842 resultados para Electrode position
Resumo:
The development and application of a functionalized carbon nanotubes paste electrode (CNPE) modified with crosslinked chitosan for determination of Cu(II) in industrial wastewater, natural water and human urine samples by linear scan anodic stripping voltammetry (LSASV) are described. Different electrodes were constructed using chitosan and chitosan crosslinked with glutaraldehyde (CTS-GA) and epichlorohydrin (CTS-ECH). The best voltammetric response for Cu(II) was obtained with a paste composition of 65% (m/m) of functionalized carbon nanotubes, 15% (m/m) of CTS-ECH, and 20% (m/m) of mineral oil using a solution of 0.05 mol L(-1) KNO(3) with pH adjusted to 2.25 with HNO(3), an accumulation potential of 0.3V vs. Ag/AgCl (3.0 mol L(-1) KCl) for 300 s and a scan rate of 100 mV s(-1). Under these optimal experimental conditions, the voltammetric response was linearly dependent on the Cu(II) concentration in the range from 7.90 x 10(-8) to 1.60 x 10(-5) mol L(-1) with a detection limit of 1.00 x 10(-8) mol L(-1). The samples analyses were evaluated using the proposed sensor and a good recovery of Cu(II) was obtained with results in the range from 98.0% to 104%. The analysis of industrial wastewater, natural water and human urine samples obtained using the proposed CNPE modified with CTS-ECH electrode and those obtained using a comparative method are in agreement at the 95% confidence level. (C) 2009 Elsevier B. V. All rights reserved.
Resumo:
The modification of a gold electrode surface by electropolymerization of trans-[Ru(NH(3))(4)(Ist)SO(4)](+) to produce an electrochemical sensor for nitric oxide was investigated. The influence of dopamine, serotonin and nitrite as interferents for NO detection was also examined using square-wave voltammetry (SWV). The characterization of the modified electrode was carried out by cyclic voltammetry, electrochemical quartz crystal microbalance (EQCM) and SERS techniques. The gold electrode was successfully modified by the trans-[Ru(NH(3))(4)(Ist)SO(4)](+) complex ion using cyclic voltammetry. The experiments show that a monolayer of the film is achieved after ten voltammetric cycles, that NO in solution can coordinate to the metal present in the layer, that dopamine, serotonin and nitrite are interferents for the detection of NO, and that the response for the nitrite is much less significant than the responses for dopamine and serotonin. The proposed modified electrode has the potential to be applied as a sensor for NO. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
A graphite-polyurethane composite electrode has been used for the determination of furosemide, a antihypertensive drug, in pharmaceutical samples by anodic oxidation. Cyclic voltammetry and electrochemical impedance spectroscopy were used to characterize the electrooxidation process at +1.0 V vs. SCE over a wide pH range, with the result that no adsorption of analyte or products occurs, unlike at other carbon-based electrode materials. Quantification was carried out using cyclic voltammetry, differential pulse voltammetry, and square-wave voltammetry. Linear ranges were determined (up to 21 mu mol L-1 with cyclic voltammetry) as well as limits of detection (0.15 mu mol L-1 by differential pulse voltammetry). Four different types of commercial samples were successfully analyzed. Recovery tests were performed which agreed with those obtained by spectrophotometric evaluation. The advantages of this electrode material for repetitive analyzes, due to the fact that no electrode surface renewal is needed owing to the lack of adsorption, are highlighted.
Resumo:
The electrochemical methods cyclic and square-wave voltammetry were applied to develop an electroanalytical procedure for the determination of N-nitrosamines (N-nitrosopyrrolidine, N-nitrosopiperidine and N-nitrosodiethylamine) in aqueous solutions. Cyclic voltammetry was used to evaluate the electrochemical behaviors of N-nitrosamines on boron-doped diamond electrodes. It was observed an irreversible electrooxidation peak located in approximately 1.8 V (vs. Ag/AgCl) for both N-nitrosamines. The optimal electrochemical response was obtained using the following square-wave voltammetry parameters: f = 250 Hz, E(sw) = 50 mV and E(s) = 2 mV using a Britton-Robinson buffer solution as electrolyte (pH 2). The detection and quantification limits determined for total N-nitrosamines were 6.0 x 10(-8) and 2.0 x 10(-7) mol L(-1), respectively.
Resumo:
Composite electrodes were prepared using graphite powder and silicone rubber in different compositions. The use of such hydrophopic materials interned to diminish the swallowing observed in other cases when the electrodes are used in aqueous solutions for a long time. The composite was characterized for the response reproducibility, ohmic resistance, thermal behavior and active area. The voltammetric response in relation to analytes with known voltammetric behavior was also evaluated, always in comparison with the glassy carbon. The 70% (graphite, w/w) composite electrode was used in the quantitative determination of hydroquinone (HQ) in a DPV procedure in which a detection limit of 5.1 x 10(-8) mol L-1 was observed. HQ was determined in a photographic developer sample with errors lower then 1% in relation to the label value. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
A graphite silicone-rubber composite electrode (GSR) was used for the determination of propranolol in drug formulation. Cyclic voltammetry (CV) at the GSR presented an irreversible oxidation peak at + 0.8V vs. SCE, in Britton Robinson (B-R) buffer pH 7.4. The quantitative determination was carried out using differential pulse voltammetry (DPV). Under optimized parameters a linear dynamic range from 5.0 to 80.6 mu mol L(-1) with a detection limit of 1.1 mu mol L(-1) was observed. A repeatability of 4.5 +/- 0.1 mu A (n = 10) peak current was found after 10 successive DPV voltammograms of propranolol in the same solution after surface renovations. Using the proposed electrode, propranolol was quantified in a pharmaceutical formulation with results that agreed within 95% confidence level (t-test) with those from an official method.
Resumo:
A cathodically pretreated boron-doped diamond electrode was used for the simultaneous anodic determination of ascorbic acid (AA) and caffeine (CAF) by differential pulse voltammetry Linear calibration curves (r = 0 999) were obtained from 1 9 x 10(-5) to 2 I x 10(-4) mol L(-1) for AA and from 9 7 x 10(-6) to 1 1 x 10-4 mol L(-1) for CAF. with detection limits of 19 wool L(-1) and 7 0 mu nol L(-1). respectively This method was successfully applied for the determination of AA and CAF in pharmaceutical formulations. with results equal to those obtained using a HPLC reference method
Resumo:
A simple and highly selective electrochemical method was developed for the single or simultaneous determination of paracetamol (N-acetyl-p-aminophenol, acetaminophen) and caffeine (3,7-dihydro-1,3,7-trimethyl-1H-purine-2,6-dione) in aqueous media (acetate buffer, pH 4.5) on a boron-doped diamond (BDD) electrode using square wave voltammetry (SWV) or differential Pulse voltammetry (DPV). Using DPV with the cathodically pre-treated BDD electrode, a separation of about 550 mV between the peak oxidation potentials Of paracetamol and caffeine present in binary mixtures was obtained. The calibration curves for the simultaneous determination of paracetamol and caffeine showed an excellent linear response, ranging from 5.0 x 10(-7) mol L(-1) to 8.3 x 10(-7) mol L(-1) for both compounds. The detection limits for the simultaneous determination of paracetamol and caffeine were 4.9 x 10(-7) mol L-1 and 3.5 x 10(-8) mol L(-1), respectively. The proposed method Was Successfully applied in the simultaneous determination of paracetamol and caffeine in several pharmaceutical formulations (tablets), with results similar to those obtained using a high-performance liquid chromatography method (at 95% confidence level). (C) 2008 Elsevier BY. All rights reserved.
Resumo:
Program SOLVEJ är ett användarvänligt program som visar solens vandring över himlavalvet vid upp till fem valfria datum och vid valfri ort. Programmet är utvecklat av två skäl. För det första, att demonstreras för en intresserad allmänhet som del av vandringsutställning om solenergi, vilken är initierad och utarbetad av SERC. För det andra, att användas av solenerglintressenter för att snabbt få en uppfattning om solinstrålningen på en ort vid olika tidpunkter på året.Indata till programmet ges från tangentbordet. Som svar på frågor skrivs för vilken ort diagrammet skall gälla, max fem datum, ortens latitud och longitud, som anges positiv i västlig riktning, samt tidszonen. Varje uppgift avslutas med tryck på tangenten ENTER. Programmet kommer nu att rita ett koordinatsystem på skärmen. Första axeln visar vädersträcken, norr, öster, söder, väster och norr, varje delstreck utgör 10 grader. För södra halvklotet byter norr och söder plats. Andra axeln visar höjden över horisonten i grader, 0 till 90 grader och 10 grader för varje delstreck. Efter några sekunder ritas diagrammet upp med solhöjden som funktion av väderstrecket och varje hel timme markerad. Se fig. 1-4. Slutligen frågas efter om diagrammet skall ritas ut på printer. SOLVEJ avbrytes med att trycka CTRL+BREAK.SOLVEJ är skrivet i Quick-BASIC (se App. 1) och leveras både som källkod och körklar version. Lämplig dator är IBM-kompatibel AT med EGA- eller VGA-skärmkort (ej Herkules Lämplig printer är IBM Proprinter eller liknande matrisskrivare, kopplad till LPT1 på kommunikationskortet.Till grund för beräkningarna har använts artikeln On Calculating the Position of the Sun, publicerad i nr. 1 1988 av The International Journal of Ambient Energy. Fem empiriska ekvationer beträffande beräkningar av solens position har studerats för att undersöka deras tillförlitlighet. Felaktigheter på fem grader eller mer kan uppträda om man använder sig av de enkla ekvationer som kan hittas solenergi-böcker och som inte kräver tillgång till dator. FORTRAN-rutinen SUNAE2 (se App. 2) beräknar solpositionen med noggrannast kända metod. Program SOLVEJ är en utveckling av SUNAE2.
Resumo:
Childfree: a stigmatized position International research has addressed the subject but in Sweden voluntary childlessness has until now been overlooked. This article draws on qualitative, semi-structured interviews with 21 Swedish childfree women. The interviews focused their decision not to have children and attitudes they faced due to their rejection of motherhood. They all had encountered pressure to conform to a pronatalistic norm, proclaiming parenthood to be self-evident in an adult normal life. The results highlight different strategies used by the women to avoid instigating the dislike of those around them. The article argues that understanding childfree as a stigmatized position helps providing new insights to what conditions the social relations between the childfree and ‘the normals’, i.e. persons who advocate having children. Further, viewing the childfree as a stigmatized group has theoretical implications that contribute to developing Goffman’s classical theory of social stigma.
Resumo:
After Work. The long-term effects of work environment on the association between adult socioeconomic position and ill health among the elderly The aim of this study is to analyse the long-term effects of work environment on the association between adult socioeconomic position (SEP) and six ill health outcomes among the elderly. Data was drawn from the longitudinal Level of Living and the SWEOLD-surveys. The individuals are followed from 1968 to 1992 and from 1981 to 2002 and 2004, combining baseline information regarding SEP and work environment during the period of occupational activity with the ill health outcomes from the follow-up studies. Strongest effects where revealed when controlling for the physical work environment on the association between both measures of SEP and two of the ill health outcomes: musculoskeleta lpain and physical performance. The psychological work environment, however, explained very small parts of the associations. The results, even controlled for SEP, exposed strong direct relations between ill health and psychological work environment and rather strong relations to physical work environment. As socioeconomic position indicates a particular structural position within society it may determine the likelihood of health damaging exposures during the period of occupational activity. This study shows that the effect of work environment significantly affects ill health among the elderly. Hence, the results indicate the importance of taking measures in improving work environment during the labour-market participation period, especially since policy-makers attempt to convince workers to stay longer in the workforce.