846 resultados para barium ferrite


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Flow injection (FI) methodology, using diffuse reflectance in the visible region of the spectrum, for the analysis of total sulfur in the form of sulfate, precipitated in the form of barium sulfate, is presented. The method was applied to biodiesel, to plant leaves and to natural waters analysis. The analytical signal (S) correlates linearly with sulfate concentration (C) between 20 and 120 ppm, through the equation S=-1.138+0.0934 C (r = 0.9993). The experimentally observed limit of detection is about 10 ppm. The mean R.S.D. is about 3.0 %. Real samples containing sulfate were analyzed and the results obtained by the FI and by the reference batch turbidimetric method using the statistical Student's t-test and F-test were compared.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A case of gastrocolic fistula(GCF) in a patient with duodenal stenosis who had previously undergone gastroenteric anastomosis is reported. The patient went through hemigastrectomy, partial colectomy and segmental enterectomy with bloc resection. Reconstruction was carried out through Billroth II gastrojejunostomy, jejunojejunostomy and end-to-end anastomosis of the colon. The patient had good post-operative evolution and was discharged from hospital seven days after surgery. GCF should be suspected in patients presenting weight loss, diarrhea and fecal vomiting, mainly with history of peptic ulcer surgery, gastric or colonic malignancy and use of steroidal and nonsteroidal antiinflamatory drugs. Barium enema is the choice test for diagnosis, however, the benign or malignant nature of the lesion should always be evaluated through high digestive endoscopy. Clinical treatment with oral H2-antagonists and discontinuing ulcerogenic medications might be indicated in some cases; surgical treatment is indicated in cases of malignant disease and might be indicated in cases of peptic disease as it treats GCF and also the baseline disease. Some advise upwards colostomy at first. The most used technique is bloc resection, including the fistulous tract, hemigastrectomy and partial colectomy. Gastrectomy, fistulous tract excision and colon suturing may be performed in some cases. The mortality rate is related to metabolic disorders and the recurrence with the use of antiinflammatory drugs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report a case of a 49 years-old man who underwent a barium meal examination for an epigastric pain. A perforated gastric ulcer with barium extravasation into peritoneal cavity was seen on X-rays. During an emergency laparotomy, a perforated pyloric ulcer was noted, along with barium contamination in the peritoneal cavity. The ulcer was closed with an omental patch and an extensive peritoneal lavage with saline was performed. During the postoperative period, the patient developed signs of peritonitis and underwent a new laparotomy was at the 9th day showing a subfrenic abscess with a large barium contamination. The patient presented septic shock and multiple organ failure. dying on the 21th day.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This report describes three cases of esophageal leiomyomas successfully resected by thoracoscopy. Surgical enucleation through minimally invasive surgery is the treatment of choice for esophageal leiomyoma. The conventional approach through a formal thoracotomy has the potential of causing excessive pain and patient discomfort. Moreover, the hospital stay and the recovery period are prolonged. Indications for surgery were based mainly on the size of the mass (<4 cm) and the presence of dysphagia. In one case there was a clear suspicion of malignancy. The tumour was located in the lower thoracic esophagus (case 1), in the middle thoracic esophagus (case 2) and in the upper esophagus (case 3). The CT was useful in identifying the relationship between the lesion and the organs of the mediastinum. The barium swallow study was able to locate the lesion along the esophagus. The endosonography determined the boundaries of the lesions. A right thoracoscopic approach was undertaken. Dissection of the esophagus around its entire perimeter was never necessary because all tumours were anterior or right sided. The tumours were better grasped with a traction suture than with forceps. The hidrodissection was very helpful. The water-soluble contrast swallow, performed on the fourth postoperative day, was normal. Clinical results were satisfactory in all patients. Biopsies should never be performed when the mucosa overlying is normal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present case (77 years-old woman), the diagnosis on an extramucosal lesion by endosonography was leiomyoma or schwanoma. Radiological exam of the upper digestive tract with barium and abdominal computed tomography confirmed the site of the lesion at the level of the lesser curvature. The operative technique followed the steps of the laparoscopic partial gastric resection (wedge resection) for gastric mesenchymal tumours, described elsewhere. The Endo-GIA stapler was introduced through the 12mm port in the right upper quadrant. Proper positioning of the stapler over the lesser curvature and a satisfactory margin of tissue around the mass were attained. Nine sequential firings of the Endo-GIA 30 were needed to completely surround the mass. Histopathological diagnosis was a spindle-cell tumour measuring 3cm in diameter. Mitotic index was measured at almost null. The neoplastic cells were strongly reactive for vimentine and CD34 and negative for the immunohistochemical markers S-100 protein, muscle actin, desmin and Ag linked to VIII factor. There was a slight reaction with keratin (+/+++). The XIIIA factor reaction revealed less than 5% of dendritic elements. These data favour a vascular cell origin better than smooth muscle cell origin. In conclusion it was a gastric hemangiopericytoma. Follow-up showed no recurrence at seven years.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In ship and offshore terminal construction, welded cross sections are thick and the number of welds very high. Consequently, there are two aspects of great importance; cost and heat input. Reduction in the welding operation time decreases the costs of the work force and avoids excessive heat, preventing distortion and other weld defects. The need to increase productivity while using a single wire in the GMAW process has led to the use of a high current and voltage to improve the melting rate. Unfortunately, this also increases the heat input. Innovative GMAW processes, mostly implemented for sheet plate sections, have shown significant reduction in heat input (Q), low distortion and increase in welding speed. The aim of this study is to investigate adaptive pulsed GMAW processes and assess relevant applications in the high power range, considering possible benefits when welding thicker sections and high yield strength steel. The study experimentally tests the usability of adaptive welding processes and evaluates their effects on weld properties, penetration and shapes of the weld bead.The study first briefly reviews adaptive GMAW to evaluate different approaches and their applications and to identify benefits in adaptive pulsed. Experiments are then performed using Synergic Pulsed GMAW, WiseFusionTM and Synergic GMAW processes to weld a T-joint in a horizontal position (PB). The air gap between the parts ranges from 0 to 2.5 mm. The base materials are structural steel grade S355MC and filler material G3Si1. The experiment investigates heat input, mechanical properties and microstructure of the welded joint. Analysis of the literature reveals that different approaches have been suggested using advanced digital power sources with accurate waveform, current, voltage, and feedback control. In addition, studies have clearly indicated the efficiency of lower energy welding processes. Interest in the high power range is growing and a number of different approaches have been suggested. The welding experiments in this study reveal a significant reduction of heat input and a weld microstructure with the presence of acicular ferrite (AF) beneficial for resistance to crack propagation. The WiseFusion bead had higher dilution, due to the weld bead shape, and low defects. Adaptive pulse GMAW processes can be a favoured choice when welding structures with many welded joints. The total heat reduction mitigates residual stresses and the bead shape allows a higher amperage limit. The stability of the arc during the process is virtually spatter free and allows an increase in welding speed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Opinnäytetyö on osa Arctic Materials Technologies Development -projektia, jonka tavoitteena on kehittää perusteita arktisten alueiden sovelluksiin suunnittelun ja valmistuksen kannalta. Arktisella alueella sijaitsee useita potentiaalisia öljy- ja maakaasuesiintymiä, joiden hyödyn-täminen tulee vuosi vuodelta kannattavammaksi ilmaston lämpenemisestä johtuvan merijään heikkenemisen vuoksi. Alin suunnittelulämpötila arktisilla alueilla on -60 °C, mikä aiheuttaa haasteita sekä materiaalinvalinnalle että hitsaukselle. Ferriittisillä teräksillä esiintyy lämpötilasta riippuvaa sitkeyden vaihtelua, jota kutsutaan transi-tiokäyttäytymiseksi. Lämpötilan laskiessa teräksen iskusitkeys sekä murtumissitkeys laske-vat. Arktisissa sovelluskohteissa käytetään yleisesti niukkaseosteisia, mikroseostettuja hie-noraeteräksiä, joille on ominaista erinomaiset sitkeys-, lujuus- sekä hitsattavuusominaisuudet vaativissakin olosuhteissa. Lujat termomekaanisesti valssatut ja nuorrutetut hienoraeteräkset kattavat myötölujuusluokat 355…700 MPa. Tutkimuksissa on saatu vaihtelevia tuloksia ma-teriaalien isku- ja murtumissitkeydestä -60 °C:ssa. Erityisesti sitkeysominaisuudet hitsiaineen ja muutosvyöhykkeen alueiden välillä ovat vaihtelevia. Pienemmällä lämmöntuonnilla ja seostetuilla lisäaineilla saavutetaan kuitenkin pääsääntöisesti parempia sitkeysarvoja. Asiku-laarinen ferriitti sekä alabainiitti ovat toivottavia mikrorakenteita liitoksessa, niiden pienen raekoon johdosta.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This doctoral thesis describes the development work performed on the leachand purification sections in the electrolytic zinc plant in Kokkola to increase the efficiency in these two stages, and thus the competitiveness of the plant. Since metallic zinc is a typical bulk product, the improvement of the competitiveness of a plant was mostly an issue of decreasing unit costs. The problems in the leaching were low recovery of valuable metals from raw materials, and that the available technology offered complicated and expensive processes to overcome this problem. In the purification, the main problem was consumption of zinc powder - up to four to six times the stoichiometric demand. This reduced the capacity of the plant as this zinc is re-circulated through the electrolysis, which is the absolute bottleneck in a zinc plant. Low selectivity gave low-grade and low-value precipitates for further processing to metallic copper, cadmium, cobalt and nickel. Knowledge of the underlying chemistry was poor and process interruptions causing losses of zinc production were frequent. Studies on leaching comprised the kinetics of ferrite leaching and jarosite precipitation, as well as the stability of jarosite in acidic plant solutions. A breakthrough came with the finding that jarosite could precipitate under conditions where ferrite would leach satisfactorily. Based on this discovery, a one-step process for the treatment of ferrite was developed. In the plant, the new process almost doubled the recovery of zinc from ferrite in the same equipment as the two-step jarosite process was operated in at that time. In a later expansion of the plant, investment savings were substantial compared to other technologies available. In the solution purification, the key finding was that Co, Ni, and Cu formed specific arsenides in the “hot arsenic zinc dust” step. This was utilized for the development of a three-step purification stage based on fluidized bed technology in all three steps, i.e. removal of Cu, Co and Cd. Both precipitation rates and selectivity increased, which strongly decreased the zinc powder consumption through a substantially suppressed hydrogen gas evolution. Better selectivity improved the value of the precipitates: cadmium, which caused environmental problems in the copper smelter, was reduced from 1-3% reported normally down to 0.05 %, and a cobalt cake with 15 % Co was easily produced in laboratory experiments in the cobalt removal. The zinc powder consumption in the plant for a solution containing Cu, Co, Ni and Cd (1000, 25, 30 and 350 mg/l, respectively), was around 1.8 g/l; i.e. only 1.4 times the stoichiometric demand – or, about 60% saving in powder consumption. Two processes for direct leaching of the concentrate under atmospheric conditions were developed, one of which was implemented in the Kokkola zinc plant. Compared to the existing pressure leach technology, savings were obtained mostly in investment. The scientific basis for the most important processes and process improvements is given in the doctoral thesis. This includes mathematical modeling and thermodynamic evaluation of experimental results and hypotheses developed. Five of the processes developed in this research and development program were implemented in the plant and are still operated. Even though these processes were developed with the focus on the plant in Kokkola, they can also be implemented at low cost in most of the zinc plants globally, and have thus a great significance in the development of the electrolytic zinc process in general.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This doctoral thesis introduces an improved control principle for active du/dt output filtering in variable-speed AC drives, together with performance comparisons with previous filtering methods. The effects of power semiconductor nonlinearities on the output filtering performance are investigated. The nonlinearities include the timing deviation and the voltage pulse waveform distortion in the variable-speed AC drive output bridge. Active du/dt output filtering (ADUDT) is a method to mitigate motor overvoltages in variable-speed AC drives with long motor cables. It is a quite recent addition to the du/dt reduction methods available. This thesis improves on the existing control method for the filter, and concentrates on the lowvoltage (below 1 kV AC) two-level voltage-source inverter implementation of the method. The ADUDT uses narrow voltage pulses having a duration in the order of a microsecond from an IGBT (insulated gate bipolar transistor) inverter to control the output voltage of a tuned LC filter circuit. The filter output voltage has thus increased slope transition times at the rising and falling edges, with an opportunity of no overshoot. The effect of the longer slope transition times is a reduction in the du/dt of the voltage fed to the motor cable. Lower du/dt values result in a reduction in the overvoltage effects on the motor terminals. Compared with traditional output filtering methods to accomplish this task, the active du/dt filtering provides lower inductance values and a smaller physical size of the filter itself. The filter circuit weight can also be reduced. However, the power semiconductor nonlinearities skew the filter control pulse pattern, resulting in control deviation. This deviation introduces unwanted overshoot and resonance in the filter. The controlmethod proposed in this thesis is able to directly compensate for the dead time-induced zero-current clamping (ZCC) effect in the pulse pattern. It gives more flexibility to the pattern structure, which could help in the timing deviation compensation design. Previous studies have shown that when a motor load current flows in the filter circuit and the inverter, the phase leg blanking times distort the voltage pulse sequence fed to the filter input. These blanking times are caused by excessively large dead time values between the IGBT control pulses. Moreover, the various switching timing distortions, present in realworld electronics when operating with a microsecond timescale, bring additional skew to the control. Left uncompensated, this results in distortion of the filter input voltage and a filter self-induced overvoltage in the form of an overshoot. This overshoot adds to the voltage appearing at the motor terminals, thus increasing the transient voltage amplitude at the motor. This doctoral thesis investigates the magnitude of such timing deviation effects. If the motor load current is left uncompensated in the control, the filter output voltage can overshoot up to double the input voltage amplitude. IGBT nonlinearities were observed to cause a smaller overshoot, in the order of 30%. This thesis introduces an improved ADUDT control method that is able to compensate for phase leg blanking times, giving flexibility to the pulse pattern structure and dead times. The control method is still sensitive to timing deviations, and their effect is investigated. A simple approach of using a fixed delay compensation value was tried in the test setup measurements. The ADUDT method with the new control algorithm was found to work in an actual motor drive application. Judging by the simulation results, with the delay compensation, the method should ultimately enable an output voltage performance and a du/dt reduction that are free from residual overshoot effects. The proposed control algorithm is not strictly required for successful ADUDT operation: It is possible to precalculate the pulse patterns by iteration and then for instance store them into a look-up table inside the control electronics. Rather, the newly developed control method is a mathematical tool for solving the ADUDT control pulses. It does not contain the timing deviation compensation (from the logic-level command to the phase leg output voltage), and as such is not able to remove the timing deviation effects that cause error and overshoot in the filter. When the timing deviation compensation has to be tuned-in in the control pattern, the precalculated iteration method could prove simpler and equally good (or even better) compared with the mathematical solution with a separate timing compensation module. One of the key findings in this thesis is the conclusion that the correctness of the pulse pattern structure, in the sense of ZCC and predicted pulse timings, cannot be separated from the timing deviations. The usefulness of the correctly calculated pattern is reduced by the voltage edge timing errors. The doctoral thesis provides an introductory background chapter on variable-speed AC drives and the problem of motor overvoltages and takes a look at traditional solutions for overvoltage mitigation. Previous results related to the active du/dt filtering are discussed. The basic operation principle and design of the filter have been studied previously. The effect of load current in the filter and the basic idea of compensation have been presented in the past. However, there was no direct way of including the dead time in the control (except for solving the pulse pattern manually by iteration), and the magnitude of nonlinearity effects had not been investigated. The enhanced control principle with the dead time handling capability and a case study of the test setup timing deviations are the main contributions of this doctoral thesis. The simulation and experimental setup results show that the proposed control method can be used in an actual drive. Loss measurements and a comparison of active du/dt output filtering with traditional output filtering methods are also presented in the work. Two different ADUDT filter designs are included, with ferrite core and air core inductors. Other filters included in the tests were a passive du/dtfilter and a passive sine filter. The loss measurements incorporated a silicon carbide diode-equipped IGBT module, and the results show lower losses with these new device technologies. The new control principle was measured in a 43 A load current motor drive system and was able to bring the filter output peak voltage from 980 V (the previous control principle) down to 680 V in a 540 V average DC link voltage variable-speed drive. A 200 m motor cable was used, and the filter losses for the active du/dt methods were 111W–126 W versus 184 W for the passive du/dt. In terms of inverter and filter losses, the active du/dt filtering method had a 1.82-fold increase in losses compared with an all-passive traditional du/dt output filter. The filter mass with the active du/dt method was 17% (2.4 kg, air-core inductors) compared with 14 kg of the passive du/dt method filter. Silicon carbide freewheeling diodes were found to reduce the inverter losses in the active du/dt filtering by 18% compared with the same IGBT module with silicon diodes. For a 200 m cable length, the average peak voltage at the motor terminals was 1050 V with no filter, 960 V for the all-passive du/dt filter, and 700 V for the active du/dt filtering applying the new control principle.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Viime vuosien aikana tapahtunut nikkelin hinnan nouseminen on vaikuttanut austeniittis-ferriittisten ruostumattomien terästen, ns. duplex -terästen kehittämiseen. Niukkaseosteisemmissa lean duplex -teräksissä seostetun nikkelin määrää on vähennetty ja sitä on korvattu typellä ja mangaanilla. Nämä muutokset ko. terästen seostuksessa aiheuttavat haasteita hitsaukselle, erityisesti austeniitti-ferriitti -suhteen säilyttämisessä, sekä sitä kautta iskusitkeyden ja korroosio-ominaisuuksien säilyttämiselle. Suurempi typen osuus myös lisää teräksen hitsisulan viskositeettia, mikä heikentää juuripalkojen hitsauksessa tunkeumaa. Tässsä diplomityössä on tutkittu keinoja helpottaa paksujen (yli 20 mm) lean duplex -teräslevyjen hitsausta käytännön näkökulmasta, sekä parantaa hitsattujen levyjen iskusitkeyttä. Hitsauskokeilla löydettiin hitsausta helpottavia menetelmiä ja kokeista saatiin karsimalla valikoitua hitsausarvot, joilla pystytään hitsaamaan painelaitedirektiivin mukaisesti hyväksyttäviä hitsejä lean duplex -laatuihin LDX2101 ja UR2202.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electrical machine drives are the most electrical energy-consuming systems worldwide. The largest proportion of drives is found in industrial applications. There are, however many other applications that are also based on the use of electrical machines, because they have a relatively high efficiency, a low noise level, and do not produce local pollution. Electrical machines can be classified into several categories. One of the most commonly used electrical machine types (especially in the industry) is induction motors, also known as asynchronous machines. They have a mature production process and a robust rotor construction. However, in the world pursuing higher energy efficiency with reasonable investments not every application receives the advantage of using this type of motor drives. The main drawback of induction motors is the fact that they need slipcaused and thus loss-generating current in the rotor, and additional stator current for magnetic field production along with the torque-producing current. This can reduce the electric motor drive efficiency, especially in low-speed, low-power applications. Often, when high torque density is required together with low losses, it is desirable to apply permanent magnet technology, because in this case there is no need to use current to produce the basic excitation of the machine. This promotes the effectiveness of copper use in the stator, and further, there is no rotor current in these machines. Again, if permanent magnets with a high remanent flux density are used, the air gap flux density can be higher than in conventional induction motors. These advantages have raised the popularity of PMSMs in some challenging applications, such as hybrid electric vehicles (HEV), wind turbines, and home appliances. Usually, a correctly designed PMSM has a higher efficiency and consequently lower losses than its induction machine counterparts. Therefore, the use of these electrical machines reduces the energy consumption of the whole system to some extent, which can provide good motivation to apply permanent magnet technology to electrical machines. However, the cost of high performance rare earth permanent magnets in these machines may not be affordable in many industrial applications, because the tight competition between the manufacturers dictates the rules of low-cost and highly robust solutions, where asynchronous machines seem to be more feasible at the moment. Two main electromagnetic components of an electrical machine are the stator and the rotor. In the case of a conventional radial flux PMSM, the stator contains magnetic circuit lamination and stator winding, and the rotor consists of rotor steel (laminated or solid) and permanent magnets. The lamination itself does not significantly influence the total cost of the machine, even though it can considerably increase the construction complexity, as it requires a special assembly arrangement. However, thin metal sheet processing methods are very effective and economically feasible. Therefore, the cost of the machine is mainly affected by the stator winding and the permanent magnets. The work proposed in this doctoral dissertation comprises a description and analysis of two approaches of PMSM cost reduction: one on the rotor side and the other on the stator side. The first approach on the rotor side includes the use of low-cost and abundant ferrite magnets together with a tooth-coil winding topology and an outer rotor construction. The second approach on the stator side exploits the use of a modular stator structure instead of a monolithic one. PMSMs with the proposed structures were thoroughly analysed by finite element method based tools (FEM). It was found out that by implementing the described principles, some favourable characteristics of the machine (mainly concerning the machine size) will inevitable be compromised. However, the main target of the proposed approaches is not to compete with conventional rare earth PMSMs, but to reduce the price at which they can be implemented in industrial applications, keeping their dimensions at the same level or lower than those of a typical electrical machine used in the industry at the moment. The measurement results of the prototypes show that the main performance characteristics of these machines are at an acceptable level. It is shown that with certain specific actions it is possible to achieve a desirable efficiency level of the machine with the proposed cost reduction methods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work devotes to the theoretical investigations of spin-electromagnetic waves (SEW) propagating in a thin-film multiferroic structures that were composed of a slot-line and structures with several ferrite films. In contrast to earlier works, the spin-electromagnetic waves in the investigated structures are originated from two different electrodynamics coupling. The first one is coupling of the electromagnetic wave localized mainly in the slot-line with the spin wave excited mostly in the ferrite film. The second one is coupling of two spin waves in the different ferrite films separated by a thin ferroelectric film. For theoretical analysis of SEWs propagation in such kind of structures theories of their eigen-wave spectra were developed. Spectra of SEW in the investigated structures were calculated and analyzed. The range of electric and magnetic tunability of dispersion characteristic were investigated. Spectra of SEW in the investigated multiferroic structures are used for investigation of transfer function of periodic structures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Physics professors Frans Koffyberg (right), Fereidoon Razavi (middle), and Bozidar Mitrovic (left) discover a new superconductor. A superconductor is a material that conducts electricity at very low temperatures with zero electrical resistance. The Brock researchers found that a compound of the metals Barium, Lanthanum, Copper, and Oxygen become a superconductor at 30 degrees absolute, which is a record high temperature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is well accepted that structural studies with model membranes are of considerable value in understanding the structure of biological membranes. Many studies with models of pure phospholipids have been done; but the effects of divalent cations and protein on these models would make these studies more applicable to intact membrane. The present study, performed with above view, is a structural analysis of divalent io~cardio1ipin complexes using the technique of x-ray diffraction. Cardiolipin, precipitated from dilute solution by divalent ionscalcium, magnesium and barium, contains little water and the structure formed is similar to the structure of pure cardiolipin with low water content. The calcium-cardiolipin complex forms a pure hexagonal type II phase that exists from 40 to 400 C. The molar ratio of calcium and cardiolipin in the complex is 1 : 1. Cardiolipin, precipitated with magnesium and barium forms two co-existing phases, lamellar and hexagonal, the relative quantity of the two phases being dependent on temperature. The hexagonal phase type II consisting of water filled channels formed by adding calcium to cardiolipin may have a remarkable permeability property in intact membrane. Pure cardiolipin and insulin at pH 3.0 and 4.0 precipitate but form no organised structure. Lecithin/cardiolipin and insulin precipitated at pH 3.0 give a pure lamellar phase. As the lecithin/cardiolipin molar ratio changes from 93/7 to SO/50, (a) the repeat distance of the lamellar changes from 72.8 X to 68.2 A; (b) the amount of protein bound increases in such a way that cardiolipin/insulin molar ratio in the complex reaches a maximum constant value at lecithin/cardiolipin molar ratio 70/30. A structural model based on these data shows that the molecular arrangement of lipid and protein is a lipid bilayer coated with protein molecules. The lipid-protein interaction is chiefly electrostatic and little, if any, hydrophobic bonding occurs in this particular system. So, the proposed model is essentially the same as Davson-Daniellifs model of biological membrane.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Contexte & Objectifs : La manométrie perfusée conventionnelle et la manométrie haute résolution (HRM) ont permis le développement d’une variété de paramètres pour mieux comprendre la motilité de l'œsophage et quantifier les caractéristiques de la jonction œsophago-gastrique (JOG). Cependant, l'anatomie de la JOG est complexe et les enregistrements de manométrie détectent à la fois la pression des structures intrinsèques et des structures extrinsèques à l'œsophage. Ces différents composants ont des rôles distincts au niveau de la JOG. Les pressions dominantes ainsi détectées au niveau de la JOG sont attribuables au sphincter œsophagien inférieur (SOI) et aux piliers du diaphragme (CD), mais aucune des technologies manométriques actuelles n’est capable de distinguer ces différents composants de la JOG. Lorsqu’on analyse les caractéristiques de la JOG au repos, celle ci se comporte avant tout comme une barrière antireflux. Les paramètres manométriques les plus couramment utilisés dans ce but sont la longueur de la JOG et le point d’inversion respiratoire (RIP), défini comme le lieu où le pic de la courbe de pression inspiratoire change de positif (dans l’abdomen) à négatif (dans le thorax), lors de la classique manœuvre de « pull-through ». Cependant, l'importance de ces mesures reste marginale comme en témoigne une récente prise de position de l’American Gastroenterology Association Institute (AGAI) (1) qui concluait que « le rôle actuel de la manométrie dans le reflux gastro-œsophagien (RGO) est d'exclure les troubles moteurs comme cause des symptômes présentés par la patient ». Lors de la déglutition, la mesure objective de la relaxation de la JOG est la pression de relaxation intégrée (IRP), qui permet de faire la distinction entre une relaxation normale et une relaxation anormale de la JOG. Toutefois, puisque la HRM utilise des pressions moyennes à chaque niveau de capteurs, certaines études de manométrie laissent suggérer qu’il existe une zone de haute pression persistante au niveau de la JOG même si un transit est mis en évidence en vidéofluoroscopie. Récemment, la manométrie haute résolution « 3D » (3D-HRM) a été développée (Given Imaging, Duluth, GA) avec le potentiel de simplifier l'évaluation de la morphologie et de la physiologie de la JOG. Le segment « 3D » de ce cathéter de HRM permet l'enregistrement de la pression à la fois de façon axiale et radiale tout en maintenant une position fixe de la sonde, et évitant ainsi la manœuvre de « pull-through ». Par conséquent, la 3D-HRM devrait permettre la mesure de paramètres importants de la JOG tels que sa longueur et le RIP. Les données extraites de l'enregistrement fait par 3D-HRM permettraient également de différencier les signaux de pression attribuables au SOI des éléments qui l’entourent. De plus, l’enregistrement des pressions de façon radiaire permettrait d’enregistrer la pression minimale de chaque niveau de capteurs et devrait corriger cette zone de haute pression parfois persistante lors la déglutition. Ainsi, les objectifs de ce travail étaient: 1) de décrire la morphologie de la JOG au repos en tant que barrière antireflux, en comparant les mesures effectuées avec la 3D-HRM en temps réel, par rapport à celle simulées lors d’une manœuvre de « pull-through » et de déterminer quelles sont les signatures des pressions attribuables au SOI et au diaphragme; 2) d’évaluer la relaxation de la JOG pendant la déglutition en testant l'hypothèse selon laquelle la 3D-HRM permet le développement d’un nouveau paradigme (appelé « 3D eSleeve ») pour le calcul de l’IRP, fondé sur l’utilisation de la pression radiale minimale à chaque niveau de capteur de pression le long de la JOG. Ce nouveau paradigme sera comparé à une étude de transit en vidéofluoroscopie pour évaluer le gradient de pression à travers la JOG. Méthodes : Nous avons utilisé un cathéter 3D-HRM, qui incorpore un segment dit « 3D » de 9 cm au sein d’un cathéter HRM par ailleurs standard. Le segment 3D est composé de 12 niveaux (espacés de 7.5mm) de 8 capteurs de pression disposés radialement, soit un total de 96 capteurs. Neuf volontaires ont été étudiés au repos, où des enregistrements ont été effectués en temps réel et pendant une manœuvre de « pull-through » du segment 3D (mobilisation successive du cathéter de 5 mm, pour que le segment 3D se déplace le long de la JOG). Les mesures de la longueur du SOI et la détermination du RIP ont été réalisées. La longueur de la JOG a été mesurée lors du « pull-through » en utilisant 4 capteurs du segment 3D dispersés radialement et les marges de la JOG ont été définies par une augmentation de la pression de 2 mmHg par rapport à la pression gastrique ou de l’œsophage. Pour le calcul en temps réel, les limites distale et proximale de la JOG ont été définies par une augmentation de pression circonférentielle de 2 mmHg par rapport à la pression de l'estomac. Le RIP a été déterminée, A) dans le mode de tracé conventionnel avec la méthode du « pull-through » [le RIP est la valeur moyenne de 4 mesures] et B) en position fixe, dans le mode de représentation topographique de la pression de l’œsophage, en utilisant l’outil logiciel pour déterminer le point d'inversion de la pression (PIP). Pour l'étude de la relaxation de la JOG lors de la déglutition, 25 volontaires ont été étudiés et ont subi 3 études de manométrie (10 déglutitions de 5ml d’eau) en position couchée avec un cathéter HRM standard et un cathéter 3D-HRM. Avec la 3D-HRM, l’analyse a été effectuée une fois avec le segment 3D et une fois avec une partie non 3D du cathéter (capteurs standard de HRM). Ainsi, pour chaque individu, l'IRP a été calculée de quatre façons: 1) avec la méthode conventionnelle en utilisant le cathéter HRM standard, 2) avec la méthode conventionnelle en utilisant le segment standard du cathéter 3D-HRM, 3) avec la méthode conventionnelle en utilisant le segment « 3D » du cathéter 3D-HRM, et 4) avec le nouveau paradigme (3D eSleeve) qui recueille la pression minimale de chaque niveau de capteurs (segment 3D). Quatorze autres sujets ont subi une vidéofluoroscopie simultanée à l’étude de manométrie avec le cathéter 3D-HRM. Les données de pression ont été exportés vers MATLAB ™ et quatre pressions ont été mesurées simultanément : 1) la pression du corps de l’œsophage, 2cm au-dessus de la JOG, 2) la pression intragastrique, 3) la pression radiale moyenne de la JOG (pression du eSleeve) et 4) la pression de la JOG en utilisant la pression minimale de chaque niveau de capteurs (pression du 3D eSleeve). Ces données ont permis de déterminer le temps permissif d'écoulement du bolus (FPT), caractérisé par la période au cours de laquelle un gradient de pression existe à travers la JOG (pression œsophagienne > pression de relaxation de la JOG > pression gastrique). La présence ou l'absence du bolus en vidéofluoroscopie et le FPT ont été codés avec des valeurs dichotomiques pour chaque période de 0,1 s. Nous avons alors calculé la sensibilité et la spécificité correspondant à la valeur du FPT pour la pression du eSleeve et pour la pression du 3D eSleeve, avec la vidéofluoroscopie pour référence. Résultats : Les enregistrements avec la 3D-HRM laissent suggérer que la longueur du sphincter évaluée avec la méthode du « pull-through » était grandement exagéré en incorporant dans la mesure du SOI les signaux de pression extrinsèques à l’œsophage, asymétriques et attribuables aux piliers du diaphragme et aux structures vasculaires. L’enregistrement en temps réel a permis de constater que les principaux constituants de la pression de la JOG au repos étaient attribuables au diaphragme. L’IRP calculé avec le nouveau paradigme 3D eSleeve était significativement inférieur à tous les autres calculs d'IRP avec une limite supérieure de la normale de 12 mmHg contre 17 mmHg pour l’IRP calculé avec la HRM standard. La sensibilité (0,78) et la spécificité (0,88) du 3D eSleeve étaient meilleurs que le eSleeve standard (0,55 et 0,85 respectivement) pour prédire le FPT par rapport à la vidéofluoroscopie. Discussion et conclusion : Nos observations suggèrent que la 3D-HRM permet l'enregistrement en temps réel des attributs de la JOG, facilitant l'analyse des constituants responsables de sa fonction au repos en tant que barrière antireflux. La résolution spatiale axiale et radiale du segment « 3D » pourrait permettre de poursuivre cette étude pour quantifier les signaux de pression de la JOG attribuable au SOI et aux structures extrinsèques (diaphragme et artéfacts vasculaires). Ces attributs du cathéter 3D-HRM suggèrent qu'il s'agit d'un nouvel outil prometteur pour l'étude de la physiopathologie du RGO. Au cours de la déglutition, nous avons évalué la faisabilité d’améliorer la mesure de l’IRP en utilisant ce nouveau cathéter de manométrie 3D avec un nouveau paradigme (3D eSleeve) basé sur l’utilisation de la pression radiale minimale à chaque niveau de capteurs de pression. Nos résultats suggèrent que cette approche est plus précise que celle de la manométrie haute résolution standard. La 3D-HRM devrait certainement améliorer la précision des mesures de relaxation de la JOG et cela devrait avoir un impact sur la recherche pour modéliser la JOG au cours de la déglutition et dans le RGO.