916 resultados para COATED IMPLANTS
Resumo:
This study investigated the effects of the morphology and physicochemical properties of calcium phosphate (CaP) nanoparticles on osteogenesis. Two types of CaP nanoparticles were compared, namely amorphous calcium phosphate (ACP) nano-spheres (diameter: 9-13 nm) and poorly crystalline apatite (PCA) nano-needles (30-50 nm x 2-4 nm) that closely resemble bone apatite. CaP particles were spin-coated onto titanium discs and implants; they were evaluated in cultured mouse calvarial osteoblasts, as well as after implantation in rabbit femurs. A significant dependence of CaP coatings was observed in osteoblast-related gene expression (Runx2, Col1a1 and Spp1). Specifically, the PCA group presented an up-regulation of the osteospecific genes, while the ACP group suppressed the Runx2 and Col1a1 expression when compared to blank titanium substrates. Both the ACP and PCA groups presented a more than three-fold increase of calcium deposition, as suggested by Alizarin red staining. The removal torque results implied a slight tendency in favour of the PCA group. Different forms of CaP nanostructures presented different biologic differences; the obtained information can be used to optimize surface coatings on biomaterials. © 2013 IOP Publishing Ltd.
Resumo:
Breast implants are medical devices that are used to augment breast size or to reconstruct the breast following mastectomy or to correct a congenital abnormality. Breast implants consist of a silicone outer shell and a filler (most commonly silicone gel or saline). Approximately 5 to 10 million women worldwide have breast implants. Histomorphometric study to evaluate the biological tissue compatibility of silicone implants suitable for plastic surgery and the adverse effects and risks of this material. Thirty Wistar white rats received subcutaneous implants and the revestiment of silicone gel Silimed ®®, and randomized into six groups of five animals each, according to the type of implanted material and the time of sacrifice. Eight areas of 60.11mm2 corresponding to the obtained surgical pieces were analyzed, counting mesenchymal cells, eosinophils, and foreign body giant cells, observing an acceptable biocompatibility in all implants, for subsequent statistical analysis by Tukey test. Silicone gel showed inflammation slightly greater than for other groups, with tissue reactions varying from light to moderate, whose result was the formation of a fibrous capsule around the material, recognized by the organism as a foreign body. Despite frequent local complications and adverse outcomes, this research showed that the silicone and top layer presented an acceptable chronic inflammatory reaction, which did not significantly differ from the control group. In general, it is possible to affirm that silicone gel had acceptable levels of biocompatibility, confirmed the rare presence of foreign body giant cells, and when of the rupture, formed a fibrous capsule around the material, separating the material of the organism. © AVICENA 2013.
Resumo:
Thin films of the semiconductor NiO are deposited using a straightforward combination of simple and versatile techniques: the co-precipitation in aqueous media along with the dip- coating process. The obtained material is characterized by gravimetric/differential thermal analysis (TG-DTA) and X-ray diffraction technique. TG curve shows 30 % of total mass loss, whereas DTA indicates the formation of the NiO phase about 578 K (305 C). X-ray diffraction (XRD) data confirms the FCC crystalline phase of NiO, whose crystallinity increases with thermal annealing temperature. UV-Vis optical absorption measurements are carried out for films deposited on quartz substrate in order to avoid the masking of bandgap evaluation by substrate spectra overlapping. The evaluated bandgap is about 3.0 eV. Current-voltage (I-V) curves measured for different temperatures as well as the temperature-dependent resistivity data show typical semiconductor behavior with the resistivity increasing with the decreasing of temperature. The Arrhenius plot reveals a level 233 meV above the conduction band top, which was attributed to Ni2+ vacancy level, responsible for the p-type electrical nature of NiO, even in undoped samples. Light irradiation on the films leads to a remarkable behavior, because above bandgap light induced a resistivity increase, despite the electron-hole generation. This performance was associated with excitation of the Ni 2+ vacancy level, due to the proximity between energy levels. © 2012 Springer Science+Business Media New York.
Resumo:
Metallic nanoparticles (NPs) have been used to improve the sensibility of biosensors and bioassays either by enhancing radiative emission or inducing quenching process on fluorescent probes. The aim of this research was to study the interaction of silver and silver-pectin NPs with water-dispersed carboxyl-coated cadmium telluride (CdTe) quantum dots (QDs). Metallic NPs were observed to change the emission of these fluorophores through local field effects. In a solution-base platform, an increase of 82 % was observed for the CdTe emission due to the interaction of QDs and silver-pectin NPs. QDs interaction with silver NPs without pectin was also investigated and a smaller emission enhancement of 20 % was detected. We observed that the NPs' nature and QDs' surface charge and concentration are important parameters for NPs-QDs interaction. Moreover, the presence of the pectin polymer shows to be a key component to the observed fluorescence enhancement. © 2013 Springer Science+Business Media New York.
Resumo:
Dentists are often faced with extensively resorbed mandibular ridges with shallow buccal vestibule and high insertion of the mentalis muscle in relation to the crest of the ridge, causing the displacement of the prosthesis. Vestibuloplasty techniques aim at eliminating the muscle insertions, reposition the mucosa, and increase the area chapeável, giving more stability to the prosthesis. Among the techniques to deepen the vestibule are submucosal vestibuloplasties by secondary epithelialization and with mucosal and skin grafts. We will discuss vestibuloplasty by secondary epithelialization with emphasis on the so-called modified Kazanjian technique. This technique provides an appropriate result and does not require hospitalization, additional surgery at the donor, or prolonged periods without the use of prosthesis. © 2013 by Mutaz B. Habal, MD.
Resumo:
Objectives: To evaluate bone healing around dental implants with established osseointegration in experimental diabetes mellitus (DM) and insulin therapy by histomorphometric and removal torque analysis in a rat model. Materials and methods: A total of 80 male Wistar rats received a titanium implant in the tibiae proximal methaphysis. After a healing period of 60 days, the rats were divided into four groups of 20 animals each: a 2-month control group, sacrificed at time (group A), a diabetic group (group D), an insulin group (group I), and a 4-month control group (group C), subdivided half for removal torque and half for histomorphometric analysis. In the D and I groups the DM was induced by a single injection of 40 mg/kg body weight streptozotocin (STZ). Two days after DM induction, group I received subcutaneous doses of insulin twice a day, during 2 months. Groups C and D received only saline. Two months after induction of DM, the animals of groups D, C and I were sacrificed. The plasmatic levels of glucose (GPL) were monitored throughout the experiment. Evaluation of the percentages of bone-to-implant contact and bone area within the limits of the implant threads was done by histomorphometric and mechanical torque analysis. Data were analyzed by anova at significant level of 5%. Results: The GPL were within normal range for groups A, C and I and higher for group D. The means and standard deviations (SD) for histomorphometric bone area showed significant difference between group D (69.34 ± 5.00%) and groups C (78.20 ± 4.88%) and I (79.63 ± 4.97%). Related to bone-to-implant contact there were no significant difference between the groups D (60.81 + 6.83%), C (63.37 + 5.88%) and I (66.97 + 4.13%). The means and SD for removal torque showed that group D (12.91 ± 2.51 Ncm) was statistically lower than group I (17.10 ± 3.06 Ncm) and C (16.95 ± 5.39 Ncm). Conclusions: Diabetes mellitus impaired the bone healing around dental implants with established osseointegration because the results presented a lower percentage of bone area in group D in relation to groups C and I resulting in a lowest torque values for implant removal. Moreover, insulin therapy prevents the occurrence of bone abnormalities found in diabetic animals and osseointegration was not compromised. © 2012 John Wiley & Sons A/S.
Resumo:
Objectives: The purpose of this study was to evaluate the surfaces of commercially pure titanium (cp Ti) implants modified by laser beam (LS), without and with hydroxyapatite deposition by the biomimetic method (HAB), without (HAB) and with thermal treatment (HABT), and compare them with implants with surfaces modified by acid treatment (AS) and with machined surfaces (MS), employing topographical and biomechanics analysis. Methods: Forty-five rabbits received 75 implants. After 30, 60, and 90 days, the implants were removed by reverse torque and the surfaces were topographically analyzed. Results: At 30 days, statistically significant difference (P < 0.05) was observed among all the surfaces and the MS, between HAB/HABT and AS and between HAB and LS. At 60 days, the reverse torque of LS, HAB, HABT, and AS differed significantly from MS. At 90 days, difference was observed between HAB and MS. The microtopographic analysis revealed statistical difference between the roughness of LS, HAB, and HABT when compared with AS and MS. Conclusions: It was concluded that the implants LS, HAB, and HABT presented physicochemical and topographical properties superior to those of AS and MS and favored the osseointegration process in the shorter periods. In addition, HAB showed the best results when compared with other surfaces. © 2012 John Wiley & Sons A/S.
Resumo:
Purpose: The purpose of this study was to evaluate the effect of diamond-like carbon thin films doped and undoped with silver nanoparticles coating poly(methyl methacrylate) (PMMA) on Candida albicans biofilm formation. The control of biofilm formation is important to prevent oral diseases in denture users. Materials and Methods: Forty-five PMMA disks were obtained, finished, cleaned in an ultrasonic bath, and divided into three groups: Gc, no surface coating (control group); Gdlc, coated with diamond-like carbon film; and Gag, coated with diamond-like carbon film doped with silver nanoparticles. The films were deposited using a reactive magnetron sputtering system (physical vapor deposition process). The specimens were characterized by optical profilometry, atomic force microscopy, and Rutherford backscattering spectroscopy analyses that determined differences in chemical composition and morphological structure. Following sterilization of the specimens by γ-ray irradiation, C. albicans (ATCC 18804) biofilms were formed by immersion in 2 ml of Sabouraud dextrose broth inoculated with a standardized fungal suspension. After 24 hours, the number of colony forming units (cfu) per specimen was counted. Data concerning biofilm formation were analyzed using ANOVA and the Tukey test (p < 0.05). Results: C. albicans biofilm formation was significantly influenced by the films (p < 0.00001), reducing the number of cfu, while not affecting the roughness parameters (p > 0.05). The Tukey test showed no significant difference between Gdlc and Gag. Films deposited were extremely thin (∼50 nm). The silver particles presented a diameter between 60 and 120 nm and regular distribution throughout the film surface (to Gag). Conclusion: Diamond-like carbon films, doped or undoped with silver nanoparticles, coating the base of PMMA-based dentures could be an alternative procedure for preventing candidosis in denture users. © 2013 by the American College of Prosthodontists.
Resumo:
This study aimed to evaluate the osteointegration and genotoxic potential of a bioactive scaffold, composed of alumina and coated with hydroxyapatite and bioglass, after their implantation in tibias of rats. For this purpose, Wistar rats underwent surgery to induce a tibial bone defect, which was filled with the bioactive scaffolds. Histology analysis (descriptive and morphometry) of the bone tissue and the single-cell gel assay (comet) in multiple organs (blood, liver, and kidney) were used to reach this aim after a period of 30, 60, 90, and 180 days of material implantation. The main findings showed that the incorporation of hydroxyapatite and bioglass in the alumina scaffolds produced a suitable environment for bone ingrowth in the tibial defects and did not demonstrate any genotoxicity in the organs evaluated in all experimental periods. These results clearly indicate that the bioactive scaffolds used in this study present osteogenic potential and still exhibit local and systemic biocompatibility. These findings are promising once they convey important information about the behavior of this novel biomaterial in biological system and highlight its possible clinical application. © 2013 Wiley Periodicals, Inc.
Resumo:
Purpose: This study compared the biomechanical behavior of tilted long implant and vertical short implants to support fixed prosthesis in an atrophic maxilla. Materials and Methods: The maxilla model was built based on a tomographic image of the patient. Implant models were based on micro-computer tomography imaging of implants. The different configurations considered were M4S, four vertical anterior implants; M4T, two mesial vertical implants and two distal tilted (45°) implants in the anterior region of the maxilla; and M6S, four vertical anterior implants and two vertical posterior implants. Numerical simulation was carried out under bilateral 150N loads applied in the cantilever region in axial (L1) and oblique (45°) (L2) direction. Bone was analyzed using the maximum and minimum principal stress (σmax and σmin), and von Mises stress (σvM) assessments. Implants were analyzed using the σvM. Results: The higher σmax was observed at: M4T, followed by M6S/L1, M6S/L2, M4S/L2, and M4S/L1 and the higher σvM: M4T/L1, M4T/L2 and M4S/L2, M6S/L2, M4S/L1, and M6S/L1. Conclusions: The presence of distal tilted (all-on-four) and distal short implants (all-on-six) resulted in higher stresses in both situations in the maxillary bone in comparison to the presence of vertical implants (all-on-four). © 2013 Wiley Periodicals, Inc.
Resumo:
Tribocorrosion plays an important role in the lifetime of metallic implants. Once implanted, biomaterials are subjected to micro-movements in aggressive biological fluids. Titanium is widely used as an implant material because it spontaneously forms a compact and protective nanometric thick oxide layer, mainly TiO2, in ambient air. That layer provides good corrosion resistance, and very low toxicity, but its low wear resistance is a concern. In this work, an anodizing treatment was performed on commercial pure titanium to form a homogeneous thick oxide surface layer in order to provide bioactivity and improve the biological, chemical and mechanical properties. Anodizing was performed in an electrolyte containing β-glycerophosphate and calcium acetate. The influence of the calcium acetate content on the tribocorrosion behaviour of the anodized material was studied. The concentration of calcium acetate in the electrolyte was found to largely affect the crystallographic structure of the resulting oxide layer. Better tribocorrosion behaviour was noticed on increasing the calcium acetate concentration. © 2013 IOP Publishing Ltd.
Resumo:
The aimof this study was to evaluate the stress distribution on bone tissue with a single prosthesis supported by implants of large and conventional diameter and presenting different veneering materials using the 3-D finite elementmethod. Sixteenmodels were fabricated to reproduce a bone block with implants, using two diameters (3.75 × 10 mmand 5.00 × 10 mm), four different veneering materials (composite resin, acrylic resin, porcelain, and NiCr crown), and two loads (axial (200 N) and oblique (100 N)). For data analysis, the maximum principal stress and vonMises criterion were used. For the axial load, the cortical bone in allmodels did not exhibit significant differences, and the trabecular bone presented higher tensile stresswith reduced implant diameter. For the oblique load, the cortical bone presented a significant increase in tensile stress on the same side as the loading for smaller implant diameters. The trabecular bone showed a similar but more discreet trend. There was no difference in bone tissue with different veneering materials. The veneering material did not influence the stress distribution in the supporting tissues of single implant-supported prostheses. The large-diameter implants improved the transference of occlusal loads to bone tissue and decreased stress mainly under oblique loads.Oblique loading was more detrimental to distribution stresses than axial loading. © 2013 Elsevier B.V. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Reabilitação Oral - FOAR