992 resultados para field efficiency
Resumo:
The main properties of magnetized strangelets, namely, their energy per baryon, radius and electric charge, are studied in the unpaired strange quark matter phase. Temperature effects are taken into account in order to study their stability compared to the (56)Fe isotope and non-magnetized strangelets within the framework of the MIT bag model. It is concluded that the presence of a magnetic field tends to stabilize more the strangelets, even when temperature is considered. We find that the electric charge is modified in the presence of the magnetic field, leading to higher charge values for magnetized strangelets, when compared to the non-magnetized case.
Resumo:
In this abstract is presented an energy management system included in a SCADA system existent in a intelligent home. The system control the home energy resources according to the players definitions (electricity consumption and comfort levels), the electricity prices variation in real time mode and the DR events proposed by the aggregators.
Resumo:
A deposição de resíduos sólidos urbanos (RSU) em aterros sanitários (AS) tem uma dimensão que necessita de uma atenção especial por parte da sociedade. Deste acto podem resultar situações gravosas para o meio ambiente se não forem tomadas as medidas correctas. Um dos pontos que necessita de uma particular atenção é o tratamento das águas lixiviantes dos aterros sanitários, uma vez que estas apresentam geralmente cargas altamente poluentes. O presente trabalho apresenta a estrutura de um aterro sanitário, definindo os seus princípios de funcionamento, bem como as principais características a ter em consideração para a sua concepção e construção. É ainda abordada a composição dos resíduos sólidos produzidos em Portugal de acordo com (1) e as características quantitativas e qualitativas do lixiviado produzido por um AS. São apresentados os sistemas tratamento convencionais, biológicos e físico-químicos, mais utilizados em Portugal para o tratamento de águas lixiviantes, relacionando as problemáticas e as limitações associadas a cada um deles. É ainda apresentado o tratamento combinado de águas lixiviantes com águas residuais e a recirculação de lixiviado no sistema de tratamento, assim como algumas das vantagens associadas a estas práticas. Tendo por base, uma situação real, avalia-se um caso de estudo, que visa a avaliação do funcionamento da estação de pré-tratamento das águas lixiviantes produzidas no aterro sanitário do ecoparque de Palmela, tendo em consideração o facto de este tratamento ser realizado em combinação com o tratamento de águas residuais urbanas. A avaliação do funcionamento da estação de pré-tratamento de águas lixiviantes (EPTAL) é realizada de acordo com os dados fornecidos nos relatórios elaborados pela empresa LUSÁGUA, que apresentam os valores das cargas poluentes medidos à entrada e saída da EPTAL, verificando com estes dados se os valores limite de emissão medidos à saída da EPTAL são respeitados. São ainda propostas algumas alterações baseadas em pareceres técnicos que acompanham os relatórios elaborados pela LUSÁGUA e um estudo elaborada pela ECOserviços em Fevereiro de 2010 onde se obtêm eficiências de etapas de tratamentos com base em testes laboratoriais e testes realizados na própria EPTAL.
Resumo:
O presente documento enquadra-se no âmbito do trabalho final do mestrado (TFM) do curso de Engenharia Civil, na área de especialização de Hidráulica, do Instituto Superior de Engenharia de Lisboa, sob a forma de um projeto na fase de estudo prévio com o título ―Gestão Sustentável da Água no empreendimento turístico Parque de Campismo da Ilha do Pessegueiro situado em Porto Covo - Região de Turismo do Alentejo‖. Este trabalho é constituído essencialmente por 5 partes. Sendo a primeira uma breve introdução às questões a abordar, a segunda corresponde à discrição teórica do uso eficiente da água baseando-se no PNEUA (Programa nacional para o uso eficiente da água). Já a terceira parte é relativa ao atual sistema de utilização da água no Parque de campismo da ilha do pessegueiro (PCIP), sendo a quarta o estudo do desenvolvimento do projecto para a gestão eficiente da água no empreendimento e a quinta parte o estudo de viabilidade económica e financeira a implementar no projecto. Para além da implementação de medidas de poupança são também objetivos principais deste trabalho a reutilização da água através da recolha, o tratamento e armazenamento das águas residuais e aproveitamento das águas pluviais para posterior abastecimento do sistema de utilização em descargas sanitárias, lavagem de pavimentos e regas de espaços verdes. São, portanto, três os subsistemas de gestão eficiente da água que se pretende implementar. Dá-se importância ao estudo de viabilidade económica do projeto, cujo período de retorno do capital investido em capitais próprios e alheios é de seis anos. Este projeto pretende dar apoio técnico ao uso eficiente da água no PCIP, de forma a conseguir por um lado obter vantagens económicas e por outro proteger o ambiente. As vantagens económicas são interessantes para orientar os recursos financeiros para outros investimentos e as questões ambientais são a base de uma campanha, já em curso, para obtenção de certificação energética, em conjunto com outras práticas já em curso, nomeadamente a recolha seletiva de resíduos sólidos para recircular e aproveitamento de energia solar.
Resumo:
Titanium films have been deposited on stainless steel metal sheets using dc magnetron sputtering technique at different substrate temperatures. The structure of the titanium films strongly depend on the substrate temperature. The titanium film deposited at the substrate temperature lower than 300 ◦C has a loose flat sheet grains structure and the titanium film prepared at the substrate temperature higher than 500 ◦C has a dense nubby grains structure. The DSSC assembled using stainless steel sheet coated with titanium film deposited at high substrate temperature has a low charge transfer resistance in the TiO2/Ti interface and results in a high conversion efficiency. The DSSC assembled using stainless steel sheet coated with titanium film deposited at temperature higher than 500 ◦C has higher conversion efficiency than that assembled using titanium metal sheet as the substrate. The maximum conversion efficiency, 2.26% is obtained for DSSC assembled using stainless steel sheet coated with titanium film deposited at 700 ◦C substrate temperature, which is about 70% of the conversion efficiency of the FTO reference cell used in this study.
Resumo:
Copyright © 2013 Springer Netherlands.
Resumo:
Copyright © 2013 Springer Netherlands.
Resumo:
Copyright © 2013 Springer Netherlands.
Resumo:
Copyright © 2013 Springer Netherlands.
Resumo:
Copyright 2013 Springer Netherlands.
Resumo:
Copyright © 2013 Springer Netherlands.
Resumo:
V Congreso de Eficiencia y Productividad EFIUCO, Córdoba, 19-20 Mayo 2011.
Resumo:
One of the most effective ways of controlling vibrations in plate or beam structures is by means of constrained viscoelastic damping treatments. Contrary to the unconstrained configuration, the design of constrained and integrated layer damping treatments is multifaceted because the thickness of the viscoelastic layer acts distinctly on the two main counterparts of the strain energy the volume of viscoelastic material and the shear strain field. In this work, a parametric study is performed exploring the effect that the design parameters, namely the thickness/length ratio, constraining layer thickness, material modulus, natural mode and boundary conditions have on these two counterparts and subsequently, on the treatment efficiency. This paper presents five parametric studies, namely, the thickness/length ratio, the constraining layer thickness, material properties, natural mode and boundary conditions. The results obtained evidence an interesting effect when dealing with very thin viscoelastic layers that contradicts the standard treatment efficiency vs. layer thickness relation; hence, the potential optimisation of constrained and integrated viscoelastic treatments through the use of properly designed thin multilayer configurations is justified. This work presents a dimensionless analysis and provides useful general guidelines for the efficient design of constrained and integrated damping treatments based on single or multi-layer configurations. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Purpose: The aim of this paper is to promote qualitative methodology within the scientific community of management. The specific objective is oriented to propose an empirical research process based on case study method. This is to ensure rigor in the empirical research process, that future research may follow a similar procedure to that is proposed. Design/methodology/approach: Following a qualitative methodological approach, we propose a research process that develops according to four phases, each with several stages. This study analyses the preparatory and field work phases and their stages. Findings: The paper shows the influence that case studies have on qualitative empirical research process in management. Originality/value:. Case study method assumes an important role within qualitative research by allowing for the study and analysis of certain types of phenomena that occur inside organisations, and in respect of which quantitative studies cannot provide an answer.
Resumo:
The present work aims at evaluating the efficiency of an organic polymer from vegetal source used as coagulant for treating different types of industrial effluents. This coagulant (Flox-QT) is obtained from the Black Acacia (Acacia mearnsii). The effluents studied were produced in petrochemical, leather, cork stoppers, metalworking, olive oil, glue, paint (printing), textile and paper industries. The parameters analyzed in the effluents before and after treatment were selected according to the type of wastewater and included pH, conductivity, apparent colour, turbidity, total suspended solids (TSS), chemical oxygen demand (COD) and some metals. The coagulant proved to be efficient for almost all effluents tested. The best results were obtained for the paper industry wastewater, with 91% removal of chemical oxygen demand and 95% of total suspended solids removal. The estimated cost of this treatment would be only 0.24 Euro per cubic meter of treated effluent, only regarding the price of the coagulant and the required dosage. The use of this coagulant is also adequate for the valorisation of the sludge obtained, which in this case could be recycled for paper production.