This study investigated the surface hardening of steels via experimental tests using a multi-kilowatt fiber laser as the laser source. The influence of laser power and laser power density on the hardening effect was investigated. The microhardness analysis of various laser hardened steels was done. A thermodynamic model was developed to evaluate the thermal process of the surface treatment of a wide thin steel plate with a Gaussian laser beam. The effect of laser linear oscillation hardening (LLOS) of steel was examined. An as-rolled ferritic-pearlitic steel and a tempered martensitic steel with 0.37 wt% C content were hardened under various laser power levels and laser power densities. The optimum power density that produced the maximum hardness was found to be dependent on the laser power. The effect of laser power density on the produced hardness was revealed. The surface hardness, hardened depth and required laser power density were compared between the samples. Fiber laser was briefly compared with high power diode laser in hardening medium-carbon steel. Microhardness (HV0.01) test was done on seven different laser hardened steels, including rolled steel, quenched and tempered steel, soft annealed alloyed steel and conventionally through-hardened steel consisting of different carbon and alloy contents. The surface hardness and hardened depth were compared among the samples. The effect of grain size on surface hardness of ferritic-pearlitic steel and pearlitic-cementite steel was evaluated. In-grain indentation was done to measure the hardness of pearlitic and cementite structures. The macrohardness of the base material was found to be related to the microhardness of the softer phase structure. The measured microhardness values were compared with the conventional macrohardness (HV5) results. A thermodynamic model was developed to calculate the temperature cycle, Ac1 and Ac3 boundaries, homogenization time and cooling rate. The equations were numerically solved with an error of less than 10-8. The temperature distributions for various thicknesses were compared under different laser traverse speed. The lag of the was verified by experiments done on six different steels. The calculated thermal cycle and hardened depth were compared with measured data. Correction coefficients were applied to the model for AISI 4340 steel. AISI 4340 steel was hardened by laser linear oscillation hardening (LLOS). Equations were derived to calculate the overlapped width of adjacent tracks and the number of overlapped scans in the center of the scanned track. The effect of oscillation frequency on the hardened depth was investigated by microscopic evaluation and hardness measurement. The homogeneity of hardness and hardened depth with different processing parameters were investigated. The hardness profiles were compared with the results obtained with conventional single-track hardening. LLOS was proved to be well suitable for surface hardening in a relatively large rectangular area with considerable depth of hardening. Compared with conventional single-track scanning, LLOS produced notably smaller hardened depths while at 40 and 100 Hz LLOS resulted in higher hardness within a depth of about 0.6 mm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work the implementation of the active magnetic bearing control system in a single FPGA is studied. Requirements for the full magnetic bearing control system are reviewed. Different control methods for active magnetic bearings are described shortly. Flux and the current base controllers are implemented in a FPGA. Suitability of the con-trollers for a low-cost magnetic bearing application is studied. Floating-point arithmetic’s are used in the controllers to ease designing burden and improve calculation precision. Per-formance of the flux controller is verified with simulations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study was conducted to evaluate the predictive diagnostic value of different copper (Cu) parameters as indicators of average daily gain (ADG) in growing calves. The effects in calves of cow Cu supplementation in the last one-third gestation period were also evaluated. Five supplementation trials, with a total of 300 calves, were carried out. Two groups of 30 calves were randomly assigned to each trial, one group was parenterally supplemented (SG) and the other was not supplemented (NSG). Trials began when calves were three-month-old and ended at weaning time. At each sampling calves were weighed and blood was taken to determine Cu concentrations in plasma, Whole Blood (WB), Red Cells (RC) and Packed Cell Volume (PCV). Liver samples from six animals of each group were taken both at the beginning and at the end of the trial. In two trials the mothers of the SG received Cu supplementation at the last one- third gestation period. Four of the five trials exhibited low ADG in the NSGs. In these groups, plasma Cu concentration decreased rapidly before low ADG was detected, which occurred with values remaining below 25µg/dl. The decrease of RC Cu concentration was considerably slow. WB showed an intermediate position. PCV in the SGs was higher than in the NSGs in all trials. Cow supplementation was insufficient to generate a liver storage able to last after calves reached the 3 months of age. These data could be useful to predict the risk of low ADG in grazing calves.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to estimate the diagnostic value of renal cortex copper (Cu) concentration in clinical cases of acute copper poisoning (ACP). A total of 97 calves that died due to subcutaneous copper administration were compiled in eleven farms. At least, one necropsy was conducted on each farm and samples for complementary analysis were taken. The degree of autolysis in each necropsy was evaluated. The cases appeared on extensive grazing calf breeding and intensive feedlot farms, in calves of 60 to 200 kg body weight. Mortality varied from 0.86 to 6.96 %, on the farms studied. The first succumbed calf was found on the farms between 6 and 72 hours after the susbcutaneous Cu administration. As discrepancies regarding the reference value arose, the local value (19.9 parts per million) was used, confirming the diagnosis of acute copper poisoning in 93% of the analyzed kidney samples. These results confirm the value of analysis of the cortical kidney Cu concentration for the diagnosis of acute copper poisoning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tutkimuksen tavoitteena on selvittää tarkoituksenmukaisin etabloitumismenetelmä teräsyhtiön kansainvälistymisessä Pietarin markkinoille. Vaikka kansainvälistymistä onkin tutkittu paljon, kyseisen kontekstin erityispiirteisiin on aiemmissa tutkimuksissa kiinnitetty vain vähän huomiota. Kansainvälistymisteorioista työhön valittiin John Dunningin eklektinen paradigma sekä Uppsala-malli. Etabloitumismenetelmän valintaa puolestaan tarkastellaan eri vaihtoehtojen kautta, jotka kattavat viennin, suorat ulkomaan investoinnit, sopimusjärjestelyt sekä yhteisyrityksen. Valintaa selitetään taustalla vaikuttavien tekijöiden sekä kansainvälistymisprosessin kautta. Kohteena olevan markkina-alueen potentiaalin, ongelmien sekä yrityksen kilpailuetujen arvioinnin jälkeen ehdotetaan optimaalista ratkaisua. Omat haasteensa operaatiomuodon valintaan luovat potentiaalinen mutta haastava kohdemarkkina-alue sekä yrityksen sisäiset tekijät. Kontekstiin parhaiten sopivaksi etabloitumismenetelmäksi esitetään aloittamista välittömällä viennillä asiakkaiden etsimiseksi ja suhteiden luomiseksi. Kun asiakkuuksia alueella on riittävästi, myyntikonttorin perustaminen Pietarin lähelle nähdään tarkoituksenmukaisena paikallisen läsnäolon lisäämiseksi. Empiirinen data kattaa kahdeksan asiantuntijahaastattelua, jotka yhdessä muun lähdeaineiston kanssa rakentavat perustan empiirisille tuloksille. Tutkimuksen tulokset tarjoavat yritykselle perustellun ratkaisuehdotuksen siitä, kuinka Pietarin markkinoille tulisi etabloitua.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Large amplitude bus bar aeolian vibration may lead to post insulator damage. Different damping applications are used to decrease the risk of large amplitude aeolian vibration. In this paper the post insulator load caused by the bus bar aeolian vibration and the effect of damping methods are evaluated. The effects of three types of bus bar connectors and three types of primary structures are studied. Two actual damping devices, damping cable and their combinations are studied. The post insulator loads are studied with strain gage based custom made force sensors installed on the both ends of the post insulator and with the displacement sensor installed on the midpoint of the bus bar. The post insulator loads are calculated from the strain values and the damping properties are determined from the displacement history. The bus bar is deflected with a hanging weight. The weight is released and the bus bar is left to free damped vibration. Both actual bus bar vibration dampers RIBE and SBI were very effective against the aeolian vibration. Combining vibration damper with damping cable will increase the damping ratio but it may be unnecessary considering the extra effort. Bus bar connector type or primary structure have no effect on the vertical load. The bending moment at the post insulator with double sided bus bar connector is significantly higher than at the post insulator with single sided bus bar connector. No reliable conclusions about bus bar connector type effect can be done, but the roller bearing type or central bearing type connector may reduce the bending moment. The RHS steel frame as primary structure may increase the bending moment peak values since it is the least rigid primary structure type and it may start to vibrate as a response to the awakening force of the vibrating bus bar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates defect detection methodologies for rolling element bearings through vibration analysis. Specifically, the utility of a new signal processing scheme combining the High Frequency Resonance Technique (HFRT) and Adaptive Line Enhancer (ALE) is investigated. The accelerometer is used to acquire data for this analysis, and experimental results have been obtained for outer race defects. Results show the potential effectiveness of the signal processing technique to determine both the severity and location of a defect. The HFRT utilizes the fact that much of the energy resulting from a defect impact manifests itself in the higher resonant frequencies of a system. Demodulation of these frequency bands through use of the envelope technique is then employed to gain further insight into the nature of the defect while further increasing the signal to noise ratio. If periodic, the defect frequency is then present in the spectra of the enveloped signal. The ALE is used to enhance the envelope spectrum by reducing the broadband noise. It provides an enhanced envelope spectrum with clear peaks at the harmonics of a characteristic defect frequency. It is implemented by using a delayed version of the signal and the signal itself to decorrelate the wideband noise. This noise is then rejected by the adaptive filter that is based upon the periodic information in the signal. Results have been obtained for outer race defects. They show the effectiveness of the methodology to determine both the severity and location of a defect. In two instances, a linear relationship between signal characteristics and defect size is indicated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present paper is to study the relationship between the fracture modes in hydrogen-assisted cracking (HAC) in microalloied steel and the emission of acoustic signals during the fracturing process. For this reason, a flux-cored arc weld (FCAW) was used in a high-strength low-alloy steel. The consumable used were the commercially available AWS E120T5-K4 and had a diameter of 1.6 mm. Two different shielding gases were used (CO2 and CO2+5% H2) to obtain complete phenomenon characterization. The implant test was applied with three levels of restriction stresses. An acoustic emission measurement system (AEMS) was coupled to the implant test apparatus. The output signal from the acoustic emission sensor was passed through an electronic amplifier and processed by a root mean square (RMS) voltage converter. Fracture surfaces were examined by scanning electron microscopy (SEM) and image analysis. Fracture modes were related with the intensity, the energy and the number of the peaks of the acoustic emission signal. The shielding gas CO2+5% H2 proved to be very useful in the experiments. Basically, three different fracture modes were identified in terms of fracture appearance: microvoid coalescence (MVC), intergranular (IG) and quasi-cleavage (QC). The results show that each mode of fracture presents a characteristic acoustic signal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Crack formation and growth in steel bridge structural elements may be due to loading oscillations. The welded elements are liable to internal discontinuities along welded joints and sensible to stress variations. The evaluation of the remaining life of a bridge is needed to make cost-effective decisions regarding inspection, repair, rehabilitation, and replacement. A steel beam model has been proposed to simulate crack openings due to cyclic loads. Two possible alternatives have been considered to model crack propagation, which the initial phase is based on the linear fracture mechanics. Then, the model is extended to take into account the elastoplastic fracture mechanic concepts. The natural frequency changes are directly related to moment of inertia variation and consequently to a reduction in the flexural stiffness of a steel beam. Thus, it is possible to adopt a nondestructive technique during steel bridge inspection to quantify the structure eigenvalue variation that will be used to localize the grown fracture. A damage detection algorithm is developed for the proposed model and the numerical results are compared with the solutions achieved by using another well know computer code.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chaotic behaviour is one of the hardest problems that can happen in nonlinear dynamical systems with severe nonlinearities. It makes the system's responses unpredictable. It makes the system's responses to behave similar to noise. In some applications it should be avoided. One of the approaches to detect the chaotic behaviour is nding the Lyapunov exponent through examining the dynamical equation of the system. It needs a model of the system. The goal of this study is the diagnosis of chaotic behaviour by just exploring the data (signal) without using any dynamical model of the system. In this work two methods are tested on the time series data collected from AMB (Active Magnetic Bearing) system sensors. The rst method is used to nd the largest Lyapunov exponent by Rosenstein method. The second method is a 0-1 test for identifying chaotic behaviour. These two methods are used to detect if the data is chaotic. By using Rosenstein method it is needed to nd the minimum embedding dimension. To nd the minimum embedding dimension Cao method is used. Cao method does not give just the minimum embedding dimension, it also gives the order of the nonlinear dynamical equation of the system and also it shows how the system's signals are corrupted with noise. At the end of this research a test called runs test is introduced to show that the data is not excessively noisy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new type of magnetic bearing with active control only in axial direction. The bearing uses two pairs of permanent magnets working in attraction mode to restrict the radial motion and a control system composed of two electromagnets, a gap sensor and a controller to keep the axis in a fixed axial position. The principle, the dynamic model for axial motion and the control system for this bearing are presented. Finally, by experiments conducted in a prototype, the effectiveness of the presented concept is shown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tässä diplomityössä kehitettiin yksitoimisten puristussylinterien valmistusta Rautessa. Sylinterien valmistuksessa haastavin vaihe on sylinteriputken ja pohjan välinen hitsaus. Hitsauksen avuksi suunniteltiin sylinterin sisäpuolinen juuritukilaite. Hitsauskokeita suoritettiin hitsin pohjan jauhekaarihitsaukselle ja MAG-hitsaukselle. Juuritukilaitteen toimivuutta testattiin koehitsauksilla. Puristussylinterien materiaali on S355J2-terästä, jonka ainevahvuus on 20 – 60 mm. Paksujen rakenneterästen hitsauksessa täytyy ottaa huomioon hitsausliitoksen mekaanisten ominaisuuksien muuttuminen sekä eri halkeamien synty. Hitsauksen laatuun ja laadunhallintaan voidaan vaikuttaa monien eri tekijöiden avulla. Hitsausohjeen avulla, ja muut laatutekijät huomioiden, voidaan hitseille asetetut laatukriteerit täyttää. Juurituen käyttö nopeuttaa puristussylinterien hitsausta vähintään 50 %. Jauhekaarihitsaus kuparista juuritukea vasten synnyttää vaikeasti poistettavan kuonan juuren puolelle. Perinteinen MAG-hitsaus kuparista juuritukea vasten sisältää liian monta muuttujaa, mikä tekee siitä epäluotettavan pohjapalon hitsaukseen. Työssä suunnitellun juuritukilaitteen käyttö tuotannossa vaatii lisää hitsauskokeita.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Growing demand for stainless steel construction materials has increased the popularity of substitutive materials for austenitic stainless steels. The lean duplex grades have taken their place in building of structures exposed to corrosive environments. Since the duplex grades are relatively new materials, the current codes and norms do not fully cover the newest duplex grades. The joints tested in this thesis were designed and studied according to Eurocode 3, even though all the materials are not yet accepted to the standards. The main objective in this thesis was to determine the differences of the used materials in behaviour under loading at low temperatures. Tests in which the deformation and strength properties of the joints were determined were done at the temperature of -46°C, which is the requirement of temperature for structures designed according to Norsok standards. Results show that replacing the austenitic grade with the lean duplex grade is acceptable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gas shielding plays an important role in laser welding phenomena. This is because it does not only provide shielding against oxidization but it has an effect in beam absorption and thus welds penetration. The goal of this thesis is to study and compare the effects of different shielding gas feeding methods in laser welding of steel. Research method is a literature survey. It is found that the inclination angle and the arrangement of the gas feeding nozzles affect the phenomena significantly. It is suggested that by designing shielding gas feeding case specifically better welding results can be obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interferometer for low resolution portable Fourier Transform middle infrared spectrometer was developed and studied experimentally. The final aim was a concept for a commercial prototype. Because of the portability, the interferometer should be compact sized and insensitive to the external temperature variations and mechanical vibrations. To minimise the size and manufacturing costs, Michelson interferometer based on plane mirrors and porch swing bearing was selected and no dynamic alignment system was applied. The driving motor was a linear voice coil actuator to avoid mechanical contact of the moving parts. The driving capability for low mirror driving velocities required by the photoacoustic detectors was studied. In total, four versions of such an interferometer were built and experimentally studied. The thermal stability during the external temperature variations and the alignment stability over the mirror travel were measured using the modulation depth of the wide diameter laser beam. Method for estimating the mirror tilt angle from the modulation depth was developed to take account the effect from the non-uniform intensity distribution of the laser beam. The spectrometer stability was finally studied also using the infrared radiation. The latest interferometer was assembled for the middle infrared spectrometer with spectral range from 750 cm−1 to 4500 cm−1. The interferometer size was (197 × 95 × 79) mm3 with the beam diameter of 25 mm. The alignment stability as the change of the tilt angle over the mirror travel of 3 mm was 5 μrad, which decreases the modulation depth only about 0.7 percent in infrared at 3000 cm−1. During the temperature raise, the modulation depth at 3000 cm−1 changed about 1 . . . 2 percentage units per Celsius over short term and even less than 0.2 percentage units per Celsius over the total temperature raise of 30 °C. The unapodised spectral resolution was 4 cm−1 limited by the aperture size. The best achieved signal to noise ratio was about 38 000:1 with commercially available DLaTGS detector. Although the vibration sensitivity requires still improving, the interferometer performed, as a whole, very well and could be further developed to conform all the requirements of the portable and stable spectrometer.