781 resultados para fluorescein angiography


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present thesis, carried out at the Analytical Group of the Faculty of Industrial Chemistry in Bologna, is to develop a new electrochemical method for the determination of the Antioxidant Capacity (AOC). The approach is based on the deposition of a non-conducting polymeric film on the working electrode surface and the following exposition to the radicals OH· produced by H2O2 photolysis. The strongly oxidant action of hydroxyl radicals degrades, causing an increase of the Faradic current, relevant to the redox couple [Ru(NH3)6]2+/3+ monitored by cyclic voltammetry(CV); the presence of an antioxidant compound in solution slows down the radical action, thus protecting the polymeric film and blocking the charge transfer. The parameter adopted for the quantification of the AOC, was the induction time, called also lag phase, which is the time when the degradation of the film starts. Five pure compounds, among most commonly antioxidant, were investigated : Trolox®(an analogue water-soluble of vitamin E), (L)-ascorbic acid, gallic acid, pyrogallol and (-)- epicatechin. The AOC of each antioxidant was expressed by TEAC index (Trolox® Equivalent Antioxidant Capacity), calculated from the ratio between the slope of the calibration curve of the target compound and the slope of the calibration curve of Trolox®. The results from the electrochemical method, have been compared with those obtained from some other standardized methods, widely employed. The assays used for the comparison, have been: ORAC, a spectrofluorimetric method based on the decrease of fluorescein emission after the attack of alkylperoxide radicals, ABTS and DPPH that exploit the decoloration of stable nitrogen radicals when they are reduced in presence of an antioxidant compound and, finally, a potentiometric method based on the response of the redox couple [Fe(CN)6]3-/ [Fe(CN)6]4-. From the results obtained from pure compounds, it has been found that ORAC is the methodology showing the best correlation with the developed electrochemical method, maybe since similar radical species are involved. The comparison between the considered assays, was also extended to the analysis of a real sample of fruit juice. In such a case the TEAC value resulting from the electrochemical method is higher than those from standardized assays.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. Portal pressure is measured invasively as Hepatic Venous Pressure Gradient (HVPG) in the angiography room. Liver stiffness measured by Fibroscan was shown to correlate with HVPG values below 12 mmHg. This is not surprising, since in cirrhosis the increase of portal pressure is not directly linked with liver fibrosis and consequently to liver stiffness. We hypothesized that, given the spleen’s privileged location upstream to the whole portal system, splenic stiffness could provide relevant information about portal pressure. Aim of the study was to assess the relationship between liver and spleen stiffness measured by Virtual Touch™ (ARFI) and HVPG in cirrhotic patients. METHODS. 40 consecutive patients (30 males, mean age 62y, mean BMI=26, mean Child-Pugh A6, mean platelet count=92.000/mmc, 19 HCV+, 7 with ascites) underwent to ARFI stiffness measurement (10 valid measurements in right liver lobe both surface and centre, left lobe and 20 in the spleen) and HPVG, blindly to each other. Median ARFI values of 10 samplings on every liver area and of 20 samplings on spleen were calculated. RESULTS. Stiffness could be easily measured in all patients with ARFI, resulting a mean of 2,61±0,76, 2,5±0,62 and 2,55±0,66 m/sec in the liver areas and 3.3±0,5 m/s in the spleen. Median HPVG was 14 mmHg (range 5-27); 28 patients showed values ≥10 mmHg. A positive significant correlation was found between spleen stiffness and HPVG values (r=0.744, p<0.001). No significant correlation was found between all liver stiffness and HVPG (p>0,05). AUROC was calculated to test spleen stiffness ability in discriminating patients with HVPG ≥10. AUROC = 0.911 was obtained, with sensitivity of 69% and specificity of 91% at a cut-off of 3.26 m/s. CONCLUSION. Spleen stiffness measurement with ARFI correlates with HVPG in patients with cirrhosis, with a potential of identifying patients with clinically significant portal hypertension.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Auf der Suche nach dem „vulnerablen Plaque“, der ein besonders hohes Risiko für Schlaganfall und Herzinfarkt besitzt, findet momentan ein Paradigmenwechsel statt. Anstelle des klassischen Stenosegrades gewinnt die Darstellung der Plaquemorphologie zunehmend an Bedeutung. Fragestellung: Ziel dieser Arbeit ist es, die Fähigkeiten eines modernen 16-Kanal-CT hinsichtlich der Auflösung des Plaqueinneren bei Atherosklerose der Karotiden zu untersuchen und den Halo-Effekt in vivo zu erforschen. Methoden: Für die Studie wurden von 28 Patienten mit bekannter, symptomatischer Karotisstenose vor der gefäßchirurgischen Intervention CT-Bilder angefertigt, die nachfolgend mit der Histologie der Gefäßpräparate korreliert wurden. Auf diese Weise konnten die mikroskopisch identifizierten Lipidkerne im CT-Bild eingezeichnet und hinsichtlich ihrer Fläche und Dichtewerte evaluiert werden. In einem weiteren Schritt führten 2 Radiologen in Unkenntnis der histologischen Ergebnisse unabhängig voneinander eine Befundung durch und markierten mutmaßliche Lipidkerne. Zudem wurden sowohl in der verblindeten als auch in der histologiekontrollierten Auswertung die Plaquetypen anhand der AHA-Klassifikation bestimmt. Ein dritter Befundungsdurchgang geschah unter Zuhilfenahme einer von uns entwickelten Software, die CT-Bilder farbkodiert um die Detektion der Lipidkerne zu verbessern. Anhand der Farbkodierung wurde zudem ein Indexwert errechnet, der eine objektive Zuordnung zur AHA-Klassifikation ermöglichen sollte. Von 6 Patienten wurde zusätzlich noch eine native CT-Aufnahme angefertigt, die durch MPR exakt an die Kontrastmittelserie angeglichen wurde. Auf diese Weise konnte der Halo-Effekt, der die Plaqueanteile im lumennahen Bereich überstrahlt, quantifiziert und charakterisiert werden. Ergebnisse: Während die Einstufung in die AHA-Klassifikation sowohl durch den Befunder als auch durch den Softwarealgorithmus eine hohe Korrelation mit der Histologie aufweist (Typ IV/Va: 89 %, Typ Vb: 70 %, Typ Vc: 89 %, Typ VI: 55 %), ist die Detektion der Lipidkerne in beiden Fällen nicht ausreichend gut und die Befunderabhängigkeit zu groß (Cohens Kappa: 18 %). Eine Objektivierung der AHA-Klassifikation der Plaques durch Indexberechnung nach Farbkodierung scheint möglich, wenn auch dem Befunder nicht überlegen. Die fibröse Kappe kann nicht abgegrenzt werden, da Überstrahlungseffekte des Kontrastmittels dessen HU-Werte verfälschen. Dieser Halo-Effekt zeigte sich im Median 1,1 mm breit mit einer Standardabweichung von 0,38 mm. Eine Abhängigkeit von der Kontrastmitteldichte im Gefäßlumen konnte dabei nicht nachgewiesen werden. Der Halo-Effekt fiel im Median um -106 HU/mm ab, bei einer Standardabweichung von 33 HU/mm. Schlussfolgerung: Die CT-Technologie zeigt sich, was die Darstellung von einzelnen Plaquekomponenten angeht, den bekannten Fähigkeiten der MRT noch unterlegen, insbesondere in Bezug auf die fibröse Kappe. Ihre Fähigkeiten liegen bisher eher in der Einstufung von Plaques in eine grobe Klassifikation, angelehnt an die der AHA. Die klinische Relevanz dessen jedoch gilt es in Zukunft in größeren Studien weiter zu untersuchen. Auch lässt die Weiterentwicklung der Computertomographie auf eine zukünftig höhere Auflösung der Plaquemorphologie hoffen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Myocardial perfusion quantification by means of Contrast-Enhanced Cardiac Magnetic Resonance images relies on time consuming frame-by-frame manual tracing of regions of interest. In this Thesis, a novel automated technique for myocardial segmentation and non-rigid registration as a basis for perfusion quantification is presented. The proposed technique is based on three steps: reference frame selection, myocardial segmentation and non-rigid registration. In the first step, the reference frame in which both endo- and epicardial segmentation will be performed is chosen. Endocardial segmentation is achieved by means of a statistical region-based level-set technique followed by a curvature-based regularization motion. Epicardial segmentation is achieved by means of an edge-based level-set technique followed again by a regularization motion. To take into account the changes in position, size and shape of myocardium throughout the sequence due to out of plane respiratory motion, a non-rigid registration algorithm is required. The proposed non-rigid registration scheme consists in a novel multiscale extension of the normalized cross-correlation algorithm in combination with level-set methods. The myocardium is then divided into standard segments. Contrast enhancement curves are computed measuring the mean pixel intensity of each segment over time, and perfusion indices are extracted from each curve. The overall approach has been tested on synthetic and real datasets. For validation purposes, the sequences have been manually traced by an experienced interpreter, and contrast enhancement curves as well as perfusion indices have been computed. Comparisons between automatically extracted and manually obtained contours and enhancement curves showed high inter-technique agreement. Comparisons of perfusion indices computed using both approaches against quantitative coronary angiography and visual interpretation demonstrated that the two technique have similar diagnostic accuracy. In conclusion, the proposed technique allows fast, automated and accurate measurement of intra-myocardial contrast dynamics, and may thus address the strong clinical need for quantitative evaluation of myocardial perfusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Multidetector row computed tomography over the last decade is commonly used in veterinary medicine. This new technology has an increased spatial and temporal resolution, could evaluate wider scanning range in shorter scanning time, providing an advanced imaging modality. Computed tomography angiographic studies are commonly used in veterinary medicine in order to evaluate vascular structures of the abdomen and the thorax. Pulmonary pathology in feline patients is a very common condition and usually is further evaluating with computed tomography. Up to date few references of the normal computed tomographic aspects of the feline thorax are reported. In this study a computed tomographic pulmonary angiography (CTPA) protocol is reported in normal cats and is compared with the up to date anatomical references. A CTPA protocol using a 64 MDCT in our study achieved high resolution images of the pulmonary arteries, pulmonary veins and bronchial lumen till the level of minor segmental branches. Feline pulmonary bronchial parenchyma demonstrates an architecture of mixed type with a monopedial model observed in the most anatomical parts and the dichotomic aspect is seen at the accessory lobe. The arterial and venous architecture is similar to the bronchial. Statistical analysis demonstrates the linear correlation of tracheal diameter to the felines weight. Vascular variations were noticed. The pulmonary venous system enters into the left atrium through three ostia (left cranial ostia: consisted of the anastomosis of the cranial and caudal portion of the left cranial pulmonary vein; right ostia: consisted of the anastomosis of the right cranial and middle pulmonary vein; and the caudal ostia: consisted of the anastomosis of the right and left caudal pulmonary vein). In conclusion CTPA is applicable in feline patients and provides an excellent imaging of the pulmonary arterial, venous and bronchial system till the level of minor segmental branches.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Xanthene dyes, including fluorescein, are a well-known class of fluorescent dyes, which have widespread applications in natural sciences. The synthesis of xanthene derivatives via acid catalyzed condensation of substituted phenols with phthalic anhydride, to afford the asymmetric derivatives, is well established. The high temperature, harsh reaction conditions and often low yields make this method less convenient. The synthesis of xanthene dyes by direct modification of the fluorophore moiety is a great option to circumvent the above mentioned drawbacks. rnOur new synthetic strategy for the preparation of novel asymmetric xanthene dyes via direct conversion of hydroxyl groups on 3'- and 6'-positions into leaving groups by mesylation is reported. It was discovered that 3',6'-di-mesylated fluorescein underwent a nucleophilic aromatic substitution with sulfur nucleophiles and afforded new asymmetric xanthene sulfides. rnThe impact of substituents possessing an electron-withdrawing character such as chlorines and bromines was investigated with the aim to improve the aromatic substitution on the electron-rich fluorescein structure. It was observed that the incorporation of these groups did not considerably affect the substitution reaction and the yields were comparable with the unsubstituted fluorescein. rnThis strategy provided novel fluorescent probes with the linker suitable to further modifications. The modifications of the linker delivered fluorescein derivatives that could be used as fluorescent labels in peptides, oligonucleotides and for cell imaging. rnThe hydroxyl group on the linker was modified to achieve potent bioconjugate functionality such as azide. The new fluorescent azides were obtained in a 4-step synthesis, namely 2-(6-(2-azidoethylthio)-3-oxo-3H-xanthen-9-yl)benzoic acid with an overall yield of 13%, its 2',7'-dichloro derivative with an overall yield of 10% and its 2',4',5'-tribromo derivative with an overall yield of 1%, respectively. rnAn asymmetric xanthene sulfide with an amino functionality placed on the aliphatic linker, namely 2-(6-((2-aminoethyl)thio)-3-oxo-3H-xanthen-9-yl)benzoic acid, was obtained in a 3-step synthesis with an overall yield of 33%. rnThe impact of the substitution with sulfur nucleophiles on the 6'-position of the xanthene moiety on its fluorescent characteristics was investigated. In comparison with fluorescein new asymmetric xanthene sulfides afforded lower extinction coefficients and fluorescent quantum yields. On the other hand, the substitution with a sulfur nucleophile significantly improved the photostability of xanthene dyes. It was shown that after 10 hours of continuous excitation, the asymmetric sulfur-containing xanthene fluorophores exhibited 58-94% of their initial fluorescent intensities. This observation suggested that the novel dyes were 1-2 orders of magnitude more stable than fluorescein. rnThe azido-modified xanthenes were “clicked” via Cu(I)-catalyzed azide-alkyne cycloaddition with an oligonucleotide, which contained the terminal alkyne residue. rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the Research of this Ph D Project is to improve the medical management after surgery for advanced heart failure, both after left ventricular assist devices (LVAD) implantation, and after heart transplantation in the long-term. Regarding heart transplantation (HTx), the Research Project is focused on diagnostics, classification, prevention and treatment of cardiac allograft vasculopathy (CAV), and on treatment of post-HTx cancers; the results are presented in the first part of this Thesis. In particular, the main aspect investigated are the prognostic role of information derived from coronary angiography, coronary tomography and intravascular ultrasound, and the different sensitivity of these techniques in predicting outcomes and in diagnosing CAV. Moreover, the role of mTOR inhibitors on CAV prevention or treatment is investigated, both alone and in combination with different anti-CMV prevention strategies, as well as the impact of mTOR inhibitors on clinical outcomes in the long term. Regarding LVAD, the main focus is on the role of transthoracic echocardiography in the management of patients with a continuous-flow, centrifugal, intrapericardial pump (HVAD, Heartware); this section is reported in the second part of this Thesis. The main aspects investigated are the use of echocardiography in patients with HVAD device and its interaction with the information derived from pump curves' analysis in predicting aortic valve opening status, a surrogate of the condition of support provided by the LVAD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Delivery of therapeutic nucleic acid based drugs is still very demanding and difficult to manage and monitor. For this reason, a precise method for the monitoring of RNAi pathways is necessary. This thesis explores a new approach for sensing of potentially therapeutic nucleic acids, using the interaction of so called prodyes with intracellular enzymes in a prodrug manner. To realize this concept, some non-fluorescent, fluorescein based asymmetric dyes were synthesized and their spectroscopic characteristics were studied. Azide-alkyne Click chemistry was applied for conjugation purposes, using a new protocol at weak acidic pH to get intact prodye constructs. Both, an electrophoretic mobility shift assay with polyacrylamide gels and in-cuvette experiments showed remarkable OFF-to-ON behavior of these new siRNA constructs under physiological conditions. After salt-free purification, subsequent hybridization to double-stranded ribonucleic acids and nanoformulation to lipoplexes, the prodye conjugated siRNA was examined in cellular uptake studies for First Contact Imaging. The investigated siRNA-prodye conjugates showed strong sensitivity to esterases, being hydrolyzed at the biolabile function and developing a strong fluorescence which was verified in bulk. As an optimization, a new profluorescent molecule system was designed and synthesized, which has a carbonate as biolabile 6’ protecting group and a highly water soluble 3’ clickable linker. This new non-fluorescent but colored prodye showed 12 - 320 times increased fluorescence intensities between OFF- and ON- states, depending to the deprotection method. This is the first reported molecule model of an asymmetric profluorescent fluorescein, having the very favorable 3’ &amp;amp; 6’ functions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lo scopo di questo lavoro è la caratterizzazione fisica del flat panel PaxScan4030CB Varian, rivelatore di raggi X impiegato in un ampio spettro di applicazioni cliniche, dalla radiografia generale alla radiologia interventistica. Nell’ambito clinico, al fine di una diagnosi accurata, è necessario avere una buona qualità dell’immagine radiologica mantenendo il più basso livello di dose rilasciata al paziente. Elemento fondamentale per ottenere questo risultato è la scelta del rivelatore di radiazione X, che deve garantire prestazioni fisiche (contrasto, risoluzione spaziale e rumore) adeguati alla specifica procedura. Le metriche oggettive che misurano queste caratteristiche sono SNR (Signal-to-Noise Ratio), MTF (Modulation Transfer Function) ed NPS (Noise Power Spectrum), che insieme contribuiscono alla misura della DQE (Detective Quantum Efficiency), il parametro più completo e adatto a stabilire le performance di un sistema di imaging. L’oggettività di queste misure consente anche di mettere a confronto tra loro diversi sistemi di rivelazione. La misura di questi parametri deve essere effettuata seguendo precisi protocolli di fisica medica, che sono stati applicati al rivelatore PaxScan4030CB presente nel laboratorio del Centro di Coordinamento di Fisica Medica, Policlinico S.Orsola. I risultati ottenuti, conformi a quelli dichiarati dal costruttore, sono stati confrontati con successo con alcuni lavori presenti in letteratura e costituiscono la base necessaria per la verifica di procedure di ottimizzazione dell’immagine radiologica attraverso interventi sul processo di emissione dei raggi X e sul trattamento informatico dell’immagine (Digital Subtraction Angiography).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

I raggi X, a partire dalla loro scoperta, avvenuta nel 1895 ad opera di Wilhelm Conrad Röntgen, si sono rivelati un potentissimo mezzo per lo studio della materia. In particolare in campo medico hanno permesso la nascita della diagnostica per immagini che, parallelamente allo sviluppo delle tecnologie, è diventata un mezzo imprescindibile per lo studio delle patologie. Negli ultimi decenni molti studi sono stati compiuti in particolare sui vantaggi dell’utilizzo nell’imaging di raggi X monocromatici in sostituzione dell’usuale radiazione policromatica. Con il seguente elaborato si ha l’intento di fornire un quadro generale sulla fisica dei raggi X, sulla loro interazione con la materia e sugli attuali metodi di produzione di fasci monocromatici e quasi-monocromatici, con particolare attenzione all'utilizzo su vasta scala. Sono state infine trattate le principali applicazioni della radiazione monocromatica e quasi-monocromatica nelle tecniche di imaging medico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: This study evaluates cardiovascular risk factors associated with progression of coronary artery disease (CAD) in patientswith silent ischemia followingmyocardial infarction. Hypothesis: Coronary artery disease only progresses slowly with comprehensive risk factor intervention. Methods: A total of 104 of 201 patients (51.7%) of the Swiss Interventional Study on Silent Ischemia Type II (SWISSI II) with baseline and follow-up coronary angiography were included. All patients received comprehensive cardiovascular risk factor intervention according to study protocol. Logistic regression was used to evaluate associationsbetween baseline cardiovascular risk factors and CAD progression. Results: The mean duration of follow-upwas 10.3 ± 2.4 years. At baseline, 77.9% of patients were smokers, 45.2% had hypertension, 73.1% had dyslipidemia, 7.7% had diabetes, and 48.1% had a family history of CAD. At last follow-up, only 27 patients of the initial 81 smokers still smoked, only 2.1% of the patients had uncontrolled hypertension, 10.6%of the patientshad uncontrolled dyslipidemia, and 2.1%of the patientshad uncontrolled diabetes. Coronary artery disease progression was found in up to 81 (77.9%) patients. Baseline diabetes and younger age were associatedwith increased odds of CAD progression.The time intervalbetween baseline and follow-up angiography was also associatedwith CAD progression. Conclusion: Coronary artery disease progressionwas highly prevalent in these patients despite comprehensive risk factor intervention. Further research is needed to optimize treatment of known risk factors and to identify other unknown and potentiallymodifiable risk factors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: The effect of cardiac resynchronization therapy (CRT) on right ventricular ejection fraction (RVEF) has not been well studied. Furthermore, it is unclear whether baseline RVEF influences response to CRT. To evaluate the acute and chronic effects of CRT on right ventricular systolic function, and to investigate whether baseline RVEF impacts response to CRT. METHODS AND RESULTS: Forty-four patients with a standard indication for CRT underwent radionuclide angiography at baseline and after at least 6 months' follow-up for measuring RVEF, right ventricular synchrony (using phase analysis), and left ventricular ejection fraction (LVEF). In addition, NYHA functional class and 6-min walking distance (6MWD) were evaluated. There were no significant acute changes in RVEF with CRT. After a mean follow-up of 9 +/- 5 months, RVEF was slightly improved (by 1.9 +/- 5.0% in absolute terms, P = 0.016), and to a lesser extent than LVEF (5.1 +/- 9.0%, P = 0.009 compared with RVEF). Right ventricular dyssynchrony was significantly improved at follow-up (P = 0.016). Patients with a baseline RVEF < or = 0.35 (n = 19) were less likely to improve in NYHA class (P = 0.016), and also tended to improve less in 6MWD and LVEF (P < 0.06). CONCLUSION: Cardiac resynchronization therapy has no acute effect on RVEF, and only slightly improves RVEF at follow-up. Patients with reduced RVEF at baseline were less likely to respond to CRT, indicating that right ventricular systolic dysfunction may play a role in patient selection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors report on bilateral simultaneous knee arthroplasty in a 40-year-old male patient with haemophilia A, high inhibitor titre and an aneurysma spurium of the right popliteal artery. Both knees showed a fixed flexion deformity of 20 degrees. To build up haemostasis, treatment with activated prothrombin complex concentrate (APCC) and recombinant activated factor seven (rFVIIa) was initiated preoperatively. A tourniquet was used on both sides during the operation and factor VIII (FVIII) was administered to further correct coagulopathy. On the eleventh postoperative day the patient complained of increasing pain and pressure in the right knee. An ultrasound suggested aneurysm, which was confirmed by substraction angiography. Under the protection of rFVIIa the aneurysm could be coiled and further rehabilitation was uneventful. At one year post-op the patient presented a range of motion of 90/5/0 degrees for both knees and had returned to full time office work. This case indicates that haemophiliacs with high antibody titre and destruction of both knees can be operated on in one session in order to diminish the operative risk of two consecutive surgical procedures, thus allowing an effective rehabilitation programme. Because of the significant frequency of popliteal aneurysms, preoperative angiography is recommended.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Varicose vein rupture is a rare cause of death, although varicosities are a common pathology. We present three cases of sudden death due to varicose vein rupture. After a review of the literature, the case circumstances and the findings of imaging examination, performed in two cases, are presented. One of them had undergone a post-mortem computed tomography angiography (PMCTA), and one a PMCTA as well as a post-mortem magnetic resonance (PMMR) imaging prior to conventional autopsy. One of the cases presented herein is, to our knowledge, the youngest known fatality due to varicose vein rupture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present paper, the authors describe a case of fatal thoracic impalement in a victim of a road traffic accident, by penetration of a metal handrail. The driver lost control of his car while overtaking three cars. Due to the force of the vehicle collision with a metal railing, the upper cross bar penetrated the front of the car and subsequently the driver was pierced by the center-pillar in the car. Death occurred at the scene of the accident. Postmortem, computed tomography, computed tomography angiography and a magnetic resonance tomography were performed and revealed severe heart destruction and hemorrhage as cause of death. The present case report shows that postmortem imaging might have value as a screening method to decide whether arising forensic questions can be answered just by imaging like in the presented case or if further examinations such as conventional autopsy are required.