1000 resultados para determinação de silício
Resumo:
In this work, analytical strategies are evaluated in order to measure accurately the ambient levels of atmospheric organic acids. Environmental considerations about the determination of low molecular weight mono- and di-carboxylic acids from urban areas of São Paulo are described.
Resumo:
Pimaradienes, including isopimaradienes, with an endocyclic double bond between C-9 and C-11 are uncommon compounds in nature. The diterpenoid pimar-9(11),15-dien-19-oic acid (1) was isolated from Mikania triangularis (Asteraceae) and the correct stereochemistry of 1was established by ¹H and 13C NMR studies of several oxidative products, mainly epoxides, of this compound and its double bond isomers.
Resumo:
A simple chemical method has been developed to quantify the silanol groups (º Si-OH) in silica as well as in coated chromatographic supports for use in packed - column Gas Chromatography. After adsorption of 10 mg/mL methylene blue, centrifuging action and filtration, the absorbance of the solution was inversely proportional to the silanol quantity. The difference between the absorbance of the pure solution and that of the solid - free filtrate was related to the silica weight, yielding a quantitative analysis of these groups.
Resumo:
A flow system based on multicommutation and binary sampling process was developed to implement the sample zone trapping technique in order to increase the spectrophotometric analytical range and to improve sensitivity. The flow network was designed with active devices in order to provide facilities to determine sequentialy analyte with a wide concentration range, employing a single pumping channel to propel sample and reagents solutions. The procedure was employed to determine ortophosphate ions in water samples of river and waste. Profitable features such as an analytical throughput of 60 samples determination per hour, relative standard deviation (r.s.d.) of 2% (n = 6) for a typical sample with concentration of 2.78 mg/L were achieved. By applying the paired t-test no significant difference at 95% confidence level was observed between the results obtained with the proposed system and those of the usual flow injection system.
Resumo:
The most common difficulties which occur in trace analysis are those which involve contamination, mainly when the measurement is at very low concentration of ubiquitous elements as aluminium. The worst situation is when a separation step is necessary, because it requires extra-manipulations of the sample. This article describes the degree of contamination and its control for the aluminium trace analysis in dialysis solutions, when aluminium content of about 15 µg/l must be determinated.
Resumo:
The Potentiometric Stripping Analysis (PSA) is described with emphasis on ultramicroelectrode applications with a laboratory developed computer based instrumentation. The technique potentialities as compared with the voltammetric approach are pointed out based on the current literature. Some results of trace metals analysis including zinc, cadmium, lead and copper in vinegar and canned food samples are presented. The mainly advantage found in our laboratory was the technique capability to analyse natural samples with minimum matrix interference and the low level of noise found in our determinations.
Resumo:
The determination of zirconium-hafnium mixtures is one of the most critical problem of the analytical chemistry, on account of the close similarity of their chemical properties. The spectrophotometric determination proposed by Yagodin et al. show not many practical applications due to the significant spectral interference on the 200-220 nm region. In this work we propound the use of a multivariate calibration method called partial least squares ( PLS ) for colorimetric determination of these mixtures. By using PLS and 16 calibration mixtures we obtained a model which permits determination of zirconium and hafnium with accuracy of about 1-2% and 10-20%, respectively. Using conventional univariate calibration the inaccuracy of the determination is about 10-25% for zirconium and above 57% for hafnium.
Resumo:
Capillary electrophoresis (CE) encompasses a number of characteristics quite suitable for the simultaneous analysis of small ions such as high efficiency and resolving power, directly associated to its impressively high peak capacity, and short analysis time. In appropriate conditions, it is possible to perform the separation of approximately 36 anions in less than 3 minutes. In this work, the mechanisms by which anion analysis is performed was criteriously discussed, and a thorough review of the literature in the past 5 years, focusing mostly in applications of CE to anion analysis in real matrices, was presented.
Resumo:
Results of two intercomparison exercises are reported. In the first one, the participants were asked to determine Cd, Cu, Pb and Zn, at the sub mg mL-1 level, in an acidified aqueous solution. In the second one, the participants were asked to determine mercury (total) in two homogeneous biological samples, hair and fish. The exercises were considered satisfactory and few reported results were discharged (3s criteria).
Resumo:
The plasma etching of semiconductor surfaces with fluorine-containing compounds has technological interest. Presently, considerable effort is being devoted to understand the chemistry involved. In this work, a numerical modeling analysis of the gas-phase decomposition of CF4/O2 mixtures, in the presence of silicon, was performed. The relative importance of individual processes was determined as well as the effect of the parameters' uncertainties. The results were compared with experimental data. The main etching agent in the system is the fluorine atom. The concentration of the main species, SiF4, CO, CO2 and COF2 depend on the composition of the mixture.
Resumo:
In this work, a numerical modeling analysis of the gas-phase decomposition of SF6 / O2 mixtures, in the presence of silicon, was performed. The relative importance of individual processes and the effect of the parameters' uncertainties were determined. The model was compared with experimental data for the plasma etching of silicon and with the calculated results for the CF4 / O2 system. In both systems the main etching agent is the fluorine atom and the concentration of the major species depends on the composition of the mixture. The etching rate is greater for SF6 / O2.
Resumo:
A flow system procedure for spectrophotometric determination of ascorbic acid in drugs based on [Fe3+(SCN-)n]+3-n complex decomposition by reduction is described. The flow network was constituted by a set of three-way solenoid valves, controlled by a microcomputer running a software wrote in QuickBasic 4.5 language. The feasibility of the procedure was ascertained by determining ascorbic acid in drug samples with mass ranging from 0.0018 up to 0.0180 g. The results showed an agreement of about 7% when compared with recommended method. Other profitable features such as a standard deviation of 1.5% (n = 7) and a throughput of 120 determinations per hour was also achieved.
Resumo:
In this way it is very important to know the sulfate concentration in vinasse samples before to make the biodigestor design. A previous developed and indirect method (Anal. Chim. Acta. 1996, 329, 197), was used to determine sulfate in samples of vinasse, after previous treatments, done in order to eliminate organic matter with hydrogen peroxide 30% and concentrated nitric acid mixture (3:1), under heating. Interferent cationic ions were isolated by using ion exchange columns. The results obtained for some samples from Araraquara and Penápolis are here presented. The phosphate concentration was also determined.
Resumo:
A method for the determination of phosphorus in steel samples by graphite furnace atomic absorption spectrometry, using the Zeeman effect background correction and the STPF conditions is proposed. The effect of iron (III) on the phosphorus signal was studied. It was verified, through the pyrolysis temperature curves, that iron (III) is an efficient chemical modifier, thermically stabilizing phosphorus up to 1400ºC. The phosphorus signal increases with the iron (III) concentration, but in the range, which corresponds to the usual concentrations of iron in the sample solutions, the increase is small. Phosphorus was determined in three standard reference materials, after its dissolution in a mixture of hydrochloric and perchloric acids in a PTFE bomb. The agreement with the certified concentration values was excellent. Iron (III) was added to the reference analytical solutions prepared in the blank of the dissolution, while the sample solutions were measured directly, since they already contained the modifier. The detection limit (k = 2) was 0.0042% of phosphorus in the steel sample.
Resumo:
The simultaneous determination of cobalt and nickel is a classical analytical problem. A great number of reagents associated with several techniques of analysis have been applied to achieve this determination. In this review 117 references, which appeared between 1996-1980, are described and classified according to the technique applied.