998 resultados para fibre rope


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ductility of concrete made with commercially available steel and synthetic fibres has been investigated. Flexural stress–deflection relationships have been used to determine: flexural strength, flexural toughness, equivalent flexural strength, and equivalent flexural strength ratio. The flexural toughness of concrete was found to increase considerably when steel and synthetic fibres were used. However, equal dosages of different fibres did not result in specimens with the same flexural toughness. Flexural toughness differences of almost 35 J existed even at the same fibre dosage. This also resulted in considerable differences in the minimum required ground supported slab thickness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an innovative sensor system, created specifically for new civil engineering structural monitoring applications, allowing specially packaged fiber grating-based sensors to be used in harsh, in-the-field measurement conditions for accurate strain measurement with full temperature compensation. The sensor consists of two fiber Bragg gratings that are protected within a polypropylene package, with one of the fiber gratings isolated from the influence of strain and thus responding only to temperature variations, while the other is sensitive to both strain and temperature. To achieve this, the temperature-monitoring fiber grating is slightly bent and enclosed in a metal envelope to isolate it effectively from the strain. Through an appropriate calibration process, both the strain and temperature coefficients of each individual grating component when incorporated in the sensor system can be thus obtained. By using these calibrated coefficients in the operation of the sensor, both strain and temperature can be accurately determined. The specific application for which these sensors have been designed is seen when installed on an innovative small-scale flexi-arch bridge where they are used for real-time strain measurements during the critical installation stage (lifting) and loading. These sensors have demonstrated enhanced resilience when embedded in or surface-mounted on such concrete structures, providing accurate and consistent strain measurements not only during installation but subsequently during use. This offers an inexpensive and highly effective monitoring system tailored for the new, rapid method of the installation of small-scale bridges for a variety of civil engineering applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For Variable Stiffness (VS) composites with steered curvilinear tow paths, the fiber orientation angle varies continuously throughout the laminate, and is not required to be straight, parallel and uniform within each ply as in conventional composite laminates. Hence, the thermal properties (conduction), as well as the structural stiffness and strength, vary as functions of location in the laminate, and the associated composite structure is often called a “variable stiffness” composite structure. The steered fibers lead not only to the alteration of mechanical load paths, but also to the alteration of thermal paths that may
result in favorable temperature distributions within the laminate and improve the laminate performance. Evaluation of VS laminate performance under thermal loading is the focus of this chapter. Thermal performance evaluations require experimental and numerical analysis of VS laminates under different processing and loading conditions. One of the advantages of using composite materials in many applications is the tailoring capability of the laminate,
not only during the design phase but also for manufacturing. Heat transfer through variable conduction and chemical reaction (degree of cure) occurring during manufacturing (curing) plays an important role in the final thermal and mechanical performance, and shape of composite structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Weathering of stone is one of the major reasons for the damage of stone masonry structures and it takes place due to interlinked chemical, physical and biological processes in stones. The key parameters involved in the deterioration processes are temperature, moisture and salt. It is now known that the sudden variations in temperature and moisture greatly accelerate the weathering process of the building stone fabric. Therefore, in order to monitor these sudden variations an effective and continuous monitoring system is needed. Furthermore, it must consist of robust sensors which are accurate and can survive in the harsh environments experienced in and around masonry structures. Although salt penetration is important for the rate of deterioration of stone masonry structures, the processes involved are much slower than the damage associated with temperature and moisture variations. Therefore, in this paper a novel fibre optic temperature cum relative humidity sensor is described and its applicability in monitoring building stones demonstrated. The performance of the sensor is assessed in an experiment comprising wetting and drying of limestone blocks. The results indicate that the novel fibre optic relative humidity sensor which is tailor made for applications in masonry structures performed well in wetting and drying tests, whilst commercial capacitance based sensors failed to recover during the drying regime for a long period after a wetting regime. That is, the fibre optic sensor has the capability to measure both sorption and de-sorption characteristics of stone blocks. This sensor is used in a test wall in Oxford and the data thus obtained strengthened the laboratory observations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the reliability and thus the suitability of optical fibre strain sensors for surface strain measurement in concrete structures was investigated. Two different configurations of optical strain sensors were used each having different mountings making them suitable for different uses in various structures. Due to the very limited time available to install the sensors and take result, commercially packaged sensors were used. In the tests carried out each sensor was mounted onto a concrete beam which was then subjected to a range of known and calibrated loadings. The performance of the optical strain sensors thus evaluated was compared with the results of conventional techniques. This comparison allows for selecting the best performing combination of sensor/mounting, i.e. long-gauge sensor with mounts bolted to threaded rods glued into the concrete for use in future work in a field test where a limited time window was available for installation, testing and post-test demounting. © 2012 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare the efficacy and cost effectiveness of a senna-fibre combination and lactulose in treating constipation in long stay elderly patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A replicated field plot experiment was carried out in Northern Ireland in 1996 with flax, cv Ariane, and linseed, cv Flanders, each grown at seed rates of 500, 1000 and 1500 seeds/m(2), in which a comparison was made between netting of the standing crop, following desiccation by the trimesium salt of glyphosate (Touchdown, Zeneca Ltd.), and water or dew retting of the pulled crop. Application at 4 litres/ha on 9 August, 33 days after the mid-point of flowering (MPF), achieved both desiccation and partial retting of the crop within 14 days. Over 16 % clean long fibre was extracted by scutching the stand-netted flax straw, yielding 800 kg/ha fibre, while water retting achieved 20 extraction and 980 kg/ha yield and dew netting 8.5 % and 420 kg/ha respectively. The dew retting was uneven, resulting in high losses during fibre extraction, while water retting for 7 days at 25 degreesC did not achieve complete retting resulting in a high content of woody fragments in the fibre. Fibre yields increased by almost 50 % with the high v. low seed rate. Linseed was less well retted than flax and contained higher levels of impurity in the extracted long fibre which, after retting, yielded 120 to 310 kg/ha at extraction rates of 2.9 % to 7.5 %.

In a second experiment in 1998 flax cvs. Viola and Evelyn were treated with the timesium salt of glyphosate at rates of 2, 4 or 6 litres/ha 10, 20, 30 or 40 days after MPF on 5 July. Viola desiccated satisfactorily at all spray dates with 4 and 6 litres/ha glyphosate. The 20-day treatment desiccated more slowly than the 30-day and the 2 litres/ha rate did not achieve complete desiccation, but the trimesium salt of glyphosate achieved better desiccation at this timing than that found in earlier studies with the original form of glyphosate. Evelyn desiccated more slowly and less evenly than Viola particularly at the 20-day and 40-day timings. Spraying at MPF + 10 days interrupted early development of the seed and fibre significantly reducing yields. Due to slower desiccation the 20-day timing was no better than the 30-day, which was well retted by harvest 44 days after spraying, and gave the highest yield of clean long fibre. The spraying 40 days after MPF was considered too late in the season to be of practical use. It was concluded that retting of standing flax following desiccation with the trimesium salt of glyphosate was more effective than with the earlier formulation and that resting of the standing crop could achieve equivalent or better retting with similar fibre yields to traditional retting methods. The optimum spray timing was found to be about 30 days after MPF with 4 or 6 litres/ha, the lower rate being adequate for glyphosate responsive varieties such as Viola.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fiber-optic multichannel correlator/convolver based on a two-dimensional systolic array architecture is described. Experimental verification of processor performance is presented.