966 resultados para valve actuator


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method is proposed for determining the optimal placement and controller design for multiple distributed actuators to reduce the vibrations of flexible structures. In particular, application of piezoceramic patches to a horizontally-slewing single-link flexible manipulator modeled using the assumed modes method is investigated. The optimization method uses simulated annealing and allows placement of any number of distributed actuators of unequal length, although piezoceramics of fixed equal lengths are used in the example. It also designs an linear-quadratic-regulator controller as part of the optimization procedure. The measures of performance used in the investigation to determine optimality are the total mass of the system and the time integral of the absolute value of the hub and tip position error. This study also varies the relative weightings for each of these performance measures to observe the effects on the controller designs and piezoceramic patch positions in the optimized solutions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated the hydrodynamic performance of kangaroo aortic valve matrices (KMs) (19, 21, and 23 mm), as potential scaffolds in tissue valve engineering using a pulsatile left heart model at low and high cardiac outputs (COs) and heart rates (HRs) of 60 and 90 beats/min. Data were measured in two samples of each type, pooled in two CO levels (2.1 +/- 0.7 and 4.2 +/- 0.6 L/min; mean +/- standard errors on the mean), and analyzed using analysis of variance with CO level, HR, and valve type as fixed factors and compared to similar porcine matrices (PMs). Transvalvular pressure gradient (Delta P) was a function of HR (P < 0.001) and CO (P < 0.001) but not of valve type (P = 0.39). Delta P was consistently lower in KMs but not significantly different from PMs. The effective orifice area and performance index of kangaroo matrices was statistically larger for all sizes at both COs and HRs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 52-year-old male with idiopathic hypereosinophilic syndrome (HES) was transferred to our institution following the development of acute respiratory failure and shock. He had previously undergone tricuspid valve replacement with bioprosthetic valves on two occasions: the initial surgery for severe native tricuspid valve stenosis and the redo surgery for severe prosthetic valve stenosis and regurgitation. Conventional imaging assessment using transoesophageal echocardiography was suboptimal and comprehensive assessment of prosthetic valve function was aided by the use of intracardiac echocardiography (ICE). ICE provided high quality 2D imaging of the prosthesis demonstrating thrombus-like material coating the inner surfaces of the prosthetic valve stents effectively forming a tunnel-like obstruction. Unusual hemodynamics secondary to severe tricuspid stenosis were demonstrated by CW Doppler with intermittent signal fusion resulting from blunted respiratory variation in the markedly elevated right atrial pressure relative to right ventricular pressure. Successful balloon valvuloplasty was performed with ICE proving highly valuable in guiding balloon position as well as monitoring the efficacy of the subsequent inflations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of an advanced outdoor valve requires coordinated research in the areas of light-triggered self-protecting thyristors, light triggering systems, insulation, cooling and mechanical design aspects. This thesis addresses the first two areas primarily, with a conceptual discussion of the remainder. Using the experience gained from evaluation of a prototype thyristor and computer IKdelling of turn-on behaviour, a light-triggered thyristor with immunity to damage from weak optical triggering and dv/dt triggering was designed, manufactured and evaluated. The optical turn-on process was investigated by measuring currents and voltages in the gate structure during turn-on, and this yielded insights not obtained through conventional measurement techniques. The mechanism by which the thyristor was immune to weak triggering damage is explained, and techniques for optimising the design of the gate structure are proposed. The most significant achievement, however, was the first demonstration of the feasibility of self-protection against forward recovery failure onditions. Furthermore, this was achieved without the need for complex structures or high levels of irradiation. The perfomance of the devices was limited by the inrush capability of the Zones, but it is believed that this can be improved by conventional means. A light triggering system was developed using sem~conductor lasers, and this incorporated several improvements over prior art In terms of optical performance and flexibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To examine the detailed operation of the power distribution network in a future more electric aircraft that employs electric actuation systems, a Micro-Cap SPICE simulation is developed for one of the essential buses. Particular attention is paid to model accurately the most important effects that influence system power quality. Representative system and flight data are used to illustrate the operation of the simulation and to assess the power quality conditions within the network as the flight control surfaces are deployed. The results illustrate the importance of correct cable sizing to ensure stable operation of actuators during transient conditions.