873 resultados para fire rating
Resumo:
The video FireMovie_2000-2011.avi shows an animation with all MODIS fire product maps of the area sequenced over time. Colors in the video describe MODIS classes as follows: MODIS classification and color scale: Class 0 - not processed - Dark blue (1 frame) Class 3 - water - Light Blue (rivers and some lakes) Class 4 - clouds - Green blue Class 5 - non fire land - Yellow green Class 8 - nominal confidence fire - Red Class 9 - high confidence fire - Dark red
Resumo:
The concept of national self-determination is a highly contested concept from very outset. It is partly due to its dual parentage, namely nationalism and liberalism. Prior to 1945 it was only a political concept without legal binding. With the incorporation of the principle in the UN Charter it was universalized and legalized. However, there were two competing interpretations at the UN based on de-colonization and representative government. How to define self and what really determined remain highly controversial. How to reconcile the international norm of sovereignty of state and self determination of people became more complex problem with the tide of secessionist movements based on ethno-nationalism. The concept of internal self-determination came as a compromise; but it is also very vague and harbors a wide range of interpretations.
Resumo:
The understanding of the structure and dynamics of the intricate network of connections among people that consumes products through Internet appears as an extremely useful asset in order to study emergent properties related to social behavior. This knowledge could be useful, for example, to improve the performance of personal recommendation algorithms. In this contribution, we analyzed five-year records of movie-rating transactions provided by Netflix, a movie rental platform where users rate movies from an online catalog. This dataset can be studied as a bipartite user-item network whose structure evolves in time. Even though several topological properties from subsets of this bipartite network have been reported with a model that combines random and preferential attachment mechanisms [Beguerisse Díaz et al., 2010], there are still many aspects worth to be explored, as they are connected to relevant phenomena underlying the evolution of the network. In this work, we test the hypothesis that bursty human behavior is essential in order to describe how a bipartite user-item network evolves in time. To that end, we propose a novel model that combines, for user nodes, a network growth prescription based on a preferential attachment mechanism acting not only in the topological domain (i.e. based on node degrees) but also in time domain. In the case of items, the model mixes degree preferential attachment and random selection. With these ingredients, the model is not only able to reproduce the asymptotic degree distribution, but also shows an excellent agreement with the Netflix data in several time-dependent topological properties.
Resumo:
The design, construction and operation of the tunnels of M-30, the major ring road in the city of Madrid (Spain), represent a very interesting project in wich a wide variety of situations -geometrical, topographical, etc.- had to be covered, in variable conditions of traffic. For that reasons, the M-30 project is a remarkable technical challenge, which, after its completion, turned into an international reference. From the "design for safety" perspective, a holistic approach has been used to deal with new technologies, integration of systems and development of the procedures to reach the maximum level. However, one of the primary goals has been to achieve reasonable homogeneity characteristics which can permit operate a netword of tunels as one only infraestructure. In the case of the ventilation system the mentioned goals have implied innovative solutions and coordination efforts of great interest. Consequently, this paper describes the principal ideas underlying the conceptual solution developed focusing on the principal peculiarities of the project.
Resumo:
The main objective of ventilation systems in case of fire is the reduction of the possible consequences by achieving the best possible conditions for the evacuation of the users and the intervention of the emergency services. The required immediate transition, from normal to emergency functioning of the ventilation equipments, is being strengthened by the use of automatic and semi-automatic control systems, what reduces the response times through the help to the operators, and the use of pre-defined strategies. A further step consists on the use of closed-loop algorithms, which takes into account not only the initial conditions but their development (air velocity, traffic situation, etc.), optimizing smoke control capacity.
Resumo:
After an experimental fire in steep shrub land in a temperate–humid region (north-west Spain), the effects of two post-fire stabilisation treatments (grass seeding and straw mulching) on the chemical properties of eroded sediments,and the amount of nutrients lost with them, we reevaluated relative to control burnt soil, over a period of 13 months. Total C and N concentrations, and d 13 C, indicated that sediments were mainly contributed by charred plant and litter material. The highest concentrations of extractable base cations in the sediments occurred during the first 3 months following fire, especially for Na and K. As treatments had little or no effect on nutrient concentration in sediments, differences in nutrient losses were due to the 10-fold lower sediment production in mulching compared with other treatments. In control and seeding treatments, the accumulated amounts of nutrients lost with sediments were 989–1028kgha 1 (C), 77kgha 1 (N), 1.9–2.4kgha 1 (Ca), 0.9–1.1kgha 1 (Mg), 0.48–0.55kgha 1 (NH 4 þ –N), 0.39–0.56kgha 1 (K), 0.19–0.34kgha 1 (Na) and , 0.1kgha 1 (P and NO 3 –N) . These values accounted for 22–25% (total C and N) and 5–12% (NH 4 þ –N, Ca, P and Mg) of available nutrients in ash, and 1.0–2.4% of those in ash þ topsoil. As nutrient and sediment losses were strongly correlated, the reduction of the latter by mulching application leads to an effective decrease of post-fire nutrient losses.
Resumo:
The effects of fire ( Control burned soil) and two emergency stabilisation techniques (grass Seeding and straw Mulching ) on 20 chemical characteristics were evaluated on 0 – 5 cm top-soils sampled 1, 90, 180 and 365 days after an experimental fi re in a steep shrubland of a temperate-humid region (NW Spain). Most part of pH (in H 2 O and KCl) variance was explained by the sampling date. No clear temporal trends were identi fi able for total soil C and N content, likely due to the large SOM pool in these soils; however, changes on soil δ 13 C were explained by the deposition of 13 C-depleted ashes, followed by its progressive erosion, while those on soil δ 15 N were a consequence of fi re induced N outputs. After the fi re, NH 4 + – N, P, Na, K, Mg, Ca, Mn, Cu, Zn and B concentrations increased, while those of NO 3 − – N, Al, Fe and Co did not vary significantly. Despite a significant decline with time, concentrations of Mg, Ca and Mn at the end of the study were still higher than in unburned soil, while those of K, Cu, Zn and B were similar to the pre-fire levels and those of NH 4 + – N, P and Na were below pre-fire values. Mulching and Seeding treatments for burned soil emergency stabilisation had significant effects on soil δ 15 N and extractable K, Mg and Ca, while data were inconclusive for their possible effects on the extractable Al, Fe and Co
Resumo:
This paper describes the design of an original twin capacitive load that is able of tracing simultaneously the I?V characteristics of two photovoltaic modules. Besides, an example of the application of this dual system to the outdoor rating of photovoltaic modules is presented, whose results have shown a good degree of repeatability.
Resumo:
The research is an exhaustive study of the microstructure and of the stress-strain curves of structural steel S460N at temperatures typical of a fire. It includes a fractographic study of the fracture suifaces of cylindrical specimens, tensile tested at different fire scenarios, explaining the relationship between the failure micromechanisms and temperature. The paper ends with the comparison between the experimentally found strain-stress curves with that one's proposed by the EUROCODE EC3, resulting that in the case of steel S460N these are on the side ofsafety.
Resumo:
Interacciones entre la vegetación del Holoceno, el fuego y el clima en el oeste de España, ejemplo con datos de la turbera del Maíllo.
Resumo:
The research is an exhaustive study of the microstructure and of the stress-strain curves of structural steel S460N at temperatures typical of a fire. It includes a fractographic study of the fracture suifaces of cylindrical specimens, tensile tested at different fire scenarios, explaining the relationship between the failure micromechanisms and temperature. The paper ends with the comparison between the experimentally found strain-stress curves with that one's proposed by the EUROCODE EC3, resulting that in the case of steel S460N these are on the side ofsafety.
Resumo:
The main objective of ventilation systems in tunnels is to reach the highest possible safety level both in service and fire situation; being the fire one, the most relevant when designing the system. When designing a longitudinal ventilation system, the methodology to evaluate the capacity of the system is similar both in service and fire situation, with the exception of the chimney effect and the phenomena of thermal transfer which is responsible or the changes in the density of the air. When facing the dimensioning task for longitudinal ventilated tunnels, although similar methodologies are used in different countries, specific hypothesis (aerodynamic, thermal properties, traffic) even if discussed in the literature or current practice, are not usually detailed in the regulations or recommendations. The aim of this paper is to propose a probabilistic approach to the problem which would allow the designer, and the tunnel owner, to understand the uncertainty and sensibility adopted in the results and, eventually, identify possible ways of optimizing the ventilation solution to be adopted.
Resumo:
Between 2003 and 2007 an urban network or road tunnels with a total constructed tubes length of 45 km was built in the city of Madrid. This amazing engineering work, known as "Calle 30 Project" counted with different kinds of tunnel typologies and ventilation systems. Due to the length of the tunnels and the impact of the work itself, the tunnels were endowed with a great variety of installations to provide the maximum levels of safety both for users and the infrastructure includieng, in some parts of the tunnel, fixed fire fighting system based on water mist. Whithin this framework a large-scale programme of fire tests was planned to study different aspects related to fire safety in the tunnels including the phenomena of the interaction between ventilation and extinguishing system. In addition, these large scale fire tests allowed fire brigades of the city of Madrid an opportunity to define operational procedures for specific fire fighting in tunnels and evaluate the possibilities of fixed fire fighting systems. The tests were carried out in the Center of Experimentation "San pedro of Anes" which includes a 600 m tunnel with a removable false ceiling for reproducing different ceiling heights and ventilation conditions (transverse and longitudinal ones). Interesting conclusions on the interaction of ventilation and water mist systems were obtained but also on other aspects including performance of water mist system in terms of reduction of gas temperatures or visibility conditions. This paper presents a description of the test's programme carried out and some previous results obtained.
Resumo:
Between 2003 and 2007 an urban network of road tunnels with a total constructed tubes length of 45 km was built in the city of Madrid. This amazing engineering work, known as “Calle30 Project” counted with different kinds of tunnel typologies and ventilation systems. Due to the length of the tunnels and the impact of the work itself, the tunnels were endowed with a great variety of installations to provide the maximum levels of safety both for users and the infrastructure including,in some parts of the tunnel, fixed fire fighting system based on water mist. Within this framework a large-scale campaign of fire tests were planned to study different aspects related to fire safety in the tunnels including the phenomena of the interaction between ventilation and extinction system. In addition, this large scale fire tests allowed fire brigades of the city of Madrid an opportunity to define operational procedures for specific fire fighting in tunnels and evaluate the possibilities of fixed fire fighting systems. The tests were carried out in the Center of Experimentation "San Pedro of Anes" which counts with a 600 m tunnel with a removable false ceiling for reproducing different ceiling heights and ventilation conditions (transverse and longitudinal ones). Interesting conclusions on the interaction of ventilation and water mist systems were obtained but also on other aspects including performance of water mist system in terms of reduction of gas temperatures or visibility conditions. This paper presents a description of the test’s campaign carried out and some previous results obtained.