934 resultados para Compression-molding technique
Resumo:
[Décret. 1928-11-01]
Resumo:
Visual implant elastomer (VIE) has recently been employed to investigate different aspects of earthworm ecology. However, a number of fundamental questions relating to the detection and positioning of the tag, its persistence and potential effects on earthworms remain unknown. Seven earthworm species belonging to three ecological groupings, with different pigmentation and burrowing behaviour, were tagged using different coloured VIE. External inspection after two days, one week and 1, 10 and 27 months were followed by preservation, dissection and internal inspection. Tags could be seen in living specimens to 27 months, and dissection revealed that in most cases they were lodged in the coelomic cavity, held in place by septa. However, over longer time periods (more than two years), the chlorogogenous tissue tended to bind to the tags and made external observation increasingly difficult. Migration of the VIE material towards the posterior of the earthworm and potential loss of the tag were only observed on rare occasions, and a recovery rate in excess of 98% was recorded. By introducing a reasonable amount of VIE into segments, just after the clitellum, this technique can become a valuable tool in earthworm ecology and life history studies, particularly in short-medium term laboratory and field experiments.
Resumo:
OBJECTIVE: The aim of the current study was to investigate the biomechanical stability and fixation strength provided by a posterior approach reconstruction technique to realign the craniovertebral junction.¦METHODS: We tested seven human cadaver occipito-cervical spines (occiput-C4) by applying pure moments of ±1.5 Nm on a spine tester. Each specimen was tested in the following modes: 1) intact; 2) injured; 3) spacers alone at C1-C2 articulation (S); 4) spacers plus C1-C2 Posterior Instrumentation (S+PI); and 5) spacers plus C1-C2 posterior instrumentation plus midline wiring (S+PI+MLW). C1-C2 range of motion for each construct was obtained in flexion-extension, lateral bending, and axial rotation.¦RESULTS: In all the loading modes, S, S+PI, and S+PI+MLW constructs significantly reduced range of motion compared with the intact and injured condition (P < 0.05). There was no statistical difference between any of the three instrumentation constructs (P > 0.05).¦CONCLUSIONS: This study investigated the biomechanics of the posterior approach technique for realignment of the craniovertebral junction and also made comparisons with additional posterior fixations. The stand-alone spacers were stable in all three loading modes. Posterior instrumentation increased the stability as compared to stand-alone spacers. The third point of fixation, carried out by using midline wiring, increased the stability further. However, there was not much difference in the stability imparted with the midline wiring versus without. The present study highlights the biomechanics of this novel concept and reaffirms the view that distraction of the C1-C2 articular facets and direct articular joint atlantoaxial fixation would be an ideal method of management of basilar invagination.
Resumo:
The SeDeM Diagram Expert System has been used to study excipients, Captopril and designed formulations for their galenic characterization and to ascertain the critical points of the formula affecting product quality to obtain suitable formulations of Captopril Direct Compression SR Matrix Tablets. The application of the Sedem Diagram Expert System enables selecting excipients with in order to optimize the formula in the preformulation and formulation studies. The methodology is based on the implementation of ICH Q8, establishing the design space of the formula with the use of experiment design, using the parameters of the SeDeM Diagram Expert System as system responses.
Resumo:
Abstract
Resumo:
This paper aims to examine changes in common longevity and variability of the adult life span, and attempts to answer whether or not the compression of mortality continues in Switzerland in the years 1876-2005. The results show that the negative relationships between the large increase in the adult modal age at death, observed at least from the 1920s, and the decrease in the standard deviation of the ages at deaths occurring above it, illustrate a significant compression of adult mortality. Typical adult longevity increased by about 10% during the last fifty years in Switzerland, and adult heterogeneity in the age at death decreased in the same proportion. This analysis has not found any evidence suggesting that we are approaching longevity limits in term of modal or even maximum life spans. It ascertains a slowdown in the reduction of adult heterogeneity in longevity, already observed in Japan and other low mortality countries.
Resumo:
Direct MR arthrography has a better diagnostic accuracy than MR imaging alone. However, contrast material is not always homogeneously distributed in the articular space. Lesions of cartilage surfaces or intra-articular soft tissues can thus be misdiagnosed. Concomitant application of axial traction during MR arthrography leads to articular distraction. This enables better distribution of contrast material in the joint and better delineation of intra-articular structures. Therefore, this technique improves detection of cartilage lesions. Moreover, the axial stress applied on articular structures may reveal lesions invisible on MR images without traction. Based on our clinical experience, we believe that this relatively unknown technique is promising and should be further developed.
Resumo:
The objective of this study was to assess the efficiency of spiral CT (SCT) aortography for diagnosing acute aortic lesions in blunt thoracic trauma patients. Between October 1992 and June 1997, 487 SCT scans of the chest were performed on blunt thoracic trauma patients. To assess aortic injury, the following SCT criteria were considered: hemomediastinum, peri-aortic hematoma, irregular aspect of the aortic wall, aortic pseudodiverticulum, intimal flap and traumatic dissection. Aortic injury was diagnosed on 14 SCT examinations (2.9 %), five of the patients having had an additional digital aortography that confirmed the aortic trauma. Twelve subjects underwent surgical repair of the thoracic aorta, which in all but one case confirmed the aortic injury. Two patients died before surgery from severe brain lesions. The aortic blunt lesions were confirmed at autopsy. According to the follow-up of the other 473 patients, we are aware of no false-negative SCT examination. Our limited series shows a sensitivity of 100 % and specificity of 99.8 % of SCT aortography in the diagnosis of aortic injury. It is concluded that SCT aortagraphy is an accurate diagnostic method for the assessment of aortic injury in blunt thoracic trauma patients.
Resumo:
This paper describes an audio watermarking scheme based on lossy compression. The main idea is taken from an image watermarking approach where the JPEG compression algorithm is used to determine where and how the mark should be placed. Similarly, in the audio scheme suggested in this paper, an MPEG 1 Layer 3 algorithm is chosen for compression to determine the position of the mark bits and, thus, the psychoacoustic masking of the MPEG 1 Layer 3compression is implicitly used. This methodology provides with a high robustness degree against compression attacks. The suggested scheme is also shown to succeed against most of the StirMark benchmark attacks for audio.
Resumo:
Metallic foreign bodies are rarely found in the maxillary sinus, and usually they have a dental origin.Potential complications related to foreign bodies include recurrent sinusitis, rhinolith formation, cutaneous fistula,chemical poisoning, facial neuralgic pain and even malignancies.Two main surgical approaches are currently used for the removal of foreign bodies in the maxillary sinus: the bone flap and the endoscopic sinus techniques. We are reporting two unusual cases of large high-velocity foreign bodies removed by a modified maxillary lateral antrotomy,with free bone flap repositioning and fixation with a titanium miniplate.
Resumo:
Process variations are a major bottleneck for digital CMOS integrated circuits manufacturability and yield. That iswhy regular techniques with different degrees of regularity are emerging as possible solutions. Our proposal is a new regular layout design technique called Via-Configurable Transistors Array (VCTA) that pushes to the limit circuit layout regularity for devices and interconnects in order to maximize regularity benefits. VCTA is predicted to perform worse than the Standard Cell approach designs for a certain technology node but it will allow the use of a future technology on an earlier time. Ourobjective is to optimize VCTA for it to be comparable to the Standard Cell design in an older technology. Simulations for the first unoptimized version of our VCTA of delay and energy consumption for a Full Adder circuit in the 90 nm technology node are presented and also the extrapolation for Carry-RippleAdders from 4 bits to 64 bits.
Resumo:
Peer reviewed