854 resultados para Electronic equipment
Resumo:
The use of electronic control devices has expanded worldwide during the last few years, the most widely used model being the Taser. However, the scientific knowledge about electronic control devices remains limited. We reviewed the medical literature to examine the potential implications of electronic devices in terms of morbidity and mortality, and to identify and evaluate all the existing experimental human studies. A single exposure of an electronic control device on healthy individuals can be assumed to be generally safe, according to 23 prospective human experimental studies and numerous volunteer exposures. In case series, however, electronic control devices could have deleterious effects when used in the field, in particular if persons receive multiple exposures, are intoxicated, show signs of "excited delirium," or present with medical comorbidities. As the use of electronic control devices continues to increase, the controversy about its safety, notably in potentially high-risk individuals, is still a matter of debate. The complications of electronic control device exposure are numerous but often recognizable, usually resulting from barbed dart injuries or from falls. Persons exposed to electronic control devices should therefore be fully examined, and traumatic lesions must be ruled out.
Resumo:
BACKGROUND: Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. METHODS: Testing was done for seven home ventilators on a bench model adapted to simulate NIV and generate unintentional leaks (ie, other than of the mask exhalation valve). Five levels of leaks were simulated using a computer-driven solenoid valve (0-60 L/min) at different levels of inspiratory pressure (15 and 25 cm H(2)O) and at a fixed expiratory pressure (5 cm H(2)O), for a total of 10 conditions. Bench data were compared with results retrieved from ventilator software for leaks and Vt. RESULTS: For assessing leaks, three of the devices tested were highly reliable, with a small bias (0.3-0.9 L/min), narrow limits of agreement (LA), and high correlations (R(2), 0.993-0.997) when comparing ventilator software and bench results; conversely, for four ventilators, bias ranged from -6.0 L/min to -25.9 L/min, exceeding -10 L/min for two devices, with wide LA and lower correlations (R(2), 0.70-0.98). Bias for leaks increased markedly with the importance of leaks in three devices. Vt was underestimated by all devices, and bias (range, 66-236 mL) increased with higher insufflation pressures. Only two devices had a bias < 100 mL, with all testing conditions considered. CONCLUSIONS: Physicians monitoring patients who use home ventilation must be aware of differences in the estimation of leaks and Vt by ventilator software. Also, leaks are reported in different ways according to the device used.
Resumo:
This piece of work which is Identification of Research Portfolio for Development of Filtration Equipment aims at presenting a novel approach to identify promising research topics in the field of design and development of filtration equipment and processes. The projected approach consists of identifying technological problems often encountered in filtration processes. The sources of information for the problem retrieval were patent documents and scientific papers that discussed filtration equipments and processes. The problem identification method adopted in this work focussed on the semantic nature of a sentence in order to generate series of subject-action-object structures. This was achieved with software called Knowledgist. List of problems often encountered in filtration processes that have been mentioned in patent documents and scientific papers were generated. These problems were carefully studied and categorized. Suggestions were made on the various classes of these problems that need further investigation in order to propose a research portfolio. The uses and importance of other methods of information retrieval were also highlighted in this work.
Resumo:
Työn tavoitteena oli tutkia hyvän asiakasreferenssin ominaisuuksia suodatinvalmistaja Laroxin myynnin ja huollon sekä yrityksen asiakkaiden näkökulmasta. Larox voi käyttää saatua tietoa referenssien tehokkaampaan valintaan ja hyödyntämiseen. Kaksi internet-kyselyä toteutettiin, välineenä Webropol. Alustava kysely sunnattiin Laroxin myynnille ja huollolle. Kysely koostui viidestä kategoriasta asiakasreferenssejä, joiden tärkeyttä arvioitiin, sekä vapaista vastauksista. Tunnistettuja hyvän asiakasreferenssin ominaisuuksia ovat hyvä suhde referenssiasiakkaaseen, positiiviset jarehelliset suosittelut asiakkaalta, referenssilaitteen hyvä toimintakyky ja asiakas joka ymmärtää huollon tärkeyden. Pääkysely suunnattiin Laroxin asiakkaille. Tilastollisilla analyyseilla tutkittiin koetun riskin mallinmuuttujien välisiä yhteyksiä. Analyysit eivät paljastaneet merkittäviä riippuvuuksia asiakasreferenssin ominaisuuksien tärkeydessä eritaustaisten vastaajien tai tilannetekijöiden välillä, mutta asiakasreferenssin ominaisuuksien faktorit tukevat mallia. Referenssilaitteiden toimintakyky vaikuttaa tärkeimmältä ja huollon tärkeys on myös merkittävä.
Resumo:
Tämän diplomityön tarkoituksena oli selvittää tekijät, jotka vaikuttavat verkkolaskutuksen leviämiseen yrityksissä sekä selvittää verkkolaskutuksen levinneisyys Etelä-Karjalassa. Erityisesti haluttiin selvittää tekijät, jotka hidastavat diffuusiota. Työn teoreettinen osuus esittelee lyhyesti diffuusionkäsitettä; pääpaino on kirjallisuudesta löytyvillä innovaatioiden omaksumiseen vaikuttavilla tekijöillä. Teorian pohjalta muodostettiin 16 hypoteesia, jotka testattiin empiirisessä osassa. Empiirinen aineisto kerättiin eteläkarjalaisilta pk-yrityksiltä postikyselyn avulla. Vastanneet yritykset jaettiin verkkolaskutuksen omaksuneisiin ja ei-omaksuneisiin yrityksiin. Vastanneista yrityksistä 7.5 % käytti verkkolaskutusta. 17.8 % vasta testasi verkkolaskujen lähetystä ja/tai vastaanottamista. Näin ollen 25.3 % yrityksistä oli verkkolaskuominaisuudet tietojärjestelmissään. Suurin osa vastaajista ei ollut tehnyt päätöstä verkkolaskutukseen siirtymisen suhteen. Seitsemän hypoteesia jäi voimaan ja yhdeksän hylättiin.Hypoteesien ulkopuolelta löydettiin lisäksi kaksi tärkeää tekijää, joilla on mahdollisesti vaikutusta verkkolaskutuksen omaksumiseen yrityksissä. Yritykset kokivat, että suurempi painostus yrityksen ulkopuolelta nopeuttaisi penetraatiota, ja toisaalta verkkolaskutusta koskevan informaation määrä on koettu liian alhaiseksi. Työn lopussa esitellään toimenpide-ehdotuksia verkkolaskutuksen leviämisennopeuttamiseksi.
Resumo:
Container Handling Equipment Monitoring System (CHEMS) is a system developed by Savcor One Oy. CHEMS measures important information for container ports performance and produces performance indicators. The aim of this thesis was to clarify performance measurement contents to Savcor and to develop, as an example, performance measures to Steveco Oy's container operations. The theoretical part of the thesis clarifies performance measurement and which of its components are important to container port. Performance measurement and measures are presented from the operational level's point of view, in which CHEMS is planned to aim. The theory of development process of performance measures is introduced at the end of the theoretical part. To make sure that performance measures are efficiently used, Steveco Oy's performance measures are developed in cooperation with the users. The measurement in operational level is continuous and the results must be reacted asquickly as possible. CHEMS is very suitable to continuous measurement and to produce real time-measures of container operations which are hard to get any otherway.
Resumo:
Every medical practitioner is confronted on a daily basis with emergencies. Among these, life-threatening emergencies can have disastrous consequences in term of morbidity and mortality; 22 cardiac arrests and 10 deaths were reported among the 1,650 Swiss practices during a 5 year period. The occurrence of life-threatening emergencies at the office necessitates, according to the type and place of the practice, the skills of the practitioner and the organization of his practice, the implementation of procedures, equipments (for example room equipped with a defibrillator, respiratory nebulizer, splints, emergency drugs) and specific continuous education programs that should be encouraged and made available to the whole medical corporation.
Resumo:
Tämän diplomityön tavoitteena on muodostaa sähköinen liiketoimintamalli kansainvälisen ohjelmistoyrityksen tarpeisiin. Ohjelmiston uusi ominaisuus antaa kolmansille osapuolille mahdollisuuden määritellä itse rakennusmallintamisessa tarvittavia komponentteja, mikä luo mahdollisuuden uuteen liiketoimintaan. Liiketoimintamallien teoria ja asiantuntijoiden haastattelut tulevat osoittamaan, että paras ratkaisu tässä tapauksessa on portaali, joka rakentuu komponenttimarkkinoista, e-kaupasta ja virtuaaliyhteisöstä. Komponenttimarkkinat on jaettu vapaaseen vaihdantaan ja sertifioitujen kehittäjien kaupankäyntiin. Tämä tarjoaa mahdollisuuksia kehittäjille valita sitoutuneisuutensa taso, samoin kuin motivoi heitä osallistumaan. E-kauppa on suunniteltu sovelluksille ja monimutkaisemmille komponenteille. Virtuaaliyhteisön kautta käyttäjät voivat keskustella mielipiteistään ja saada tukea ohjelmiston käyttämiseen sekä komponenttien kehittämiseen.
Resumo:
Posaconazole (POS) is a new antifungal agent for prevention and therapy of mycoses in immunocompromised patients. Variable POS pharmacokinetics after oral dosing may influence efficacy: a trough threshold of 0.5 ?g/ml has been recently proposed. Measurement of POS plasma concentrations by complex chromatographic techniques may thus contribute to optimize prevention and management of life-threatening infections. No microbiological analytical method is available. The objective of this study was to develop and validate a new simplified ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method and a sensitive bioassay for quantification of POS over the clinical plasma concentration range. The UPLC-MS/MS equipment consisted of a triple quadrupole mass spectrometer, an electrospray ionization (ESI) source, and a C(18) analytical column. The Candida albicans POS-hypersusceptible mutant (MIC of 0.002 ?g/ml) ?cdr1 ?cdr2 ?flu ?mdr1 ?can constructed by targeted deletion of multidrug efflux transporters and calcineurin genes was used for the bioassay. POS was extracted from plasma by protein precipitation with acetonitrile-methanol (75%/25%, vol/vol). Reproducible standard curves were obtained over the range 0.014 to 12 (UPLC-MS/MS) and 0.028 to 12 ?g/ml (bioassay). Intra- and interrun accuracy levels were 106% ± 2% and 103% ± 4% for UPLC-MS/MS and 102% ± 8% and 104% ± 1% for bioassay, respectively. The intra- and interrun coefficients of variation were 7% ± 4% and 7% ± 3% for UPLC-MS/MS and 5% ± 3% and 4% ± 2% for bioassay, respectively. An excellent correlation between POS plasma concentrations measured by UPLC-MS/MS and bioassay was found (concordance, 0.96). In 26 hemato-oncological patients receiving oral POS, 27/69 (39%) trough plasma concentrations were lower than 0.5 ?g/ml. The UPLC-MS/MS method and sensitive bioassay offer alternative tools for accurate and precise quantification of the plasma concentrations in patients receiving oral posaconazole.
Resumo:
Tehoelektoniikkalaitteella tarkoitetaan ohjaus- ja säätöjärjestelmää, jolla sähköä muokataan saatavilla olevasta muodosta haluttuun uuteen muotoon ja samalla hallitaan sähköisen tehon virtausta lähteestä käyttökohteeseen. Tämä siis eroaa signaalielektroniikasta, jossa sähköllä tyypillisesti siirretään tietoa hyödyntäen eri tiloja. Tehoelektroniikkalaitteita vertailtaessa katsotaan yleensä niiden luotettavuutta, kokoa, tehokkuutta, säätötarkkuutta ja tietysti hintaa. Tyypillisiä tehoelektroniikkalaitteita ovat taajuudenmuuttajat, UPS (Uninterruptible Power Supply) -laitteet, hitsauskoneet, induktiokuumentimet sekä erilaiset teholähteet. Perinteisesti näiden laitteiden ohjaus toteutetaan käyttäen mikroprosessoreja, ASIC- (Application Specific Integrated Circuit) tai IC (Intergrated Circuit) -piirejä sekä analogisia säätimiä. Tässä tutkimuksessa on analysoitu FPGA (Field Programmable Gate Array) -piirien soveltuvuutta tehoelektroniikan ohjaukseen. FPGA-piirien rakenne muodostuu erilaisista loogisista elementeistä ja niiden välisistä yhdysjohdoista.Loogiset elementit ovat porttipiirejä ja kiikkuja. Yhdysjohdot ja loogiset elementit ovat piirissä kiinteitä eikä koostumusta tai lukumäärää voi jälkikäteen muuttaa. Ohjelmoitavuus syntyy elementtien välisistä liitännöistä. Piirissä on lukuisia, jopa miljoonia kytkimiä, joiden asento voidaan asettaa. Siten piirin peruselementeistä voidaan muodostaa lukematon määrä erilaisia toiminnallisia kokonaisuuksia. FPGA-piirejä on pitkään käytetty kommunikointialan tuotteissa ja siksi niiden kehitys on viime vuosina ollut nopeaa. Samalla hinnat ovat pudonneet. Tästä johtuen FPGA-piiristä on tullut kiinnostava vaihtoehto myös tehoelektroniikkalaitteiden ohjaukseen. Väitöstyössä FPGA-piirien käytön soveltuvuutta on tutkittu käyttäen kahta vaativaa ja erilaista käytännön tehoelektroniikkalaitetta: taajuudenmuuttajaa ja hitsauskonetta. Molempiin testikohteisiin rakennettiin alan suomalaisten teollisuusyritysten kanssa soveltuvat prototyypit,joiden ohjauselektroniikka muutettiin FPGA-pohjaiseksi. Lisäksi kehitettiin tätä uutta tekniikkaa hyödyntävät uudentyyppiset ohjausmenetelmät. Prototyyppien toimivuutta verrattiin vastaaviin perinteisillä menetelmillä ohjattuihin kaupallisiin tuotteisiin ja havaittiin FPGA-piirien mahdollistaman rinnakkaisen laskennantuomat edut molempien tehoelektroniikkalaitteiden toimivuudessa. Työssä on myösesitetty uusia menetelmiä ja työkaluja FPGA-pohjaisen säätöjärjestelmän kehitykseen ja testaukseen. Esitetyillä menetelmillä tuotteiden kehitys saadaan mahdollisimman nopeaksi ja tehokkaaksi. Lisäksi työssä on kehitetty FPGA:n sisäinen ohjaus- ja kommunikointiväylärakenne, joka palvelee tehoelektroniikkalaitteiden ohjaussovelluksia. Uusi kommunikointirakenne edistää lisäksi jo tehtyjen osajärjestelmien uudelleen käytettävyyttä tulevissa sovelluksissa ja tuotesukupolvissa.
Resumo:
Digital services require personal information for a variety of reasons. Due to advances in communication technology, new types of services are evolving alongwith traditional Internet services. Due to the diversity of services, the traditional approaches to personal information handling designed for Internet services are inadequate. Therefore, new approaches are necessary. In this thesis, a solution where personal information is stored in and accessed from the user's mobile device is presented. This approach is called Mobile Electronic Personality (ME). The ME approach is compared to the existing approaches which rely on a database either at a service, a trusted third party or a client program. Various personal information properties are taken into account in the comparison of storage locations. The thesis presents both the internal and the communication architecture of the ME. The internal architecture defines how the information is stored in the mobile device. The communication architecture defines how the information can be accessed by different types of services from the ME. The use of the architecture is described for services in different environments. A simple ME based solution for the authentication of a user is defined. The authentication of service, which is required to protect the privacy of the users is also presented.
Resumo:
In this thesis the membrane filtration equipment for plate type ceramic membranes was developed based on filtration results achieved with different kinds of wastewaters. The experiments were mainly made with pulp and board mill wastewaters, but some experiments were also made with a bore well water and a stone cutting mine wastewater. The ceramicmembranes used were alpha-alumina membranes with a pore size of 100 nm. Some ofthe membranes were coated with a gamma-alumina layer to reduce the membrane pore size to 10 nm, and some of them were modified with different metal oxides in order to change the surface properties of the membranes. The effects of operationparameters, such as cross-flow velocity, filtration pressure and backflushing on filtration performance were studied. The measured parameters were the permeateflux, the quality of the permeate, as well as the fouling tendency of the membrane. A dynamic membrane or a cake layer forming on top of the membrane was observed to decrease the flux and increase separa-tion of certain substances, especially at low cross-flow velocities. When the cross-flow velocities were increased the membrane properties became more important. Backflushing could also be used to decrease the thickness of the cake layer and thus it improved the permeate flux. However, backflushing can lead to a reduction of retentions in cases where the cake layer is improving them. The wastewater quality was important for the thickness of the dynamic membrane and the membrane pore size influenced the permeate flux. In general, the optimization of operation conditions is very important for the successful operation of a membrane filtration system. The filtration equipment with a reasonable range of operational conditions is necessary, especiallywhen different kinds of wastewaters are treated. This should be taken into account already in the development stage of a filtration equipment.
Resumo:
The main goal of our study was to see whether an artificial olfactory system can be used as a nondestructive instrument to measure fruit maturity. In order to make an objective comparison, samples measured with our electronic nose prototype were later characterized using fruit quality techniques. The cultivars chosen for the study were peaches, nectarines, apples, and pears. With peaches and nectarines, a PCA analysis on the electronic nose measurements helped to guess optimal harvest dates that were in good agreement with the ones obtained with fruit quality techniques. A good correlation between sensor signals and some fruit quality indicators was also found. With pears, the study addressed the possibility of classifying samples regarding their ripeness state after different cold storage and shelf-life periods. A PCA analysis showed good separation between samples measured after a shelf-life period of seven days and samples with four or less days. Finally, the electronic nose monitored the shelf-life ripening of apples. A good correlation between electronic nose signals and firmness, starch index, and acidity parameters was found. These results prove that electronic noses have the potential of becoming a reliable instrument to assess fruit ripeness.
Resumo:
This work proposes the creation of a bioinspired electronic white cane for blind people using the whiskers principle for short-range navigation and exploration. Whiskers are coarse hairs of an animal's face that tells the animal that it has touched something using the nerves of the skin. In this work the raw data acquired from a low-size terrestrial LIDAR and a tri-axial accelerometer is converted into tactile information using several electromagnetic devices configured as a tactile belt. The LIDAR and the accelerometer are attached to the user’s forearm and connected with a wire to the control unit placed on the belt. Early validation experiments carried out in the laboratory are promising in terms of usability and description of the environment.
Resumo:
Canopy characterization is a key factor to improve pesticide application methods in tree crops and vineyards. Development of quick, easy and efficient methods to determine the fundamental parameters used to characterize canopy structure is thus an important need. In this research the use of ultrasonic and LIDAR sensors have been compared with the traditional manual and destructive canopy measurement procedure. For both methods the values of key parameters such as crop height, crop width, crop volume or leaf area have been compared. Obtained results indicate that an ultrasonic sensor is an appropriate tool to determine the average canopy characteristics, while a LIDAR sensor provides more accuracy and detailed information about the canopy. Good correlations have been obtained between crop volume (CVU) values measured with ultrasonic sensors and leaf area index, LAI (R2 = 0.51). A good correlation has also been obtained between the canopy volume measured with ultrasonic and LIDAR sensors (R2 = 0.52). Laser measurements of crop height (CHL) allow one to accurately predict the canopy volume. The proposed new technologies seems very appropriate as complementary tools to improve the efficiency of pesticide applications, although further improvements are still needed.