944 resultados para optimization of the fracture parameters


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diffusion-weighted spin-echo imaging of the spine has been successfully implemented for differentiation of benign fracture edema and tumor infiltration of the vertebral body. Nevertheless, this technique still suffers from insufficient image quality in numerous patients due to motion artifacts. The aim of this study was to investigate the impact of variable respiratory motion artifact suppression techniques on image quality in diffusion-weighted spin-echo imaging of the spine. In addition to phase-encoding reordering, a newly implemented right hemi-diaphragmaitc navigator for respiratory gating was used. Subjective and objective image quality parameters were compared. Respiratory motion artifact suppression has a major impact on image quality in diffusion-weighted imaging of the spine. Phase-encoding reordering does not enhance image quality while right hemi-diaphragmatic respiratory navigator gating significantly improves image quality at the cost of data acquisition time. Navigator gating should be used if standard spin-echo diffusion-weighted imaging demonstrates insufficient image quality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The authors present the case of an open fracture of femur Cauchoix type II with an infection due to Escherichia coli, Clostridium perfringens, Enterococcus and Aspergillus fumigatus. After several sequestrectomies and five hyperbaric sessions, apyrexia was attained at the end of the third month, the femur having been stabilised with an external fixator. The 15 cm gap due to loss of bone substance, filled at each dressing with an antiseptic iodine based ointment, closed itself finishing as continuous bone five months after the accident, the granulation tissue having been recovered by thin skin grafts. A repeated fracture occurring forty-eight hours after the removal of the Hoffmann frame was treated by fitting an Ilizarov fixator arriving at consolidation in seven months. The authors examine different possibilities of accelerating osteogenesis and highlight the potential role of iodine ointment as inductive to osteogenesis stemming from a periosteal layer seemingly held in place.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECT Monoenergetic imaging with dual-energy CT has been proposed to reduce metallic artifacts in comparison with conventional polychromatic CT. The purpose of this study is to systematically evaluate and define the optimal dual-energy CT imaging parameters for specific cervical spinal implant alloy compositions. METHODS Spinal fixation rods of cobalt-chromium or titanium alloy inserted into the cervical spine section of an Alderson Rando anthropomorphic phantom were imaged ex vivo with fast-kilovoltage switching CT at 80 and 140 peak kV. The collimation width and field of view were varied between 20 and 40 mm and medium to large, respectively. Extrapolated monoenergetic images were generated at 70, 90, 110, and 130 kiloelectron volts (keV). The standard deviation of voxel intensities along a circular line profile around the spine was used as an index of the magnitude of metallic artifact. RESULTS The metallic artifact was more conspicuous around the fixation rods made of cobalt-chromium than those of titanium alloy. The magnitude of metallic artifact seen with titanium fixation rods was minimized at monoenergies of 90 keV and higher, using a collimation width of 20 mm and large field of view. The magnitude of metallic artifact with cobalt-chromium fixation rods was minimized at monoenergies of 110 keV and higher; collimation width or field of view had no effect. CONCLUSIONS Optimization of acquisition settings used with monoenergetic CT studies might yield reduced metallic artifacts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several recent studies suggest that obesity may be a risk factor for fracture. The aim of this study was to investigate the association between body mass index (BMI) and future fracture risk at different skeletal sites. In prospective cohorts from more than 25 countries, baseline data on BMI were available in 398,610 women with an average age of 63 (range, 20-105) years and follow up of 2.2 million person-years during which 30,280 osteoporotic fractures (6457 hip fractures) occurred. Femoral neck BMD was measured in 108,267 of these women. Obesity (BMI ≥ 30 kg/m(2) ) was present in 22%. A majority of osteoporotic fractures (81%) and hip fractures (87%) arose in non-obese women. Compared to a BMI of 25 kg/m(2) , the hazard ratio (HR) for osteoporotic fracture at a BMI of 35 kg/m(2) was 0.87 (95% confidence interval [CI], 0.85-0.90). When adjusted for bone mineral density (BMD), however, the same comparison showed that the HR for osteoporotic fracture was increased (HR, 1.16; 95% CI, 1.09-1.23). Low BMI is a risk factor for hip and all osteoporotic fracture, but is a protective factor for lower leg fracture, whereas high BMI is a risk factor for upper arm (humerus and elbow) fracture. When adjusted for BMD, low BMI remained a risk factor for hip fracture but was protective for osteoporotic fracture, tibia and fibula fracture, distal forearm fracture, and upper arm fracture. When adjusted for BMD, high BMI remained a risk factor for upper arm fracture but was also a risk factor for all osteoporotic fractures. The association between BMI and fracture risk is complex, differs across skeletal sites, and is modified by the interaction between BMI and BMD. At a population level, high BMI remains a protective factor for most sites of fragility fracture. The contribution of increasing population rates of obesity to apparent decreases in fracture rates should be explored. © 2014 American Society for Bone and Mineral Research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Given the significant impact the use of glucocorticoids can have on fracture risk independent of bone density, their use has been incorporated as one of the clinical risk factors for calculating the 10-year fracture risk in the World Health Organization's Fracture Risk Assessment Tool (FRAX(®)). Like the other clinical risk factors, the use of glucocorticoids is included as a dichotomous variable with use of steroids defined as past or present exposure of 3 months or more of use of a daily dose of 5 mg or more of prednisolone or equivalent. The purpose of this report is to give clinicians guidance on adjustments which should be made to the 10-year risk based on the dose, duration of use and mode of delivery of glucocorticoids preparations. A subcommittee of the International Society for Clinical Densitometry and International Osteoporosis Foundation joint Position Development Conference presented its findings to an expert panel and the following recommendations were selected. 1) There is a dose relationship between glucocorticoid use of greater than 3 months and fracture risk. The average dose exposure captured within FRAX(®) is likely to be a prednisone dose of 2.5-7.5 mg/day or its equivalent. Fracture probability is under-estimated when prednisone dose is greater than 7.5 mg/day and is over-estimated when the prednisone dose is less than 2.5 mg/day. 2) Frequent intermittent use of higher doses of glucocorticoids increases fracture risk. Because of the variability in dose and dosing schedule, quantification of this risk is not possible. 3) High dose inhaled glucocorticoids may be a risk factor for fracture. FRAX(®) may underestimate fracture probability in users of high dose inhaled glucocorticoids. 4) Appropriate glucocorticoid replacement in individuals with adrenal insufficiency has not been found to increase fracture risk. In such patients, use of glucocorticoids should not be included in FRAX(®) calculations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Posttraumatic painful osteoarthritis of the ankle joint after fracture-dislocation often has to be treated with arthrodesis. In the presence of major soft tissue lesions and important bone loss the technique to achieve arthrodesis has to be well chosen in order to prevent hardware failure, infection of bulky implants or non-union. Methods: We present the case of a 53 year-old biker suffering of a fracture-dislocation of the ankle associated with a mayor degloving injury of the heel. After initial immobilization of the lesion by external fixation in Spain the patient was transferred to our hospital for further treatment. The degloving injury of the heel with MRSA infection was initially treated by repeated débridement, changing of the configuration of the Ex Fix and antibiotic therapy with favourable outcome. Because of the bony lesions reconstruction of the ankle-joint was juged not to be an option and arthrodesis was planned. Due to bad soft-tissue situation standard open fixtion with plate and/or screws was not wanted but an option for intramedullary nailing was taken. However the use of a standard retrograde arthrodesis nail comes with two problems: 1) Risk of infection of the heel-part of the calaneus/nail in an unstable soft tissue situation with protruding nail. And 2) talo-calcaneal arthrodesis of an initially healthy subtalar joint. Given the situation of an unstable plantar/heel flap it was decided to perform anklearthrodesis by means of an anterograde nail with static fixation in the talus and in the proximal tibia. Results:This operation was performed with minimal opening at the ankle-site in order to remove the remaining cartilage and improve direct bone to bone contact. Arthrodesis was achieved by means of an anterograde T2 Stryker tibial nail.One year after the anterograde nailing the patient walks without pain for up to 4 hours with a heel of good quality and arthrodesis is achieved. Conclusion: Tibiotalar arthrodesis in the presence of mayor soft tissue lesions and bone loss can be successfully achieved with antegrade nailing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Iterative reconstruction (IR) techniques reduce image noise in multidetector computed tomography (MDCT) imaging. They can therefore be used to reduce radiation dose while maintaining diagnostic image quality nearly constant. However, CT manufacturers offer several strength levels of IR to choose from. PURPOSE: To determine the optimal strength level of IR in low-dose MDCT of the cervical spine. MATERIAL AND METHODS: Thirty consecutive patients investigated by low-dose cervical spine MDCT were prospectively studied. Raw data were reconstructed using filtered back-projection and sinogram-affirmed IR (SAFIRE, strength levels 1 to 5) techniques. Image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured at C3-C4 and C6-C7 levels. Two radiologists independently and blindly evaluated various anatomical structures (both dense and soft tissues) using a 4-point scale. They also rated the overall diagnostic image quality using a 10-point scale. RESULTS: As IR strength levels increased, image noise decreased linearly, while SNR and CNR both increased linearly at C3-C4 and C6-C7 levels (P < 0.001). For the intervertebral discs, the content of neural foramina and dural sac, and for the ligaments, subjective image quality scores increased linearly with increasing IR strength level (P ≤ 0.03). Conversely, for the soft tissues and trabecular bone, the scores decreased linearly with increasing IR strength level (P < 0.001). Finally, the overall diagnostic image quality scores increased linearly with increasing IR strength level (P < 0.001). CONCLUSION: The optimal strength level of IR in low-dose cervical spine MDCT depends on the anatomical structure to be analyzed. For the intervertebral discs and the content of neural foramina, high strength levels of IR are recommended.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to compare clinical and radiological outcome of lateral condyle fracture of the elbow in children treated with bioabsorbable or metallic material. From January 2008 to December 2009, 16 children with similar fractures and ages were grouped according to the fixation material used. Children were seen at 3, 6, and 12 months and more than 4 years (mean 51.8 months) postoperatively. The clinical results were compared using the Mayo Elbow Performance Score (MEPS). Radiographic studies of the fractured and opposite elbow were assessed at last follow-up control. Twelve children had a sufficient followup and could be included in the study. Seven could be included in the traditional group and 5 in the bioabsorbable group. At 12 months, the MEPS was 100 for every child in both groups. Asymptomatic bony radiolucent visible tracks and heterotopic ossifications were noted in both groups. There were no significant differences in terms of clinical and radiological outcome between the two groups. The use of bioabsorbable pins or screws is a reasonable alternative to the traditional use of metallic materials for the treatment of lateral condyle fracture of the elbow in children.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Non-ossifying fibromas are common benign bone tumors of children and young adults. They are usually single, asymptomatic and regress spontaneously in adulthood. Some rare cases of pathologic fractures have been described. Jaffé-Campanacci syndrome is the association of multiple non-ossifying fibromas, "café-au-lait" spots and some degree of type 1 neurofibromatosis. While the relationship between the two entities remains unclear, there seems to be some genetic similarities (partial or complete deletion of the gene NF1). Case Report: A 17 yo female patient with a neurofibromatosis type 1 was referred to our tertiary centre with a pathologic fracture of the distal femur through a non-ossifying fibroma. She had a slight mental retardation and "café-au-lait" spots. Imaging revealed multiple typical non-ossifying fibromas of both distal femurs and proximal tibias. There was no impending fracture of the controlateral side, and no other findings on thoraco-abdominal CT scanner. The fracture was treated by minimal invasive plate osteosynthesis. Histological analysis of tissue samples taken during the intervention confirmed the histologic diagnosis of non-ossifying fibroma. The fracture healed eventless and the patient returned to work after 3 months. At 12 months follow-up, the patient remained pain-free. Imaging revealed remodelling of the lesions. Conclusion: Jaffé-Campanacci syndrome is an extremely rare cause of pathologic femur fracture. These fractures can be treated like any other, and good outcome is expected. There is still no consensus in regards to definition of the disease and its relationship with type 1 neurofibromatosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Population viability analyses (PVA) are increasingly used in metapopulation conservation plans. Two major types of models are commonly used to assess vulnerability and to rank management options: population-based stochastic simulation models (PSM such as RAMAS or VORTEX) and stochastic patch occupancy models (SPOM). While the first set of models relies on explicit intrapatch dynamics and interpatch dispersal to predict population levels in space and time, the latter is based on spatially explicit metapopulation theory where the probability of patch occupation is predicted given the patch area and isolation (patch topology). We applied both approaches to a European tree frog (Hyla arborea) metapopulation in western Switzerland in order to evaluate the concordances of both models and their applications to conservation. Although some quantitative discrepancies appeared in terms of network occupancy and equilibrium population size, the two approaches were largely concordant regarding the ranking of patch values and sensitivities to parameters, which is encouraging given the differences in the underlying paradigms and input data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To demonstrate the validity and reliability of volumetric quantitative computed tomography (vQCT) with multi-slice computed tomography (MSCT) and dual energy X-ray absorptiometry (DXA) for hip bone mineral density (BMD) measurements, and to compare the differences between the two techniques in discriminating postmenopausal women with osteoporosis-related vertebral fractures from those without. METHODS: Ninety subjects were enrolled and divided into three groups based on the BMD values of the lumbar spine and/or the femoral neck by DXA. Groups 1 and 2 consisted of postmenopausal women with BMD changes <-2SD, with and without radiographically confirmed vertebral fracture (n=11 and 33, respectively). Group 3 comprised normal controls with BMD changes > or =-1SD (n=46). Post-MSCT (GE, LightSpeed16) scan reconstructed images of the abdominal-pelvic region, 1.25 mm thick per slice, were processed by OsteoCAD software to calculate the following parameters: volumetric BMD values of trabecular bone (TRAB), cortical bone (CORT), and integral bone (INTGL) of the left femoral neck, femoral neck axis length (NAL), and minimum cross-section area (mCSA). DXA BMD measurements of the lumbar spine (AP-SPINE) and the left femoral neck (NECK) also were performed for each subject. RESULTS: The values of all seven parameters were significantly lower in subjects of Groups 1 and 2 than in normal postmenopausal women (P<0.05, respectively). Comparing Groups 1 and 2, 3D-TRAB and 3D-INTGL were significantly lower in postmenopausal women with vertebral fracture(s) [(109.8+/-9.61) and (243.3+/-33.0) mg/cm3, respectively] than in those without [(148.9+/-7.47) and (285.4+/-17.8) mg/cm(3), respectively] (P<0.05, respectively), but no significant differences were evident in AP-SPINE or NECK BMD. CONCLUSION: the femoral neck-derived volumetric BMD parameters using vQCT appeared better than the DXA-derived ones in discriminating osteoporotic postmenopausal women with vertebral fractures from those without. vQCT might be useful to evaluate the effect of osteoporotic vertebral fracture status on changes in bone mass in the femoral neck.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Following the introduction of single-metal deposition (SMD), a simplified fingermark detection technique based on multimetal deposition, optimization studies were conducted. The different parameters of the original formula were tested and the results were evaluated based on the contrast and overall aspect of the enhanced fingermarks. The new formula for SMD was found based on the most optimized parameters. Interestingly, it was found that important variations from the base parameters did not significantly affect the outcome of the enhancement, thus demonstrating that SMD is a very robust technique. Finally, a comparison of the optimized SMD with multi-metal deposition (MMD) was carried out on different surfaces. It was demonstrated that SMD produces comparable results to MMD, thus validating the technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To determine the means and the reference intervals of the quantitative morphometric parameters of femoroacetabular impingement (FAI) in normal hips with high-resolution computed tomography (CT). METHODS: We prospectively included 94 adult individuals who underwent CT for thoracic, abdominal or urologic pathologies. Patients with a clinical history of hip pathology and/or with osteoarthritis on CT were excluded. We calculated means and 95 % reference intervals for imaging signs of cam-type (alpha angle at 90° and 45° and femoral head-neck offset) and pincer-type impingement (acetabular version angle, lateral centre-edge angle and acetabular index). RESULTS: The 95 % reference interval limits were all far beyond the abnormal thresholds found in the literature for cam-type and to a lesser extent for pincer-type FAI. The upper limits of the reference intervals for the alpha angles (at 90°/45°) were 68°/83° (men) and 69°/84° (women), compared to thresholds from the literature (50°, 55° or 60°). Reference intervals were similar between genders for cam-type parameters, and slightly differed for pincer-type. CONCLUSION: The 95 % reference intervals of morphometric measurements of FAI in asymptomatic hips were beyond the abnormal thresholds, which was especially true for cam-type FAI. Our results suggest the need for redefining the current morphometric parameters used in the diagnosis of FAI. KEY POINTS: ? 95 % reference intervals limits of FAI morphotype were beyond currently defined thresholds. ? Reference intervals of pincer-type morphotype measurements were close to current definitions. ? Reference intervals of cam-type morphotype measurements were far beyond the current definitions. ? Current morphometric definitions of cam-type morphotype should be used with care.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We address the performance optimization problem in a single-stationmulticlass queueing network with changeover times by means of theachievable region approach. This approach seeks to obtainperformance bounds and scheduling policies from the solution of amathematical program over a relaxation of the system's performanceregion. Relaxed formulations (including linear, convex, nonconvexand positive semidefinite constraints) of this region are developedby formulating equilibrium relations satisfied by the system, withthe help of Palm calculus. Our contributions include: (1) newconstraints formulating equilibrium relations on server dynamics;(2) a flow conservation interpretation of the constraintspreviously derived by the potential function method; (3) newpositive semidefinite constraints; (4) new work decomposition lawsfor single-station multiclass queueing networks, which yield newconvex constraints; (5) a unified buffer occupancy method ofperformance analysis obtained from the constraints; (6) heuristicscheduling policies from the solution of the relaxations.