904 resultados para Barriers of use


Relevância:

90.00% 90.00%

Publicador:

Resumo:

A recent analysis of more than 100 countries found that the extent to which their languages grammatically allowed for an asymmetric treatment of men and women correlated with socio-economic indices of gender inequality (Prewitt-Freilino, Caswell, & Laakso, 2012). In a set of four studies we examine whether the availability of feminine forms as indicated by the most recent dictionaries (1) predicts the actual percentage of women and gender wage gap for all professions registered in Poland; (2) predicts the longitudinal pattern of use of the occupational job-titles; (3) relates to social perception of the sample of 150 professions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Tajikistan is particularly exposed to the risks of climate change. Its widely degraded landscapes are badly prepared to cope with changes in precipitation patterns, increased temperatures, droughts, and the spread of pests and disease. Sustainable land management (SLM) provides a “basket of opportunities” to address these challenges, particularly for increasing land productivity, improving livelihoods, and protecting ecosystems. Within the Pilot Program for Climate Resilience (PPCR) in Tajikistan 70 SLM technologies and approaches on how to implement SLM were documented with the World Overview of Conservation Approaches and Technologies (WOCAT ) tools in 2011. For this purpose a climate change adaptation module was developed and tested in order to enhance the understanding about climate change resilience of SLM practices and community workshops conducted to on adaptation mechanisms by rural communities in Tajikistan. The analysis came up with four guiding principles for applying SLM for adapting to climate change: 1. Diversification of land use technologies and farm incomes; 2. Intensification of use of natural resources; 3. Expansion of highly productive land use technologies; 4. Protection of land and livelihoods from extreme weather events. Furthermore, SLM must be up-scaled from isolated plots to entire zones or landscapes and the project developed the concept of three concentric villages zones, the in-, near- and off-village zones. Land users, advisors, and decision- and policy makers face the task of finding management practices that best suit site-specific conditions. This task is most efficiently addressed in collaborative effort, and building up and managing a respective knowledge platform.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

he UV spectrum of the adenine analogue 9-methyl-2-aminopurine (9M-2AP) is investigated with one- and two-color resonant two-photon ionization spectroscopy at 0.3 and 0.05 cm−1 resolution in a supersonic jet. The electronic origin at 32 252 cm−1 exhibits methyl torsional subbands that originate from the 0A′′1 (l = 0) and 1E ″ (l = ±1) torsional levels. These and further torsional bands that appear up to 000+230 cm−1 allow to fit the threefold (V 3) barriers of the torsional potentials as ∣∣V′′3∣∣=50 cm−1 in the S 0 and ∣∣V′3∣∣=126 cm−1 in the S 1 state. Using the B3LYP density functional and correlated approximate second-order coupled cluster CC2 methods, the methyl orientation is calculated to be symmetric relative to the 2AP plane in both states, with barriers of V′′3=20 cm−1 and V′3=115 cm−1. The 000 rotational band contour is 75% in-plane (a/b) polarized, characteristic for a dominantly long-axis 1ππ* excitation. The residual 25% c-axis polarization may indicate coupling of the 1ππ* to the close-lying 1 nπ* state, calculated at 4.00 and 4.01 eV with the CC2 method. However, the CC2 calculated 1 nπ oscillator strength is only 6% of that of the 1ππ* transition. The 1ππ* vibronic spectrum is very complex, showing about 40 bands within the lowest 500 cm−1. The methyl torsion and the low-frequency out-of-plane ν′1 and ν′2 vibrations are strongly coupled in the 1ππ* state. This gives rise to many torsion-vibration combination bands built on out-of-plane fundamentals, which are without precedence in the 1ππ* spectrum of 9H-2-aminopurine [S. Lobsiger, R. K. Sinha, M. Trachsel, and S. Leutwyler, J. Chem. Phys.134, 114307 (2011)]. From the Lorentzian broadening needed to fit the 000 contour of 9M-2AP, the 1ππ* lifetime is τ ⩾ 120 ps, reflecting a rapid nonradiative transition.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Endotoxemia from sepsis can injure the gastrointestinal tract through mechanisms that have not been fully elucidated. We have shown that LPS induces an increase in gastric permeability in parallel with the luminal appearance of secretory phospholipase A2 (sPLA2) and its product, lysophosphatidylcholine (lyso-PC). We proposed that sPLA2 acted on the gastric hydrophobic barrier, composed primarily of phosphatidylcholine (PC), to degrade it and produce lyso-PC, an agent that is damaging to the mucosa. In the present study, we have tested whether lyso-PC and/or sPLA2 have direct damaging effects on the hydrophobic barriers of synthetic and mucosal surfaces. Rats were administered LPS (5 mg/kg, i.p.), and gastric contents were collected 5 h later for analysis of sPLA2 and lyso-PC content. Using these measured concentrations, direct effects of sPLA2 and lyso-PC were determined on (a) surface hydrophobicity as detected with an artificial PC surface and with intact gastric mucosa (contact angle analysis) and (b) cell membrane disruption of gastric epithelial cells (AGS). Both lyso-PC and sPLA2 increased significantly in the collected gastric juice of LPS-treated rats. Using similar concentrations to the levels in gastric juice, the contact angle of PC-coated slides declined after incubation with either pancreatic sPLA2 or lyso-PC. Similarly, gastric contact angles seen in control rats were significantly decreased in sPLA2 and lyso-PC-treated rats. In addition, we observed dose-dependent injurious effects of both lyso-PC and sPLA2 in gastric AGS cells. An LPS-induced increase in sPLA2 activity in the gastric lumen and its product, lyso-PC, are capable of directly disrupting the gastric hydrophobic layer and may contribute to gastric barrier disruption and subsequent inflammation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Large field studies of travelers' diarrhea for multiple destinations are limited by the need to perform stool cultures on site in a timely manner. A method for the collection, transport, and storage of fecal specimens that does not require immediate processing and refrigeration and that is stable for months would be advantageous. This study was designed to determine if enterotoxigenic Escherichia coli (ETEC) and enteroaggregative E. coli (EAEC) DNA could be identified from cards that were processed for the evaluation of fecal occult blood. U.S. students traveling to Mexico during 2005 to 2007 were monitored for the occurrence of diarrheal illness. When ill, students provided a stool specimen for culture and occult blood by the standard methods. Cards then were stored at room temperature prior to DNA extraction. Fecal PCR was performed to identify ETEC and EAEC in DNA extracted from stools and from occult blood cards. Significantly more EAEC cases were identified by PCR that was performed on DNA that was extracted from cards (49%) or from frozen feces (40%) than from culture methods that used HEp-2 adherence assays (13%) (P < 0.001). Similarly, more ETEC cases were detected from card DNA (38%) than from fecal DNA (30%) or by culture that was followed by hybridization (10%) (P < 0.001). The sensitivity and specificity of the card test were 75 and 62%, respectively, compared to those for EAEC by culture and were 50 and 63%, respectively, compared to those for ETEC. DNA extracted from fecal cards that was used for the detection of occult blood is of use in identifying diarrheagenic E. coli.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND The majority of radiological reports are lacking a standard structure. Even within a specialized area of radiology, each report has its individual structure with regards to details and order, often containing too much of non-relevant information the referring physician is not interested in. For gathering relevant clinical key parameters in an efficient way or to support long-term therapy monitoring, structured reporting might be advantageous. OBJECTIVE Despite of new technologies in medical information systems, medical reporting is still not dynamic. To improve the quality of communication in radiology reports, a new structured reporting system was developed for abdominal aortic aneurysms (AAA), intended to enhance professional communication by providing the pertinent clinical information in a predefined standard. METHODS Actual state analysis was performed within the departments of radiology and vascular surgery by developing a Technology Acceptance Model. The SWOT (strengths, weaknesses, opportunities, and threats) analysis focused on optimization of the radiology reporting of patients with AAA. Definition of clinical parameters was achieved by interviewing experienced clinicians in radiology and vascular surgery. For evaluation, a focus group (4 radiologists) looked at the reports of 16 patients. The usability and reliability of the method was validated in a real-world test environment in the field of radiology. RESULTS A Web-based application for radiological "structured reporting" (SR) was successfully standardized for AAA. Its organization comprises three main categories: characteristics of pathology and adjacent anatomy, measurements, and additional findings. Using different graphical widgets (eg, drop-down menus) in each category facilitate predefined data entries. Measurement parameters shown in a diagram can be defined for clinical monitoring and be adducted for quick adjudications. Figures for optional use to guide and standardize the reporting are embedded. Analysis of variance shows decreased average time required with SR to obtain a radiological report compared to free-text reporting (P=.0001). Questionnaire responses confirm a high acceptance rate by the user. CONCLUSIONS The new SR system may support efficient radiological reporting for initial diagnosis and follow-up for AAA. Perceived advantages of our SR platform are ease of use, which may lead to more accurate decision support. The new system is open to communicate not only with clinical partners but also with Radiology Information and Hospital Information Systems.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Administration of cross-sex hormones to male-to-female transsexual subjects, usually oestrogens + often anti-androgens, such as cyproterone acetate, carries a risk of venous thromboembolism (VTE). VTE usually occurs in the first year of oestrogen administration. Ethinyl oestradiol, due to its chemical structure, was in 2003 identified as a major factor in the occurrence of VTE. Most clinics do not prescribe ethinyl oestradiol any longer, but people who take hormones without medical supervision use often oral contraceptives containing ethinyl oestradiol, many times in overdose. Cessation of use of ethinyl oestradiol and peri-operative thrombosis prophylaxis for surgery have reduced prevalence rate of VTE. Other oral oestrogens should not be overdosed, and transdermal oestrogen is to be preferred. Thrombosis prophylaxis for surgery is mandatory. It seems advisable to stop hormone use at least 2 weeks before major surgery, to be resumed only after 3 weeks following full mobilisation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Adolescent development includes changes in the biological regulatory processes for the timing of sleep. Circadian rhythm changes and changes to the sleep-pressure system (sleep homeostasis) during adolescence both favor later timing of sleep. These changes, combined with prevailing social pressures, are responsible for most teens sleeping too late and too little; those who sleep least report consuming more caffeine. Although direct research findings are scarce, the likelihood of use and abuse of caffeine-laden products grows across the adolescent years due, in part, to excessive sleepiness

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND Many studies have measured the intensity of end of life care. However, no summary of the measures used in the field is currently available. OBJECTIVES To summarise features, characteristics of use and reported validity of measures used for evaluating intensity of end of life care. METHODS This was a systematic review according to PRISMA guidelines. We performed a comprehensive literature search in Ovid Medline, Embase, The Cochrane Library of Systematic Reviews and reference lists published between 1990-2014. Two reviewers independently screened titles, abstracts, full texts and extracted data. Studies were eligible if they used a measure of end of life care intensity, defined as all quantifiable measures describing the type and intensity of medical care administered during the last year of life. RESULTS A total of 58 of 1590 potentially eligible studies met our inclusion criteria and were included. The most commonly reported measures were hospitalizations (n = 44), intensive care unit admissions (n = 39) and chemotherapy use (n = 27). Studies measured intensity of care in different timeframes ranging from 48 hours to 12 months. The majority of studies were conducted in cancer patients (n = 31). Only 4 studies included information on validation of the measures used. None evaluated construct validity, while 3 studies considered criterion and 1 study reported both content and criterion validity. CONCLUSIONS This review provides a synthesis to aid in choosing intensity of end of life care measures based on their previous use but simultaneously highlights the crucial need for more validation studies and consensus in the field.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background Complementary medicine (CM) is popular in Switzerland. Several CM methods (traditional Chinese medicine/acupuncture, homeopathy, anthroposophic medicine, neural therapy, and herbal medicine) are currently covered by the mandatory basic health insurance when performed by a certified physician. Treatments by non-medical therapists are partially covered by a supplemental and optional health insurance. In this study, we investigated the frequency of CM use including the evolvement over time, the most popular methods, and the user profile. Methods Data of the Swiss Health Surveys 2007 and 2012 were used. In 2007 and 2012, a population of 14,432 and 18,357, respectively, aged 15 years or older answered the written questionnaire. A set of questions queried about the frequency of use of various CM methods within the last 12 months before the survey. Proportions of usage and 95% confidence intervals were calculated for these methods and CM in general. Users and non-users of CM were compared using logistic regression models. Results The most popular methods in 2012 were homeopathy, naturopathy, osteopathy, herbal medicine, and acupuncture. The average number of treatments within the 12 months preceding the survey ranged from 3 for homeopathy to 6 for acupuncture. 25.0% of the population at the age of 15 and older had used at least one CM method in the previous 12 months. People with a chronic illness or a poor self-perceived health status were more likely to use CM. Similar to other countries, women, people of middle age, and those with higher education were more likely to use CM. 59.9% of the adult population had a supplemental health insurance that partly covered CM treatments. Conclusions Usage of CM in Switzerland remained unchanged between 2007 and 2012. The user profile in Switzerland was similar to other countries, such as Germany, United Kingdom, United States or Australia.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVES Oxygenation of blood and other physiological solutions are routinely required in fundamental research for both in vitro and in vivo experimentation. However, very few oxygenators with suitable priming volumes (<2-3 ml) are available for surgery in small animals. We have designed a new, miniaturized membrane oxygenator and investigated the oxygen-transfer performance using both buffer and blood perfusates. METHODS The mini-oxygenator was designed with a central perforated core-tube surrounded by parallel-oriented microporous polypropylene hollow fibres, placed inside a hollow shell with a lateral-luer outlet, and sealed at both extremities. With this design, perfusate is delivered via the core-tube to the centre of the mini-oxygenator, and exits via the luer port. A series of mini-oxygenators were constructed and tested in an in vitro perfusion circuit by monitoring oxygen transfer using modified Krebs-Henseleit buffer or whole porcine blood. Effects of perfusion pressure and temperature over flows of 5-60 ml × min(-1) were assessed. RESULTS Twelve mini-oxygenators with a mean priming volume of 1.5 ± 0.3 ml were evaluated. With buffer, oxygen transfer reached a maximum of 14.8 ± 1.0 ml O2 × l(-1) (pO2: 450 ± 32 mmHg) at perfusate flow rates of 5 ml × min(-1) and decreased with an increase in perfusate flow to 7.8 ± 0.7 ml ml O2 × l(-1) (pO2: 219 ± 24 mmHg) at 60 ml × min(-1). Similarly, with blood perfusate, oxygen transfer also decreased as perfusate flow increased, ranging from 33 ± 5 ml O2 × l(-1) at 5 ml × min(-1) to 11 ± 2 ml O2 × l(-1) at 60 ml × min(-1). Furthermore, oxygen transfer capacity remained stable with blood perfusion over a period of at least 2 h. CONCLUSIONS We have developed a new miniaturized membrane oxygenator with an ultra-low priming volume (<2 ml) and adequate oxygenation performance. This oxygenator may be of use in overcoming current limitations in equipment size for effective oxygenation in low-volume perfusion circuits, such as small animal extracorporeal circulation and ex vivo organ perfusion.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Gebiet: Chirurgie Biomedizintechnik Biophysik Transplantationsmedizin Kardiologie Abstract: OBJECTIVES: – Oxygenation of blood and other physiological solutions are routinely required in fundamental research for both in vitro and in vivo experimentation. However, very few oxygenators with suitable priming volumes (<2-3 ml) are available for surgery in small animals. We have designed a new, miniaturized membrane oxygenator and investigated the oxygen-transfer performance using both buffer and blood perfusates. – – METHODS: – The mini-oxygenator was designed with a central perforated core-tube surrounded by parallel-oriented microporous polypropylene hollow fibres, placed inside a hollow shell with a lateral-luer outlet, and sealed at both extremities. With this design, perfusate is delivered via the core-tube to the centre of the mini-oxygenator, and exits via the luer port. A series of mini-oxygenators were constructed and tested in an in vitro perfusion circuit by monitoring oxygen transfer using modified Krebs-Henseleit buffer or whole porcine blood. Effects of perfusion pressure and temperature over flows of 5-60 ml × min(-1) were assessed. – – RESULTS: – Twelve mini-oxygenators with a mean priming volume of 1.5 ± 0.3 ml were evaluated. With buffer, oxygen transfer reached a maximum of 14.8 ± 1.0 ml O2 × l(-1) (pO2: 450 ± 32 mmHg) at perfusate flow rates of 5 ml × min(-1) and decreased with an increase in perfusate flow to 7.8 ± 0.7 ml ml O2 × l(-1) (pO2: 219 ± 24 mmHg) at 60 ml × min(-1). Similarly, with blood perfusate, oxygen transfer also decreased as perfusate flow increased, ranging from 33 ± 5 ml O2 × l(-1) at 5 ml × min(-1) to 11 ± 2 ml O2 × l(-1) at 60 ml × min(-1). Furthermore, oxygen transfer capacity remained stable with blood perfusion over a period of at least 2 h. – – CONCLUSIONS: – We have developed a new miniaturized membrane oxygenator with an ultra-low priming volume (<2 ml) and adequate oxygenation performance. This oxygenator may be of use in overcoming current limitations in equipment size for effective oxygenation in low-volume perfusion circuits, such as small animal extracorporeal circulation and ex vivo organ perfusion. – – © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE To determine efficacy of a single intra-articular injection of an autologous platelet concentrate for treatment of osteoarthritis in dogs. DESIGN Randomized, controlled, 2-center clinical trial. ANIMALS 20 client-owned dogs with osteoarthritis involving a single joint. PROCEDURES Dogs were randomly assigned to a treatment or control group. In all dogs, severity of lameness and pain was scored by owners with the Hudson visual analog scale and the University of Pennsylvania Canine Brief Pain Inventory, respectively, and peak vertical force (PVF) was determined with a force platform. Dogs in the treatment group were then sedated, and a blood sample (55 mL) was obtained. Platelets were recovered by means of a point-of-use filter and injected intra-articularly within 30 minutes. Control dogs were sedated and given an intra-articular injection of saline (0.9% NaCl) solution. Assessments were repeated 12 weeks after injection of platelets or saline solution. RESULTS Dogs weighed between 18.3 and 63.9 kg (40.3 and 140.6 lb) and ranged from 1.5 to 8 years old. For control dogs, lameness scores, pain scores, and PVF at week 12 were not significantly different from pretreatment values. In contrast, for dogs that received platelet injections, lameness scores (55% decrease in median score), pain scores (53% decrease in median score), and PVF (12% increase in mean PVF) were significantly improved after 12 weeks, compared with pretreatment values. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that a single intra-articular injection of autologous platelets resulted in significant improvements at 12 weeks in dogs with osteoarthritis involving a single joint.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND The blood-cerebrospinal fluid barrier (BCSFB) established by the choroid plexus (CP) epithelium has been recognized as a potential entry site of immune cells into the central nervous system during immunosurveillance and neuroinflammation. The location of the choroid plexus impedes in vivo analysis of immune cell trafficking across the BCSFB. Thus, research on cellular and molecular mechanisms of immune cell migration across the BCSFB is largely limited to in vitro models. In addition to forming contact-inhibited epithelial monolayers that express adhesion molecules, the optimal in vitro model must establish a tight permeability barrier as this influences immune cell diapedesis. METHODS We compared cell line models of the mouse BCSFB derived from the Immortomouse(®) and the ECPC4 line to primary mouse choroid plexus epithelial cell (pmCPEC) cultures for their ability to establish differentiated and tight in vitro models of the BCSFB. RESULTS We found that inducible cell line models established from the Immortomouse(®) or the ECPC4 tumor cell line did not express characteristic epithelial proteins such as cytokeratin and E-cadherin and failed to reproducibly establish contact-inhibited epithelial monolayers that formed a tight permeability barrier. In contrast, cultures of highly-purified pmCPECs expressed cytokeratin and displayed mature BCSFB characteristic junctional complexes as visualized by the junctional localization of E-cadherin, β-catenin and claudins-1, -2, -3 and -11. pmCPECs formed a tight barrier with low permeability and high electrical resistance. When grown in inverted filter cultures, pmCPECs were suitable to study T cell migration from the basolateral to the apical side of the BCSFB, thus correctly modelling in vivo migration of immune cells from the blood to the CSF. CONCLUSIONS Our study excludes inducible and tumor cell line mouse models as suitable to study immune functions of the BCSFB in vitro. Rather, we introduce here an in vitro inverted filter model of the primary mouse BCSFB suited to study the cellular and molecular mechanisms mediating immune cell migration across the BCSFB during immunosurveillance and neuroinflammation.