890 resultados para viscoelastic filament
Resumo:
This study described the formulation and characterisation of the viscoelastic, mechanical and mucoadhesive properties of thermoresponsive, binary polymeric systems composed of poloxamer (P407) and poly(acrylic acid, C974P) that were designed for use as a drug delivery platform within the oral cavity. Monopolymeric and binary polymeric formulations were prepared containing 10, 15 and 20% (w/w) poloxamer (407) and 0.10-0.25% (w/w) poly(acrylic acid, 934P). The flow theological and viscoelastic properties of the formulations were determined using controlled stress and oscillatory rheometry, respectively, the latter as a function of temperature. The mechanical and mucoadhesive properties (namely the force required to break the bond between the formulation and a pre-hydrated mucin disc) were determined using compression and tensile analysis, respectively. Binary systems composed of 10% (w/w) P407 and C934P were elastoviscous, were easily deformed under stress and did not exhibit mucoadhesion. Formulations containing 15 or 20% (w/w) Pluronic P407 and C934P exhibited a sol-gel temperature T(sol/gel), were viscoelastic and offered high elasticity and resistance to deformation at 37 degrees C. Conversely these formulations were elastoviscous and easily deformed at temperatures below the sol-gel transition temperature. The sol-gel transition temperatures of systems containing 15% (w/w) P407 were unaffected by the presence of C934P; however, increasing the concentration of C934P decreased the T(sol/gel) in formulations containing 20%(w/w) P407. Rheological synergy between P407 and C934P at 37 degrees C was observed and was accredited to secondary interactions between these polymers, in addition to hydrophobic interactions between P407 micelles. Importantly, formulations composed of 20% (w/w) P407 and C934P exhibited pronounced mucoadhesive properties. The ease of administration (below the T(sol/gel)) in conjunction with the viscoelastic (notably high elasticity) and mucoadhesive properties (at body temperature) render the formulations composed of 20% (w/w) P407 and C934P as potentially useful platforms for mucoadhesive, controlled topical drug delivery within the oral cavity. (c) 2009 Published by Elsevier B.V.
Resumo:
To evaluate the effects of warm-up and stretching, singly or combined, on isokinetic performance and electromyographic activity of the biceps femoris. Materials and methods: Sixty-four volunteers of both sexes, with mean age of 23,1 ± 3,5 years and mean body mass index of 23,5 ± 2,5 Kg/m2 were randomly assigned into 4 groups: control, warm-up (stationary bicycle for 10 minutes), stretching (4 sets of 30 seconds of hamstring muscles static stretching) and warm-up + stretching. All the volunteers were submitted to evaluation pre and post-intervention of the muscle latency time and biceps femoris RMS and the passive torque, peak torque and power of the hamstring muscles. Results: The warm-up + stretching group had reduction of muscle latency time. There was a reduction of RMS during passive torque evaluation in stretching group. The RMS during isometric evaluation was reduced in all experimental groups. The RMS during eccentric evaluation showed reduction in control and warm-up + stretching groups. The passive torque and the eccentric peak torque had no significant differences pre to post-intervention in any group. There was reduction in isometric peak torque in all groups. Conclusion: The warm-up and stretching, when applied in combination can reduce the muscle latency time; stretching protocol promoted neural changes; the protocols used did not alter the muscle viscoelastic properties
Resumo:
Continuous fiber/metal laminates (FML) offer significant improvements over current available materials for aircraft structures due to their excellent fatigue endurance and low density. Glass fibers/epoxy laminae and aluminum foil (Glare) are commonly used to obtain these hybrid composites. The environmental factors can limit the applications of composites by deteriorating the mechanical properties during service. Usually, epoxy resins absorb moisture when exposed to humid environments and metals are prone to surface corrosion. Therefore, the combination of the two materials in Glare (polymeric composite and metal). can lead to differences that often turn out to be beneficial in terms of mechanical properties and resistance to environmental influences. In this work. The viscoelastic properties. such as storage modulus (E') and loss modulus (E'), were obtained for glass fiber/epoxy composite, aluminum 2024-T3 alloy and for a glass fiber/epoxy/aluminum laminate (Glare). It was found that the glass fiber/epoxy (G/E) composites decrease the E' modulus during hygrothermal conditioning up to saturation point (6 weeks). However, for Glare laminates the E' modulus remains unchanged (49GPa) during the cycle of hygrothermal conditioning. The outer aluminum sheets in the Glare laminate shield the G/E composite laminae from moisture absorption. which in turn prevent, in a certain extent, the material from hygrothermal degradation effects. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Fiber metal laminates (FML) offer significant improvements over current available materials for aircraft structures due to their excellent mechanical characteristics and relatively low density. Non-destructive testing techniques are being used in the characterization of composite materials. Among these, vibration testing is one of the most used tools because it allows the determination of the mechanical properties. In this work, the viscoelastic properties such as elastic (E') and viscous (E) responses were obtained for aluminum 2024 alloy; carbon fiber/epoxy; glass fiber/epoxy and their hybrids aluminum 2024 alloy/carbon fiber/epoxy and aluminum 2024 alloy/glass fiber/epoxy composites. The experimental results were compared to calculated E modulus values by using the composite micromechanics approach. For all specimens studied, the experimental values showed good agreement with the theoretical values. The damping behavior, i.e. The storage modulus and the loss factor, from the aluminum 2024 alloy and fiber epoxy composites can be used to estimate the viscoelastic response of the hybrid FML. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
This paper investigates a novel design approach for a vibration isolator for use in space structures. The approach used can particularly be applicable for aerospace structures that support high precision instrumentation such as satellite payloads. The isolator is a space-frame structure that is folded in on itself to act as a mechanical filter over a defined frequency range. The absence of viscoelastic elements in such a mounting makes the design suitable for use in a vacuum and in high temperature or harsh environments with no risk of drift in alignment of the structure. The design uses a genetic algorithm based geometric optimisation routine to maximise passive vibration isolation, and this is hybridised with a geometric feasibility search. To complement the passive isolation system, an active system is incorporated in the design to add damping. Experimental work to validate the feasibility of the approach is also presented, with the active/passive structure achieving transmissibility of about 19 dB over a range of 1-250 Hz. It is shown here that the use of these novel anti-vibration mountings has no or little consequent weight and cost penalties whilst maintaining their effectiveness with the vibration levels. The approach should pave the way for the design of anti-vibration mountings that can be used between most pieces of equipment and their supporting structure. Crown Copyright (C) 2011 Published by Elsevier Ltd. All rights reserved.
Resumo:
The present article describes the preparation and characterization A anionic Collagen gels obtained from porcine intestinal submucosa after 72 h of alkaline treatment and in the form of rhamsan composites to develop injectable biomaterials for plastic for construction. All materials were characterized by SDS/polyacrylamide gel electrophoresis, infrared spectroscopy, thermal stability, potentiometric titration, rheological properties, and fluidity tests. Biocompatibility was appraised after the injection of anionic collagen:rhamsan composites at 2.5% in 60 North Folk rabbits. Independently of processing, the Collagen's secondary structure was preserved in all cases, and after 72 h of hydrolysis the Collagen was characterized by a carboxyl group content of 346 :L 9, which, at physiological pH, corresponds to an increase of 106 17 negative charges, in comparison to native Collagen, due to the selective hydrolysis of asparagine and glutamine carboxyamide side chain. Rheological studies of composites at pH 7.4 in concentrations of 2, 4, and 6% (in proportions of 75:1 and 50:1) showed a viscoelastic behavior dependent on the frequency, which is independent of concentration and proportion. In both, the concentration of the storage modulus always predominated over the loss modulus (G' > G and delta < 45 degrees). The results from creep experiments confirmed this behavior and showed that anionic collagen:rhamsan composites at pH 7.4 in the proportion of 50:1 are less elastic and more susceptible to deformation in comparison to gels in the proportion of 75:1, independent of concentration. This was further confirmed by flow experiments, indicating that the necessary force for the extrusion of anionic collagen:rhamsan composites, in comparison to anionic Collagen, was significantly smaller and with a smooth flow. Biocompatibility studies showed that the tissue reaction of anionic collagen:rhamsan composites at 2.5% in the proportion of 75:1 was compatible with the application of these gels in plastic reconstruction. These results suggest that the association of Collagen with rhamsan may be a good alternative in the replacement of glutaraidehyde to stabilize the microfibril assembly of commercial Collagen gel preparations. (c) 2005 Wiley Periodicals, Inc.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Avaliaram-se as células endoteliais, a espessura corneana e a pressão intraocular (PIO) de cães portadores de catarata madura, empregando-se viscoelástico à base de hialuronato de sódio 3% e sulfato de condroitina 4% e hidroxipropilmetilcelulose 2%, utilizando-se 20 cães, distribuídos entre os dois grupos dos viscoelásticos. A técnica cirúrgica adotada foi a da facoemulsificação bimanual. As avaliações tonométricas foram efetuadas antes e após o ato cirúrgico, aos 1, 7, 14, 21, 28 e 60 dias de pós-operatório, e a microscopia especular, antes e após 7, 28 e 60 dias. Não houve diferença estatística entre os grupos quanto à PIO, com exceção aos 14 dias, em que se observou maior PIO com o uso de hialuronato de sódio 3% e sulfato de condroitina 4%. Não houve diferença entre os grupos quanto aos parâmetros relacionados ao endotélio, com diminuição discreta da densidade celular endotelial e aumento da área celular com a utilização de hidroxipropilmetilcelulose 2%. A utilização de ambos os dispositivos viscoelásticos analisados é recomendada para o procedimento de facoemulsificação em cães.
Resumo:
The analgesic efficacy of tramadol and/or vedaprofen was evaluated in cats submitted for elective ovariohysterectomy, using a randomised double blind placebo controlled design. Forty adult female cats (3.0 +/- 0.32 kg; 1.8 +/- 0.7 years) were distributed into four groups. Vedaprofen PO (0.5 mg/kg), tramadol SC (2 mg/kg), both, or placebo was administered 1 h before surgery and every 24 and 8 h, respectively, for 72 h after surgery. Pain score evaluated by interactive visual analogue and composite pain score and hyperalgesia by the von Frey filament test were recorded at 1, 2, 4, 6, 8, 12, 24, 28, 32, 48, 52, 56, 72, 96 h and on the 7th day after surgery. Animals treated with combined vedaprofen and tramadol treatment did not need rescue analgesia, did not develop hyperalgesia, and their serum cortisol concentrations and pain scores were lower than placebo until 24 and 72 h after surgery, respectively. Combined vedaprofen and tramadol treatment provided more effective postoperative analgesia and prevented hyperalgesia than when used on their own. Multimodal technique is a superior method of treating pain after feline ovariohysterectomy. This work also provides evidence for the benefits of analgesia for up to 3 days following ovariohysterectomy. (C) 2008 ESFM and AAFP. Published by Elsevier Ltd. All rights reserved.
Resumo:
Objectives: This pilot study aims to investigate the prevalence of noncarious cervical lesions (NCCLs) in a student population at the Faculty of Dentistry of Aracatuba-UNESP and to assess the potential relation between buccal hygiene habits and the presence and number of NCCLs.Methods: This study was conducted with a sample of 58 young volunteers (15 men and 43 women; mean age, 23.6 +/- 1.8 years and 22.3 +/- 2.4 years, respectively). The research was divided into three steps: 1) clinical assessment; 2) oral-hygiene practices self-report questionnaire; and 3) analysis of toothbrush filament deformations. After the clinical exam the participants were divided into two groups, a control group (without NCCLs) and a test group (NCCLs), according to NCCL presence. The data were statistically analyzed with SPSS 16.0 software, using t-test, chi(2), Fisher exact test, and Spearman correlation.Results: NCCLs were present in 53% of the subjects. The presence of NCCLs was marginally statistically associated with age (p=0.15) and proportionally more prevalent in male (80%) subjects (p=0.01). NCCLs were more concentrated in the posterior-superior quadrant (93%) in both the right (90%) and left (55%) sides of the mouth. The direct rank correlation was presented between presence of NCCLs and toothbrush firmness; and between number of NCCLs and age and force applied during toothbrushing.Conclusion: Within the limitations of this pilot study, the use of medium and hard toothbrushes and greater force applied during toothbrushing might contribute to the development and/or aggravation of NCCLs.
Resumo:
We studied the ultrastructural aspects of pre-pupae and pupae ovaries of Dermatobia hominis. Physiological degeneration of gonial cells was observed: (a) after the ovarioles differentiation, in the oogonia residing in the apical region of the ovary; (b) at the beginning of vitellogenesis, in the cystoblasts close to the terminal filament. The significance of gonial cell degeneration was correlated with the physiological changes wich occur in the ovary during development.
Resumo:
In this paper, the occurrence and new morphological data of Unilatus unilatus Mizelle et Kritsky, 1967 from the gills of Hypostomus strigaticeps (Regan, 1907), Hypostomus regani (Ihering, 1905), and Hypostomus iheringii (Regan, 1908) from the Chavantes reservoir, So Paulo State, Brazil are reported. Unilatus unilatus from this reservoir presents differences in relation to the holotype previously described such as, eggs with no bifid or trifid filament and a rounded termination, anterior bar slightly curved with a posterior projection, and posterior bar which may present three shapes. This is the first record of U. unilatus in southeastern Brazil outside the Amazon River Basin, with H. strigaticeps, H. regani and H. iheringii as new hosts.
Resumo:
Intestine samples of Bufo sp. tadpoles with parasitism confirmed for Giardia agilis were studied by transmission electron microscopy. The G. agilis trophozoites were long and thin. The plasma membrane was sometimes undulated and the cytoplasm, adjacent to the dorsal and ventral regions, showed numerous vacuoles. The two nuclei presented prominent nucleoli. The cytoplasm was electron-dense with free ribosomes, glycogen and rough endoplasmic reticulum-like structures. Polyhedral inclusions were observed in the cytoplasm and outside the protozoan; some of these inclusions exhibited membrane disruption. The flagella ultrastructure is typical, with the caudal pair accompanied by the funis. Next to the anterior pair, osmiophilic material was noticed. The ventro-lateral flange was short and thick, supported by the marginal plates that penetrated into its distal extremity; only its distal portion had adjacent osmiophilic filament. The G. agilis trophozoites showed the general subcellular feature of the genus. However, the ventro-lateral flange ultrastructure was an intermediate type between G. muris and G. duodenalis.
Resumo:
Morphological data concerning the venom gland of worker ants of Pachycondyla striata revealed that this gland consists of three distinct regions: an external secretory portion, composed by a secretory filament that bifurcates in order to give rise to other two filaments; an internal secretory portion, represented by the convoluted gland; and a storage portion, represented by a sac-shaped reservoir. The ultrastructural analysis showed that the reservoir is enveloped by a simple pavementous epithelium, coated internally with a cuticle. The external secretory portion is composed by cells forming a simple cubic epithelium, in which the apical portion presents numerous microvilli while the basal portion of the cells shows infoldings of the plasma membrane containing numerous mitochondria. The convoluted gland possesses cells of irregular morphology with nuclei containing condensed chromatin, suggesting inactivity. However, these cells are in fact undergoing secretory activity, which is probably added to the final secretion produced by the gland. The cytoplasm of these cells contains several elements distributed therein, such as ribosomes and polyribosomes, lipid droplets, and protein inclusions in the form of crystals, thus Suggestive of protein storage, which would be used by the insect when metabolically required. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Themorphology of the venom gland in workers of the ant Pachycondyla striata (F. Smith) (Hymenoptera: Ponerinae) consists of an elongated sac that is directly connected to the sting apparatus. Three distinct regions compose this gland: the external secretory portion, composed by a secretory filament that bifurcates to originate another two; the internal secretory portion, which is represented by the convoluted gland from which rises the excretory duct that liberates the venom; and the storage portion, consisting of a large sac-shaped reservoir. The histology showed that the gland possesses a strong musculature on its distal third. Underneath these muscle layers, we noted the presence of an epithelium that envelops the internal wall of the reservoir. The presence of a convoluted gland as well as secretion inside the reservoir was also noted.