952 resultados para Adulterated samples


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new polymeric coating consisting of a dual-phase, polydimethylsiloxane (PDMS) and polypyrrole (PPY) was developed for the stir bar sorptive extraction (SBSE) of antidepressants (mirtazapine, citalopram, paroxetine, duloxetine, fluoxetine and sertraline) from plasma samples, followed by liquid chromatography analysis (SBSE/LC-UV). The extractions were based on both adsorption (PPY) and sorption (PDMS) mechanisms. SBSE variables, such as extraction time, temperature, pH of the matrix, and desorption time were optimized, in order to achieve suitable analytical sensitivity in a short time period. The PDMS/PPY coated stir bar showed high extraction efficiency (sensitivity and selectivity) toward the target analytes. The quantification limits (LOQ) of the SBSE/LC-UV method ranged from 20 ng mL(-1) to 50 ng mL(-1), and the linear range was from LOQ to 500 ng mL(-1), with a determination coefficient higher than 0.99. The inter-day precision of the SBSE/LC-UV method presented a variation coefficient lower than 15%. The efficiency of the SBSE/LC-UV method was proved by analysis of plasma samples from elderly depressed patients. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A solid graphite-polyurethane composite electrode has been used to determine release profiles of verapamil, a calcium-channel blocker. The electro-oxidation process was characterized by cyclic voltammetry and electrochemical impedance spectroscopy and showed no adsorption of analyte or oxidation products, unlike at other carbon-based electrodes. Quantification gave linear ranges up to 40molL-1 with cyclic voltammetry and detection limits of 0.7molL-1 by differential pulse and square-wave voltammetry. Commercial product samples were successfully analyzed with results equal to those from spectrophotometry. Because no electrode surface renewal is needed, this electrode material has many advantages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microwave-assisted sample preparation using diluted nitric acid solutions is an alternative procedure for digesting organic samples. The efficiency of this procedure depends on the chemical properties of the samples and in this work it was evaluated by the determination of crude protein amount. fat and original carbon. Soybeans grains, bovine blood. bovine muscle and bovine viscera were digested in a cavity-microwave oven using oxidant mixtures in different acid concentrations. The digestion efficiency was evaluated based on the determination of residual carbon content and element recoveries using inductively coupled plasma optical emission spectrometry (ICP OES). In order to determine the main residual organic compounds, the digests were characterized by nuclear magnetic resonance (1 H NMR). Subsequently, studies concerning separation of nitrobenzoic acid isomers were performed by ion pair reversed phase liquid chromatography using a C18 stationary phase, water:acetonitrile:methanol (75:20:5, v/v/v) +0.05% (v/v) TFA as mobile phase and ultraviolet detection at 254 nm. Sample preparation based on diluted acids proved to be feasible and a recommendable alternative for organic sample digestion, reducing both the reagent volumes and the variability of the residues as a result of the process of decomposition. It was shown that biological matt-ices containing amino acids, proteins and lipids in their composition produced nitrobenzoic acid isomers and other organic compounds after cleavage of chemical bonds. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article proposes a simple and sensitive HPLC method with photo-diode array detection for the analysis of organic acids, monomeric polyphenols and furanic compounds in wine samples by direct injection. The chromatographic separation of 8 organic acids, 2 furans and 22 phenolic compounds was carried out with a buffered solution (pH 2.70) and acetonitrile as mobile phases and a difunctionally bonded C18 stationary phase, Atlantis dC18 (250 4.6 mm, 5mm) column. The elution was performed in 12 min for the organic acids and in 60 min for the phenolic compounds, including phenolic acids, stilbenes and flavonoids. Target compounds were detected at 210 nm (organic acids, flavan-3-ols and benzoic acids), 254 nm (ellagic acid), 280 nm (furans and cinnamic acid), 315 nm (hydroxycinnamic acids and trans-resveratrol) and 360 nm (flavonoids). The RSD for the repeatability test (n55) of peak area and retention times were below 3.1 and 0.3%, respectively, for phenolics and below 1.0 and 0.2% for organic acids. The RSDs expressing the reproducibility of the method were higher than for the repeatability results but all below 9.0%. Method accuracy was evaluated by the recovery results, with averaged values between 80 and 104% for polyphenols and 97–105% for organic acids. The calibration curves, obtained by triplicate injection of standard solutions, showed good linearity with regression coefficients higher than 0.9982 for polyphenols and 0.9997 for organic acids. The LOD was in the range of 0.07–0.49 mg/L for polyphenols (cinnamic and gallic acids, respectively) and 0.001–0.046 g/L for organic acids (oxalic and lactic acids, respectively). The method was successfully used to measure and assess the polyphenolic fingerprint and organic acids profile of red, white, rose ´ and fortified wines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a RP-HPLC method for the simultaneous quantification of free amino acids and biogenic amines in liquid food matrices and the results of the application to honey and wine samples obtained from different production processes and geographic origins. The developed methodology is based on a pre-column derivatization with o-phthaldialdehyde carried out in the sample injection loop. The compounds were separated in a Nova-Pack RP-C18 column (150 mm × 3.9 mm, 4 μm) at 35 °C. The mobile phase used was a mixture of phase A: 10 mM sodium phosphate buffer (pH 7.3), methanol and tetrahydrofuran (91:8:1); and phase B: methanol and phosphate buffer (80:20), with a flow rate of 1.0 ml/min. Fluorescence detection was used at an excitation wavelength of 335 nm and an emission wavelength of 440 nm. The separation and quantification of 19 amino acids and 6 amines was carried out in a single run as their OPA/MCE derivatives elute within 80 min, ensuring a reproducible quantification. The method showed to be adequate for the purpose, with an average RSD of 2% for the different amino acids; detection limits varying between 0.71 mg/l (Asn) and 8.26 mg/l (Lys) and recovery rates between 63.0% (Cad) and 98.0% (Asp). The amino acids present at the highest concentration in honey and wine samples were phenylalanine and arginine, respectively. Only residual levels of biogenic amines were detected in the analysed samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Baía de Guanabara é um ambiente marinho-estuarino de grande relevância ecológica e sócio-econômica, e sujeita a uma ampla gama de impactos ambientais. O sedimento é o principal destino para a maioria das substâncias introduzidas nos corpos d'água, podendo fornecer uma medida integrada da qualidade ambiental, a qual pode ser avaliada por várias abordagens. Neste projeto, a qualidade de sedimentos da Baía de Guanabara foi por uma abordagem ecotoxicológica, por meio de testes de toxicidade aguda de sedimento integral, utilizando Tiburonella viscana, e testes de toxicidade crônica de água intersticial, elutriato e interface sedimento-água, utilizando embriões de Lytechinus variegatus. Os sedimentos foram coletados em 14 estações de amostragem. Nos testes crônicos houve efeitos significativos na maioria das amostras, enquanto os sedimentos coletados nas estações 1, 2, 3, 6, 8, 10, 11, 12 e 15 apresentaram também toxicidade aguda. Houve grande concordância entre os resultados dos diferentes testes, e sua integração mostrou que os sedimentos analisados encontram-se inadequados à vida aquática, indicando degradação ambiental na baía da Guanabara. Nesse contexto, o controle das fontes poluidoras e o gerenciamento dos múltiplos usos da baía devem ser implementados, no sentido da melhora da qualidade ambiental.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste trabalho, objetivou-se analisar isotopicamente méis comercializados nas regiões Sul e Sudeste do Brasil, para a detecção de fraude. Foram colhidas amostras comerciais com registro no Serviço de Inspeção Federal, Estadual ou Municipal. As amostras foram submetidas à combustão no Analisador Elementar EA 1108 CHN e analisadas no espectrômetro de massas de razão isotópica DELTA-S (Finningan Mat). Os valores isotópicos (δ13C) dos méis in natura foram comparados aos de suas respectivas proteínas (padrão interno). Foram consideradas adulteradas as amostras cuja diferença entre o valor isotópico da proteína e do mel foi igual ou inferior a -1 . As amostras consideradas adulteradas pela análise isotópica foram submetidas a testes químicos qualitativos que não foram capazes de indicar adulteração para algumas delas. Das 61 amostras analisadas, 18,0% encontram-se adulteradas, sendo 11,5% na Região Sudeste e 6,5% na Região Sul. Ao contrário dos testes químicos, a análise isotópica mostrou-se eficaz em identificar e quantificar a adulteração de méis comerciais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to determine the antimicrobial resistance patterns of Salmonella strains isolated from slaughter-age pigs and environmental samples collected at modern swine raising facilities in Brazil. Seventeen isolates of six serotypes of Salmonella enterica subsp. enterica were isolated out of 1,026 collected samples: Salmonella Typhimurium (1), Salmonella Agona (5), Salmonella Sandiego (5), Salmonella Rissen (1), Salmonella Senftenberg (4), and Salmonella Javiana (1). Resistance patterns were determined to extended-spectrum penicillin (ampicillin), broad-spectrum cephalosporins (cefotaxime and ceftriaxone), aminoglycosides (streptomycin, neomycin, gentamicin, amikacin, and tobramycin), narrow-spectrum quinolone (nalidixic acid), broad-spectrum quinolone (ciprofloxacin and norfloxacin), tetracycline, trimethoprim, and chloramphenicol. Antimicrobial resistance patterns varied among serotypes, but isolates from a single serotype consistently showed the same resistance profile. All isolates were resistant to tetracycline, streptomycin, and nalidixic acid. One isolate, Salmonella Rissen, was also resistant to cefotaxime and tobramycin. All serotypes were susceptible to ceftriaxone, norfloxacin, ciprofloxacin, ampicillin, gentamicin, and chloramphenicol. The high resistance to tetracycline and streptomycin may be linked to their common use as therapeutic drugs on the tested farms. No relation was seen between nalidixic acid and fluoroquinolone resistance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Near-infrared Raman spectroscopy (NIRS) is a particularly promising technique that is being used in recent years for many biomedical applications. Optical spectroscopy has gained increasing prominence as a tool for quantitative analysis of biological samples, clinical diagnostic, concentration measurements of blood metabolites and therapeutic drugs, and analysis of the chemical composition of human tissues. Toxoplasmosis is an important zoonosis in public health, and domestic cats are the most important transmitters of the disease. This disease can be detected by several serological tests, which usually have a high cost and require a long time. The goal of this work was to investigate a new method to diagnosis Toxoplasma gondii infections using NIRS. In order to confirm antibody detection, 24 cat blood scrum samples were analyzed by the Raman spectra, from which 23 presented positive serology to toxoplasmosis and one was a reference negative serum. Characteristic Raman peaks allowed differentiation between negative and positive sera, confirming the possibility of antibody detection by Raman spectroscopy. These results give the first evidence that this technique can be useful to quantify antibodies in cat sera.