844 resultados para electromagnetic current
Resumo:
Autopsy-negative sudden cardiac deaths (SCD) seen in forensic practice are most often thought to be the result of sudden arrhythmic death syndrome. Postmortem genetic analysis is recommended in such cases, but is currently performed in only a few academic centers. In order to determine actual current practice, an on-line questionnaire was sent by e-mail to members of various forensic medical associations. The questions addressed routine procedures employed in cases of sudden cardiac death (autopsy ordering, macroscopic and microscopic cardiac examination, conduction tissue examination, immunohistochemistry and electron microscopy, biochemical markers, sampling and storage of material for genetic analyses, toxicological analyses, and molecular autopsy). Some questions concerned the legal and ethical aspects of genetic analyses in postmortem examinations, as well as any existing multidisciplinary collaborations in SCD cases. There were 97 respondents, mostly from European countries. Genetic testing in cases of sudden cardiac death is rarely practiced in routine forensic investigation. Approximately 60% of respondents reported not having the means to perform genetic postmortem testing and 40% do not collect adequate material to perform these investigations at a later date, despite working at university hospitals. The survey demonstrated that many of the problems involved in the adequate investigation of SCD cases are often financial in origin, due to the fact that activities in forensic medicine are often paid by and dependent on the judicial authorities. Problems also exist concerning the contact with family members and/or the family doctor, as well as the often-nonexistent collaboration with others clinicians with special expertise beneficial in the investigation of SCD cases, such as cardiologists and geneticists. This study highlights the importance in establishing guidelines for molecular autopsies in forensic medicine.
Resumo:
We describe two cases of true dorsalis pedis artery aneurysms in men referred for pulsatile mass of the dorsal part of the foot. Both aneurysms were resected and grafted with interposition of a short segment of saphenous vein. Histological analysis showed true aneurysm associated with atherosclerosis. To our knowledge, only 12 cases of true dorsalis pedis artery aneurysm have been reported previously. On the basis of our experience and after reviewing the literature, the management of this uncommon pathology was discussed.
Resumo:
Background: There may be a considerable gap between LDL cholesterol (LDL-C) and blood pressure (BP) goal values recommended by the guidelines and results achieved in daily practice. Design Prospective cross-sectional survey of cardiovascular disease risk profiles and management with focus on lipid lowering and BP lowering in clinical practice. Methods: In phase 1, the cardiovascular risk of patients with known lipid profile visiting their general practitioner was anonymously assessed in accordance to the PROCAM-score. In phase 2, high-risk patients who did not achieve LDL-C goal less than 2.6 mmol/l in phase 1 could be further documented. Results: Six hundred thirty-five general practitioners collected the data of 23 892 patients with known lipid profile. Forty percent were high-risk patients (diabetes mellitus or coronary heart disease or PROCAM-score >20%), compared with 27% estimated by the physicians. Goal attainment rate was almost double for BP than for LDL-C in high-risk patients (62 vs. 37%). Both goals were attained by 25%. LDL-C values in phase 1 and 2 were available for 3097 high-risk patients not at LDL-C goal in phase 1; 32% of patients achieved LDL-C goal of less than 2.6 mmol/l after a mean of 17 weeks. The most successful strategies for LDL-C reduction were implemented in only 22% of the high-risk patients. Conclusion: Although patients at high cardiovascular risk were treated more intensively than low or medium risk patients, the majority remained insufficiently controlled, which is an incentive for intensified medical education. Adequate implementation of Swiss and International guidelines would expectedly contribute to improved achievement of LDL-C and BP goal values in daily practice.
Resumo:
Three standard radiation qualities (RQA 3, RQA 5 and RQA 9) and two screens, Kodak Lanex Regular and Insight Skeletal, were used to compare the imaging performance and dose requirements of the new Kodak Hyper Speed G and the current Kodak T-MAT G/RA medical x-ray films. The noise equivalent quanta (NEQ) and detective quantum efficiencies (DQE) of the four screen-film combinations were measured at three gross optical densities and compared with the characteristics for the Kodak CR 9000 system with GP (general purpose) and HR (high resolution) phosphor plates. The new Hyper Speed G film has double the intrinsic sensitivity of the T-MAT G/RA film and a higher contrast in the high optical density range for comparable exposure latitude. By providing both high sensitivity and high spatial resolution, the new film significantly improves the compromise between dose and image quality. As expected, the new film has a higher noise level and a lower signal-to-noise ratio than the standard film, although in the high frequency range this is compensated for by a better resolution, giving better DQE results--especially at high optical density. Both screen-film systems outperform the phosphor plates in terms of MTF and DQE for standard imaging conditions (Regular screen at RQA 5 and RQA 9 beam qualities). At low energy (RQA 3), the CR system has a comparable low-frequency DQE to screen-film systems when used with a fine screen at low and middle optical densities, and a superior low-frequency DQE at high optical density.
Resumo:
BACKGROUND: In recent years several trials have addressed treatment challenges in Crohn's disease. Clinical trials however, represent a very special situation. AIMS: To perform a cross-sectional survey among gastroenterologists on the current clinical real life therapeutic approach focussing on the use of biologics. METHODS: A survey including six main questions on clinical management of loss of response, diagnostic evaluation prior to major treatment changes, preference for anti-tumour necrosis factor (TNF) agent, (de-)escalation strategies as well as a basic section regarding personal information was sent by mail to all gastroenterologists in Switzerland (n=318). RESULTS: In total, 120 questionnaires were analysed (response rate 37.7%). 90% of gastroenterologists in Switzerland use a thiopurine as the first step-up strategy (anti-TNF alone 7.5%, combination 2.5%). To address loss of response, most physicians prefer shortening the interval of anti-TNF administration followed by dose increase, switching the biologic and adding a thiopurine. In case of prolonged remission on combination therapy, the thiopurine is stopped first (52.6%) after a mean treatment duration of 15.7 months (biologic first in 41.4%). CONCLUSIONS: Everyday clinical practice in Crohn's disease patients appears to be incongruent with clinical data derived from major trials. Studies investigating reasons underlying these discrepancies are of need to optimize and harmonize treatment.
Resumo:
We have constructed a forward modelling code in Matlab, capable of handling several commonly used electrical and electromagnetic methods in a 1D environment. We review the implemented electromagnetic field equations for grounded wires, frequency and transient soundings and present new solutions in the case of a non-magnetic first layer. The CR1Dmod code evaluates the Hankel transforms occurring in the field equations using either the Fast Hankel Transform based on digital filter theory, or a numerical integration scheme applied between the zeros of the Bessel function. A graphical user interface allows easy construction of 1D models and control of the parameters. Modelling results are in agreement with other authors, but the time of computation is less efficient than other available codes. Nevertheless, the CR1Dmod routine handles complex resistivities and offers solutions based on the full EM-equations as well as the quasi-static approximation. Thus, modelling of effects based on changes in the magnetic permeability and the permittivity is also possible.
Resumo:
The spatial resolution visualized with hydrological models and the conceptualized images of subsurface hydrological processes often exceed resolution of the data collected with classical instrumentation at the field scale. In recent years it was possible to increasingly diminish the inherent gap to information from point like field data through the application of hydrogeophysical methods at field-scale. With regards to all common geophysical exploration techniques, electric and electromagnetic methods have arguably to greatest sensitivity to hydrologically relevant parameters. Of particular interest in this context are induced polarisation (IP) measurements, which essentially constrain the capacity of a probed subsurface region to store an electrical charge. In the absence of metallic conductors the IP- response is largely driven by current conduction along the grain surfaces. This offers the perspective to link such measurements to the characteristics of the solid-fluid-interface and thus, at least in unconsolidated sediments, should allow for first-order estimates of the permeability structure.¦While the IP-effect is well explored through laboratory experiments and in part verified through field data for clay-rich environments, the applicability of IP-based characterizations to clay-poor aquifers is not clear. For example, polarization mechanisms like membrane polarization are not applicable in the rather wide pore-systems of clay free sands, and the direct transposition of Schwarz' theory relating polarization of spheres to the relaxation mechanism of polarized cells to complex natural sediments yields ambiguous results.¦In order to improve our understanding of the structural origins of IP-signals in such environments as well as their correlation with pertinent hydrological parameters, various laboratory measurements have been conducted. We consider saturated quartz samples with a grain size spectrum varying from fine sand to fine gravel, that is grain diameters between 0,09 and 5,6 mm, as well as corresponding pertinent mixtures which can be regarded as proxies for widespread alluvial deposits. The pore space characteristics are altered by changing (i) the grain size spectra, (ii) the degree of compaction, and (iii) the level of sorting. We then examined how these changes affect the SIP response, the hydraulic conductivity, and the specific surface area of the considered samples, while keeping any electrochemical variability during the measurements as small as possible. The results do not follow simple assumptions on relationships to single parameters such as grain size. It was found that the complexity of natural occurring media is not yet sufficiently represented when modelling IP. At the same time simple correlation to permeability was found to be strong and consistent. Hence, adaptations with the aim of better representing the geo-structure of natural porous media were applied to the simplified model space used in Schwarz' IP-effect-theory. The resulting semi- empiric relationship was found to more accurately predict the IP-effect and its relation to the parameters grain size and permeability. If combined with recent findings about the effect of pore fluid electrochemistry together with advanced complex resistivity tomography, these results will allow us to picture diverse aspects of the subsurface with relative certainty. Within the framework of single measurement campaigns, hydrologiste can than collect data with information about the geo-structure and geo-chemistry of the subsurface. However, additional research efforts will be necessary to further improve the understanding of the physical origins of IP-effect and minimize the potential for false interpretations.¦-¦Dans l'étude des processus et caractéristiques hydrologiques des subsurfaces, la résolution spatiale donnée par les modèles hydrologiques dépasse souvent la résolution des données du terrain récoltées avec des méthodes classiques d'hydrologie. Récemment il est possible de réduire de plus en plus cet divergence spatiale entre modèles numériques et données du terrain par l'utilisation de méthodes géophysiques, notamment celles géoélectriques. Parmi les méthodes électriques, la polarisation provoquée (PP) permet de représenter la capacité des roches poreuses et des sols à stocker une charge électrique. En l'absence des métaux dans le sous-sol, cet effet est largement influencé par des caractéristiques de surface des matériaux. En conséquence les mesures PP offrent une information des interfaces entre solides et fluides dans les matériaux poreux que nous pouvons lier à la perméabilité également dirigée par ces mêmes paramètres. L'effet de la polarisation provoquée à été étudié dans différentes études de laboratoire, ainsi que sur le terrain. A cause d'une faible capacité de polarisation des matériaux sableux, comparé aux argiles, leur caractérisation par l'effet-PP reste difficile a interpréter d'une manière cohérente pour les environnements hétérogènes.¦Pour améliorer les connaissances sur l'importance de la structure du sous-sol sableux envers l'effet PP et des paramètres hydrologiques, nous avons fait des mesures de laboratoire variées. En détail, nous avons considéré des échantillons sableux de quartz avec des distributions de taille de grain entre sables fins et graviers fins, en diamètre cela fait entre 0,09 et 5,6 mm. Les caractéristiques de l'espace poreux sont changées en modifiant (i) la distribution de taille des grains, (ii) le degré de compaction, et (iii) le niveau d'hétérogénéité dans la distribution de taille de grains. En suite nous étudions comment ces changements influencent l'effet-PP, la perméabilité et la surface spécifique des échantillons. Les paramètres électrochimiques sont gardés à un minimum pendant les mesures. Les résultats ne montrent pas de relation simple entre les paramètres pétro-physiques comme par exemples la taille des grains. La complexité des media naturels n'est pas encore suffisamment représenté par les modèles des processus PP. Néanmoins, la simple corrélation entre effet PP et perméabilité est fort et consistant. En conséquence la théorie de Schwarz sur l'effet-PP a été adapté de manière semi-empirique pour mieux pouvoir estimer la relation entre les résultats de l'effet-PP et les paramètres taille de graines et perméabilité. Nos résultats concernant l'influence de la texture des matériaux et celles de l'effet de l'électrochimie des fluides dans les pores, permettront de visualiser des divers aspects du sous-sol. Avec des telles mesures géo-électriques, les hydrologues peuvent collectionner des données contenant des informations sur la structure et la chimie des fluides des sous-sols. Néanmoins, plus de recherches sur les origines physiques de l'effet-PP sont nécessaires afin de minimiser le risque potentiel d'une mauvaise interprétation des données.
Resumo:
This article reports on a project at the Universitat Oberta de Catalunya (UOC: The Open University of Catalonia, Barcelona) to develop an innovative package of hypermedia-based learning materials for a new course entitled 'Current Issues in Marketing'. The UOC is a distance university entirely based on a virtual campus. The learning materials project was undertaken in order to benefit from the advantages which new communication technologies offer to the teaching of marketing in distance education. The article reviews the main issues involved in incorporating new technologies in learning materials, the development of the learning materials, and their functioning within the hypermedia based virtual campus of the UOC. An empirical study is then carried out in order to evaluate the attitudes of students to the project. Finally, suggestions for improving similar projects in the future are put forward.
A Survey on Detection Techniques to Prevent Cross-Site Scripting Attacks on Current Web Applications
Resumo:
RATIONALE, AIMS AND OBJECTIVES: There is little evidence regarding the benefit of stress ulcer prophylaxis (SUP) outside a critical care setting. Overprescription of SUP is not devoid of risks. This prospective study aimed to evaluate the use of proton pump inhibitors (PPIs) for SUP in a general surgery department. METHOD: Data collection was performed prospectively during an 8-week period on patients hospitalized in a general surgery department (58 beds) by pharmacists. Patients with a PPI prescription for the treatment of ulcers, gastro-oesophageal reflux disease, oesophagitis or epigastric pain were excluded. Patients admitted twice during the study period were not reincluded. The American Society of Health-System Pharmacists guidelines on SUP were used to assess the appropriateness of de novo PPI prescriptions. RESULTS: Among 255 patients in the study, 138 (54%) received a prophylaxis with PPI, of which 86 (62%) were de novo PPI prescriptions. A total of 129 patients (94%) received esomeprazole (according to the hospital drug policy). The most frequent dosage was at 40 mg once daily. Use of PPI for SUP was evaluated in 67 patients. A total of 53 patients (79%) had no risk factors for SUP. Twelve and two patients had one or two risk factors, respectively. At discharge, PPI prophylaxis was continued in 33% of patients with a de novo PPI prescription. CONCLUSIONS: This study highlights the overuse of PPIs in non-intensive care unit patients and the inappropriate continuation of PPI prescriptions at discharge. Treatment recommendations for SUP are needed to restrict PPI use for justified indications.