848 resultados para fracture repair
Resumo:
The treatment of abdominal aortic aneurysm (AAA) has shifted from the exposure of the aorta artery in an open repair technique to a small groin cut in an endovascular repair. Recently, a percutaneous access for endovascular repair has appeared. This new technique aims to minimize the complications of the common femoral artery exposure, the patient discomfort and the length of hospitalizationObjectives: To compare the proportion of discharged patients within the first 48 postoperative hours of two common femoral artery accesses for endovascular repair of AAA: the open exposure technique and the percutaneous technique. Secondary objectives include to evaluate the total procedure time, the femoral access complications, the need for extra analgesia and the patient satisfaction and groin discomfort of the two techniquesDesign: Randomized controlled trial conducted between 2014 and 2017Participants: Patients diagnosed with abdominal aortic aneurysm with elective endovascular repair indication
Resumo:
Hip fractures are associated with significant morbidity and mortality. Cervical and trochanteric fractures have a different morphometry, surgical treatment, and outcome. Polypharmacy, common in older people, is associated with increased mortality. The risk factors for mortality can be identified based on cause-of-death analysis. In this population-based study, 461 older, surgically in 1999-2000 treated hip fracture patients were enrolled. Incidence, morphometry, medication, mortality, and cause-of-death were analysed. Hip fractures were most commonly sustained by women, occurred mostly indoors, and often in institutions. One in four patients had sustained a previous fracture. Routine clinical radiographs revealed no differences in the hip geometry between hip fracture types. Age-adjusted mortality was higher in men than in women during the follow-up. Chronic lung disease and male sex were predictors of mortality after cervical fracture. In men, potent anticholinergics were associated with excess age-adjusted mortality. Men were more likely to die from circulatory disease and dementia after hip fracture than women. Mortality after hip fracture was 3-fold higher than that of the general population, including every cause-of-death class. Fracture prevention in institutions and homes, indoor safety measures, and treatment of chronic lung diseases should be encouraged. Hip morphometry analyses require more accurate measures than that provided by routine radiographs. Careful use of potent anticholinergics may reduce mortality. Compared to the general population, excess mortality after hip fracture was evident up to 9 years after hip fracture. Cause-of-death analysis indicates that all major comorbidities require optimal treatment after hip fracture surgery.
Resumo:
Traunatic perineal hernia remains a rare clinical entity despite an overall increase in blunt trauma. Because of the incidence of other associated injuries, the mortality is high. Most of the perineal defects are repaired during the orthopaedics surgery to reconstitute the pelvis and few patients develop a true perineal hernia without pelvic instability. A 80-year-old woman was involved in a running over accident with disjunction of pubic symphysis, dislocation of sacrum-iliac junction and fracture of pubis and ischium. The patient was submitted to an orthopaedic surgery and latter development an perineal hernia through the genitalia. The diagnosis could be established with physical examination alone. Conventional radiology, computadorized tomography, and ultrasound should also be done to progran the surgery. The repair approach was performed using a marlex mesh, fixed in the pelvic bones, Cooper ligament, and the abdominal wall. The mesh was stood in a retro- peritoneal position, rebuilding the pelvic floor without reconstruction the pelvic bones. We conclude that this is an efficient approach to repair of traumatic postoperative perineal hernia, mainly in patients with high operative risk, when the osseous repair is not necessary.
Resumo:
Neurofibromatosis 1 (NF1) is an autosomal dominant hereditary syndrome, affecting skin, neural tissues and skeleton. Hallmarks of NF1 include benign cutaneous neurofibroma tumors, pigmentation lesions on the skin and in the iris, learning disabilities and predisposition to selected malignancies. Low bone mineral density (BMD) and osteopenia/osteoporosis are common in NF1. Osteoporosis is a systemic disorder characterized by low bone mineral density and increased fracture risk. Treatment of osteoporosis aims to prevent falls and decrease fracture risk. Osteoporosis is diagnosed in adults by measuring BMD and evaluating clinical risk factors of the patient. Bone turnover is a process of old bone resorbed by osteoclasts and new bone formed by osteoblasts. Multinuclear osteoclasts are derived from osteoclast progenitors, which can be isolated from peripheral blood. Osteoclast progenitors were isolated from 17 NF1 patients and healthy controls, and cultured in vitro to osteoclasts. NF1 osteoclasts are hyperactive, displaying increased differentiation and resorption capacity, abnormal morphology and tolerance to serum deprivation compared to control osteoclasts. These findings expanded the study to evaluate the effects of bisphosphonates, drugs designed to treat osteoporosis, in osteoclasts derived from blood samples of 20 NF1 and control persons. The number of control osteoclasts was expectedly reduced after bisphosphonate treatment. However, NF1 osteoclasts tolerated the apoptotic effect of alendronate, zoledronic acid and clodronate in vitro compared to controls. NF1-related osteoporosis was found in ~20 % of the patients, and selected laboratory parameters were measured. Patients with NF1 have increased levels of serum CTX and PINP, reflecting increased bone turnover in vivo. BMD decreases progressively in NF1 as evaluated in 19 NF1 patients 12 years after their initial BMD measurement. Patients with NF1-related osteopenia often progress to osteoporosis. This was found in patients aged 37-76.
Resumo:
We reported a case of a twenty-nine-year-old male who presented a penile fracture associated with urethral injury caused by a sexual intercourse. An ideal anamnesis and a special physical examination were determinant to correct diagnostics. Ultrasonography and uretrocistography must be performed for confirmation. The treatment is based on the presence of associated urethral injury. The surgical repair of cavernous body and urethra can produce good results, with a favorable prognosis and minimal rate of complications.
Resumo:
Objective: To evaluate the effectiveness and safety of correction of pectus excavatum by the Nuss technique based on the available scientific evidence.Methods: We conducted an evidence synthesis following systematic processes of search, selection, extraction and critical appraisal. Outcomes were classified by importance and had their quality assessed by the Grading of Recommendations Assessment, Development and Evaluation (GRADE).Results: The process of selection of items led to the inclusion of only one systematic review, which synthesized the results of nine observational studies comparing the Nuss and Ravitch procedures. The evidence found was rated as poor and very poor quality. The Nuss procedure has increased the incidence of hemothorax (RR = 5.15; 95% CI: 1.07; 24.89), pneumothorax (RR = 5.26; 95% CI: 1.55; 17.92) and the need for reintervention (RR = 4.88; 95% CI: 2.41; 9.88) when compared to the Ravitch. There was no statistical difference between the two procedures in outcomes: general complications, blood transfusion, hospital stay and time to ambulation. The Nuss operation was faster than the Ravitch (mean difference [MD] = -69.94 minutes, 95% CI: -139.04, -0.83).Conclusion: In the absence of well-designed prospective studies to clarify the evidence, especially in terms of aesthetics and quality of life, surgical indication should be individualized and the choice of the technique based on patient preference and experience of the team.
Resumo:
OBJECTIVE: to evaluate the efficacy of endovascular repair of popliteal artery aneurysms on maintaining patency of the stent in the short and medium term. METHODS: this was a retrospective, descriptive and analytical study, conducted at the Integrated Vascular Surgery Service at the Hospital da Beneficência Portuguesa de São Paulo. We followed-up 15 patients with popliteal aneurysm, totaling 18 limbs, treated with stent from May 2008 to December 2012. RESULTS: the mean follow-up was 14.8 months. During this period, 61.1% of the stents were patent. The average aneurysm diameter was 2.5cm, ranging from 1.1 to 4.5cm. The average length was 5cm, ranging from 1.5 to 10 cm. In eight cases (47.1%), the lesion crossed the joint line, and in four of these occlusion of the prosthesis occurred. In 66.7% of cases, treatment was elective and only 33.3% were symptomatic patients treated on an emergency basis. The stents used were Viabahn (Gore) in 12 cases (66.7%), Fluency (Bard) in three cases (16.7%), Multilayer (Cardiatis) in two cases (11.1%) and Hemobahn (Gore) in one case (5.6%). In three cases, there was early occlusion (16.6%). During follow-up, 88.2% of patients maintained antiplatelet therapy. There was no leakage at ultrasound (endoleak). No fracture was observed in the stents. CONCLUSION: the results of this study are similar to other published series. Probably, with the development of new devices that support the mechanical characteristics found on the thighs, there will be improved performance and prognosis of endovascular restoration.
Resumo:
The antiandrogenic therapy (ADT) for prostate cancer represents an additional risk factor for the development of osteoporosis and fragility fractures. Still, bone health of patients on ADT is often not evaluated. After literature research we found that simple preventive measures can prevent bone loss in these patients, resulting in more cost-effective solutions to the public health system and family when compared to the treatment of fractures.
Resumo:
The Repair of segmental defects in load-bearing long bones is a challenging task because of the diversity of the load affecting the area; axial, bending, shearing and torsional forces all come together to test the stability/integrity of the bone. The natural biomechanical requirements for bone restorative materials include strength to withstand heavy loads, and adaptivity to conform into a biological environment without disturbing or damaging it. Fiber-reinforced composite (FRC) materials have shown promise, as metals and ceramics have been too rigid, and polymers alone are lacking in strength which is needed for restoration. The versatility of the fiber-reinforced composites also allows tailoring of the composite to meet the multitude of bone properties in the skeleton. The attachment and incorporation of a bone substitute to bone has been advanced by different surface modification methods. Most often this is achieved by the creation of surface texture, which allows bone growth, onto the substitute, creating a mechanical interlocking. Another method is to alter the chemical properties of the surface to create bonding with the bone – for example with a hydroxyapatite (HA) or a bioactive glass (BG) coating. A novel fiber-reinforced composite implant material with a porous surface was developed for bone substitution purposes in load-bearing applications. The material’s biomechanical properties were tailored with unidirectional fiber reinforcement to match the strength of cortical bone. To advance bone growth onto the material, an optimal surface porosity was created by a dissolution process, and an addition of bioactive glass to the material was explored. The effects of dissolution and orientation of the fiber reinforcement were also evaluated for bone-bonding purposes. The Biological response to the implant material was evaluated in a cell culture study to assure the safety of the materials combined. To test the material’s properties in a clinical setting, an animal model was used. A critical-size bone defect in a rabbit’s tibia was used to test the material in a load-bearing application, with short- and long-term follow-up, and a histological evaluation of the incorporation to the host bone. The biomechanical results of the study showed that the material is durable and the tailoring of the properties can be reproduced reliably. The Biological response - ex vivo - to the created surface structure favours the attachment and growth of bone cells, with the additional benefit of bioactive glass appearing on the surface. No toxic reactions to possible agents leaching from the material could be detected in the cell culture study when compared to a nontoxic control material. The mechanical interlocking was enhanced - as expected - with the porosity, whereas the reinforcing fibers protruding from the surface of the implant gave additional strength when tested in a bone-bonding model. Animal experiments verified that the material is capable of withstanding load-bearing conditions in prolonged use without breaking of the material or creating stress shielding effects to the host bone. A Histological examination verified the enhanced incorporation to host bone with an abundance of bone growth onto and over the material. This was achieved with minimal tissue reactions to a foreign body. An FRC implant with surface porosity displays potential in the field of reconstructive surgery, especially regarding large bone defects with high demands on strength and shape retention in load-bearing areas or flat bones such as facial / cranial bones. The benefits of modifying the strength of the material and adjusting the surface properties with fiber reinforcement and bone-bonding additives to meet the requirements of different bone qualities are still to be fully discovered.
Resumo:
The aim of the present paper is to study the relationship between the fracture modes in hydrogen-assisted cracking (HAC) in microalloied steel and the emission of acoustic signals during the fracturing process. For this reason, a flux-cored arc weld (FCAW) was used in a high-strength low-alloy steel. The consumable used were the commercially available AWS E120T5-K4 and had a diameter of 1.6 mm. Two different shielding gases were used (CO2 and CO2+5% H2) to obtain complete phenomenon characterization. The implant test was applied with three levels of restriction stresses. An acoustic emission measurement system (AEMS) was coupled to the implant test apparatus. The output signal from the acoustic emission sensor was passed through an electronic amplifier and processed by a root mean square (RMS) voltage converter. Fracture surfaces were examined by scanning electron microscopy (SEM) and image analysis. Fracture modes were related with the intensity, the energy and the number of the peaks of the acoustic emission signal. The shielding gas CO2+5% H2 proved to be very useful in the experiments. Basically, three different fracture modes were identified in terms of fracture appearance: microvoid coalescence (MVC), intergranular (IG) and quasi-cleavage (QC). The results show that each mode of fracture presents a characteristic acoustic signal.
Resumo:
Factors affecting outcome after arthroscopic rotator cuff repair are unclear and there is still insufficient evidence of efficacy of any treatment modality for rotator cuff tears. The purpose of the current study was to determine in a prospective randomized multicenter trial whether there is a difference in clinical outcome between three different treatment modalities in the treatment of degenerative, atraumatic supraspinatus tendon tear in elderly patients. 180 shoulders were randomized into three treatment groups: 1) physiotherapy, 2) arthroscopic acromioplasty and physiotherapy, 3) arthroscopic rotator cuff reconstruction, acromioplasty and physiotherapy. The objective of this study was also to evaluate retrospectively the effect of trauma, the size of the rotator cuff tear, smoking habits and glenohumeral osteoarthritis on the clinical treatment outcome after arthroscopic rotator cuff repair in a consecutively prospectively collected series of patients. The patient data was gathered to the electronic database. The Constant score was used as a primary outcome measure. The follow‐up time was one year. The main finding was that operative treatment did not provide benefit over conservative regimen in elderly patients with atraumatic supraspinatus tear. Trauma did not affect on the clinical outcome and there was neither difference in the age of patients with traumatic vs. non‐traumatic rotator cuff tears. The size of the rotator cuff tear correlated significantly with the clinical results. The outcome was significantly poorer in tears with infraspinatus involvement compared to anterosuperior tears. Operatively treated rotator cuff tear patients who smoked were significantly younger than non‐smokers, and smoking was associated with poorer clinical outcome. Concomitant osteoarthritis of the glenohumeral joint was found to be a relatively common finding in supraspinatus tear patients. Osteoarthritis of the glenohumeral joint in operatively treated supraspinatus tear patients predicted poorer clinical results comparing to patients without osteoarthritis.
Resumo:
This paper draws on the basic problems related to the determination of parameters to characterize the structural behavior of concretes using Fracture Mechanics concepts. Experimental procedures and results are discussed.