895 resultados para test retest reliability


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Materials Engineering

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The Nutrition-Behavior Inventory (NBI) is a self-administered instrument that allows eating habits to be correlated with psychopathological symptoms. The objective was to translate and adapt the NBI to Portuguese, and test the Portuguese NBI’s reliability. The second aim was to verify its sensitivity for identification of risk factors in terms of behavior/eating habits in children and adolescents. Methods: The NBI was translated, adapted, and back-translated. The Portuguese version of the NBI was then applied (N = 96; 9-12 years). In order to verify the internal consistency, Cronbach’s alpha was used. The psychopathological indicators of the participants were accessed using the Child Behavior Checklist (CBCL). The mean CBCL scores were analyzed in relation to the NBI data (cutoff point: ≥ 30 with indicators, and < 30 without). Results: Internal consistency was high (Cronbach’s alpha = 0.89) for the NBI. The CBCL scores correlated significantly with NBI (> 30) on the following: anxiety and depression (p = 0.041), social difficulties (p = 0.028), attention problems (p = 0.001), aggressive behavior (p = 0.015); ADHD (p < 0.001), and conduct problems (p = 0.032). Conclusion: The present results indicate that the NBI is a reliable instrument. The NBI can be useful for evaluating psychopathological symptoms related to the eating habits and behaviors of children and adolescents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Symbol Digit Modalities Test (SDMT) is a widely used instrument to assess information processing speed, attention, visual scanning, and tracking. Considering that repeated evaluations are a common need in neuropsychological assessment routines, we explored testretest reliability and practice effects of two alternate SDMT forms with a short inter-assessment interval. A total of 123 university students completed the written SDMT version in two different time points separated by a 150-min interval. Half of the participants accomplished the same form in both occasions, while the other half filled different forms. Overall, reasonable testretest reliabilities were found (r = .70), and the subjects that completed the same form revealed significant practice effects (p < .001, dz = 1.61), which were almost non-existent in those filling different forms. These forms were found to be moderately reliable and to elicit a similar performance across participants, suggesting their utility in repeated cognitive assessments when brief inter-assessment intervals are required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Questions: A multiple plot design was developed for permanent vegetation plots. How reliable are the different methods used in this design and which changes can we measure? Location: Alpine meadows (2430 m a.s.l.) in the Swiss Alps. Methods: Four inventories were obtained from 40 m(2) plots: four subplots (0.4 m(2)) with a list of species, two 10m transects with the point method (50 points on each), one subplot (4 m2) with a list of species and visual cover estimates as a percentage and the complete plot (40 m(2)) with a list of species and visual estimates in classes. This design was tested by five to seven experienced botanists in three plots. Results: Whatever the sampling size, only 45-63% of the species were seen by all the observers. However, the majority of the overlooked species had cover < 0.1%. Pairs of observers overlooked 10-20% less species than single observers. The point method was the best method for cover estimate, but it took much longer than visual cover estimates, and 100 points allowed for the monitoring of only a very limited number of species. The visual estimate as a percentage was more precise than classes. Working in pairs did not improve the estimates, but one botanist repeating the survey is more reliable than a succession of different observers. Conclusion: Lists of species are insufficient for monitoring. It is necessary to add cover estimates to allow for subsequent interpretations in spite of the overlooked species. The choice of the method depends on the available resources: the point method is time consuming but gives precise data for a limited number of species, while visual estimates are quick but allow for recording only large changes in cover. Constant pairs of observers improve the reliability of the records.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A direct agglutination test (DAT) and an immunofluorescence technique (IFAT) were compared for detection of Leishmania infantum infection in 43 dogs and five foxes from Alto-Douro and Arrábida, two known endemic areas in Portugal. In four dogs with proved canine leishmaniasis, both DAT and IFAT showed positive readings (titres >1:320 and >1:128). Of 34 samples collected from apparently healthy dogs, ten were positive by both serological tests and eight were serologically positive by one test or the other. Three foxes out of five captured in this area, scored titres indicative of leishmaniasis in both DAT and IFAT. The concordance between DAT and IFAT in all collected samples (48) was 81.25%. Considering these and previous studies in the adjacent Mediterranean areas, the seroprevalence of L. infantum infection in the canine and vulpine populations appear to be of high magnitude.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Current guidelines underline the limitations of existing instruments to assess fitness to drive and the poor adaptability of batteries of neuropsychological tests in primary care settings. Aims: To provide a free, reliable, transparent computer based instrument capable of detecting effects of age or drugs on visual processing and cognitive functions. Methods: Relying on systematic reviews of neuropsychological tests and driving performances, we conceived four new computed tasks measuring: visual processing (Task1), movement attention shift (Task2), executive response, alerting and orientation gain (Task3), and spatial memory (Task4). We then planned five studies to test MedDrive's reliability and validity. Study-1 defined instructions and learning functions collecting data from 105 senior drivers attending an automobile club course. Study-2 assessed concurrent validity for detecting minor cognitive impairment (MCI) against useful field of view (UFOV) on 120 new senior drivers. Study-3 collected data from 200 healthy drivers aged 20-90 to model age related normal cognitive decline. Study-4 measured MedDrive's reliability having 21 healthy volunteers repeat tests five times. Study-5 tested MedDrive's responsiveness to alcohol in a randomised, double-blinded, placebo, crossover, dose-response validation trial including 20 young healthy volunteers. Results: Instructions were well understood and accepted by all senior drivers. Measures of visual processing (Task1) showed better performances than the UFOV in detecting MCI (ROC 0.770 vs. 0.620; p=0.048). MedDrive was capable of explaining 43.4% of changes occurring with natural cognitive decline. In young healthy drivers, learning effects became negligible from the third session onwards for all tasks except for dual tasking (ICC=0.769). All measures except alerting and orientation gain were affected by blood alcohol concentrations. Finally, MedDrive was able to explain 29.3% of potential causes of swerving on the driving simulator. Discussion and conclusions: MedDrive reveals improved performances compared to existing computed neuropsychological tasks. It shows promising results both for clinical and research purposes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Most ventricular assist devices (VADs) currently used in infants are extracorporeal. These VADs require long-term anticoagulation therapy and extensive surgery, and two devices are needed for biventricular support. We designed a biventricular assist device based on shape memory alloy that reproduces the hemodynamic effects of cardiomyoplasty, supporting the heart with a compressing movement, and evaluated its performance in a dedicated mockup system. Nitinol fibers are the device's key component. Ejection fraction (EF), cardiac output (CO), and generated systolic pressure were measured on a test bench. Our test bench settings were a preload range of 0-15 mm Hg, an afterload range of 0-160 mm Hg, and a heart rate (HR) of 20, 30, 40, and 60 beats/min. A power supply of 15 volts and 3.5 amperes was necessary. The EF range went from 34.4% to 1.2% as the afterload and HR increased, along with a CO from 180 to 6 ml/min. The device generated a maximal systolic pressure of 25 mm Hg. Cardiac compression for biventricular assistance in child-sized heart using shape memory alloy is technically feasible. Further testing remains necessary to assess this VAD's in vivo performance range and its reliability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Topological indices have been applied to build QSAR models for a set of 20 antimalarial cyclic peroxy cetals. In order to evaluate the reliability of the proposed linear models leave-n-out and Internal Test Sets (ITS) approaches have been considered. The proposed procedure resulted in a robust and consensued prediction equation and here it is shown why it is superior to the employed standard cross-validation algorithms involving multilinear regression models

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The Foot and Ankle Ability Measure (FAAM) is a self reported questionnaire for patients with foot and ankle disorders available in English, German, and Persian. This study plans to translate the FAAM from English to French (FAAM-F) and assess the validity and reliability of this new version.METHODS: The FAAM-F Activities of Daily Living (ADL) and sports subscales were completed by 105 French-speaking patients (average age 50.5 years) presenting various chronic foot and ankle disorders. Convergent and divergent validity was assessed by Pearson's correlation coefficients between the FAAM-F subscales and the SF-36 scales: Physical Functioning (PF), Physical Component Summary (PCS), Mental Health (MH) and Mental Component Summary (MCS). Internal consistency was calculated by Cronbach's Alpha (CA). To assess test re-test reliability, 22 patients filled out the questionnaire a second time to estimate minimal detectable changes (MDC) and intraclass correlation coefficients (ICC).RESULTS: Correlations for FAAM-F ADL subscale were 0.85 with PF, 0.81 with PCS, 0.26 with MH, 0.37 with MCS. Correlations for FAAM-F Sports subscale were 0.72 with PF, 0.72 with PCS, 0.21 with MH, 0.29 with MCS. CA estimates were 0.97 for both subscales. Respectively for the ADL and Sports subscales, ICC were 0.97 and 0.94, errors for a single measure were 8 and 10 points at 95% confidence and the MDC values at 95% confidence were 7 and 18 points.CONCLUSION: The FAAM-F is valid and reliable for the self-assessment of physical function in French-speaking patients with a wide range of chronic foot and ankle disorders.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

When facing age-related cerebral decline, older adults are unequally affected by cognitive impairment without us knowing why. To explore underlying mechanisms and find possible solutions to maintain life-space mobility, there is a need for a standardized behavioral test that relates to behaviors in natural environments. The aim of the project described in this paper was therefore to provide a free, reliable, transparent, computer-based instrument capable of detecting age-related changes on visual processing and cortical functions for the purposes of research into human behavior in computational transportation science. After obtaining content validity, exploring psychometric properties of the developed tasks, we derived (Study 1) the scoring method for measuring cerebral decline on 106 older drivers aged ≥70 years attending a driving refresher course organized by the Swiss Automobile Association to test the instrument's validity against on-road driving performance (106 older drivers). We then validated the derived method on a new sample of 182 drivers (Study 2). We then measured the instrument's reliability having 17 healthy, young volunteers repeat all tests included in the instrument five times (Study 3) and explored the instrument's psychophysical underlying functions on 47 older drivers (Study 4). Finally, we tested the instrument's responsiveness to alcohol and effects on performance on a driving simulator in a randomized, double-blinded, placebo, crossover, dose-response, validation trial including 20 healthy, young volunteers (Study 5). The developed instrument revealed good psychometric properties related to processing speed. It was reliable (ICC = 0.853) and showed reasonable association to driving performance (R (2) = 0.053), and responded to blood alcohol concentrations of 0.5 g/L (p = 0.008). Our results suggest that MedDrive is capable of detecting age-related changes that affect processing speed. These changes nevertheless do not necessarily affect driving behavior.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the internal consistency of the version of the Michigan Alcoholism Screening Test – Geriatric Version (MAST-G) instrument, translated and adapted for Brazil. Method: This was a descriptive, cross-sectional study. Data were collected through a demographic questionnaire, the ICD-10 and the MAST-G, following the steps of translation and cultural adaptation. One hundred eleven elderly in the city of São Carlos, SP, Brazil were interviewed. Results: The mean age of those interviewed was 70 years, with 45% men and 55% women, with the mean education of three years; 92% resided with family; 48% of the subjects consumed alcoholic beverages. The MAST-G presented a good level of reliability, with Cronbach’s α = 0.7873, and good levels of sensitivity and specificity with a cutoff score of five positive responses. Conclusion: The Brazilian version of the MAST-G presented internal consistency values similar to the original English version,showing it to be adequate for use in the national context.





Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes a nonparametric test in order to establish the level of accuracy of theforeign trade statistics of 17 Latin American countries when contrasted with the trade statistics of the main partners in 1925. The Wilcoxon Matched-Pairs Ranks test is used to determine whether the differences between the data registered by exporters and importers are meaningful, and if so, whether the differences are systematic in any direction. The paper tests for the reliability of the data registered for two homogeneous products, petroleum and coal, both in volume and value. The conclusion of the several exercises performed is that we cannot accept the existence of statistically significant differences between the data provided by the exporters and the registered by the importing countries in most cases. The qualitative historiography of Latin American describes its foreign trade statistics as mostly unusable. Our quantitative results contest this view.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Many countries used the PGMI (P=perfect, G=good, M=moderate, I=inadequate) classification system for assessing the quality of mammograms. Limits inherent to the subjectivity of this classification have been shown. Prior to introducing this system in Switzerland, we wanted to better understand the origin of this subjectivity in order to minimize it. Our study aimed at identifying the main determinants of the variability of the PGMI system and which criteria are the most subjected to subjectivity. Methods and Materials: A focus group composed of 2 experienced radiographers and 2 radiologists specified each PGMI criterion. Ten raters (6 radiographers and 4 radiologists) evaluated twice a panel of 40 randomly selected mammograms (20 analogic and 20 digital) according to these specified PGMI criteria. The PGMI classification was assessed and the intra- and inter-rater reliability was tested for each professional group (radiographer vs radiologist), image technology (analogic vs digital) and PGMI criterion. Results: Some 3,200 images were assessed. The intra-rater reliability appears to be weak, particularly in respect to inter-rater variability. Subjectivity appears to be largely independent of the professional group and image technology. Aspects of the PGMI classification criteria most subjected to variability were identified. Conclusion: Post-test discussions enabled to specify more precisely some criteria. This should reduce subjectivity when applying the PGMI classification system. A concomitant, important effort in training radiographers is also necessary.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Reducing a test administration to standardised procedures reflects the test designers' standpoint. However, from the practitioners' standpoint, each client is unique. How do psychologists deal with both standardised test administration and clients' diversity? To answer this question, we interviewed 17 psychologists working in three public services for children and adolescents about their assessment practices. We analysed the numerous "client categorisations" they produced in their accounts. We found that they had shared perceptions about their clients' diversity, and reported various non-standard practices that complemented standardised test administration, but also differed from them or were even forbidden. They seem to experience a dilemma between: (a) prescribed and situated practices; (b) scientific and situated reliability; (c) commutative and distributive justice. For practitioners, dealing with clients' diversity this is a practical problem, halfway between a problem-solving task and a moral dilemma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Carbon monoxide (CO) poisoning is one of the mostcommon causes of fatal poisoning. Symptoms of CO poisoning arenonspecific and the documentation of elevated carboxyhemoglobin(HbCO) levels in arterial blood sample is the only standard ofconfirming suspected exposure. The treatment of CO poisoning requiresnormobaric or hyperbaric oxygen therapy, according to the symptomsand HbCO levels. A new device, the Rad-57 pulse CO-oximeter allowsnoninvasive transcutaneous measurement of blood carboxyhemoglobinlevel (SpCO) by measurement of light wavelength absorptions.Methods: Prospective cohort study with a sample of patients, admittedbetween October 2008 - March 2009 and October 2009 - March 2010,in the emergency services (ES) of a Swiss regional hospital and aSwiss university hospital (Burn Center). In case of suspected COpoisoning, three successive noninvasive measurements wereperformed, simultaneously with one arterial blood HbCO test. A controlgroup includes patients admitted in the ES for other complaints (cardiacinsufficiency, respiratory distress, acute renal failure), but necessitatingarterial blood testing. Informed consent was obtained from all patients.The primary endpoint was to assess the agreement of themeasurements made by the Rad-57 (SpCO) and the blood levels(HbCO).Results: 50 patients were enrolled, among whom 32 were admittedfor suspected CO poisoning. Baseline demographic and clinicalcharacteristics of patients are presented in table 1. The median age was37.7 ans ± 11.8, 56% being male. Median laboratory carboxyhemoglobinlevels (HbCO) were 4.25% (95% IC 0.6-28.5) for intoxicated patientsand 1.8% (95% IC 1.0-5.3) for control patients. Only five patientspresented with HbCO levels >= 15%. The results disclose relatively faircorrelations between the SpCO levels obtained by the Rad-57 and thestandard HbCO, without any false negative results. However, theRad-57 tend to under-estimate the value of SpCO for patientsintoxicated HbCO levels >10% (fig. 1).Conclusion: Noninvasive transcutaneous measurement of bloodcarboxyhemoglobin level is easy to use. The correlation seems to becorrect for low to moderate levels (<15%). For higher values, weobserve a trend of the Rad-57 to under-estimate the HbCO levels. Apartfrom this potential limitation and a few cases of false-negative resultsdescribed in the literature, the Rad-57 may be useful for initial triageand diagnosis of CO.