957 resultados para Electric transformers -- Equipment and supplies
Resumo:
In this study, the measurement of the concentration and size of particles and the identification of their sources were carried out at five orthopedic surgeries. The aerosol concentration and particle size distribution, ranging from 0.3 mu m 10 mu m, were measured and related to the type of indoor activity. The handling of surgical linen and gowns, handling of the patient, use of electrosurgical apparatus, use of a bone saw, handling of equipment, and cleaning of the room were identified as the most important sources of particles, with each of these activities posing different risks to the health of the patients and workers. The results showed that most of the particles were above 0.5 mu m and that there was a strong correlation among all particles of sizes above 1 mu m. Particles with diameters in the range of 0.3 mu m-0.5 mu m had a good correlation only with particles in the ranges of 0.5 mu m-1.0 mu m and 1.0 mu m-3.0 mu m in three of the surgeries analyzed. Findings led to the conclusion that most of the events responsible for generating aerosol particles in an orthopedic surgery room are brief, intermittent, and highly variable, thus requiring the use of specific instrumentation for their continuous identification and characterization.
Resumo:
This research aimed to evaluate the occurrence of Staphylococcus aureus isolates in milk and in the milking environment of 10 small-scale farms (<400 L/d) located in the regions of Franca and Ribeirao Preto, state of Sao Paulo, Brazil. Two-hundred twenty samples of milk were collected from individual cows, along with 120 samples from bulk tank milk, 389 samples from milking equipment and utensils (teat cups, buckets, and sieves), and 120 samples from milkers' hands. Fifty-six Staph. aureus strains were isolated from 849 analyzed samples (6.6%): 12 (5.5%) from milk samples of individual cows, 26 (21.7%) from samples of bulk tank milk, 14 (3.6%) from samples collected from equipment and utensils, and 4 (3.3%) from samples from milkers' hands. Pulsed-field gel electrophoresis typing of the 56 Staph. aureus isolates by SmaI restriction enzyme resulted in 31 profiles (pulsotypes) arranged in 12 major clusters. Results of this study indicate a low incidence, but wide distribution of Staph. aureus strains isolated from raw milk collected from individual cows and surfaces of milkers' hands and milking equipment in the small-scale dairy farms evaluated. However, the high percentage of bulk milk samples found with Staph. aureus is of public health concern because raw, unprocessed milk is regularly consumed by the Brazilian population.
Resumo:
Introduction: The purpose of this study was to compare the anesthetic efficacy of 0.5% bupivacaine with 1:200,000 epinephrine with that of 2% lidocaine with 1:100,000 epinephrine during pulpectomy in patients with irreversible pulpitis in mandibular posterior teeth. Methods: Seventy volunteers, patients with irreversible pulpitis admitted to the Emergency Center of the School of Dentistry at the University of Sao Paulo, randomly received a conventional inferior alveolar nerve block containing 3.6 mL of either 0.5% bupivacaine with 1:200,000 epinephrine or 2% lidocaine with 1:100,000 epinephrine. During the subsequent pulpectomy, we recorded the patients subjective assessments of lip anesthesia, the absence/presence of pulpal anesthesia through electric pulp stimulation, and the absence/presence of pain through a verbal analog scale. Results: All patients reported lip anesthesia after the application of either inferior alveolar nerve block. By measuring pulpal anesthesia success with the pulp tester, lidocaine had a higher success rate (42.9%) than bupivacaine (20%). For patients reporting none or mild pain during pulpectomy, the success rate of bupivacaine was 80% and lidocaine was 62.9%. There were only statistically significant differences to the success of pulpal anesthesia. Conclusions: Neither of the solutions resulted in an effective pain control during irreversible pulpitis treatments of mandibular molars. (J Endod 2012;38:594-597)
Resumo:
The exploration of novel synthetic methodologies that control both size and shape of functional nanostructure opens new avenues for the functional application of nanomaterials. Here, we report a new and versatile approach to synthesize SnO2 nanocrystals (rutile-type structure) using microwave-assisted hydrothermal method. Broad peaks in the X-ray diffraction spectra indicate the nanosized nature of the samples which were indexed as a pure cassiterite tetragonal phase. Chemically and physically adsorbed water was estimated by TGA data and FT-Raman spectra to account for a new broad peak around 560 cm(-1) which is related to defective surface modes. In addition, the spherical-like morphology and low dispersed distribution size around 3-5 nm were investigated by HR-TEM and FE-SEM microscopies. Room temperature PL emission presents two broad bands at 438 and 764 nm, indicating the existence of different recombination centers. When the size of the nanospheres decreases, the relative intensity of 513 nm emission increases and the 393 nm one decreases. UV-Visible spectra show substantial changes in the optical absorbance of crystalline SnO2 nanoparticles while the existence of a small tail points out the presence of localized levels inside the forbidden band gap and supplies the necessary condition for the PL emission.
Resumo:
The purpose of this work was to verify the benthic macroinvertebrates community responses through environmental factors along a headwater tropical reservoir. Samplings were taken with a Van-Veen grab along the reservoir in littoral and profundal regions and in the headwater, next to the dam and the middle of the reservoir. Samples were taken during both wet and dry seasons. Dissolved oxygen concentrations, electric conductivity, temperature and pH near the sediment have been performed in situ, at every sampling station by using a multiprobe and Secchi disc. Total water phosphorus and chlorophyll a concentrations were analyzed to determine the trophic state index. Sediment's organic matter, total phosphorus, nitrogen concentrations and granulometric composition were measured. In order to verify which environmental variables would have more influence over the benthic macroinvertebrates community, a canonical correspondence analysis (CCA) was performed. The total number of recorded taxa was 28. Among them, the family Chironomidae (Diptera) was the richest group (19 taxa). It can be proposed that the benthic macroinvertebrates community may be influenced by environmental conditions such as nutrient and organic matter availability, as well as dissolved oxygen concentration. Macroinvertebrates are adequate bioindicators of water quality due to their sensibility to environmental changes mentioned before. Chironomus sp, Limnodrilus hoffmeisteri and Branchiura sowerbyi comprises a group that can be considered bio-indicators of eutrophic conditions. A second group can be considered as indicator of mesotrophic conditions. The presence of two or more members from that group which comprises Tanytarsini spp, Fissimentum sp, Pelomus sp and Goeldichironomus sp, like predominant taxa, may indicates mesotrophic conditions.
Resumo:
A main objective of the human movement analysis is the quantitative description of joint kinematics and kinetics. This information may have great possibility to address clinical problems both in orthopaedics and motor rehabilitation. Previous studies have shown that the assessment of kinematics and kinetics from stereophotogrammetric data necessitates a setup phase, special equipment and expertise to operate. Besides, this procedure may cause feeling of uneasiness on the subjects and may hinder with their walking. The general aim of this thesis is the implementation and evaluation of new 2D markerless techniques, in order to contribute to the development of an alternative technique to the traditional stereophotogrammetric techniques. At first, the focus of the study has been the estimation of the ankle-foot complex kinematics during stance phase of the gait. Two particular cases were considered: subjects barefoot and subjects wearing ankle socks. The use of socks was investigated in view of the development of the hybrid method proposed in this work. Different algorithms were analyzed, evaluated and implemented in order to have a 2D markerless solution to estimate the kinematics for both cases. The validation of the proposed technique was done with a traditional stereophotogrammetric system. The implementation of the technique leads towards an easy to configure (and more comfortable for the subject) alternative to the traditional stereophotogrammetric system. Then, the abovementioned technique has been improved so that the measurement of knee flexion/extension could be done with a 2D markerless technique. The main changes on the implementation were on occlusion handling and background segmentation. With the additional constraints, the proposed technique was applied to the estimation of knee flexion/extension and compared with a traditional stereophotogrammetric system. Results showed that the knee flexion/extension estimation from traditional stereophotogrammetric system and the proposed markerless system were highly comparable, making the latter a potential alternative for clinical use. A contribution has also been given in the estimation of lower limb kinematics of the children with cerebral palsy (CP). For this purpose, a hybrid technique, which uses high-cut underwear and ankle socks as “segmental markers” in combination with a markerless methodology, was proposed. The proposed hybrid technique is different than the abovementioned markerless technique in terms of the algorithm chosen. Results showed that the proposed hybrid technique can become a simple and low-cost alternative to the traditional stereophotogrammetric systems.
Resumo:
Studies of organic fluorescent dyes are experiencing a renaissance related to the increasing demands posed by new microscopy techniques for high resolution and high sensitivity. While in the last decade single molecule equipment and methodology has significantly advanced and in some cases reached theoretical limits (e.g. detectors approaching unity quantum yields) unstable emission from chromophores and photobleaching become more and more the bottleneck of the advancement and spreading of single-molecule fluorescence studies. The main goal of this work was the synthesis of fluorophores that are water-soluble, highly fluorescent in an aqueous environment, have a reactive group for attachment to a biomolecule and posses exceptional photostability. An approach towards highly fluorescent, water-soluble and monofunctional perylene-3,4,9,10-tetracarboxdiimide and terrylene-3,4:11,12-tetra carboxidiimide chromophores was presented. A new synthetic strategy for the desymmetrization of perylenetetracarboximides was elaborated; water-solubility was accomplished by introducing sulfonyl substituents in the phenoxy ring. Two strategies have been followed relying on either non-specific or site specific labeling. For this purpose a series of new water-soluble monofunctional perylene and terrylene dyes, bearing amine or carboxy group were prepared. The reactivity and photophysical properties of these new chromophores were studied in aqueous medium. The most suitable chromophores were further derivatized with amine or thiol reactive groups, suitable for chemical modification of proteins. The performance of the new fluorescent probes was assessed by single molecule enzyme tracking, in this case phospholipase acting on phospholipid supported layers. Phospholipase-1 (PLA-1) was labeled with N-hydroxysuccinimide ester functionalized perylene and terrylene derivatives. The purification of the conjugates was accomplished by novel convenient procedure for the removal of unreacted dye from labeled enzymes, which involves capturing excess dye with a solid support. This novel strategy for purification of bioconjugates allows convenient and fast separation of labeled proteins without the need for performing time consuming chromatographic or electrophoretic purification steps. The outstanding photostability of the dyes and, associated therewith, the extended survival times under strong illumination conditions allow a complete characterization of enzyme action on its natural substrates and even connecting enzyme mobility to catalytic activity. For site-specific attachment of the rylene dyes to proteins the chromophores were functionalized with thioesters or nitrilotriacetic acid groups. This allowed attachment of the emitters to the N-terminus of proteins by native chemical ligation or complexation with His-tagged polypeptides at the N- or C-termini, respectively. The synthesis of a water-soluble perylenebis (dicarboximide) functionalized with a thioester group was presented. This chromophore exhibits an exceptional photostability and a functional unit for site-specific labeling of proteins. The suitability of the fluorophore as a covalent label was demonstrated via native chemical ligation with protein containing N-terminal cystein residue. We exploited also oligohisitidine sequences as recognition elements for site-selective labeling. The synthesis of a new water-soluble perylene chromophore, containing a nitrilotriacetic acid functional group was demonstrated, using solution-phase and solid-phase approaches. This chromophore combines the exceptional photophysical properties of the rylene dyes and a recognition unit for site-specific labeling of proteins. An important feature of the label is the unchanged emission of the dye upon complexation with nickel ions.
Resumo:
Throughout the twentieth century statistical methods have increasingly become part of experimental research. In particular, statistics has made quantification processes meaningful in the soft sciences, which had traditionally relied on activities such as collecting and describing diversity rather than timing variation. The thesis explores this change in relation to agriculture and biology, focusing on analysis of variance and experimental design, the statistical methods developed by the mathematician and geneticist Ronald Aylmer Fisher during the 1920s. The role that Fisher’s methods acquired as tools of scientific research, side by side with the laboratory equipment and the field practices adopted by research workers, is here investigated bottom-up, beginning with the computing instruments and the information technologies that were the tools of the trade for statisticians. Four case studies show under several perspectives the interaction of statistics, computing and information technologies, giving on the one hand an overview of the main tools – mechanical calculators, statistical tables, punched and index cards, standardised forms, digital computers – adopted in the period, and on the other pointing out how these tools complemented each other and were instrumental for the development and dissemination of analysis of variance and experimental design. The period considered is the half-century from the early 1920s to the late 1960s, the institutions investigated are Rothamsted Experimental Station and the Galton Laboratory, and the statisticians examined are Ronald Fisher and Frank Yates.
Resumo:
Nowadays the medical field is struggling to decrease bacteria biofilm formation which leads to infection. Biomedical devices sterilization has not changed over a long period of time. This results in high costs for hospitals healthcare managements. The objective of this project is to investigate electric field effects and surface energy manipulation as solutions for preventing bacteria biofilm for future devices. Based on electrokinectic environments 2 different methods were tested: feasibility of electric gradient through mediums (DEP) reinforced by numerical simulations; and EWOD by the fabrication of golden interdigitated electrodes on silicon glass substrates, standard ~480 nm Teflon (PTFE) layer and polymeric gasket to contain the bacteria medium. In the first experiment quantitative analysis was carried out to achieve forces required to reject bacteria without considering dielectric environment limitations as bacteria and medium frequency dependence. In the second experiment applied voltages was characterized by droplets contact angle measurements and put to the live bacteria tests. The project resulted on promising results for DEP application due to its wide range of frequency that can be used to make a “general” bacteria rejecting; but in terms of practicality, EWOD probably have higher potential for success but more experiments are needed to verify if can prevent biofilm adhesion besides the Teflon non-adhesive properties (including limitations as Teflon breakthrough, layer sensitivity) at incubation times larger than 24 hours.
Resumo:
Diagnostic and therapeutic approaches to trauma patients are, depending on experience, equipment and different therapeutic doctrines, subject to wide variations. The ability to compare trauma centres using a standardised trauma register helps to reveal unresolved systemic issues and simplifies the quality management in an Emergency Department (ED).
Resumo:
Background Backyard trampolines are immensely popular among children, but are associated with an increase of trampoline-related injuries. The aim of this study was to evaluate radiographs of children with trampoline related injuries and to determine the risk factors. Methods Between 2003 and 2009, 286 children under the age of 16 with backyard trampoline injuries were included in the study. The number of injuries increased from 13 patients in 2003 to 86 in 2009. The median age of the 286 patients was 7 years (range: 1–15 years). Totally 140 (49%) patients were males, and 146 (51%) females. Medical records and all available diagnostic imaging were reviewed. A questionnaire was sent to the parents to evaluate the circumstances of each injury, the type of trampoline, the protection equipment and the experience of the children using the trampoline. The study was approved by the Institutional Ethics Committee of the University Hospital of Bern. Results The questionnaires and radiographs of the 104 patients were available for evaluation. A fracture was sustained in 51 of the 104 patients. More than 75% of all patients sustaining injuries and in 90% of patients with fractures were jumping on the trampoline with other children at the time of the accident. The most common fractures were supracondylar humeral fractures (29%) and forearm fractures (25%). Fractures of the proximal tibia occurred especially in younger children between 2–5 years of age. Conclusions Children younger than 5 years old are at risk for specific proximal tibia fractures (“Trampoline Fracture”). A child jumping simultaneously with other children has a higher risk of suffering from a fracture.
Resumo:
To assess the prevalence of tooth wear on buccal/facial and lingual/palatal tooth surfaces and identify related risk factors in a sample of young European adults, aged 18-35 years. Calibrated and trained examiners measured tooth wear, using the basic erosive wear examination (BEWE) on in 3187 patients in seven European countries and assessed the impact of risk factors with a previously validated questionnaire. Each individual was characterized by the highest BEWE score recorded for any scoreable surface. Bivariate analyses examined the proportion of participants who scored 2 or 3 in relation to a range of demographic, dietary and oral care variables. The highest tooth wear BEWE score was 0 for 1368 patients (42.9%), 1 for 883 (27.7%), 2 for 831 (26.1%) and 3 for 105 (3.3%). There were large differences between different countries with the highest levels of tooth wear observed in the UK. Important risk factors for tooth wear included heartburn or acid reflux, repeated vomiting, residence in rural areas, electric tooth brushing and snoring. We found no evidence that waiting after breakfast before tooth brushing has any effect on the degree of tooth wear (p=0.088). Fresh fruit and juice intake was positively associated with tooth wear. In this adult sample 29% had signs of tooth wear making it a common presenting feature in European adults.
Resumo:
There is still discussion regarding whether liquid biofuels can contribute to rural energy security in the global South. We argue that transitioning to a village energy supply based on jatropha hedges around smallholder plots is possible, but requires collective effort for the acquisition and maintenance of processing equipment and for the running of village generators. The use of jatropha oil for lighting in rural households is affordable and technically possible, but not ideal if more efficient electric solutions exist. Cooking with jatropha oil or press cake is also possible, but quantities produced in hedges can only substitute a small part of the firewood used by rural households.
Resumo:
Abstract The objectives of this study were: 1) To determine factors which inhibit and facilitate child and adolescent use of outdoor spaces for healthy physical activity by race and ethnicity in four Houston communities and 2) To propose guidelines for encouraging and maintaining child and adolescent outdoor physical activity. Using local health data and Houston Police Department crime statistics, four communities were identified for the study that had the highest concentration of crime and the racial/ ethnic groups of interest. The researchers then identified public parks in the communities. At least two parks were observed in each of the four communities from 2010 to 2011 during spring, summer, fall and winter. The parks were observed for use by children and adolescents and to describe the condition of the park spaces. The communities were Alief (Asian), Sunnyside (Black), Eldridge- West Oaks (White) and Northside- Northline (Hispanic). Observations were made at varying hours of both day and night, weekdays and weekends. Photographs were taken and the condition of the spaces noted in detail. One hundred and twenty persons, 18 years and over, using the spaces or otherwise in these communities were conveniently sampled and interviewed about their health and the extent to which they, or any children or adolescents under their care, used the outdoor spaces of interest. Data were analyzed qualitatively and with basic descriptive statistics. The photographs, journal notes and observation notes of all investigators and key personnel were analyzed. Interview data were also coded to identify patterns and themes in the responses. The findings indicate disparities in the quality and quantity of park equipment and the maintenance of the areas. Where perceptions of disorder were described, there was often visible evidence to support the perceptions. In many cases, residents' perceptions of crime were corroborated by police data. While interview reports did not seem to support the expectation that the condition of the parks was a significant deterrent to their use by children and adolescents, the condition of the parks might be said to limit the extent of that use. Specific reports of disorder that inhibited use included hearing gunfire, seeing drug dependent homeless persons and/or suspected prostitutes in an area.
Resumo:
Five test runs were performed to assess possible bias when performing the loss on ignition (LOI) method to estimate organic matter and carbonate content of lake sediments. An accurate and stable weight loss was achieved after 2 h of burning pure CaCO3 at 950 °C, whereas LOI of pure graphite at 530 °C showed a direct relation to sample size and exposure time, with only 40-70% of the possible weight loss reached after 2 h of exposure and smaller samples losing weight faster than larger ones. Experiments with a standardised lake sediment revealed a strong initial weight loss at 550 °C, but samples continued to lose weight at a slow rate at exposure of up to 64 h, which was likely the effect of loss of volatile salts, structural water of clay minerals or metal oxides, or of inorganic carbon after the initial burning of organic matter. A further test-run revealed that at 550 °C samples in the centre of the furnace lost more weight than marginal samples. At 950 °C this pattern was still apparent but the differences became negligible. Again, LOI was dependent on sample size. An analytical LOI quality control experiment including ten different laboratories was carried out using each laboratory's own LOI procedure as well as a standardised LOI procedure to analyse three different sediments. The range of LOI values between laboratories measured at 550 °C was generally larger when each laboratory used its own method than when using the standard method. This was similar for 950 °C, although the range of values tended to be smaller. The within-laboratory range of LOI measurements for a given sediment was generally small. Comparisons of the results of the individual and the standardised method suggest that there is a laboratory-specific pattern in the results, probably due to differences in laboratory equipment and/or handling that could not be eliminated by standardising the LOI procedure. Factors such as sample size, exposure time, position of samples in the furnace and the laboratory measuring affected LOI results, with LOI at 550 °C being more susceptible to these factors than LOI at 950 °C. We, therefore, recommend analysts to be consistent in the LOI method used in relation to the ignition temperatures, exposure times, and the sample size and to include information on these three parameters when referring to the method.