929 resultados para Visualization technique
Resumo:
We describe an improved multiple-locus variable-number tandem-repeat (VNTR) analysis (MLVA) scheme for genotyping Staphylococcus aureus. We compare its performance to those of multilocus sequence typing (MLST) and spa typing in a survey of 309 strains. This collection includes 87 epidemic methicillin-resistant S. aureus (MRSA) strains of the Harmony collection, 75 clinical strains representing the major MLST clonal complexes (CCs) (50 methicillin-sensitive S. aureus [MSSA] and 25 MRSA), 135 nasal carriage strains (133 MSSA and 2 MRSA), and 13 published S. aureus genome sequences. The results show excellent concordance between the techniques' results and demonstrate that the discriminatory power of MLVA is higher than those of both MLST and spa typing. Two hundred forty-two genotypes are discriminated with 14 VNTR loci (diversity index, 0.9965; 95% confidence interval, 0.9947 to 0.9984). Using a cutoff value of 45%, 21 clusters are observed, corresponding to the CCs previously defined by MLST. The variability of the different tandem repeats allows epidemiological studies, as well as follow-up of the evolution of CCs and the identification of potential ancestors. The 14 loci can conveniently be analyzed in two steps, based upon a first-line simplified assay comprising a subset of 10 loci (panel 1) and a second subset of 4 loci (panel 2) that provides higher resolution when needed. In conclusion, the MLVA scheme proposed here, in combination with available on-line genotyping databases (including http://mlva.u-psud.fr/), multiplexing, and automatic sizing, can provide a basis for almost-real-time large-scale population monitoring of S. aureus.
Resumo:
PURPOSE: To describe the use of anterior segment optical coherence tomography (AS-OCT) to clarify the position and patency of aqueous shunt devices in the anterior chamber of eyes where corneal edema or tube position does not permit a satisfactory view. DESIGN: Noncomparative observational case series. METHODS: Four cases are reported in which aqueous shunt malposition or obstruction was suspected but the shunt could not be seen on clinical examination. The patients underwent AS-OCT to identify the position and patency of the shunt tip. RESULTS: In each case, AS-OCT provided data regarding tube position and/or patency that could not be obtained by slit-lamp examination or by gonioscopy that influenced management. CONCLUSIONS: AS-OCT can be used to visualize anterior chamber tubes in the presence of corneal edema that precludes an adequate view or in cases where the tube is retracted into the cornea. In such cases, AS-OCT is useful in identifying shunt patency and position, which helps guide clinical decision making.
Resumo:
A cardiac-triggered, free-breathing, 3D balanced FFE projection renal MR angiography (MRA) technique with a 2D pencil beam aortic labeling pulse for selective aortic spin tagging was developed. For respiratory motion artifact suppression during free breathing, a prospective real-time navigator was implemented for renal MRA. Images obtained with the new approach were compared with standard contrast-enhanced (CE) 3D breath-hold MRA in seven swine. Signal properties and vessel visualization were analyzed. With the presented technique, high-resolution, high-contrast renal projection MRA with superior vessel length visualization (including a greater visible number of distal branches of the renal arteries) compared to standard breath-hold CE-MRA was obtained. The present results warrant clinical studies in patients with renal artery disease.
Resumo:
BACKGROUND: The goal of this study was to characterize the performance of fluorine-19 ((19)F) cardiac magnetic resonance (CMR) for the specific detection of inflammatory cells in a mouse model of myocarditis. Intravenously administered perfluorocarbons are taken up by infiltrating inflammatory cells and can be detected by (19)F-CMR. (19)F-labeled cells should, therefore, generate an exclusive signal at the inflamed regions within the myocardium. METHODS AND RESULTS: Experimental autoimmune myocarditis was induced in BALB/c mice. After intravenous injection of 2×200 µL of a perfluorocarbon on day 19 and 20 (n=9) after immunization, in vivo (19)F-CMR was performed at the peak of myocardial inflammation (day 21). In 5 additional animals, perfluorocarbon combined with FITC (fluorescein isothiocyanate) was administered for postmortem immunofluorescence and flow-cytometry analyses. Control experiments were performed in 9 animals. In vivo (19)F-CMR detected myocardial inflammation in all experimental autoimmune myocarditis-positive animals. Its resolution was sufficient to identify even small inflammatory foci, that is, at the surface of the right ventricle. Postmortem immunohistochemistry and flow cytometry confirmed the presence of perfluorocarbon in macrophages, dendritic cells, and granulocytes, but not in lymphocytes. The myocardial volume of elevated (19)F signal (rs=0.96; P<0.001), the (19)F signal-to-noise ratio (rs=0.92; P<0.001), and the (19)F signal integral (rs=0.96; P<0.001) at day 21 correlated with the histological myocarditis severity score. CONCLUSIONS: In vivo (19)F-CMR was successfully used to visualize the inflammation specifically and robustly in experimental autoimmune myocarditis, and thus allowed for an unprecedented insight into the involvement of inflammatory cells in the disease process.
Resumo:
Introduction: The field of Connectomic research is growing rapidly, resulting from methodological advances in structural neuroimaging on many spatial scales. Especially progress in Diffusion MRI data acquisition and processing made available macroscopic structural connectivity maps in vivo through Connectome Mapping Pipelines (Hagmann et al, 2008) into so-called Connectomes (Hagmann 2005, Sporns et al, 2005). They exhibit both spatial and topological information that constrain functional imaging studies and are relevant in their interpretation. The need for a special-purpose software tool for both clinical researchers and neuroscientists to support investigations of such connectome data has grown. Methods: We developed the ConnectomeViewer, a powerful, extensible software tool for visualization and analysis in connectomic research. It uses the novel defined container-like Connectome File Format, specifying networks (GraphML), surfaces (Gifti), volumes (Nifti), track data (TrackVis) and metadata. Usage of Python as programming language allows it to by cross-platform and have access to a multitude of scientific libraries. Results: Using a flexible plugin architecture, it is possible to enhance functionality for specific purposes easily. Following features are already implemented: * Ready usage of libraries, e.g. for complex network analysis (NetworkX) and data plotting (Matplotlib). More brain connectivity measures will be implemented in a future release (Rubinov et al, 2009). * 3D View of networks with node positioning based on corresponding ROI surface patch. Other layouts possible. * Picking functionality to select nodes, select edges, get more node information (ConnectomeWiki), toggle surface representations * Interactive thresholding and modality selection of edge properties using filters * Arbitrary metadata can be stored for networks, thereby allowing e.g. group-based analysis or meta-analysis. * Python Shell for scripting. Application data is exposed and can be modified or used for further post-processing. * Visualization pipelines using filters and modules can be composed with Mayavi (Ramachandran et al, 2008). * Interface to TrackVis to visualize track data. Selected nodes are converted to ROIs for fiber filtering The Connectome Mapping Pipeline (Hagmann et al, 2008) processed 20 healthy subjects into an average Connectome dataset. The Figures show the ConnectomeViewer user interface using this dataset. Connections are shown that occur in all 20 subjects. The dataset is freely available from the homepage (connectomeviewer.org). Conclusions: The ConnectomeViewer is a cross-platform, open-source software tool that provides extensive visualization and analysis capabilities for connectomic research. It has a modular architecture, integrates relevant datatypes and is completely scriptable. Visit www.connectomics.org to get involved as user or developer.
Resumo:
BACKGROUND: Sclerotherapy of telangiectasias and reticular leg veins can be unpleasant and painful for some patients. OBJECTIVE: To determine pain level with two different sclerotherapy techniques in a prospective randomized trial. METHODS: Patients with symmetrical telangiectasias and reticular veins on both legs (C(1A) or (S)E(P)A(S)P(N1) were randomized to the standard (successive injections of chromated glycerin mixed with one-third lidocaine-epinephrine 1%) or two-step technique (first treating only reticular veins with a single injection at the base of each cluster of telangiectasias and then successively injecting all remaining telangiectasias a few minutes later. Pain was assessed using a 100-point visual analogue scale (0 = no pain, 100 = maximum pain). RESULTS: Data from 53 consecutive patients could be evaluated. The two-step technique was significantly less painful (28.2) than the standard technique (40.6, p < .001). CONCLUSION: The two-step technique with chromated glycerin mixed with one-third lidocaine-epinephrine 1% significantly reduces sclerotherapy pain. This may be a useful technique for patients who are particularly sensitive or afraid of sclerotherapy.
Resumo:
Solid phase microextraction (SPME) has been widely used for many years in various applications, such as environmental and water samples, food and fragrance analysis, or biological fluids. The aim of this study was to suggest the SPME method as an alternative to conventional techniques used in the evaluation of worker exposure to benzene, toluene, ethylbenzene, and xylene (BTEX). Polymethylsiloxane-carboxen (PDMS/CAR) showed as the most effective stationary phase material for sorbing BTEX among other materials (polyacrylate, PDMS, PDMS/divinylbenzene, Carbowax/divinylbenzene). Various experimental conditions were studied to apply SPME to BTEX quantitation in field situations. The uptake rate of the selected fiber (75 μm PDMS/CAR) was determined for each analyte at various concentrations, relative humidities, and airflow velocities from static (calm air) to dynamic (>200 cm/s) conditions. The SPME method also was compared with the National Institute of Occupational Safety and Health method 1501. Unlike the latter, the SPME approach fulfills the new requirement for the threshold limit value-short term exposure limit (TLV-STEL) of 2.5 ppm for benzene (8 mg/m3).
Resumo:
We report magnetic and magneto-optical measurements of two Mn12 single-molecule magnet derivatives isolated in organic glasses. Field-dependent magnetic circular dichroism (MCD) intensity curves (hysteresis cycles) are found to be essentially identical to superconducting quantum interference device magnetization results and provide experimental evidence for the potential of the optical technique for magnetic characterization. Optical observation of magnetic tunneling has been achieved by studying the decay of the MCD signal at weak applied magnetic field
Resumo:
Multi-phase postmortem CT angiography (MPMCTA) is recognized as a valuable tool to explore the vascular system, with higher sensitivity than conventional autopsy. However, a limitation is the impossibility to diagnose pulmonary embolism (PE) due to post-mortem blood clots situated in pulmonary arteries. The purpose of this study was to explore an eventual possibility to distinguish between real PE and artefacts mimicking PE. Our study included 416 medico-legal cases. All of them underwent MPMCTA, conventional autopsy and histological examination. We selected cases presenting arterial luminal filling defects in the pulmonary arteries. Their radiological interpretation was confronted to the one of autopsy and histological examination. We also investigated an eventual correlation between artefacts in pulmonary arteries and those in other parts of the vascular system. In 123 cases, filling defects of pulmonary arteries were described during MPMCTA. In 57 cases, this was interpreted as artefact and in 4 cases as suspected PE. In 62 cases only a differential diagnosis was made. Autopsy and histology could clearly identify the artefacts as such. Only one case of real PE was radiologically misinterpreted as artefact. In 6 of the 62 cases with no interpretation a PE was diagnosed. In 3 out of 4 suspected cases, PE was confirmed. We found out that filling defects in pulmonary arteries are nearly always associated to other vascular artefacts. Therefore, we suggest following some rules for radiological interpretation in order to allow a reliable diagnosis of pulmonary embolism after MPMCTA.
Resumo:
BACKGROUND: Gastric banding still represents one of the most widely used bariatric procedures. It provides acceptable weight loss in many patients, but has frequent long-term complications. Because different types of bands may lead to different results, we designed a randomized study to compare the Lapband® with the SAGB®. We hereby report on the long-term results. METHODS: Between December 1998 and June 2002, 180 morbidly obese patients were randomized between Lapband® or SAGB®. Weight loss, long-term morbidity, and need for reoperation were evaluated. RESULTS: Long-term weight loss did not differ between the two bands. Patients who maintained their band had an acceptable long-term weight loss of between 50 and 60 % EBMIL. In both groups, about half the patients developed long-term complications, with about 50 % requiring major redo surgery. There was no difference in the overall rates of long-term complications or failures between the two groups, but patients who had a Lapband® were significantly more prone to develop band slippage/pouch dilatation (13.3 versus 0 %, p < 0,001). CONCLUSIONS: Although in the absence of complication, gastric banding leads to acceptable weight loss; the long-term complication and major reoperation rates are very high independently from the type of band used or on the operative technique. Gastric banding leads to relatively poor overall long-term results and therefore should not be considered the procedure of choice for the treatment of morbid obesity. Patients should be informed of the limited overall weight loss and the very high complication rates.
Resumo:
Yhteenveto: Käytännöllinen oikeanpuoleinen viiltogastropeksia mahalaukun laajentumisen ja kiertymisen hoitona tai ennaltaehkäisynä
Resumo:
Background and objective: Asthma is one of the most frequent chronic diseases affecting children and adolescents. Good compliance is indispensable for effective treatment since a suboptimal use of inhalation devices can result in decreased therapeutic efficacy and increased morbidity. The objective of this work was to evaluate the inhalation technique of paediatric patients visiting a specialized consultation clinic of a university hospital. Design: Observational prospective study during a 3-month period. Setting Specialized consultation clinic of a university hospital. Main outcome measures: This study involved 40 outpatient infants, children and adolescents visiting alone or with their parent(s). Patients' data (age, sex, weight, diagnostic, reason for consulting, previous consultations) and their medicines were compiled using an ad hoc form. Filmed sequences of the inhalation procedure used by each child were reviewed independently by members of an interdisciplinary team consisting in a physician, a pharmacist, a nurse and a physiotherapist. A score of 1 was assigned to each correct step in the procedure, and a score of 0 to an incorrect step. A perfect procedure implied 12 correct steps. Results: Thirty patients were treated with a metered-dose inhaler and an inhalation chamber (Babyhaler or AeroChamber Plus); ten other patients were treated with a dry powder inhaler (Diskus or Turbuhaler). The agreement between the members of the interdisciplinary team was considered satisfactory. Nine patients (22.5%) reached an average score lower than 7, 18 patients (45%) a score between 7 and 10 and 13 (32.5%) a score equal to or better than 10. No patient reached the maximum score of 12. Users of the metered-dose inhalers (average score = 9.2) showed a better technique than users of the dry powder inhalers (average score = 7.4). Disappointingly, the score was not improved during a second consultation or following regular consultations. Conclusions: Video recording is a simple method to evaluate the degree of mastery of an inhalation procedure in paediatric patients. The method allows a convenient and efficient identification of suboptimal procedure steps by the hospital staff, and opens the way to patient-specific teaching. In two-thirds of juvenile patients, their inhalation technique was suboptimal despite initial training. This study shows conclusively that the inhalation technique in paediatric patients must be monitored during each examination, and teaching measures taken to improve it when necessary.
Resumo:
Objectifs: Evaluer la technique de reconstruction itérative VEO en tomodensitométrie (TDM) du thorax chez l'enfant. Matériels et méthodes: Etude prospective, basée sur 20 patients (7-18 ans), suivis pour mucoviscidose et adressés pour TDM de suivi. Dix patients (groupe A) ont eu une acquisition basse-dose habituelle (BD). Dix patients (groupe B) ont eu une acquisition très-basse-dose (TBD) et ultra-basse-dose (UBD). Les acquisitions BD étaient reconstruites par rétroprojection filtrée (RPF), les acquisitions TBD et UBD étaient reconstruites par RPF et VEO. L'évaluation de VEO était basée sur la réduction de dose et la qualité des images (mesures de bruit et scores de visualisation des structures pulmonaires). Résultats: Une réduction de dose d'environ 50% était obtenue dans le groupe B. La réduction du bruit en VEO par rapport aux RPF était de 55% en TBD et de 75% en UBD. En VEO, une amélioration des scores de visualisation des structures pulmonaires était obtenue en TBD et UBD. Cependant, en VEO-UBD, la visualisation des structures distales demeuraient parfois insuffisante et celle des structures proximales était altérée par une modification de texture de l'image. Conclusion: Malgré une altération possible de la texture de l'image en UBD, la technique de reconstruction VEO est performante en réduction de dose et amélioration des images.
3D coronary vessel wall imaging utilizing a local inversion technique with spiral image acquisition.
Resumo:
Current 2D black blood coronary vessel wall imaging suffers from a relatively limited coverage of the coronary artery tree. Hence, a 3D approach facilitating more extensive coverage would be desirable. The straightforward combination of a 3D-acquisition technique together with a dual inversion prepulse can decrease the effectiveness of the black blood preparation. To minimize artifacts from insufficiently suppressed blood signal of the nearby blood pools, and to reduce residual respiratory motion artifacts from the chest wall, a novel local inversion technique was implemented. The combination of a nonselective inversion prepulse with a 2D selective local inversion prepulse allowed for suppression of unwanted signal outside a user-defined region of interest. Among 10 subjects evaluated using a 3D-spiral readout, the local inversion pulse effectively suppressed signal from ventricular blood, myocardium, and chest wall tissue in all cases. The coronary vessel wall could be visualized within the entire imaging volume.