983 resultados para technical design


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Posterior reconstruction (PR) of the rhabdosphincter has been previously described during retropubic radical prostatectomy, and shorter times to return of urinary continence were reported using this technical modification. This technique has also been applied during robot-assisted radical prostatectomy (RARP); however, contradictory results have been reported. Objective: We describe here a modified technique for PR of the rhabdosphincter during RARP and report its impact on early recovery of urinary continence and on cystographic leakage rates. Design, setting, and participants: We analyzed 803 consecutive patients who underwent RARP by a single surgeon over a 12-mo period: 330 without performing PR and 473 with PR. Surgical procedure: The reconstruction was performed using two 6-in 3-0 Poliglecaprone sutures tied together. The free edge of the remaining Denonvillier`s fascia was identified after prostatectomy and approximated to the posterior aspect of the rhabdosphincter and the posterior median raphe using one arm of the continuous suture. The second layer of the reconstruction was then performed with the other arm of the suture, approximating the posterior lip of the bladder neck and vesicoprostatic muscle to the posterior urethral edge. Measurements: Continence rates were assessed with a self-administrated, validated questionnaire (Expanded Prostate Cancer Index Composite) at 1, 4, 12, and 24 wk after catheter removal. Continence was defined as the use of ""no absorbent pads."" Cystogram was performed in all patients on postoperative day 4 or 5 before catheter removal. Results and limitations: There was no significant difference between the groups with respect to patient age, body mass index, prostate-specific antigen levels, prostate weight, American Urological Association symptom score, estimated blood loss, operative time, number of nerve-sparing procedures, and days with catheter. In the PR group, the continence rates at 1, 4, 12, and 24 wk postoperatively were 22.7%, 42.7%, 91.8%, and 96.3%, respectively; in the non-PR group, the continence rates were 28.7%, 51.6%, 91.1%, and 97%, respectively. The modified PR technique resulted in significantly higher continence rates at 1 and 4 wk after catheter removal (p = 0.048 and 0.016, respectively), although the continence rates at 12 and 24 wk were not significantly affected (p = 0.908 and p = 0.741, respectively). The median interval to recovery of continence was also statistically significantly shorter in the PR group (median: 4 wk; 95% confidence interval [CI]: 3.39-4.61) when compared to the non-PR group (median: 6 wk; 95% CI: 5.18-6.82; log-rank test, p = 0.037). Finally, the incidence of cystographic leaks was lower in the PR group (0.4% vs 2.1%; p = 0.036). Although the patients` baseline characteristics were similar between the groups, the patients were not preoperatively randomized and unknown confounding factors may have influenced the results. Conclusions: Our modified PR combines the benefits of early recovery of continence reported with the original PR technique with a reinforced watertight closure of the posterior anastomotic wall. Shorter interval to recovery of continence and lower incidence of cystographic leaks were demonstrated with our PR technique when compared to RARP with no reconstruction. (C) 2010 European Association of Urology. Published by Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Curative resection of pancreatic and biliary malignancies is rare. Most tumors are inoperable at presentation, and palliation of jaundice often is the goal. Biliary decompression can be achieved by surgical diversion or endoscopic biliary stents. This study aimed to compare clinical outcomes between surgical bypass and endoscopic uncovered nitinol stents in the palliation of patients with malignant distal common bile duct obstruction. Methods A multicenter, retrospective, cohort study investigated 86 patients with inoperable malignant distal common bile duct strictures at tertiary referral centers in Medellin, Colombia. These patients had undergone surgery (group 1) or placement of an uncovered 30-Fr self-expandable nitinol stent produced locally in Medellin, Colombia (group 2). The main outcome measurements included cumulative biliary patency, hospital stay, and patient survival. Results The study enrolled 86 patients (mean age, 66 years; range, 43-78 years) including 40 patients in group 1 and 46 patients in group 2. Both groups were similar in terms of age, gender, liver metastasis, and diagnosis. Technical success was achieved for 38 patients in group 1 (95%) and 43 patients in group 2 (93%). Functional biliary decompression was obtained in for 35 of the surgical patients (88%) and 42 of the stented patients (91%). Group 2 had lower rates for procedure-related mortality (2 vs. 7.5%; p = 0.01), a lower frequency of early complications (8.7 vs. 45%; p = 0.02), and a shorter hospital stay (median, 6 vs. 12 days; p = 0.01). Recurrent jaundice occurred for three patients in group 1 (7.5%) and eight patients in group 2 (17.3%) (p = 0.198). Late gastric outlet obstruction occurred for 12.5% of the patients in group 1 and 13% of the patients in group 2 (p = 0.73). Despite the early benefits of stenting, no significant difference in the median overall survival between the two groups was found (group 1, 163 days; group 2, 178 days; p = 0.11). The limitations of this study included the small number of patients and the retrospective design. Conclusions Endoscopic stenting and surgery are effective palliation. The former is associated with fewer early complications and the latter with fewer late complications. Patients who do not qualify for curative resection may be better managed by stent placement. Surgery should be reserved for patients more likely to survive longer.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: A new nerve transfer technique using a healthy fascicle of the posterior cord for suprascapular nerve reconstruction is presented. This technique was used in a patient with posttraumatic brachial plexopathy resulting in upper trunk injury with proximal root stumps that were unavailable for grafting associated with multiple nerve dysfunction. CLINICAL PRESENTATION: A 45-year-old man sustained a right brachial plexus injury after a bicycle accident. Clinical evaluation and electromyography indicated upper trunk involvement. Trapezius muscle function and triceps strength were normal on physical examination. INTERVENTION: The patient underwent a combined supra- and infraclavicular approach to the brachial plexus. A neuroma-in-continuity of the upper trunk and fibrotic C5 and C6 roots were identified. Electrical stimulation of the phrenic and spinal accessory nerves produced no response. The suprascapular nerve was dissected from the upper trunk, transected, and rerouted to the infraclavicular fossa. A healthy fascicle of the posterior cord to the triceps muscle was transferred to the suprascapular nerve. At the time of the 1-year follow-up evaluation, arm abduction against gravity and external rotation reached 40 and 34 degrees, respectively. CONCLUSION: The posterior cord can be used as a source of donor fascicle to the suprascapular nerve after its infraclavicular relocation. This new intraplexal nerve transfer could be applied in patients with isolated injury of the upper trunk and concomitant lesion of the extraplexal nerve donors usually used for reinnervation of the suprascapular nerve.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Roux-en-Y gastric bypass (RYGB) is amongst the commonest surgical intervention for weight loss in obese patients. Gastrocutaneous fistula, which usually occurs along the vertical staple line of the pouch, is amongst its most alarming complications. Medical management comprised of wound drainage, nutritional support, acid suppression, and antibiotics may be ineffective in as many as a third of patients with this complication. We present outcomes after endoscopic application of SurgiSIS (R), which is a novel biomaterial for the treatment of this complication. Design A case series of 25 patients. Methods Twenty-five patients who had failed conservative medical management of gastrocutaneous fistula after RYGB underwent endoscopic application of SurgiSIS (R)-an acellular fibrogenic matrix biomaterial to help fistula healing. Main outcome measures Fistula closure as assessed by upper gastrointestinal imaging and endoscopic examination. Results In patients who had failed medical management lasting 4-25 (median, 7) weeks, closure of the fistulous tract was successful after one application in six patients (30%), two applications in 11 patients (55%), and three applications in three patients (15%). There were no procedure-related complications. Conclusions Endoscopic application of SurgiSIS (R)-an acellular fibrogenic matrix-is safe and effective for the treatment of gastrocutaneous fistula after RYGB.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Patients without adequate abdominal-wall transillumination are at a high risk of developing complications after PEG. Objective: We evaluated the feasibility and utility of EUS to guide PEG in patients lacking abdominal-wall transillumination. Design: Single-center case series. Setting: Tertiary-referral center. Patients: Six patients who lacked adequate abdominal-wall transillumination and 2 patients with a large laparotomy scar deemed to be at high risk of developing complications after PEG. Interventions: Patients underwent EUS-guided PEG and deployment of a standard enteral feeding tube. Main Outcome Measurements: Technical success and complication rates. Results: PEG was Successful Under EUS guidance in 5 of 8 patients. Causes of failure included all inadequate EUS window because of a prior Billroth 1 gastrectomy in one and suspected bowel interposition in 2 patients. There were no complications. Limitations: A small number of patients, uncontrolled study, and short follow-up period. Conclusions: This technique may facilitate deployment of PEG in patients who lack adequate abdominal-wall transillumination.

Relevância:

20.00% 20.00%

Publicador: