997 resultados para Determination coefficients


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Candida albicans is a commensal and opportunistic agent that causes infection in immunocompromised individuals. Several attributes contribute to the virulence and pathogenicity of this yeast, including the production of germ tubes (GTs) and extracellular hydrolytic enzymes, particularly phospholipase and proteinase. This study aimed to investigate GT production and phospholipase and proteinase activities in bloodstream isolates of C. albicans. Methods One hundred fifty-three C. albicans isolates were obtained from blood samples and analyzed for GT, phospholipase, and proteinase production. The assays were performed in duplicate in egg yolk medium containing bovine serum albumin and human serum. Results Detectable amounts of proteinase were produced by 97% of the isolates, and 78% of the isolates produced phospholipase. GTs were produced by 95% of the isolates. A majority of the isolates exhibited low levels of phospholipase production and high levels of proteinase production. Conclusions Bloodstream isolates of C. albicans produce virulence factors such as GT and hydrolytic enzymes that enable them to cause infection under favorable conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cylindrical specimens of bone measuring 15 mm in diameter were obtained from the lateral cortical layer of 10 pairs of femurs and tibias. A central hole 3.2 mm in diameter was drilled in each specimen. The hole was tapped, and a 4.5 mm cortical bone screw was inserted from the outer surface. The montage was submitted to push-out testing up to a complete strip of the bone threads. The cortical thickness and rupture load were measured, and the shear stress was calculated. The results were grouped according to the bone segment from which the specimen was obtained. The results showed that bone cortex screw holding power is dependent on the bone site. Additionally, the diaphyseal cortical bone tissue is both quantitatively and qualitatively more resistant to screw extraction than the metaphyseal tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It was found that fish livers from the Amazon have considerable amounts of vitamins A, D and E compared with the values of the standartized cod-liver oil. Tambaqui liver oil has high concentration of vitamin A1(retinol) and vitamin A2 (degidroretinol) whereas the liver oils of pirarucu and cuiu-cuiu have preferently the vitamin A2. The contents of the vitamins D and E observed in the liver oils of tambaqui and cuiu-cuiu was extremely high.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main iridoids from the bark and latex of Himatanthus sucuuba were isolated and characterised by spectroscopic methods. HPLC was used for the quantitative analyses of these iridoids and the chromatograms of bark and latex showed a similar iridoid composition. Both parts of the plant are used in folk medicine for the treatment of various ailments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is successfully demonstrated that nanoparticle’s magnetostriction can be accurately determined based on the magnetoelectric effect measured on polymeric-composite materials. This represents a novel, simple and versatile method for the determination of particle’s magnetostriction at their nano-sized and dispersed state, which is, up to date, a difficult and imprecise task.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An ion chromatography procedure, employing an IonPac AC15 concentrator column was used to investigate on line preconcentration for the simultaneous determination of inorganic anions and organic acids in river water. Twelve organic acids and nine inorganic anions were separated without any interference from other compounds and carry-over problems between samples. The injection loop was replaced by a Dionex AC15 concentrator column. The proposed procedure employed an auto-sampler that injected 1.5 ml of sample into a KOH mobile phase, generated by an Eluent Generator, at 1.5 mL min-1, which carried the sample to the chromatographic columns (one guard column, model AG-15, and one analytical column, model AS15, with 250 x 4mm i.d.). The gradient elution concentrations consisted of a 10.0 mmol l-1 KOH solution from 0 to 6.5 min, gradually increased to 45.0 mmol l-1 KOH at 21 min., and immediatelly returned and maintained at the initial concentrations until 24 min. of total run. The compounds were eluted and transported to an electro-conductivity detection cell that was attached to an electrochemical detector. The advantage of using concentrator column was the capability of performing routine simultaneous determinations for ions from 0.01 to 1.0 mg l-1 organic acids (acetate, propionic acid, formic acid, butyric acid, glycolic acid, pyruvate, tartaric acid, phthalic acid, methanesulfonic acid, valeric acid, maleic acid, oxalic acid, chlorate and citric acid) and 0.01 to 5.0 mg l-1 inorganic anions (fluoride, chloride, nitrite, nitrate, bromide, sulfate and phosphate), without extensive sample pretreatment and with an analysis time of only 24 minutes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies of the spin and parity quantum numbers of the Higgs boson in the WW∗→eνμν final state are presented, based on proton--proton collision data collected by the ATLAS detector at the Large Hadron Collider, corresponding to an integrated luminosity of 20.3 fb−1 at a centre-of-mass energy of s√=8 TeV. The Standard Model spin-parity JCP=0++ hypothesis is compared with alternative hypotheses for both spin and CP. The case where the observed resonance is a mixture of the Standard-Model-like Higgs boson and CP-even (JCP=0++) or CP-odd (JCP=0+−) Higgs boson in scenarios beyond the Standard Model is also studied. The data are found to be consistent with the Standard Model prediction and limits are placed on alternative spin and CP hypotheses, including CP mixing in different scenarios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Giant of Amazon basin, pirarucu, Arapaima gigas, is the largest scaled freshwater fish in the world. pirarucu cultivation has recently started, driven by the decline in natural populations and high market value. Currently, there are no reliable methods for sexual differentiation in this species other than direct examination of gonads, which requires dissection of specimens. A non-lethal and less invasive method for sexual identification is highly desirable in order to properly group broodstock for mating and offspring production. We utilized laparoscopic examination in anesthetized pirarucu to differentiate between male and female individuals. This method allowed for the observation and differentiation of the reproductive organs within an individual. Our results suggest that laparoscopy is an efficient method for sex differentiation in pirarucu causing minimal stress to the fish.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study was carried out to evaluate the association of levels of radioactivity, selenium and aflatoxin in shelled Brazil nuts, which were classified in different sizes, for export. The selenium determinations were performed by inductively coupled plasma optical emission spectrometry (LOQ = 3.0 µg g-1), and aflatoxins were detected by Liquid chromatography-mass spectrometry (LOQ = 0.85 µg kg-1), recovery rates were between 92 and 100%. Radioactivity was measured by high-resolution gamma spectrometry. The selenium mean concentration was (22.7 ± 7.4) µg g-1. (n = 30). Mean activities determined for the following radium isotopes were: 15.77 Bq kg-1 for 224Ra, 104.8 Bq kg-1 for 226Ra and 99.48 Bq kg-1 for 228Ra. For 226Ra, the levels did not vary significantly with nut sizes, although such differences were observed for 224Ra and 228Ra. There was no statistically significant association between the level of selenium and the activity of radionuclides, however, there was correlation between the radionuclides. Aflatoxins above the quantification limit were not found.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The normalized differential cross section for top-quark pair production in association with at least one jet is studied as a function of the inverse of the invariant mass of the tt¯+1-jet system. This distribution can be used for a precise determination of the top-quark mass since gluon radiation depends on the mass of the quarks. The experimental analysis is based on proton--proton collision data collected by the ATLAS detector at the LHC with a centre-of-mass energy of 7 TeV corresponding to an integrated luminosity of 4.6 fb−1. The selected events were identified using the lepton+jets top-quark-pair decay channel, where lepton refers to either an electron or a muon. The observed distribution is compared to a theoretical prediction at next-to-leading-order accuracy in quantum chromodynamics using the pole-mass scheme. With this method, the measured value of the top-quark pole mass, mpolet, is: mpolet =173.7 ± 1.5 (stat.) ± 1.4 (syst.) +1.0−0.5 (theory) GeV. This result represents the most precise measurement of the top-quark pole mass to date.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High transverse momentum jets produced in pp collisions at a centre of mass energy of 7 TeV are used to measure the transverse energy--energy correlation function and its associated azimuthal asymmetry. The data were recorded with the ATLAS detector at the LHC in the year 2011 and correspond to an integrated luminosity of 158 pb−1. The selection criteria demand the average transverse momentum of the two leading jets in an event to be larger than 250 GeV. The data at detector level are well described by Monte Carlo event generators. They are unfolded to the particle level and compared with theoretical calculations at next-to-leading-order accuracy. The agreement between data and theory is good and provides a precision test of perturbative Quantum Chromodynamics at large momentum transfers. From this comparison, the strong coupling constant given at the Z boson mass is determined to be αs(mZ)=0.1173±0.0010 (exp.) +0.0065−0.0026 (theo.).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento em Engenharia Civil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of genome-scale metabolic models has been rapidly increasing in fields such as metabolic engineering. An important part of a metabolic model is the biomass equation since this reaction will ultimately determine the predictive capacity of the model in terms of essentiality and flux distributions. Thus, in order to obtain a reliable metabolic model the biomass precursors and their coefficients must be as precise as possible. Ideally, determination of the biomass composition would be performed experimentally, but when no experimental data are available this is established by approximation to closely related organisms. Computational methods however, can extract some information from the genome such as amino acid and nucleotide compositions. The main objectives of this study were to compare the biomass composition of several organisms and to evaluate how biomass precursor coefficients affected the predictability of several genome-scale metabolic models by comparing predictions with experimental data in literature. For that, the biomass macromolecular composition was experimentally determined and the amino acid composition was both experimentally and computationally estimated for several organisms. Sensitivity analysis studies were also performed with the Escherichia coli iAF1260 metabolic model concerning specific growth rates and flux distributions. The results obtained suggest that the macromolecular composition is conserved among related organisms. Contrasting, experimental data for amino acid composition seem to have no similarities for related organisms. It was also observed that the impact of macromolecular composition on specific growth rates and flux distributions is larger than the impact of amino acid composition, even when data from closely related organisms are used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Bioengenharia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[Excerpt] Introduction: There has been a considerable amount of controversy about the use of manometric methods to measure catalase activity. As Maehly and Chance point out in their excellent review] the advantages of these methods is "... that they can be used for any kind of biological material, and purification of the enzyme is not required. The assay is independent of small amounts of peroxidase activity. It is fairly simple to perform, it is rapid and it can be adapted to continuous reading of the reaction". A variety of drawbacks are also listed by the same authors, viz, the inactivation of the enzyme under the experimental conditions and the time lag before a constant rate of oxygen evolution is reached. [...]