968 resultados para CT scan
Resumo:
Purpose: To evaluate the diagnostic value and image quality of CT with filtered back projection (FBP) compared with adaptive statistical iterative reconstructed images (ASIR) in body stuffers with ingested cocaine-filled packets.Methods and Materials: Twenty-nine body stuffers (mean age 31.9 years, 3 women) suspected for ingestion of cocaine-filled packets underwent routine-dose 64-row multidetector CT with FBP (120kV, pitch 1.375, 100-300 mA and automatic tube current modulation (auto mA), rotation time 0.7sec, collimation 2.5mm), secondarily reconstructed with 30 % and 60 % ASIR. In 13 (44.83%) out of the body stuffers cocaine-filled packets were detected, confirmed by exact analysis of the faecal content including verification of the number (range 1-25). Three radiologists independently and blindly evaluated anonymous CT examinations (29 FBP-CT and 68 ASIR-CT) for the presence and number of cocaine-filled packets indicating observers' confidence, and graded them for diagnostic quality, image noise, and sharpness. Sensitivity, specificity, area under the receiver operating curve (ROC) Az and interobserver agreement between the 3 radiologists for FBP-CT and ASIR-CT were calculated.Results: The increase of the percentage of ASIR significantly diminished the objective image noise (p<0.001). Overall sensitivity and specificity for the detection of the cocaine-filled packets were 87.72% and 76.15%, respectively. The difference of ROC area Az between the different reconstruction techniques was significant (p= 0.0101), that is 0.938 for FBP-CT, 0.916 for 30 % ASIR-CT, and 0.894 for 60 % ASIR-CT.Conclusion: Despite the evident image noise reduction obtained by ASIR, the diagnostic value for detecting cocaine-filled packets decreases, depending on the applied ASIR percentage.
Resumo:
This paper proposes MSISpIC, a probabilistic sonar scan matching algorithm for the localization of an autonomous underwater vehicle (AUV). The technique uses range scans gathered with a Mechanical Scanning Imaging Sonar (MSIS), the robot displacement estimated through dead-reckoning using a Doppler velocity log (DVL) and a motion reference unit (MRU). The proposed method is an extension of the pIC algorithm. An extended Kalman filter (EKF) is used to estimate the robot-path during the scan in order to reference all the range and bearing measurements as well as their uncertainty to a scan fixed frame before registering. The major contribution consists of experimentally proving that probabilistic sonar scan matching techniques have the potential to improve the DVL-based navigation. The algorithm has been tested on an AUV guided along a 600 m path within an abandoned marina underwater environment with satisfactory results
Resumo:
Contexte : Les patients souffrant d'un épisode dépressif sévère sont fréquemment traités par des inhibiteurs sélectifs de la recapture de la sérotonine (SSRI). Cependant, seulement 30-50% des patients répondront à ce type de traitement. Actuellement, il n'existe pas de marqueur biologique utilisable pour prédire la réponse à un traitement par SSRI. Un délai dans la mise en place d'une thérapie efficace peut avoir comme conséquences néfastes une augmentation du risque de suicide et une association avec un moins bon pronostic à long terme lors d'épisodes ultérieurs. Objectif : Par l'étude du métabolisme cérébral par tomographie par émission de positons (PET) au F-18-fluorodeoxyglucose (FDG), nous étudierons la présence de corrélations éventuelles entre la réponse clinique, qui généralement survient dans les 4 à 6 semaines après l'instauration du traitement antidépresseur, et une modification du métabolisme cérébral mesuré plus précocement, dans le but d'identifier les futurs répondeurs au traitement par SSRI. Méthodes : Cette étude longitudinale comprendra 20 patients unipolaires avec un épisode dépressif sévère au bénéfice d'un traitement par SSRI. Chacun des patients aura deux examens PET cérébraux au F-18-FDG. Le premier PET aura lieu juste avant le début du traitement aux SSRI et le second dans la 3ème semaine après début du traitement. La réponse clinique sera mesurée à 3 mois, et les répondeurs seront identifiés par une diminution significative des scores lors d'évaluation sur échelles de dépression. La recherche d'altérations métaboliques cérébrales sera faite en évaluant: (1) l'examen de base ou (2) l'examen PET précoce, à la recherche d'altérations spécifiques corrélées à une bonne réponse clinique, afin d'obtenir une valeur pronostique quant à la réponse au traitement. L'analyse de l'imagerie cérébrale utilisera la technique SPM (Statistical Parameter Mapping) impliquant un traitement numérique voxel par voxel des images PET. Résultats escomptés : Cette étude caractérisant les variations du métabolisme cérébral dans la phase précoce d'un traitement par SSRI vise à identifier des marqueurs métaboliques potentiels fournissant une valeur prédictive quant à la future efficacité du traitement SSRI introduit. Plus-value escomptée : L'identification d'un tel marqueur métabolique permettrait d'identifier rapidement les futurs répondeurs aux SSRI, et par conséquent d'éviter de proposer aux non-répondeurs la poursuite d'une médication, pendant plusieurs semaines, qui aurait peu de chance d'être efficace. Ainsi, une identification précoce des répondeurs aux SSRI pourrait permettre d'éviter des délais dans la mise en place d'une thérapie efficace et d'obtenir une amélioration du pronostic à plus long terme, avec une influence favorable sur les coûts de la santé.
Resumo:
BACKGROUND: The Contegra® is a conduit made from the bovine jugular vein and then interposed between the right ventricle and the pulmonary artery. It is used for cardiac malformations in the reconstruction of right ventricular outflow tract. OBJECTIVE: To describe both normal and pathological appearances of the Contegra® in radiological imaging, to describe imaging of complications and to define the role of CT and MRI in postoperative follow-up. MATERIALS AND METHODS: Forty-three examinations of 24 patients (17 boys and 7 girls; mean age: 10.8 years old) with Contegra® conduits were reviewed. Anatomical description and measurements of the conduits were performed. Pathological items examined included stenosis, dilatation, plicature or twist, thrombus or vegetations, calcifications and valvular regurgitation. Findings were correlated to the echographic gradient through the conduit when available. RESULTS: CT and MR work-up showed Contegra® stenosis (n = 12), dilatation (n = 9) and plicature or twist (n = 7). CT displayed thrombus or vegetations in the Contegra® in three clinically infected patients. Calcifications of the conduit were present at CT in 12 patients and valvular regurgitation in three patients. The comparison between CT and/or MR results showed a good correlation between the echographic gradient and the presence of stenosis in the Contegra®. CONCLUSION: CT and MR bring additional information about permeability and postoperative anatomy especially when echocardiography is inconclusive. Both techniques depict the normal appearance of the conduit, and allow comparison and precise evaluation of changes in the postoperative follow-up.
Resumo:
BACKGROUND: Diffusion-weighted magnetic resonance imaging (MRI) is increasingly being used for assessing the treatment succes in oncology, but the real clinical value needs to evaluated by comparison with other, already established, metabolic imaging techniques. PURPOSE: To prospectively evaluate the clinical potential of diffusion-weighted MRI with apparent diffusion coefficient (ADC) mapping for gastrointestinal stromal tumor (GIST) response to targeted therapy compared with 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT). MATERIAL AND METHODS: Eight patients (mean age, 56 ± 11 years) known to have metastatic GIST underwent 18F-FDG PET/CT and MRI (T1Gd, DWI [b = 50,300,600], ADC mapping) simultaneously, before and after change in targeted therapy. MR and PET/CT examinations were first analyzed blindly. Second, PET/CT images were co-registered with T1Gd-MR images for lesion detection. Only 18F-FDG avid lesions were considered. Maximum standardized uptake value (SUVmax) and the corresponding minimum ADCmin were measured for the six largest lesions per patient, if any, on baseline and follow-up examinations. The relationship between changes in SUVmax and ADCmin was analyzed (Spearman's correlation). RESULTS: Twenty-four metastases (12 hepatic, 12 extra-hepatic) were compared on PET/CT and MR images. SUVmax decreased from 7.7 ± 8.1 g/mL to 5.5 ± 5.4 g/mL (P = 0.20), while ADCmin increased from 1.2 ± 0.3 × 10(-3)mm(2)/s to 1.5 ± 0.3 × 10(-3)mm(2)/s (P = 0.0002). There was a significant association between changes in SUVmax and ADCmin (rho = - 0.62, P = 0.0014), but not between changes in lesions size (P = 0.40). CONCLUSION: Changes in ADCmin correlated with the response of 18F-FDG avid GIST to targeted therapy. Thus, diffusion-weighted MRI may represent a radiation-free alternative for follow-up treatment for metastatic GIST patients.
Resumo:
Référence bibliographique : Rol, 55102
Resumo:
Forest fires are defined as uncontrolled fires often occurring in wildland areas, but that can also affect houses or agricultural resources. Causes are both natural (e.g.,lightning phenomena) and anthropogenic (human negligence or arsons).Major environmental factors influencing the fire ignition and propagation are climate and vegetation. Wildfires are most common and severe during drought period and on windy days. Moreover, under water-stress conditions, which occur after a long hot and dry period, the vegetation is more vulnerable to fire. These conditions are common in the United State and Canada, where forest fires represent a big problem. We focused our analysis on the state of Florida, for which a big dataset on forest fires detection is readily available. USDA Forest Service Remote Sensing Application Center, in collaboration with NASA-Goddard Space Flight Center and the University of Maryland, has compiled daily MODIS Thermal Anomalies (fires and biomass burning images) produced by NASA using a contextual algorithm that exploits the strong emission of mid-infrared radiation from fires. Fire classes were converted in GIS format: daily MODIS fire detections are provided as the centroids of the 1 kilometer pixels and compiled into daily Arc/INFO point coverage.
Resumo:
Postmortem angiography is becoming increasingly essential in forensic pathology as an adjunct to conventional autopsy. Despite the numerous advantages of this technique, some questions have been raised regarding the influence of the contrast agent injected on the results of toxicological and biochemical analyses. The aim of this study was to investigate the effect of the injection of the contrast agent Angiofil®, mixed with paraffin oil, on the results of postmortem biochemical investigations performed on vitreous humor. Postmortem biochemical investigations were performed on vitreous samples collected from bodies that had undergone postmortem angiography (n=50) and from a control group (n=50). Two vitreous samples were analyzed for each group and the results compared. Glucose, urea, creatinine, 3-β-hydroxybutyrate, sodium and chloride were tested. Different values were observed between the first and second samples in each group. However, these differences were not clinically relevant, suggesting that the injection of this contrast agent mixture does not modify the concentration of the analyzed substances in the vitreous humor.
Resumo:
Our objective was a prospective comparison of MR enteroclysis (MRE) with multidetector spiral-CT enteroclysis (MSCTE). Fifty patients with various suspected small bowel diseases were investigated by MSCTE and MRE. The MSCTE was performed using slices of 2.5 mm, immediately followed by MRE, obtaining T1- and T2-weighted sequences, including gadolinium-enhanced acquisition with fat saturation. Three radiologists independently evaluated MSCTE and MRE searching for 12 pathological signs. Interobserver agreement was calculated. Sensitivities and specificities resulted from comparison with pathological results ( n=29) and patient's clinical evolution ( n=21). Most pathological signs, such as bowel wall thickening (BWT), bowel wall enhancement (BWE) and lymphadenopathy (ADP), showed better interobserver agreement on MSCTE than on MRE (BWT: 0.65 vs 0.48; BWE: 0.51 vs 0.37; ADP: 0.52 vs 0.15). Sensitivity of MSCTE was higher than that of MRE in detecting BWT (88.9 vs 60%), BWE (78.6 vs 55.5%) and ADP (63.8 vs 14.3%). Wilcoxon signed-rank test revealed significantly better sensitivity of MSCTE than that of MRE for each observer ( p=0.028, p=0.046, p=0.028, respectively). Taking the given study design into account, MSCTE provides better sensitivity in detecting lesions of the small bowel than MRE, with higher interobserver agreement.
Resumo:
Objectif : Les épanchements pleuraux sont fréquents chez les patients porteurs de cancer et déterminer s'ils sont de nature tumorale ou non relève d'une grande importance clinique, particulièrement pour le groupe des carcinomes pulmonaires NON à petites cellules (NSCLC). Le PET/CT s'est montré d'une grande utilité et est actuellement indiscutablement reconnu comme outils nécessaire dans la prise en charge et notamment la stadification et le suivi des cancers, et particulièrement des cancers pulmonaires. Sa capacité à pouvoir distinguer les épanchements pleuraux malins des épanchements pleuraux non tumoraux, « bénins » n'est pas précisément connue et n'a pas jusqu'à présent été investiguée de manière approfondie. Matériel et méthodes : Nous avons examiné la captation du FDG (indice SUVmax) des épanchements pleuraux de 50 PET/CT réalisés chez 47 patients (29 hommes, 18 femmes, 60±16 ans) avec épanchements pleuraux et cancer connu (24 NSCLC, 7 lymphomes, 5 cancer du sein, 4 GIST, 3 mésothéliomes, 2 cancer ORL, 2 tératomes malins, 1 carcinome colorectal, 1 carcinome oesophagien, 1 mélanome). Ces résultats ont été corrélés aux résultats des examens cytopathologiques réalisés après ponction de ces mêmes épanchements dans un intervalle médian de 21 jours (interquartile range -3 to 23). L'examen du liquide d'épanchement comportait la mesure du pH, la distribution relative des différents éléments cellulaires (macrophages, neutrophils, éosinophiles, basophiles, lymphocytes, plasmocytes), la numération cellulaire et bien entendu présence de cellules tumorales. Résultats : Parmis les épanchements, 17 étaient malins (34%) (6 NSCLC, 5 lymphomes, 2 cancers mammaires, 2 mésothéliomes, 2 tératomes malins). Les SUV étaient plus élevés dans les épanchements malins que dans les épanchements bénins [3.7 (95%IC 1.8-5.6) vs. 1.7 g/ml (1.5-1.9), p = 0.001], avec une corrélation entre les épanchements malins et le SUV (coefficient de Spearman ρ = 0.50, p = 0.001). Il n'a pas été observé de corrélation entre aucun des autres paramètres cyptopathologiques ou radiologiques analysé (aire sous la courbe ROC 0.83 ± 0.06). En utilisant un seuil du SUV de 2.2-mg/l, 12 examens PET/CT étaient interprétés comme positifs and 38 comme négatifs avec une sensibilité et une spécificité, valeur prédictive positive et négative de 53%, 91%, 75% and 79% respectivement. Concernant le groupe des NSCLC seulement (n = 24), aire sous la courbe ROC était de 0.95 ± 0.04. Sept examens étaient considérés comme positifs et 17 comme négatifs avec une sensibilité, une spécificité, valeur prédictive positive et négative de 83%, 89%, 71 et 94% respectivement. Conclusion : Le PET/CT peut aider à différencier la nature bénigne ou maligne des épanchements avec une haute spécificité chez les patients avec tumeur connue, en particulier dans un contexte de carcinome NON à petites cellules.
Resumo:
Donateur : Reclus, Élisée (1830-1905)