905 resultados para Video Surveillance System
Resumo:
BACKGROUND/RATIONALE: Patient safety is a major concern in healthcare systems worldwide. Although most safety research has been conducted in the inpatient setting, evidence indicates that medical errors and adverse events are a threat to patients in the primary care setting as well. Since information about the frequency and outcomes of safety incidents in primary care is required, the goals of this study are to describe the type, frequency, seasonal and regional distribution of medication incidents in primary care in Switzerland and to elucidate possible risk factors for medication incidents. Label="METHODS AND ANALYSIS" ="METHODS"/> <AbstractText STUDY DESIGN AND SETTING: We will conduct a prospective surveillance study to identify cases of medication incidents among primary care patients in Switzerland over the course of the year 2015. PARTICIPANTS: Patients undergoing drug treatment by 167 general practitioners or paediatricians reporting to the Swiss Federal Sentinel Reporting System. INCLUSION CRITERIA: Any erroneous event, as defined by the physician, related to the medication process and interfering with normal treatment course. EXCLUSION CRITERIA: Lack of treatment effect, adverse drug reactions or drug-drug or drug-disease interactions without detectable treatment error. PRIMARY OUTCOME: Medication incidents. RISK FACTORS: Age, gender, polymedication, morbidity, care dependency, hospitalisation. STATISTICAL ANALYSIS: Descriptive statistics to assess type, frequency, seasonal and regional distribution of medication incidents and logistic regression to assess their association with potential risk factors. Estimated sample size: 500 medication incidents. LIMITATIONS: We will take into account under-reporting and selective reporting among others as potential sources of bias or imprecision when interpreting the results. ETHICS AND DISSEMINATION: No formal request was necessary because of fully anonymised data. The results will be published in a peer-reviewed journal. TRIAL REGISTRATION NUMBER: NCT0229537.
Resumo:
QUESTION UNDER STUDY: The frequency of severe adverse drug reactions (ADRs) from psychotropic drugs was investigated in hospitalised psychiatric patients in relation to their age. Specifically, the incidence of ADRs in patients up to 60 years was compared to that of patients older than 60 years. METHODS: Prescription rates of psychotropic drugs and reports of severe ADRs were collected in psychiatric hospitals in Switzerland between 2001 and 2010. The data stem from the drug surveillance programme AMSP. RESULTS: A total of 699 patients exhibited severe ADRs: 517 out of 28,282 patients up to 60 years (1.8%); 182 out of 11,446 elderly patients (1.6%, ns). Logistic regression analyses showed a significantly negative relationship between the incidence of ADRs and patients' age in general and in particular for weight gain, extrapyramidal motor system (EPMS) symptoms, increased liver enzymes and galactorrhoea. A significantly negative relationship was observed for age and the dosages of olanzapine, quetiapine, risperidone, valproic acid and lamotrigine. When comparing age groups, frequency of ADRs was lower in general for antipsychotic drugs and anticonvulsants, in particular for valproic acid in the elderly. Weight gain was found to be lower in the elderly for antipsychotic drugs, in particular for olanzapine. For the group of mood-stabilising anticonvulsants (carbamazepine, lamotrigine and valproic acid) the elderly exhibited a lower incidence of reported allergic skin reactions. CONCLUSION: The results suggest that for psychiatric inpatients the incidence of common severe ADRs (e.g., weight gain or EPMS symptoms) arising from psychotropic medication decreases with the age of patients.
Resumo:
A visual SLAM system has been implemented and optimised for real-time deployment on an AUV equipped with calibrated stereo cameras. The system incorporates a novel approach to landmark description in which landmarks are local sub maps that consist of a cloud of 3D points and their associated SIFT/SURF descriptors. Landmarks are also sparsely distributed which simplifies and accelerates data association and map updates. In addition to landmark-based localisation the system utilises visual odometry to estimate the pose of the vehicle in 6 degrees of freedom by identifying temporal matches between consecutive local sub maps and computing the motion. Both the extended Kalman filter and unscented Kalman filter have been considered for filtering the observations. The output of the filter is also smoothed using the Rauch-Tung-Striebel (RTS) method to obtain a better alignment of the sequence of local sub maps and to deliver a large-scale 3D acquisition of the surveyed area. Synthetic experiments have been performed using a simulation environment in which ray tracing is used to generate synthetic images for the stereo system
Resumo:
This thesis considers aspects related to the design and standardisation of transmission systems for wireless broadcasting, comprising terrestrial and mobile reception. The purpose is to identify which factors influence the technical decisions and what issues could be better considered in the design process in order to assess different use cases, service scenarios and end-user quality. Further, the necessity of cross-layer optimisation for efficient data transmission is emphasised and means to take this into consideration are suggested. The work is mainly related terrestrial and mobile digital video broadcasting systems but many of the findings can be generalised also to other transmission systems and design processes. The work has led to three main conclusions. First, it is discovered that there are no sufficiently accurate error criteria for measuring the subjective perceived audiovisual quality that could be utilised in transmission system design. Means for designing new error criteria for mobile TV (television) services are suggested and similar work related to other services is recommended. Second, it is suggested that in addition to commercial requirements there should be technical requirements setting the frame work for the design process of a new transmission system. The technical requirements should include the assessed reception conditions, technical quality of service and service functionalities. Reception conditions comprise radio channel models, receiver types and antenna types. Technical quality of service consists of bandwidth, timeliness and reliability. Of these, the thesis focuses on radio channel models and errorcriteria (reliability) as two of the most important design challenges and provides means to optimise transmission parameters based on these. Third, the thesis argues that the most favourable development for wireless broadcasting would be a single system suitable for all scenarios of wireless broadcasting. It is claimed that there are no major technical obstacles to achieve this and that the recently published second generation digital terrestrial television broadcasting system provides a good basis. The challenges and opportunities of a universal wireless broadcasting system are discussed mainly from technical but briefly also from commercial and regulatory aspect
Resumo:
Actualment un típic embedded system (ex. telèfon mòbil) requereix alta qualitat per portar a terme tasques com codificar/descodificar a temps real; han de consumir poc energia per funcionar hores o dies utilitzant bateries lleugeres; han de ser el suficientment flexibles per integrar múltiples aplicacions i estàndards en un sol aparell; han de ser dissenyats i verificats en un període de temps curt tot i l’augment de la complexitat. Els dissenyadors lluiten contra aquestes adversitats, que demanen noves innovacions en arquitectures i metodologies de disseny. Coarse-grained reconfigurable architectures (CGRAs) estan emergent com a candidats potencials per superar totes aquestes dificultats. Diferents tipus d’arquitectures han estat presentades en els últims anys. L’alta granularitat redueix molt el retard, l’àrea, el consum i el temps de configuració comparant amb les FPGAs. D’altra banda, en comparació amb els tradicionals processadors coarse-grained programables, els alts recursos computacionals els permet d’assolir un alt nivell de paral•lelisme i eficiència. No obstant, els CGRAs existents no estant sent aplicats principalment per les grans dificultats en la programació per arquitectures complexes. ADRES és una nova CGRA dissenyada per I’Interuniversity Micro-Electronics Center (IMEC). Combina un processador very-long instruction word (VLIW) i un coarse-grained array per tenir dues opcions diferents en un mateix dispositiu físic. Entre els seus avantatges destaquen l’alta qualitat, poca redundància en les comunicacions i la facilitat de programació. Finalment ADRES és un patró enlloc d’una arquitectura concreta. Amb l’ajuda del compilador DRESC (Dynamically Reconfigurable Embedded System Compile), és possible trobar millors arquitectures o arquitectures específiques segons l’aplicació. Aquest treball presenta la implementació d’un codificador MPEG-4 per l’ADRES. Mostra l’evolució del codi per obtenir una bona implementació per una arquitectura donada. També es presenten les característiques principals d’ADRES i el seu compilador (DRESC). Els objectius són de reduir al màxim el nombre de cicles (temps) per implementar el codificador de MPEG-4 i veure les diferents dificultats de treballar en l’entorn ADRES. Els resultats mostren que els cícles es redueixen en un 67% comparant el codi inicial i final en el mode VLIW i un 84% comparant el codi inicial en VLIW i el final en mode CGA.
Resumo:
Paper presented at the 40th Annual Conference of LIBER (Ligue des Bibliothèques Européennes de Recherche - Association of European Research Libraries) on July 1st, 2011; with the slides used at the presentation.
Resumo:
Poster at Open Repositories 2014, Helsinki, Finland, June 9-13, 2014
Resumo:
The problem of automatic recognition of the fish from the video sequences is discussed in this Master’s Thesis. This is a very urgent issue for many organizations engaged in fish farming in Finland and Russia because the process of automation control and counting of individual species is turning point in the industry. The difficulties and the specific features of the problem have been identified in order to find a solution and propose some recommendations for the components of the automated fish recognition system. Methods such as background subtraction, Kalman filtering and Viola-Jones method were implemented during this work for detection, tracking and estimation of fish parameters. Both the results of the experiments and the choice of the appropriate methods strongly depend on the quality and the type of a video which is used as an input data. Practical experiments have demonstrated that not all methods can produce good results for real data, whereas on synthetic data they operate satisfactorily.
Resumo:
The review of intelligent machines shows that the demand for new ways of helping people in perception of the real world is becoming higher and higher every year. This thesis provides information about design and implementation of machine vision for mobile assembly robot. The work has been done as a part of LUT project in Laboratory of Intelligent Machines. The aim of this work is to create a working vision system. The qualitative and quantitative research were done to complete this task. In the first part, the author presents the theoretical background of such things as digital camera work principles, wireless transmission basics, creation of live stream, methods used for pattern recognition. Formulas, dependencies and previous research related to the topic are shown. In the second part, the equipment used for the project is described. There is information about the brands, models, capabilities and also requirements needed for implementation. Although, the author gives a description of LabVIEW software, its add-ons and OpenCV which are used in the project. Furthermore, one can find results in further section of considered thesis. They mainly represented by screenshots from cameras, working station and photos of the system. The key result of this thesis is vision system created for the needs of mobile assembly robot. Therefore, it is possible to see graphically what was done on examples. Future research in this field includes optimization of the pattern recognition algorithm. This will give less response time for recognizing objects. Presented by author system can be used also for further activities which include artificial intelligence usage.
Resumo:
Dans l’optique que la télésurveillance est devenue un outil indispensable en matière de sécurité, notre projet de recherche porte sur la manière dont elle est utilisée à des fins de gestion de l’ordre dans une propriété privée de masse (propriété privée que le public général est invité à visiter). Il s’agit de comprendre le rôle du centre de contrôle de télésurveillance dans la gestion d’un centre commercial. De façon plus spécifique, nous voulons décrire le fonctionnement et les objectifs des technologies de télésurveillance et les méthodes de contrôle utilisées dans un espace privé de masse. Nous voulons décrire les pratiques des agents affectés au centre de contrôle de télésurveillance ainsi que leur perception des notions de sécurité et d’ordre, avec une attention particulière accordée à la surveillance des lieux. Le site que nous avons sélectionné est un édifice situé en plein cœur du centre-ville de Montréal, où nous retrouvons des galeries commerciales abritant plusieurs restaurants et boutiques. Afin d’atteindre nos objectifs de recherche, nous avons fait plus de 150 heures d’observation participante dans le centre de contrôle de télésurveillance. Nos observations étaient complétées par des entretiens spontanés, afin de bien comprendre la dynamique et les interactions entre les agents, les autres employés et les visiteurs. Ainsi, notre matériel empirique est surtout de nature qualitative, mais nous avons complété ces données avec une grille d’analyse quantitative permettant une analyse minutieuse de l’emploi du temps des agents de sécurité à l’aide d’un fichier informatisé. Nous sommes en mesure d’établir que la surveillance dans une propriété privée de masse vise, à biens des égards, la gestion de l’image. La sécurité proprement dite est reléguée au second plan, derrière tout ce qui est relatif au marketing et à l’encouragement à la consommation. De plus, nous avons constaté que les agents de sécurité dans de tels lieux servent surtout à répondre à des besoins organisationnels ponctuels, leur quotidien n’étant guidé par aucune mission globale. Quant au centre de contrôle de vidéosurveillance, nous pouvons affirmer que son rôle est de s’assurer que toutes les activités au centre se déroulent comme convenu par les gestionnaires de l’établissement.
Resumo:
Pour respecter les droits d'auteur, la version électronique de ce mémoire à été dépouillée de ses documents visuels et audio-visuels. La version intégrale du mémoire a été déposée au Service de la gestion des documents et des archives de l'Université de Montréal.
Resumo:
Dans une perspective d’analyse des risques pour la santé publique, l’estimation de l’exposition revêt une importance capitale. Parmi les approches existantes d’estimation de l’exposition, l’utilisation d’outils, tels que des questionnaires alimentaires, la modélisation toxicocinétique ou les reconstructions de doses, en complément de la surveillance biologique, permet de raffiner les estimations, et ainsi, de mieux caractériser les risques pour la santé. Ces différents outils et approches ont été développés et appliqués à deux substances d’intérêt, le méthylmercure et le sélénium en raison des effets toxiques bien connus du méthylmercure, de l’interaction entre le méthylmercure et le sélénium réduisant potentiellement ces effets toxiques, et de l’existence de sources communes via la consommation de poisson. Ainsi, l’objectif général de cette thèse consistait à produire des données cinétiques et comparatives manquantes pour la validation et l’interprétation d’approches et d’outils d’évaluation de l’exposition au méthylmercure et au sélénium. Pour ce faire, l’influence du choix de la méthode d’évaluation de l’exposition au méthylmercure a été déterminée en comparant les apports quotidiens et les risques pour la santé estimés par différentes approches (évaluation directe de l’exposition par la surveillance biologique combinée à la modélisation toxicocinétique ou évaluation indirecte par questionnaire alimentaire). D’importantes différences entre ces deux approches ont été observées : les apports quotidiens de méthylmercure estimés par questionnaires sont en moyenne six fois plus élevés que ceux estimés à l’aide de surveillance biologique et modélisation. Ces deux méthodes conduisent à une appréciation des risques pour la santé divergente puisqu’avec l’approche indirecte, les doses quotidiennes estimées de méthylmercure dépassent les normes de Santé Canada pour 21 des 23 volontaires, alors qu’avec l’approche directe, seulement 2 des 23 volontaires sont susceptibles de dépasser les normes. Ces différences pourraient être dues, entre autres, à des biais de mémoire et de désirabilité lors de la complétion des questionnaires. En outre, l’étude de la distribution du sélénium dans différentes matrices biologiques suite à une exposition non alimentaire (shampoing à forte teneur en sélénium) visait, d’une part, à étudier la cinétique du sélénium provenant de cette source d’exposition et, d’autre part, à évaluer la contribution de cette source à la charge corporelle totale. Un suivi des concentrations biologiques (sang, urine, cheveux et ongles) pendant une période de 18 mois chez des volontaires exposés à une source non alimentaire de sélénium a contribué à mieux expliciter les mécanismes de transfert du sélénium du site d’absorption vers le sang (concomitance des voies régulées et non régulées). Ceci a permis de montrer que, contrairement au méthylmercure, l’utilisation des cheveux comme biomarqueur peut mener à une surestimation importante de la charge corporelle réelle en sélénium en cas de non contrôle de facteurs confondants tels que l’utilisation de shampoing contenant du sélénium. Finalement, une analyse exhaustive des données de surveillance biologique du sélénium issues de 75 études publiées dans la littérature a permis de mieux comprendre la cinétique globale du sélénium dans l’organisme humain. En particulier, elle a permis le développement d’un outil reliant les apports quotidiens et les concentrations biologiques de sélénium dans les différentes matrices à l’aide d’algorithmes mathématiques. Conséquemment, à l’aide de ces données cinétiques exprimées par un système d’équations logarithmiques et de leur représentation graphique, il est possible d’estimer les apports quotidiens chez un individu à partir de divers prélèvements biologiques, et ainsi, de faciliter la comparaison d’études de surveillance biologique du sélénium utilisant des biomarqueurs différents. L’ensemble de ces résultats de recherche montre que la méthode choisie pour évaluer l’exposition a un impact important sur les estimations des risques associés. De plus, les recherches menées ont permis de mettre en évidence que le sélénium non alimentaire ne contribue pas de façon significative à la charge corporelle totale, mais constitue un facteur de confusion pour l’estimation de la charge corporelle réelle en sélénium. Finalement, la détermination des équations et des coefficients reliant les concentrations de sélénium entre différentes matrices biologiques, à l’aide d’une vaste base de données cinétiques, concourt à mieux interpréter les résultats de surveillance biologique.
Resumo:
À mesure que la population des personnes agées dans les pays industrialisés augmente au fil de années, les ressources nécessaires au maintien du niveau de vie de ces personnes augmentent aussi. Des statistiques montrent que les chutes sont l’une des principales causes d’hospitalisation chez les personnes agées, et, de plus, il a été démontré que le risque de chute d’une personne agée a une correlation avec sa capacité de maintien de l’équilibre en étant debout. Il est donc d’intérêt de développer un système automatisé pour analyser l’équilibre chez une personne, comme moyen d’évaluation objective. Dans cette étude, nous avons proposé l’implémentation d’un tel système. En se basant sur une installation simple contenant une seule caméra sur un trépied, on a développé un algorithme utilisant une implémentation de la méthode de détection d’objet de Viola-Jones, ainsi qu’un appariement de gabarit, pour suivre autant le mouvement latéral que celui antérieur-postérieur d’un sujet. On a obtenu des bons résultats avec les deux types de suivi, cependant l’algorithme est sensible aux conditions d’éclairage, ainsi qu’à toute source de bruit présent dans les images. Il y aurait de l’intérêt, comme développement futur, d’intégrer les deux types de suivi, pour ainsi obtenir un seul ensemble de données facile à interpréter.
Resumo:
L’analyse de la marche a émergé comme l’un des domaines médicaux le plus im- portants récemment. Les systèmes à base de marqueurs sont les méthodes les plus fa- vorisées par l’évaluation du mouvement humain et l’analyse de la marche, cependant, ces systèmes nécessitent des équipements et de l’expertise spécifiques et sont lourds, coûteux et difficiles à utiliser. De nombreuses approches récentes basées sur la vision par ordinateur ont été développées pour réduire le coût des systèmes de capture de mou- vement tout en assurant un résultat de haute précision. Dans cette thèse, nous présentons notre nouveau système d’analyse de la démarche à faible coût, qui est composé de deux caméras vidéo monoculaire placées sur le côté gauche et droit d’un tapis roulant. Chaque modèle 2D de la moitié du squelette humain est reconstruit à partir de chaque vue sur la base de la segmentation dynamique de la couleur, l’analyse de la marche est alors effectuée sur ces deux modèles. La validation avec l’état de l’art basée sur la vision du système de capture de mouvement (en utilisant le Microsoft Kinect) et la réalité du ter- rain (avec des marqueurs) a été faite pour démontrer la robustesse et l’efficacité de notre système. L’erreur moyenne de l’estimation du modèle de squelette humain par rapport à la réalité du terrain entre notre méthode vs Kinect est très prometteur: les joints des angles de cuisses (6,29◦ contre 9,68◦), jambes (7,68◦ contre 11,47◦), pieds (6,14◦ contre 13,63◦), la longueur de la foulée (6.14cm rapport de 13.63cm) sont meilleurs et plus stables que ceux de la Kinect, alors que le système peut maintenir une précision assez proche de la Kinect pour les bras (7,29◦ contre 6,12◦), les bras inférieurs (8,33◦ contre 8,04◦), et le torse (8,69◦contre 6,47◦). Basé sur le modèle de squelette obtenu par chaque méthode, nous avons réalisé une étude de symétrie sur différentes articulations (coude, genou et cheville) en utilisant chaque méthode sur trois sujets différents pour voir quelle méthode permet de distinguer plus efficacement la caractéristique symétrie / asymétrie de la marche. Dans notre test, notre système a un angle de genou au maximum de 8,97◦ et 13,86◦ pour des promenades normale et asymétrique respectivement, tandis que la Kinect a donné 10,58◦et 11,94◦. Par rapport à la réalité de terrain, 7,64◦et 14,34◦, notre système a montré une plus grande précision et pouvoir discriminant entre les deux cas.
Resumo:
« Heavy Metal Generations » is the fourth volume in the series of papers drawn from the 2012 Music, Metal and Politics international conference (http://www.inter-disciplinary.net/publishing/product/heavy-metal-generations/).