1 +/- 6.32 to -48.2 +/- 3.59 kJ/mole. Field acclimatisation and laboratory acclimation of P-50 did not occur. However, in E. signata, there was a significant increase in [Hb] and MCHC from early spring to summer in turtles collected from the wild (1.0 +/- 0.1 to 1.7 +/- 0.2 mmol/L and 4.0 +/- 0.3 to 6.7 +/- 0.7 mmol/L, respectively). (C) 2005 Published by Elsevier Inc.
Resumo:
OBJECTIVE - We examined the associations of physical activity with fasting plasma glucose (FPG) and with 2-h postload plasma glucose (2-h PG) in men and women with low, moderate, and high waist circumference. RESEARCH DESIGN AND METHODS - The Australian Diabetes, Obesity and Lifestyle (AusDiab) study provided data on a population-based cross-sectional sample of 4,108 men and 5,106 women aged >= 25 years without known diabetes or health conditions that could affect physical activity. FPG and 2-h PG were obtained from an oral glucose tolerance test. Self-reported physical activity level was defined according to the current public health guidelines as active (>= 150 min/week across five or more sessions) or inactive (< 150 min/week and/or less than five sessions). Sex-specific quintiles of physical activity time were used to ascertain dose response. RESULTS - Being physically active and total physical activity time were independently and negatively associated with 2-h PG. When physical activity level was considered within each waist circumference category, 2-h PG was significantly lower in active high-waist circumference women (beta-0.30 [95% CI -0.59 to -0.01], P = 0.044) and active low-waist circumference men(beta-0.25 [-0.49 to -0.02],P = 0.036) compared with their inactive counterparts. Considered across physical activity and waist circumference categories, 2-h PG levels were not significantly different between active moderate-waist circumference participants and active low-waist circumference participants. Associations between physical activity and FPG were nonsignificant. CONCLUSIONS - There are important differences between 2-h PG and FPG related to physical activity. It appears that 2-h PG is more sensitive to the beneficial effects of physical activity, and these benefits occur across the waist circumference spectrum.
Resumo:
Posttransplantation diabetes (PTD) contributes to cardiovascular disease and graft loss in renal transplant recipients (RTR). Current recommendations advise fasting blood glucose (FBG) as the screening and diagnostic test of choice for PTD. This study sought to determine (1) the predictive power of FBG with respect to 2-h blood glucose (2HBG) and (2) the prevalence of PTD using FBG and 2HBG compared with that using FBG alone, in prevalent RTR. A total of 200 RTR (mean age 52 yr; 59% male; median transplant duration 6.6 yr) who were >6 mo posttransplantation and had no known history of diabetes were studied. Patients with FBG
Resumo:
Exercise brachial blood pressure ( BP) predicts mortality, but because of wave reflection, central ( ascending aortic) pressure differs from brachial pressure. Exercise central BP may be clinically important, and a noninvasive means to derive it would be useful. The purpose of this study was to test the validity of a noninvasive technique to derive exercise central BP. Ascending aortic pressure waveforms were recorded using a micromanometer-tipped 6F Millar catheter in 30 patients (56 +/- 9 years; 21 men) undergoing diagnostic coronary angiography. Simultaneous recordings of the derived central pressure waveform were acquired using servocontrolled radial tonometry at rest and during supine cycling. Pulse wave analysis of the direct and derived pressure signals was performed offline (SphygmoCor 7.01). From rest to exercise, mean arterial pressure and heart rate were increased by 20 +/- 10 mm Hg and 15 +/- 7 bpm, respectively, and central systolic BP ranged from 77 to 229 mm Hg. There was good agreement and high correlation between invasive and noninvasive techniques with a mean difference (+/- SD) for central systolic BP of -1.3 +/- 3.2 mm Hg at rest and -4.7 +/- 3.3 mm Hg at peak exercise ( for both r=0.995; P < 0.001). Conversely, systolic BP was significantly higher peripherally than centrally at rest (155 +/- 33 versus 138 +/- 32mm Hg; mean difference, -16.3 +/- 9.4mm Hg) and during exercise (180 +/- 34 versus 164 +/- 33 mm Hg; mean difference, -15.5 +/- 10.4 mm Hg; for both P < 0.001). True myocardial afterload is not reliably estimated by peripheral systolic BP. Radial tonometry and pulse wave analysis is an accurate technique for the noninvasive determination of central BP at rest and during exercise.
Resumo:
In emergency situations, where time for blood transfusion is reduced, the O negative blood type (the universal donor) is administrated. However, sometimes even the universal donor can cause transfusion reactions that can be fatal to the patient. As commercial systems do not allow fast results and are not suitable for emergency situations, this paper presents the steps considered for the development and validation of a prototype, able to determine blood type compatibilities, even in emergency situations. Thus it is possible, using the developed system, to administer a compatible blood type, since the first blood unit transfused. In order to increase the system’s reliability, this prototype uses different approaches to classify blood types, the first of which is based on Decision Trees and the second one based on support vector machines. The features used to evaluate these classifiers are the standard deviation values, histogram, Histogram of Oriented Gradients and fast Fourier transform, computed on different regions of interest. The main characteristics of the presented prototype are small size, lightweight, easy transportation, ease of use, fast results, high reliability and low cost. These features are perfectly suited for emergency scenarios, where the prototype is expected to be used.
Resumo:
The blood types determination is essential to perform safe blood transfusions. In emergency situations isadministrated the “universal donor” blood type. However, sometimes, this blood type can cause incom-patibilities in the transfusion receptor. A mechatronic prototype was developed to solve this problem.The prototype was built to meet specific goals, incorporating all the necessary components. The obtainedsolution is close to the final system that will be produced later, at industrial scale, as a medical device.The prototype is a portable and low cost device, and can be used in remote locations. A computer appli-cation, previously developed is used to operate with the developed mechatronic prototype, and obtainautomatically test results. It allows image acquisition, processing and analysis, based on Computer Visionalgorithms, Machine Learning algorithms and deterministic algorithms. The Machine Learning algorithmsenable the classification of occurrence, or alack of agglutination in the mixture (blood/reagents), and amore reliable and a safer methodology as test data are stored in a database. The work developed allowsthe administration of a compatible blood type in emergency situations, avoiding the discontinuity of the“universal donor” blood type stocks, and reducing the occurrence of human errors in the transfusion practice.
Resumo:
The purpose of this investigation was to design a novel magnetic drive and bearing system for a new centrifugal rotary blood pump (CRBP). The drive system consists of two components: (i) permanent magnets within the impeller of the CRBP; and (ii) the driving electromagnets. Orientation of the magnets varies from axial through to 60° included out-lean (conical configuration). Permanent magnets replace the electromagnet drive to allow easier characterization. The performance characteristics tested were the axial force of attraction between the stator and rotor at angles of rotational alignment, Ø, and the corresponding torque at those angles. The drive components were tested for various magnetic cone angles, ?. The test was repeated for three backing conditions: (i) non-backed; (ii) steel-cupped; and (iii) steel plate back-iron, performed on an Instron tensile testing machine. Experimental results were expanded upon through finite element and boundary element analysis (BEM). The force/torque characteristics were maximal for a 12-magnet configuration at 0° cone angle with steel-back iron (axial force = 60 N, torque = 0.375 Nm). BEM showed how introducing a cone angle increases the radial restoring force threefold while not compromising axial bearing force. Magnets in the drive system may be orientated not only to provide adequate coupling to drive the CRBP, but to provide significant axial and radial bearing forces capable of withstanding over 100 m/s2 shock excitation on the impeller. Although the 12 magnet 0° (?) configuration yielded the greatest force/torque characteristic, this was seen as potentially unattractive as this magnetic cone angle yielded poor radial restoring force characteristics.
Resumo:
PURPOSE: Breast cancer resistance protein (BCRP/ABCG2) is a drug efflux transporter expressed at the blood cerebrospinal fluid barrier (BCSFB), and influences distribution of drugs into the central nervous systems (CNS). Current inhibitors have failed clinically due to neurotoxicity. Novel approaches are needed to identify new modulators to enhance CNS delivery. This study examines 18 compounds (mainly phytoestrogens) as modulators of the expression/function of BCRP in an in vitro rat choroid plexus BCSFB model. METHODS: Modulators were initially subject to cytotoxicity (MTT) assessment to determine optimal non-toxic concentrations. Reverse-transcriptase PCR and confocal microscopy were used to identify the presence of BCRP in Z310 cells. Thereafter modulation of the intracellular accumulation of the fluorescent BCRP probe substrate Hoechst 33342 (H33342), changes in protein expression of BCRP (western blotting) and the functional activity of BCRP (membrane insert model) were assessed under modulator exposure. RESULTS: A 24 hour cytotoxicity assay (0.001 µM-1000 µM) demonstrated the majority of modulators possessed a cellular viability IC50 > 148 µM. Intracellular accumulation of H33342 was significantly increased in the presence of the known BCRP inhibitor Ko143 and, following a 24 hour pre-incubation, all modulators demonstrated statistically significant increases in H33342 accumulation (P < 0.001), when compared to control and Ko143. After a 24 hour pre-incubation with modulators alone, a 0.16-2.5-fold change in BCRP expression was observed for test compounds. The functional consequences of this were confirmed in a permeable insert model of the BCSFB which demonstrated that 17-β-estradiol, naringin and silymarin (down-regulators) and baicalin (up-regulator) can modulate BCRP-mediated transport function at the BCSFB. CONCLUSION: We have successfully confirmed the gene and protein expression of BCRP in Z310 cells and demonstrated the potential for phytoestrogen modulators to influence the functionality of BCRP at the BCSFB and thereby potentially allowing manipulation of CNS drug disposition.
Resumo:
Purpose: To test the hypothesis of a significant relationship between systemic markers of renal and vascular function (processes linked to cardiovascular disease and its development) and retinal microvascular function in diabetes and/or cardiovascular disease.Methods: Ocular microcirculatory function was measured in 116 patients with diabetes and/or cardiovascular disease using static and continuous retinal vessel responses to three cycles of flickering light. Endothelial function was evaluated by von Willebrand factor (vWf), endothelial microparticles and soluble E selectin, renal function by serum creatinine, creatinine clearance and estimated glomerular filtration rate (eGFR). HbA1c was used as a control index.Results: Central retinal vein equivalence and venous maximum dilation to flicker were linked to HbA1c (both p<0.05). Arterial reaction time was linked to serum creatinine (p=0.036) and eGFR (p=0.039), venous reaction time was linked to creatinine clearance (p=0.018). Creatinine clearance and eGFR were linked to arterial maximum dilatation (p<0.001 and p=0.003 respectively) and the dilatation amplitude (p=0.038 and p=0.048 respectively) responses in the third flicker cycle. Of venous responses to the first flicker cycle, HbA1c was linked to the maximum dilation response (p=0.004) and dilatation amplitude (p=0.017), vWf was linked to the maximum constriction response (p=0.016), and creatinine clearance to the baseline diameter fluctuation (p=0.029). In the second flicker cycle, dilatation amplitude was linked to serum creatinine (p=0.022). Conclusions: Several retinal blood vessel responses to flickering light are linked to glycaemia and renal function, but only one index is linked to endothelial function. Renal function must be considered when interpreting retinal vessel responses.
Resumo:
Studies have shown that the environmental conditions of the home are important predictors of health, especially in low-income communities. Understanding the relationship between the environment and health is crucial in the management of certain diseases. One health outcome related to the home environment among urban, minority, and low-income children is childhood lead poisoning. The most common sources of lead exposure for children are lead paint in older, dilapidated housing and contaminated dust and soil produced by accumulated residue of leaded gasoline. Blood lead levels (BLL) as low as 10 μg/dL in children are associated with impaired cognitive function, behavior difficulties, and reduced intelligence. Recently, it is suggested that the standard for intervention be lowered to BLL of 5 μg /dl. The objectives of our report were to assess the prevalence of lead poisoning among children under six years of age and to quantify and test the correlations between BLL in children and lead exposure levels in their environment. This cross-sectional analysis was restricted to 75 children under six years of age who lived in 6 zip code areas of inner city Miami. These locations exhibited unacceptably high levels of lead dust and soil in areas where children live and play. Using the 5 μg/dL as the cutoff point, the prevalence of lead poisoning among the study sample was 13.33%. The study revealed that lead levels in floor dust and window sill samples were positively and significantly correlated with BLL among children (p < 0.05). However, the correlations between BLL and the soil, air, and water samples were not significant. Based on this pilot study, a more comprehensive environmental study in surrounding inner city areas is warranted. Parental education on proper housecleaning techniques may also benefit those living in the high lead-exposed communities of inner city Miami.
Resumo:
Oxygen equilibrium curves have been widely used to understand oxygen transport in numerous organisms. A major challenge has been to monitor oxygen binding characteristics and concomitant pH changes as they occur in vivo, in limited sample volumes. Here we report a technique allowing highly resolved and simultaneous monitoring of pH and blood pigment saturation in minute blood volumes. We equipped a gas diffusion chamber with a broad range fibre optic spectrophotometer and a micro-pH optode and recorded changes of pigment oxygenation along PO2 and pH gradients to test the setup. Oxygen binding parameters derived from measurements in only 15 µl of haemolymph from the cephalopod Octopus vulgaris showed low instrumental error (0.93%) and good agreement with published data. Broad range spectra, each resolving 2048 data points, provided detailed insight into the complex absorbance characteristics of diverse blood types. After consideration of photobleaching and intrinsic fluorescence, pH optodes yielded accurate recordings and resolved a sigmoidal shift of 0.03 pH units in response to changing PO2 from 0-21 kPa. Highly resolved continuous recordings along pH gradients conformed to stepwise measurements at low rates of pH changes. In this study we showed that a diffusion chamber upgraded with a broad range spectrophotometer and an optical pH sensor accurately characterizes oxygen binding with minimal sample consumption and manipulation. We conclude that the modified diffusion chamber is highly suitable for experimental biologists who demand high flexibility, detailed insight into oxygen binding as well as experimental and biological accuracy combined in a single set up.