946 resultados para Constructed Wetlands


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives. To examine the effect of prolonged application time on the early and 3-year resin-dentin microtensile bond strength. Methods. Water/ethanol (Single Bond [SB]) and acetone-based systems (One Step [OS]) were employed. A flat superficial dentin surface was exposed in third human molars by wet abrasion. The adhesives were applied to a delimited area of 52 mm(2) on wet surfaces, for 40, 90, 150 and 300s. Four teeth were assigned for each experimental condition. Composite build-ups were constructed incrementally After water storage at 37 degrees C for 24 h, teeth were sectioned to obtain sticks with cross-sectional areas of 0.8 mm(2) to be tested in tension (0.5 mm/min) either immediately (IM) or after 3 years (3Y) of water storage. The microtensile bond strength (mu TBS) values were analyzed by two way repeated measures ANOVA and Tukey`s test (alpha = 0.05). Results. The 90- and 150-s groups achieved the highest IM mu TBS for OS (p < 0.01). For SB, the highest IM mu TBS values were observed after 300-s application (p < 0.01). Significant decreases in mu TBS were observed for OS in the 40- and 90-s groups after 3Y, except for the 150-s group. With regard to SB, after 3Y significant drops in mu TBS values were observed for the 40- and 150-s groups, except for the 300-s group. Significance. Prolonged application times can increase the immediate LTBS of two-step etch-and-rinse adhesive systems and make the adhesive layer more stable over time. (c) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. To determine the slow crack growth (SCG) and Weibull parameters of five dental ceramics: a vitreous porcelain (V), a leucite-based porcelain (D), a leucite-based glass-ceramic (E1), a lithium disilicate glass-ceramic (E2) and a glass-infiltrated alumina composite (IC). Methods. Eighty disks (empty set 12mm x 1.1mm thick) of each material were constructed according to manufacturers` recommendations and polished. The stress corrosion susceptibility coefficient (n) was obtained by dynamic fatigue test, and specimens were tested in biaxial flexure at five stress rates immersed in artificial saliva at 37 degrees C. Weibull parameters were calculated for the 30 specimens tested at 1MPa/s in artificial saliva at 37 degrees C. The 80 specimens were distributed as follows: 10 for each stress rate (10(-2), 10(-1), 10(1), 10(2) MPa/s), 10 for inert strength (10(2) MPa/s, silicon oil) and 30 for 10(0) MPa/s. Fractographic analysis was also performed to investigate the fracture origin. Results. E2 showed the lowest slow crack growth susceptibility coefficient (17.2), followed by D (20.4) and V (26.3). E1 and IC presented the highest n values (30.1 and 31.1, respectively). Porcelain V presented the lowest Weibull modulus (5.2). All other materials showed similar Weibull modulus values, ranging from 9.4 to 11.7. Fractographic analysis indicated that for porcelain D, glass-ceramics E1 and E2, and composite IC crack deflection was the main toughening mechanism. Significance. This study provides a detailed microstructural and slow crack growth characterization of widely used dental ceramics. This is important from a clinical standpoint to assist the clinician in choosing the best ceramic material for each situation as well as predicting its clinical longevity. It also can be helpful in developing new materials for dental prostheses. (c) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives. To determine the effect of ion exchange on slow crack growth (SCG) parameters (n, stress corrosion susceptibility coefficient, and sigma(f0), scaling parameter) and Weibull parameters (m, Weibull modulus, and sigma(0), characteristic strength) of a dental porcelain. Methods. 160 porcelain discs were fabricated according to manufacturer`s instructions, polished through 1 mu m and divided into two groups: GC (control) and GI (submitted to an ion exchange procedure using a KNO(3) paste at 470 degrees C for 15 min). SCG parameters were determined by biaxial flexural strength test in artificial saliva at 37 degrees C using five constant stress rates (n =10). 20 specimens of each group were tested at 1 MPa/s to determine Weibull parameters. The SPT diagram was constructed using the least-squares fit of the strength data versus probability of failure. Results. Mean values of m and sigma(0) (95% confidence interval), n and sigma(f0) (standard deviation) were, respectively: 13.8 (10.1-18.8) and 60.4 (58.5 - 62.2), 24.1 (2.5) and 58.1 (0.01) for GC and 7.4 (5.3 -10.0) and 136.8 (129.1-144.7), 36.7 (7.3) and 127.9 (0.01) for GI. Fracture stresses (MPa) calculated using the SPT diagram for lifetimes of 1 day, 1 year and 10 years (at a 5% failure probability) were, respectively, 31.8, 24.9 and 22.7 for GC and 71.2, 60.6 and 56.9 for GI. Significance. For the porcelain tested, the ion exchange process improved strength and resistance to SCG, however, the material`s reliability decreased. The predicted fracture stress at 5% failure probability for a lifetime of 10 years was also higher for the ion treated group. (C) 009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective was to compare fracture toughness (K(Ic)), stress corrosion susceptibility coefficient (n), and stress intensity factor threshold for crack propagation (K(I0)) of two porcelains [VM7/Vita (V) and d.Sign/Ivoclar (D)], two glass-ceramics [Empress/Ivolcar (E1) and Empress2/Ivlocar (E2)] and a glass-infiltrated alumina composite [In-Ceram Alumina/Vita (IC)]. Disks were constructed according to each manufacturer`s processing method, and polished before induction of cracks by a Vickers indenter. Crack lengths were measured under optical microscopy at times between 0.1 and 100 h. Specimens were stored in artificial saliva at 37A degrees C during the whole experiment. K(Ic) and n were determined using indentation fracture method. K(I0) was determined by plotting log crack velocity versus log K(I). Microstructure characterization was carried out under SEM, EDS, X-ray diffraction and X-ray fluorescence. IC and E2 presented higher K(Ic) and K(I0) compared to E1, V, and D. IC presented the highest n value, followed by E2, D, E1, and V in a decreasing order. V and D presented similar K(Ic), but porcelain V showed higher K(I0) and lower n compared to D. Microstructure features (volume fraction, size, aspect ratio of crystalline phases and chemical composition of glassy matrix) determined K(Ic). The increase of K(Ic) value favored the increases of n and K(I0).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This case report outlines the sequel and possible management of a permanent tooth traumatized through the predecessor, a maxillary right primary central incisor that was avulsed and replanted by a dentist 1 h after the trauma in a 3-year-old girl. Three years later, discoloration and fistula were present, so the primary tooth was extracted. The patient did not come to the scheduled follow-ups to perform a clinical and radiographic control of the succeeding permanent incisor, and only returned when she was 10 years old. At that moment, the impaction and dilaceration of the maxillary right permanent central incisor were observed through radiographic examination. The dilacerated permanent tooth was then surgically removed, and an esthetic fixed appliance was constructed with the crown of the extracted tooth. Positive psychological influence of the treatment on this patient was also observed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of oxalate during total-etch bonding, under different dentin moisture conditions, over time. The null hypothesis tested was that microtensile bond strength (mu TBS) was not affected by oxalate treatment and dentin moisture during two evaluation periods. Methods: Extracted human third molars had their mid-coronal dentin exposed flat and polished with 600-grit SiC paper. The surfaces were etched with 35% phosphoric acid for 15 seconds, washed and blot dried. After etching, a 3% potassium oxalate gel was applied for 120 seconds, except for the control group (no desensitizer). The surface was then washed and left moist (Wet bonding) or air-dried for 30 seconds (Dry bonding). The surfaces were bonded with: (I) two 2-step etch-and-rinse adhesives: Single Bond (SB); Prime & Bond NT (PBNT) and (2) one 3-step etch-and-rinse adhesive: Scotchbond Multi Purpose (SBMP). Composite buildups were constructed incrementally with Tetric Ceram resin composite. Each increment was cured for 40 seconds. After storage in water for 24 hours or 1 year at 37 C, the specimens were prepared for mu TBS testing with a cross-sectional area of approximately 1 mm(2). They were then tested in tension in an Instron machine at 0.5 mm/minute. Data were analyzed by ANOVA and Student-Newman-Keuls at alpha = 0.05. Results: Application of potassium oxalate had no significant effect on the bond strengths of SBMP and PBNT, regardless of the surface moisture condition (P > 0.05). Conversely, reduced bond strengths were observed after oxalate treatment for SB in both moisture conditions, that being significantly lower when using a dry-bonding procedure (P < 0.05). Lower bond strength was obtained for PBNT when a dry-bonding technique was used, regardless of the oxalate treatment (P < 0.05). After aging the specimens for 1 year, bond strengths decreased. Smaller reductions were observed for SBMP, regardless of moisture conditions. For the WB technique, smaller reductions after 1 year were observed without oxalate treatment for SB and after oxalate treatment for PBNT. (Am J Dent 2010;23:137-141).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. To evaluate the effects of surface moisture (wet or dry) and storage (24h or 3 months) on the microtensile bond strength (BS) of resin/dentin bonds mediated by two water/ethanol based adhesives Single Bond, 3M-ESPE, (SB) and Opti Bond Solo Plus, Kerr, (OB), and two acetone-based adhesives, One Step, Bisco, (OS) and Prime&Bond NT, Caulk/Dentsply, (PB). Materials and methods. Flat dentin surfaces were polished with 600-grit SiC paper, etched with 35% phosphoric acid for 15 s and rinsed for 20 s. Half the surface was maintained moist and the other half was air-dried for 30 s. Each adhesive was applied simultaneously to both halves, left undisturbed for 30 s and light-cured. Four-mm resin build-ups were constructed incrementally. After storage in water at 37 degrees C for 24h, slabs were produced by transversal sectioning and trimmed to an hourglass shape (0.8 mm 2). Half of the specimens were tested in tension at 0.6 mm/min immediately after trimming and the other half after 3 months of water storage. Data were analyzed by two-way ANOVA and SNK for each material. Results. Both moisture and storage affected BS to dentin, and was material- dependent. Dry, bonding affected mostly the acetone-based adhesives. Larger reductions in bond strength were associated with dry bonding after 3 months of water storage. Significance. Wet bonding resulted in more stable bonds over 3 months of water storage for most of the materials tested. (C) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Grobner bases have been generalised to polynomials over a commutative ring A in several ways. Here we focus on strong Grobner bases, also known as D-bases. Several authors have shown that strong Grobner bases can be effectively constructed over a principal ideal domain. We show that this extends to any principal ideal ring. We characterise Grobner bases and strong Grobner bases when A is a principal ideal ring. We also give algorithms for computing Grobner bases and strong Grobner bases which generalise known algorithms to principal ideal rings. In particular, we give an algorithm for computing a strong Grobner basis over a finite-chain ring, for example a Galois ring.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We consider the relation between the conditional moment closure (CMC) and the unsteady flamelet model (FM). The CMC equations were originally constructed as global equations, while FM was derived asymptotically for a thin reaction zone. The recent tendency is to use FM-type equations as global equations. We investigate the possible consequences and suggest a new version of FM: coordinate-invariant FM (CIFM). Unlike FM, CIFM complies with conditional properties of the exact transport equations which are used effectively in CMC. We analyse the assumptions needed to obtain another global version of FM: representative interactive flamelets (RIF), from original FM and demonstrate that, in homogeneous turbulence, one of these assumptions is equivalent to the main CMC hypothesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simulation of competitively primed allele-specific DNA amplification has been constructed and its behavior examined, This has shown that when the ratio of the amount of homoduplex misprime product to the total amount of amplimer is low, it increases by approximately one-fourth of the mispriming frequency with each doubling of the total amount of amplimer, When the ratio is high acid reverse mispriming becomes significant, it asymptotes toward a value

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ligaments undergo finite strain displaying hyperelastic behaviour as the initially tangled fibrils present straighten out, combined with viscoelastic behaviour (strain rate sensitivity). In the present study the anterior cruciate ligament of the human knee joint is modelled in three dimensions to gain an understanding of the stress distribution over the ligament due to motion imposed on the ends, determined from experimental studies. A three dimensional, finite strain material model of ligaments has recently been proposed by Pioletti in Ref. [2]. It is attractive as it separates out elastic stress from that due to the present strain rate and that due to the past history of deformation. However, it treats the ligament as isotropic and incompressible. While the second assumption is reasonable, the first is clearly untrue. In the present study an alternative model of the elastic behaviour due to Bonet and Burton (Ref. [4]) is generalized. Bonet and Burton consider finite strain with constant modulii for the fibres and for the matrix of a transversely isotropic composite. In the present work, the fibre modulus is first made to increase exponentially from zero with an invariant that provides a measure of the stretch in the fibre direction. At 12% strain in the fibre direction, a new reference state is then adopted, after which the material modulus is made constant, as in Bonet and Burton's model. The strain rate dependence can be added, either using Pioletti's isotropic approximation, or by making the effect depend on the strain rate in the fibre direction only. A solid model of a ligament is constructed, based on experimentally measured sections, and the deformation predicted using explicit integration in time. This approach simplifies the coding of the material model, but has a limitation due to the detrimental effect on stability of integration of the substantial damping implied by the nonlinear dependence of stress on strain rate. At present, an artificially high density is being used to provide stability, while the dynamics are being removed from the solution using artificial viscosity. The result is a quasi-static solution incorporating the effect of strain rate. Alternate approaches to material modelling and integration are discussed, that may result in a better model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The upper Paleozoic miospore genus Spelaeotriletes Neves and Owens, 1966 is reviewed as a morpho-taxonomic entity and vis-a-vis other similarly constructed (pseudosaccate) genera - Geminospora Balme, 1962, Grandispora Hoffmeister, Staplin, and Malloy, 1955, Rhabdosporites Richardson, 1960, and Retispora Staplin, 1960. Detailed studies of numerous, mainly topotype specimens of Spelaeotriletes ybertii (Marques-Toigo, 1970) Playford and Powis, 1979 from the Lower Permian of Uruguay result in its re-diagnosis, in conjunction with a survey of its exclusively Gondwanan occurrences, particularly in South American strata extending from the Upper Carboniferous (Westphalian) into the Lower Permian, and also in Australian strata of approximately equivalent age. The characteristics of other species of Spelaeotriletes reported from upper Paleozoic deposits of Gondwana are discussed, as are their temporal representations in various broad regions of the supercontinent (South America, North Africa, Australia). These species include two, perhaps three, that, like Spelaeotriletes triangulus/arenaceus, are known also from Euramerica - S. balteatus (Playford, 1963) Higgs, 1996, S. pretiosus (Playford, 1964) Utting, 1987, and possibly S. owensii Loboziak and Alpern, 1978. Other species, such as S. benghaziensis Loboziak and Clayton, 1988, S. giganteus Loboziak and Clayton, 1988, and S. vibrissus Playford and Satterthwait, 1988, have, on present knowledge, exclusively Gondwanan occurrences. S. queenslandensis Jones and Truswell. 1992, known only from Upper Carboniferous strata of northeastern Australia, is formally reassigned on sculptural grounds to Grandispora. Not unexpectedly in a paleogeographic perspective, North Africa and South America are more closely allied with each other than with Australia in terms of shared species of Spelaeotriletes. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Numerous everyday tasks require the nervous system to program a prehensile movement towards a target object positioned in a cluttered environment. Adult humans are extremely proficient in avoiding contact with any non-target objects (obstacles) whilst carrying out such movements. A number of recent studies have highlighted the importance of considering the control of reach-to-grasp (prehension) movements in the presence of such obstacles. The current study was constructed with the aim of beginning the task of studying the relative impact on prehension as the position of obstacles is varied within the workspace. The experimental design ensured that the obstacles were positioned within the workspace in locations where they did not interfere physically with the path taken by the hand when no obstacle was present. In all positions, the presence of an obstacle caused the hand to slow down and the maximum grip aperture to decrease. Nonetheless, the effect of the obstacle varied according to its position within the workspace. In the situation where an obstacle was located a small distance to the right of a target object, the obstacle showed a large effect on maximum grip aperture but a relatively small effect on movement time. In contrast, an object positioned in front and to the right of a target object had a large effect on movement speed but a relatively small effect on maximum grip aperture. It was found that the presence of two obstacles caused the system to decrease further the movement speed and maximum grip aperture. The position of the two obstacles dictated the extent to which their presence affected the movement parameters. These results show that the antic ipated likelihood of a collision with potential obstacles affects the planning of movement duration and maximum grip aperture in prehension.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Crum's notion of idola as a conceptual fallacy is interesting, somewhat helpful, yet potentially limiting in a critique of research in PE if one is to accept a postmodern or poststructuralist position. In line with a poststructuralist position, a strength in Crum's application of idola is the recognition that research in PE is constituted by the researcher and their social world which, in turn, constitutes the researcher. Limitations to Crum's idola thesis arise when the notion is used to suggest that as a result of the researcher's lack of conceptual clarity, the quest for knowledge or truth about PE pedagogy is undermined as this assumes that meanings can be unequivocal and precede a linear research process. In contrast, this response argues that a priority in research should be to examine how, and under what conditions, particular discourses come to shape PE practices in schools and universities. In a postmodern world, conceptual clarity should not be the goal but rather a coming to understand how PE knowledge and practice is being constructed across sites and contexts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Jembrana disease virus (JDV) is a newly isolated and characterised bovine lentivirus. It causes an acute disease in Ball cattle (Bos javanicus). which can be readily transmitted to susceptible cattle with 17% mortality. There is as yet no treatment or preventive vaccine. We have developed a gene transfer vector system based on JDV that has three components. The first of the components is a bicistronic transfer vector plasmid that was constructed to contain cis-sequences from the JDV genome, including 5 '- and 3 ' -long terminal repeats (LTRs), 0.4 kb of truncated gag and 1.1 kb of 3 ' -env, a multiple cloning site to accommodate the gene(s) of interest for transfer, and an internal ribosome entry site plus the neomycin phosphotransferase (Neo) gene cassette for antibiotic selection. The second element is a packaging plasmid that contains trans-sequences. including gag, pol. vif, tar and rev: but without the env and packaging signals. The third is a plasmid encoding the G glycoprotein of vesicular stomatitis virus (VSV-G) to supply the vector an envelope for pseudotyping. Cotransfection of 293T cells with these three plasmid components produced VSV-G pseudotyped. disabled, replication defective, bicistronic JDV vectors encoding the green fluorescent protein (EGFP) and the Neo resistance selection maker simultaneously with a titre range of (0.4-1.2) x 10(6) CFU/ml. Transduction of several replicating primary and transformed cells from cattle, primate and human sources and importantly growth-arrested cells with the JDV vectors showed high efficiency of EGFP gene transfer at 35-75%, which was stable and the expression of EGFP was long term. Furthermore, these JDV vectors were designed to suit the inclusion and expression of genes corresponding to JDV specific proteins, such as gag or env, for the development of vaccines for Jembrana disease. This strategy should also be applicable to other bovine diseases as wall. The design and construction of the JDV vector system should facilitate the study of the lentivirology and pathogenesis of the diseases associated with JDV or other bovine virus infections. To our knowledge, this is the first such vector system developed from a cattle virus. (C) 2001 Elsevier Science B.V. All rights reserved.